DYDeshan Yang

Deshan Yang

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Deshan Yang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Yabo Fu

    Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO 63108, United States

    9 shared publications
  • H. Harold Li

    Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri

    7 shared publications
  • Shi Liu

    Department of Radiation Oncology, Stanford University, Stanford, CA, 94305, USA

    6 shared publications
  • Sasa Mutic

    Department of Radiation Oncology, Washington University, St. Louis, MO 63110, USA

    4 shared publications
  • Xiao Chang

    Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri

    4 shared publications
  • Xue Wu

    Washington University in Saint Louis

    4 shared publications

Latest Publications

  • GroupRegNet: a groupwise one-shot deep learning-based 4D image registration method

    by Yunlu Zhang, Xue Wu, H Michael Gach, H Harold Li, Deshan Yang

    Accurate deformable four-dimensional (4D) (three-dimensional in space and time) medical images registration is essential in a variety of medical applications. Deep learning-based methods have recently gained popularity in this area for the significantly lower inference time. However, they suffer from drawbacks of non-optimal accuracy and the requirement of a large amount of training data. A new method named GroupRegNet is proposed to address both limitations. The deformation fields to warp all images in the group into a common template is obtained through one-shot learning. The use of the implicit template reduces bias and accumulated error associated with the specified reference image. The one-shot learning strategy is similar to the conventional iterative optimization method but the motion model and parameters are replaced with a convolutional neural network and the weights of the network. GroupRegNet also features a simpler network design and a more straightforward registration process, which eliminates the need to break up the input image into patches. The proposed method was quantitatively evaluated on two public respiratory-binned 4D-computed tomography datasets. The results suggest that GroupRegNet outperforms the latest published deep learning-based methods and is comparable to the top conventional method pTVreg. To facilitate future research, the source code is available at https://github.com/vincentme/GroupRegNet .


  • Open Access

    GroupRegNet: A Groupwise One-shot Deep Learning-based 4D Image Registration Method

    by Yunlu Zhang, Xue Wu, H. Michael Gach, Harold Li, Deshan Yang

    Accurate deformable 4-dimensional (4D) (3-dimensional in space and time) medical images registration is essential in a variety of medical applications. Deep learning-based methods have recently gained popularity in this area for the significant lower inference time. However, they suffer from drawbacks of non-optimal accuracy and the requirement of a large amount of training data. A new method named GroupRegNet is proposed to address both limitations. The deformation fields to warp all images in the group into a common template is obtained through one-shot learning. The use of the implicit template reduces bias and accumulated error associated with the specified reference image. The one-shot learning strategy is similar to the conventional iterative optimization method but the motion model and parameters are replaced with a convolutional neural network (CNN) and the weights of the network. GroupRegNet also features a simpler network design and a more straightforward registration process, which eliminates the need to break up the input image into patches. The proposed method was quantitatively evaluated on two public respiratory-binned 4D-CT datasets. The results suggest that GroupRegNet outperforms the latest published deep learning-based methods and is comparable to the top conventional method pTVreg. To facilitate future research, the source code is available at https://github.com/vincentme/GroupRegNet.

  • Open Access

    Using prediction models to evaluate magnetic resonance image guided radiation therapy plans

    by M. Allan Thomas, Joshua Olick-Gibson, Yabo Fu, Parag J. Parikh, Olga Green, Deshan Yang


  • Technical Note: Automatic segmentation of CT images for ventral body composition analysis

    by Yabo Fu, Joseph E. Ippolito, Daniel R. Ludwig, Rehan Nizamuddin, Harold H. Li, Deshan Yang

    Purpose: Body composition is known to be associated with many diseases including diabetes, cancers, and cardiovascular diseases. In this paper, we developed a fully automatic body tissue decomposition procedure to segment three major compartments that are related to body composition analysis — subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), and muscle. Three additional compartments — the ventral cavity, lung, and bones — were also segmented during the segmentation process to assist segmentation of the major compartments.Methods: A convolutional neural network (CNN) model with densely connected layers was developed to perform ventral cavity segmentation. An image processing workflow was developed to segment the ventral cavity in any patient’s computed tomography (CT) using the CNN model, then further segment the body tissue into multiple compartments using hysteresis thresholding followed by morphological operations. It is important to segment ventral cavity firstly to allow accurate separation of compartments with similar Hounsfield unit (HU) inside and outside the ventral cavity.Results: The ventral cavity segmentation CNN model was trained and tested with manually labeled ventral cavities in 60 CTs. Dice scores (mean ± standard deviation) for ventral cavity segmentation were 0.966 ± 0.012. Tested on CT datasets with intravenous (IV) and oral contrast, the Dice scores were 0.96 ± 0.02, 0.94 ± 0.06, 0.96 ± 0.04, 0.95 ± 0.04, and 0.99 ± 0.01 for bone, VAT, SAT, muscle, and lung, respectively. The respective Dice scores were 0.97 ± 0.02, 0.94 ± 0.07, 0.93 ± 0.06, 0.91 ± 0.04, and 0.99 ± 0.01 for non‐contrast CT datasets.Conclusion: A body tissue decomposition procedure was developed to automatically segment multiple compartments of the ventral body. The proposed method enables fully automated quantification of three‐dimensional (3D) ventral body composition metrics from CT images.


  • Open Access

    Development and evaluation of machine learning models for voxel dose predictions in online adaptive magnetic resonance guided radiation therapy

    by M. Allan Thomas, Yabo Fu, Deshan Yang

    Purpose: Daily online adaptive plan quality in magnetic resonance imaging guided radiation therapy (MRgRT) is difficult to assess in relation to the fully optimized, high quality plans traditionally established offline. Machine learning prediction models developed in this work are capable of predicting 3D dose distributions, enabling the evaluation of online adaptive plan quality to better inform adaptive decision‐making in MRgRT.Methods: Artificial neural networks predicted 3D dose distributions from input variables related to patient anatomy, geometry, and target/organ‐at‐risk relationships in over 300 treatment plans from 53 patients receiving adaptive, linac‐based MRgRT for abdominal cancers. The models do not include any beam related variables such as beam angles or fluence and were optimized to balance errors related to raw dose and specific plan quality metrics used to guide daily online adaptive decisions.Results: Averaged over all plans, the dose prediction error and the absolute error were 0.1 ± 3.4 Gy (0.1 ± 6.2%) and 3.5 ± 2.4 Gy (6.4 ± 4.3%) respectively. Plan metric prediction errors were −0.1 ± 1.5%, −0.5 ± 2.1%, −0.9 ± 2.2 Gy, and 0.1 ± 2.7 Gy for V95, V100, D95, and Dmean respectively. Plan metric prediction absolute errors were 1.1 ± 1.1%, 1.5 ± 1.5%, 1.9 ± 1.4 Gy, and 2.2 ± 1.6 Gy. Approximately 10% (25) of the plans studied were clearly identified by the prediction models as inferior quality plans needing further optimization and refinement.Conclusion: Machine learning prediction models for treatment plan 3D dose distributions in online adaptive MRgRT were developed and tested. Clinical integration of the models requires minimal effort, producing 3D dose predictions for a new patient’s plan using only target and OAR structures as inputs. These models can enable improved workflows for MRgRT through more informed plan optimization and plan quality assessment in real time.


  • Automatic large quantity landmark pairs detection in 4DCT lung images

    by Yabo Fu, Xue Wu, Allan M. Thomas, Harold H. Li, Deshan Yang

    Purpose: To automatically and precisely detect a large quantity of landmark pairs between two lung computed tomography (CT) images to support evaluation of deformable image registration (DIR). We expect that the generated landmark pairs will significantly augment the current lung CT benchmark datasets in both quantity and positional accuracy.Methods: A large number of landmark pairs were detected within the lung between the end‐exhalation (EE) and end‐inhalation (EI) phases of the lung four‐dimensional computed tomography (4DCT) datasets. Thousands of landmarks were detected by applying the Harris‐Stephens corner detection algorithm on the probability maps of the lung vasculature tree. A parametric image registration method (pTVreg) was used to establish initial landmark correspondence by registering the images at EE and EI phases. A multi‐stream pseudo‐siamese (MSPS) network was then developed to further improve the landmark pair positional accuracy by directly predicting three‐dimensional (3D) shifts to optimally align the landmarks in EE to their counterparts in EI. Positional accuracies of the detected landmark pairs were evaluated using both digital phantoms and publicly available landmark pairs.Results: Dense sets of landmark pairs were detected for 10 4DCT lung datasets, with an average of 1886 landmark pairs per case. The mean and standard deviation of target registration error (TRE) were 0.47 ± 0.45 mm with 98% of landmark pairs having a TRE smaller than 2 mm for 10 digital phantom cases. Tests using 300 manually labeled landmark pairs in 10 lung 4DCT benchmark datasets (DIRLAB) produced TRE results of 0.73 ± 0.53 mm with 97% of landmark pairs having a TRE smaller than 2 mm.Conclusion: A new method was developed to automatically and precisely detect a large quantity of landmark pairs between lung CT image pairs. The detected landmark pairs could be used as benchmark datasets for more accurate and informative quantitative evaluation of DIR algorithms.


  • A novel MRI segmentation method using CNN‐based correction network for MRI‐guided adaptive radiotherapy

    by Yabo Fu, Thomas R. Mazur, Xue Wu, Shi Liu, Xiao Chang, Yonggang Lu, H. Harold Li, Hyun Kim, Michael C. Roach, Lauren Henke, et al.

    Purpose: The purpose of this study was to expedite the contouring process for MRI‐guided adaptive radiotherapy (MR‐IGART), a convolutional neural network (CNN) deep‐learning (DL) model is proposed to accurately segment the liver, kidneys, stomach, bowel and duodenum in 3D MR images.Methods: Images and structure contours for 120 patients were collected retrospectively. Treatment sites included pancreas, liver, stomach, adrenal gland, and prostate. The proposed DL model contains a voxel‐wise label prediction CNN and a correction network which consists of two sub‐networks. The prediction CNN and sub‐networks in the correction network each includes a dense block which consists of twelve densely connected convolutional layers. The correction network was designed to improve the voxel‐wise labeling accuracy of a CNN by learning and enforcing implicit anatomical constraints in the segmentation process. Its sub‐networks learn to fix the erroneous classification of its previous network by taking as input both the original images and the softmax probability maps generated from its previous sub‐network. The parameters of each sub‐network were trained independently using piecewise training. The model was trained on 100 datasets, validated on 10 datasets and tested on the remaining 10 datasets. Dice coefficient, Hausdorff distance (HD) were calculated to evaluate the segmentation accuracy.Results: The proposed DL model was able to segment the organs with good accuracy. The correction network outperformed the conditional random field (CRF), a most comparable method that is usually applied as a post‐processing step. For the 10 testing patients, the average Dice coefficients were 95.3 ± 0.73, 93.1 ± 2.22, 85.0 ± 3.75, 86.6 ± 2.69, and 65.5 ± 8.90 for liver, kidneys, stomach, bowel, and duodenum, respectively. The mean Hausdorff Distance (HD) were 5.41 ± 2.34, 6.23 ± 4.59, 6.88 ± 4.89, 5.90 ± 4.05, and 7.99 ± 6.84 mm, respectively. Manual contouring, as to correct the automatic segmentation results, was four times as fast as manual contouring from scratch.Conclusion: The proposed method can automatically segment the liver, kidneys, stomach, bowel, and duodenum in 3D MR images with good accuracy. It is useful to expedite the manual contouring for MR‐IGART.


  • A practical implementation of physics quality assurance for photon adaptive radiotherapy

    by Bin Cai, Olga L. Green, Rojano Kashani, Vivian L. Rodriguez, Sasa Mutic, Deshan Yang


  • An adaptive motion regularization technique to support sliding motion in deformable image registration

    by Yabo Fu, Shi Liu, H. Harold Li, Hua Li, Deshan Yang

    Purpose: Isotropic smoothing has been conventionally used to regularize deformation vector fields (DVFs) in deformable image registration (DIR). However, the isotropic smoothing method enforces global smoothness and therefore cannot accurately model the complex tissue deformation, such as sliding motion at organ boundaries. To accurately model and estimate sliding tissue motion, an adaptive direction‐dependent DVF regularization technique was developed in this study.Methods: A DVF is computed and updated iteratively by minimizing the intensity differences between the images. In each iteration, the DVF was smoothed using an adaptive direction‐dependent filter which enforces different motion propagation mechanisms along the primary normal and tangential directions of soft tissue local structures. A Gaussian isotropic filter was used along the normal direction while a bilateral filter was used along the tangential direction. To support large sliding motion, an automatic method was developed to delineate sliding surfaces, such as the chest wall and abdominal wall, where large organ sliding motion occurs. Parameters of the DVF regularization were adjusted adaptively based on a distance map to the sliding surfaces. The proposed method was tested on 14 4D‐CT datasets at End‐Inhalation (EI) and End‐Exhalation (EE) phases of a respiratory cycle (10 public lung datasets, 3 upper abdomen datasets and 1 digital phantom dataset). TRE results of the 10 lung datasets were compared to results from six other existing DIR methods. For the three upper abdomen patient datasets, DIR accuracy was evaluated using manually defined landmarks across the lung and the abdomen. For the digital phantom dataset, DIR accuracy was evaluated using the ground truth displacement of a total 40,000 points that were evenly distributed across the phantom.Results: The results showed that the sliding motion was preserved near the surface of chest wall and abdominal wall. The average target registration error (TRE) was reduced by 35.1% using the proposed method in comparison with five other methods on the 10 lung datasets. The sum of squared difference (SSD) after registration using the proposed method was 4.4% and 11.4% smaller than the SSDs obtained using isotropic smoothing and bilateral smoothing respectively. On the digital phantom, the average TRE was reduced by 59.6% near the surface of liver and by 53.7% near the surface of spleen using the proposed method. Contour propagation and Jacobian determinant analysis of DVF suggested an overall improved accuracy using the proposed method.Conclusion: An adaptive direction‐dependent DVF regularization method has been developed to model the sliding tissue motion of the thoracic and abdominal organs. The overall motion estimation accuracy has been improved especially near the chest wall and abdominal wall where large organ sliding motion occurs.