Moina Ajmeri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Moina Ajmeri has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Ahmad Ali
Electrical Engineering Dept., Indian Institute of Technology Patna, Patna, India
6 shared publications- Priyanshu Kumar
Department of Electrical and Electronics Engineering, Dayananda Sagar College of Engineering, Bengaluru 560111, Karnataka, India
3 shared publications - Satyendra Kumar
National Institute of Technology Patna, Patna, India
3 shared publications - Ashutosh Kumar Singh
Department of Electrical Engineering, National Institute of Technology Patna, Patna, Bihar, India
2 shared publications - Maneesh Kumar Gupta
Electrical Engineering Department, National Institute of Technology, Patna, India
2 shared publications - Rajib Kumar Mandal
Department of Electrical Engineering, National Institute of Technology, Patna, India
2 shared publications
Latest Publications
- 3 November 2026
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
A feed-forward and fractional-order feedback control strategy for integrating and unstable systems
A feed-forward fractional-order control strategy employing a feedback loop is developed for unstable and integrating types of processes. The suggested method combines the proactive disturbance rejection capability of the feed-forward concept with fractional-order control, which uses fractional calculus to provide greater flexibility and improved controller tuning. The primary goal is to reduce the disturbances’ effect before they influence the actual process variable, resulting in better control performance, improved stability and more effective operation than conventional control schemes. The forward path control is analytically designed in such a way that it is completely decoupled from the design of feedback control (proportional-integral or proportional-integral-derivative). The proposed methodology provides a sufficiently fast and smooth set-point tracking response even in the presence of noise, disturbance and process parameter perturbations. The results presented in this study further demonstrate the effectiveness of the proposed scheme in achieving significantly improved closed-loop performance (smaller integral square error and integral absolute error) compared to the previous arts under both the nominal and perturbed conditions.
- 3 November 2026
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
A feed-forward and fractional-order feedback control strategy for integrating and unstable systems
A feed-forward fractional-order control strategy employing a feedback loop is developed for unstable and integrating types of processes. The suggested method combines the proactive disturbance rejection capability of the feed-forward concept with fractional-order control, which uses fractional calculus to provide greater flexibility and improved controller tuning. The primary goal is to reduce the disturbances’ effect before they influence the actual process variable, resulting in better control performance, improved stability and more effective operation than conventional control schemes. The forward path control is analytically designed in such a way that it is completely decoupled from the design of feedback control (proportional-integral or proportional-integral-derivative). The proposed methodology provides a sufficiently fast and smooth set-point tracking response even in the presence of noise, disturbance and process parameter perturbations. The results presented in this study further demonstrate the effectiveness of the proposed scheme in achieving significantly improved closed-loop performance (smaller integral square error and integral absolute error) compared to the previous arts under both the nominal and perturbed conditions.
- 1 May 2026
- Published by Springer Nature
- p. 217-226
Optimal Fractional-Order Model and Smith Predictor Control for Higher Order System
- 1 May 2026
- Published by Springer Nature
- p. 217-226
Optimal Fractional-Order Model and Smith Predictor Control for Higher Order System
- 11 December 2025
- Published by Elsevier in ISA Transactions
- Vol. 169, 342-356
Handling ramp inputs and nonlinearity in unstable systems with fractional order modified Smith predictor control
- 11 December 2025
- Published by Elsevier in ISA Transactions
- Vol. 169, 342-356
Handling ramp inputs and nonlinearity in unstable systems with fractional order modified Smith predictor control
- 18 August 2025
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 20 (6)
Novel Analytical Dead Time Compensator Design for Challenging Non–Self‐Regulating Chemical Processes
The control challenges upturn if the non–self‐regulating (integrating) processes include process time delay, double poles at the origin, and inverse behavior. None of the existing literature has considered all the above‐mentioned types of processes in the frame of a unified control method. In this manuscript, a novel PD‐PID–based dead time compensator is developed for a wide range of difficult integrating systems to achieve satisfactory performance and enhanced robustness against unwanted disturbance variables and process uncertainties. Analytical relations are derived for the inner and outer loop controllers using the direct synthesis approach. Further, suitable recommendations are made to choose the appropriate value of the tunable constants so that the robustness constraints are satisfied. The efficacy of the developed control laws is justified by implementing them on various case studies through numerical simulations and theoretical analysis. The suggested method is found capable of mitigating the effect of ramp‐type disturbances also in addition to the step disturbance.
- 18 August 2025
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 20 (6)
Novel Analytical Dead Time Compensator Design for Challenging Non–Self‐Regulating Chemical Processes
The control challenges upturn if the non–self‐regulating (integrating) processes include process time delay, double poles at the origin, and inverse behavior. None of the existing literature has considered all the above‐mentioned types of processes in the frame of a unified control method. In this manuscript, a novel PD‐PID–based dead time compensator is developed for a wide range of difficult integrating systems to achieve satisfactory performance and enhanced robustness against unwanted disturbance variables and process uncertainties. Analytical relations are derived for the inner and outer loop controllers using the direct synthesis approach. Further, suitable recommendations are made to choose the appropriate value of the tunable constants so that the robustness constraints are satisfied. The efficacy of the developed control laws is justified by implementing them on various case studies through numerical simulations and theoretical analysis. The suggested method is found capable of mitigating the effect of ramp‐type disturbances also in addition to the step disturbance.
- Open Access
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59704-59712
Dual-Loop Fractional-Order IMC Structure for Unstable Systems to Handle Ramp Input Signals
One major concern in control engineering is the problem of introducing an unstable system. Such systems are even more sensitive to ramp input changes, either set-point or disturbance. We have proposed an extended fractional-order IMC (FOIMC) control for an unstable system exhibiting a time delay. The complete design involves only three adjustable parameters, such as PID tuning. In the proposed structure, the inner loop control stabilises the system, whereas the fractional IMC filter improves the overall performance, together to tackle the ramp inputs. A systematic approach is developed to tune the required design parameters to obtain the desired peak of the sensitivity function and stability margins. The proposed control is simple and can easily calculate the FOIMC parameters from the explicit formulae. The method works under practical considerations, such as process parameter perturbations and load disturbances. The developed scheme is also tested on the nonlinear continuous stirred tank reactor system. The proposed control method results in a percentage enhancement of 61.9% under the perfectly ideal condition (when the process model is equal to the actual plant) whereas 81.3% enhancement is obtained when the process parameter variations are considered for the CSTR system.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 59704-59712
Open AccessDual-Loop Fractional-Order IMC Structure for Unstable Systems to Handle Ramp Input Signals
One major concern in control engineering is the problem of introducing an unstable system. Such systems are even more sensitive to ramp input changes, either set-point or disturbance. We have proposed an extended fractional-order IMC (FOIMC) control for an unstable system exhibiting a time delay. The complete design involves only three adjustable parameters, such as PID tuning. In the proposed structure, the inner loop control stabilises the system, whereas the fractional IMC filter improves the overall performance, together to tackle the ramp inputs. A systematic approach is developed to tune the required design parameters to obtain the desired peak of the sensitivity function and stability margins. The proposed control is simple and can easily calculate the FOIMC parameters from the explicit formulae. The method works under practical considerations, such as process parameter perturbations and load disturbances. The developed scheme is also tested on the nonlinear continuous stirred tank reactor system. The proposed control method results in a percentage enhancement of 61.9% under the perfectly ideal condition (when the process model is equal to the actual plant) whereas 81.3% enhancement is obtained when the process parameter variations are considered for the CSTR system.
- 23 December 2024
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 48 (4) , 744-751
Maximum sensitivity constrained active disturbance rejection control based on reduced-order observer for DC–DC boost converter
A reduced-order observer-based active disturbance rejection control (RADRC) is suggested to regulate the output of the boost converter in the presence of unwanted disturbance including input voltage fluctuations and changes in the load side. The proposed control system is protected from unnecessary amplification of high-frequency noise signals as the derivative term is eliminated from the control laws. The extra phase lag introduced by the derivative term of ADRC is avoided, which further enhances the overall system’s stability and performance. The design parameters such as observer and controller bandwidths are selected by specifying the maximum sensitivity value of the control loop such that the desired robustness level is obtained. The proposed control strategy is experimentally validated and its superiority over contemporary techniques is justified under different scenarios. The suggested control strategy has the least settling time of 0.02 seconds and a minimum integral absolute error (IAE) value of 0.025 for the servo performance. For the regulatory performances also, the RADRC technique proves to be better than the other control methods.
- 23 December 2024
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 48 (4) , 744-751
Maximum sensitivity constrained active disturbance rejection control based on reduced-order observer for DC–DC boost converter
A reduced-order observer-based active disturbance rejection control (RADRC) is suggested to regulate the output of the boost converter in the presence of unwanted disturbance including input voltage fluctuations and changes in the load side. The proposed control system is protected from unnecessary amplification of high-frequency noise signals as the derivative term is eliminated from the control laws. The extra phase lag introduced by the derivative term of ADRC is avoided, which further enhances the overall system’s stability and performance. The design parameters such as observer and controller bandwidths are selected by specifying the maximum sensitivity value of the control loop such that the desired robustness level is obtained. The proposed control strategy is experimentally validated and its superiority over contemporary techniques is justified under different scenarios. The suggested control strategy has the least settling time of 0.02 seconds and a minimum integral absolute error (IAE) value of 0.025 for the servo performance. For the regulatory performances also, the RADRC technique proves to be better than the other control methods.
- Open Access
A Novel High-Gain Multi-Stage Switched-Capacitor-Based DC-DC Boost Converter with Closed-Loop Control
In this manuscript, a direct current (DC) boost converter based on a switched-capacitor circuit with closed-loop control, tailored for applications with high-voltage gain, is introduced. The converter utilizes a network with switching capacitors to enhance voltage gain without relying on inductors, making it ideal for high-voltage scenarios. An active disturbance rejection control (ADRC)-based control scheme is used to maintain output voltage stability in the presence of disturbances. The proposed converter’s functionality and performance are assessed through simulations and experimental tests under various load conditions. A loss analysis, considering the losses from switches and diodes, is provided to determine the net efficiency. The results from both simulations and experiments show that the proposed converter achieves a high-voltage gain, excellent load regulation, and rapid transient response, highlighting its potential for applications that require a high-voltage boosting operation.
Open AccessA Novel High-Gain Multi-Stage Switched-Capacitor-Based DC-DC Boost Converter with Closed-Loop Control
In this manuscript, a direct current (DC) boost converter based on a switched-capacitor circuit with closed-loop control, tailored for applications with high-voltage gain, is introduced. The converter utilizes a network with switching capacitors to enhance voltage gain without relying on inductors, making it ideal for high-voltage scenarios. An active disturbance rejection control (ADRC)-based control scheme is used to maintain output voltage stability in the presence of disturbances. The proposed converter’s functionality and performance are assessed through simulations and experimental tests under various load conditions. A loss analysis, considering the losses from switches and diodes, is provided to determine the net efficiency. The results from both simulations and experiments show that the proposed converter achieves a high-voltage gain, excellent load regulation, and rapid transient response, highlighting its potential for applications that require a high-voltage boosting operation.
- 1 October 2024
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 22 (10) , 1223-1235
Maximum sensitivity constrained modified Smith predictor for delayed integrating type stirred tank reactors model
A maximum sensitivity constrained modified Smith predictor consisting of two PD controllers is developed for integrating type continuously stirred tank reactors (CSTRs) model. This CSTR type model approximated as integrating first order plus time delay with and without inverse response processes is challenging to control as it contains integrating term, process time delay and a zero lying in the right half of s-plane. The inner and outer loop PD blocks are tuned to achieve the desired set-point tracking and load disturbance rejection responses using direct synthesis approach. The proposed control is free from integrating action and therefore, smooth setpoint tracking response with no overshoot is obtained which is highly desirable in the process industries. Two design parameters λ and τ are involved in the suggested control whose suitable values are recommended to achieve the desired robustness level by specifying the maximum sensitivities of the inner and outer loop transfer functions. Various illustrative models are considered to show the effectiveness and superiority of the proposed control structure. The system robustness towards process parameter perturbations and load disturbances are investigated in all the examples. Performance of the suggested modified Smith predictor is found superior as compared to the other recently published works.
- 1 October 2024
- Published by Walter de Gruyter GmbH in International Journal of Chemical Reactor Engineering
- Vol. 22 (10) , 1223-1235
Maximum sensitivity constrained modified Smith predictor for delayed integrating type stirred tank reactors model
A maximum sensitivity constrained modified Smith predictor consisting of two PD controllers is developed for integrating type continuously stirred tank reactors (CSTRs) model. This CSTR type model approximated as integrating first order plus time delay with and without inverse response processes is challenging to control as it contains integrating term, process time delay and a zero lying in the right half of s-plane. The inner and outer loop PD blocks are tuned to achieve the desired set-point tracking and load disturbance rejection responses using direct synthesis approach. The proposed control is free from integrating action and therefore, smooth setpoint tracking response with no overshoot is obtained which is highly desirable in the process industries. Two design parameters λ and τ are involved in the suggested control whose suitable values are recommended to achieve the desired robustness level by specifying the maximum sensitivities of the inner and outer loop transfer functions. Various illustrative models are considered to show the effectiveness and superiority of the proposed control structure. The system robustness towards process parameter perturbations and load disturbances are investigated in all the examples. Performance of the suggested modified Smith predictor is found superior as compared to the other recently published works.
- 1 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (1) , 899-908
Novel high-gain boost converter with experimentally validated ADRC control technique for renewable energy applications
- 1 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (1) , 899-908
Novel high-gain boost converter with experimentally validated ADRC control technique for renewable energy applications
- 28 January 2024
- Published by Springer Nature
- p. 367-380
Active Disturbance Rejection Control of a SEPIC Converter
- 28 January 2024
- Published by Springer Nature
- p. 367-380
Active Disturbance Rejection Control of a SEPIC Converter