Rainer Huber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rainer Huber has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Birger Kollmeier
Cluster of Excellence “Hearing4all”, Oldenburg, Germany
4 shared publicationsThomas Bisitz
A HörTech gGmbH and Cluster of Excellence Hearing4All , Oldenburg , Germany
2 shared publications- Thomas Rohdenburg
Universität Oldenburg, Medizinische Physik, Carl-von-Ossietzky Str. 9-11, 26111 Oldenburg, Germany
2 shared publications - Andrea Hildebrandt
Department of Psychology, Carl von Ossietzky Universität Oldenburg, Oldenburg, Germany
1 shared publication - Andreas Hein
Assistance Systems and Medical Device Technology, University of Oldenburg, Oldenburg, Germany
1 shared publication Arno Kerling
1 shared publication
Latest Publications
- Open Access
- 12 September 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (8) , 1-7
Microphone calibration estimation for mobile audiological tests with resonating bottles
Audiological tests on smartphones require consistent microphone recordings across device types with a reasonable standard uncertainty (2-3 Decibel (dB)) of the sound pressure level at the microphone. However, the calibration of smartphone microphones by the non-expert user is still an unsolved issue. We show that whistling on standardized glass bottles permits a coarse sound level calibration with an uncertainty that is smaller than the standard uncertainty of clinical audiograms (4.9dB) and enough for mobile health (mHealth) products. We define and test a calibration procedure with bottle-whistles for smartphones. The empirical sound pressure levels are used to calculate the mean and standard deviation of a single measurement. Two uncalibrated studies with a total of 30 participants, one calibrated study with 11 participants. The mean maximal sound pressure level of 330 ml Vichy-shape bottle-whistles at 50 cm distance is 92.8 ± 1.6dB sound pressure level (SPL). The sound pressure level variation of a single measurement is 3.0dB SPL. In comparison to other possible ways of level calibration estimates for smartphones (e.g. level of own voice, level of common environmental sounds), the current method appears to be robust in background noise and easily reproducible with glass bottles of defined dimensions.
- 12 September 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (8) , 1-7
Open AccessMicrophone calibration estimation for mobile audiological tests with resonating bottles
Audiological tests on smartphones require consistent microphone recordings across device types with a reasonable standard uncertainty (2-3 Decibel (dB)) of the sound pressure level at the microphone. However, the calibration of smartphone microphones by the non-expert user is still an unsolved issue. We show that whistling on standardized glass bottles permits a coarse sound level calibration with an uncertainty that is smaller than the standard uncertainty of clinical audiograms (4.9dB) and enough for mobile health (mHealth) products. We define and test a calibration procedure with bottle-whistles for smartphones. The empirical sound pressure levels are used to calculate the mean and standard deviation of a single measurement. Two uncalibrated studies with a total of 30 participants, one calibrated study with 11 participants. The mean maximal sound pressure level of 330 ml Vichy-shape bottle-whistles at 50 cm distance is 92.8 ± 1.6dB sound pressure level (SPL). The sound pressure level variation of a single measurement is 3.0dB SPL. In comparison to other possible ways of level calibration estimates for smartphones (e.g. level of own voice, level of common environmental sounds), the current method appears to be robust in background noise and easily reproducible with glass bottles of defined dimensions.
- 25 January 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (2) , 159-171
Evaluation of a semi-supervised self-adjustment fine-tuning procedure for hearing aids
This study investigated the effects of different adjustment criteria and sound scenes on self-adjusted hearing-aid gain settings. Self-adjusted settings were evaluated for speech recognition in noi...
- 25 January 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (2) , 159-171
Evaluation of a semi-supervised self-adjustment fine-tuning procedure for hearing aids
This study investigated the effects of different adjustment criteria and sound scenes on self-adjusted hearing-aid gain settings. Self-adjusted settings were evaluated for speech recognition in noi...
- 1 April 2018
- Published by Elsevier in Speech Communication
- Vol. 98, 85-94
Evaluation of an automated speech-controlled listening test with spontaneous and read responses
- 1 April 2018
- Published by Elsevier in Speech Communication
- Vol. 98, 85-94
Evaluation of an automated speech-controlled listening test with spontaneous and read responses
- 1 March 2018
- Published by Elsevier in Hearing Research
- Vol. 359, 40-49
Single-ended prediction of listening effort using deep neural networks
- 1 March 2018
- Published by Elsevier in Hearing Research
- Vol. 359, 40-49
Single-ended prediction of listening effort using deep neural networks
- 23 January 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup3) , S55-S61
Comparison of single-microphone noise reduction schemes: can hearing impaired listeners tell the difference?
Objective: The perceived qualities of nine different single-microphone noise reduction (SMNR) algorithms were to be evaluated and compared in subjective listening tests with normal hearing and hearing impaired (HI) listeners. Design: Speech samples added with traffic noise or with party noise were processed by the SMNR algorithms. Subjects rated the amount of speech distortions, intrusiveness of background noise, listening effort and overall quality, using a simplified MUSHRA (ITU-R, 2003 ITU-R. 2003. Method for the subjective assessment of intermediate quality levels of coding systems. ITU-R Recommendation BS.1534, International Telecommunications Union, Geneva, Switzerland. [Google Scholar] ) assessment method. Study sample: 18 normal hearing and 18 moderately HI subjects participated in the study. Results: Significant differences between the rating behaviours of the two subject groups were observed: While normal hearing subjects clearly differentiated between different SMNR algorithms, HI subjects rated all processed signals very similarly. Moreover, HI subjects rated speech distortions of the unprocessed, noisier signals as being more severe than the distortions of the processed signals, in contrast to normal hearing subjects. Conclusions: It seems harder for HI listeners to distinguish between additive noise and speech distortions or/and they might have a different understanding of the term “speech distortion” than normal hearing listeners have. The findings confirm that the evaluation of SMNR schemes for hearing aids should always involve HI listeners.
- 23 January 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 57 (sup3) , S55-S61
Comparison of single-microphone noise reduction schemes: can hearing impaired listeners tell the difference?
Objective: The perceived qualities of nine different single-microphone noise reduction (SMNR) algorithms were to be evaluated and compared in subjective listening tests with normal hearing and hearing impaired (HI) listeners. Design: Speech samples added with traffic noise or with party noise were processed by the SMNR algorithms. Subjects rated the amount of speech distortions, intrusiveness of background noise, listening effort and overall quality, using a simplified MUSHRA (ITU-R, 2003 ITU-R. 2003. Method for the subjective assessment of intermediate quality levels of coding systems. ITU-R Recommendation BS.1534, International Telecommunications Union, Geneva, Switzerland. [Google Scholar] ) assessment method. Study sample: 18 normal hearing and 18 moderately HI subjects participated in the study. Results: Significant differences between the rating behaviours of the two subject groups were observed: While normal hearing subjects clearly differentiated between different SMNR algorithms, HI subjects rated all processed signals very similarly. Moreover, HI subjects rated speech distortions of the unprocessed, noisier signals as being more severe than the distortions of the processed signals, in contrast to normal hearing subjects. Conclusions: It seems harder for HI listeners to distinguish between additive noise and speech distortions or/and they might have a different understanding of the term “speech distortion” than normal hearing listeners have. The findings confirm that the evaluation of SMNR schemes for hearing aids should always involve HI listeners.
- 1 September 2010
- Published by Taylor & Francis in Informatics for Health and Social Care
- Vol. 35 (3-4) , 92-103
The Lower Saxony research networkdesign of environments for ageing: towards interdisciplinary research on information and communication technologies in ageing societies
Worldwide, ageing societies are bringing challenges for independent living and healthcare. Health-enabling technologies for pervasive healthcare and sensor-enhanced health information systems offer new opportunities for care. In order to identify, implement and assess such new information and communication technologies ICT the 'Lower Saxony Research Network Design of Environments for Ageing' GAL has been launched in 2008 as interdisciplinary research project. In this publication, we inform about the goals and structure of GAL, including first outcomes, as well as to discuss the potentials and possible barriers of such highly interdisciplinary research projects in the field of health-enabling technologies for pervasive healthcare. Although GAL's high interdisciplinarity at the beginning slowed down the speed of research progress, we can now work on problems, which can hardly be solved by one or few disciplines alone. Interdisciplinary research projects on ICT in ageing s ocieties are needed and recommended
- 1 September 2010
- Published by Taylor & Francis in Informatics for Health and Social Care
- Vol. 35 (3-4) , 92-103
The Lower Saxony research networkdesign of environments for ageing: towards interdisciplinary research on information and communication technologies in ageing societies
Worldwide, ageing societies are bringing challenges for independent living and healthcare. Health-enabling technologies for pervasive healthcare and sensor-enhanced health information systems offer new opportunities for care. In order to identify, implement and assess such new information and communication technologies ICT the 'Lower Saxony Research Network Design of Environments for Ageing' GAL has been launched in 2008 as interdisciplinary research project. In this publication, we inform about the goals and structure of GAL, including first outcomes, as well as to discuss the potentials and possible barriers of such highly interdisciplinary research projects in the field of health-enabling technologies for pervasive healthcare. Although GAL's high interdisciplinarity at the beginning slowed down the speed of research progress, we can now work on problems, which can hardly be solved by one or few disciplines alone. Interdisciplinary research projects on ICT in ageing s ocieties are needed and recommended
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3158
Perception-model-based sound quality prediction for hearing aids: Big effect, small effect, and the optimization of noise reduction algorithms
- 1 November 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 120 (5_Suppleme) , 3158
Perception-model-based sound quality prediction for hearing aids: Big effect, small effect, and the optimization of noise reduction algorithms