Thomas Hocke
Research Subjects
Thomas Hocke has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Hey
Audiology, ENT Clinic, UKSH, 24105 Kiel, Germany
3 shared publications - Oliver Christian Dziemba
Klinik und Poliklinik für Hals‑, Nasen‑, Ohrenkrankheiten, Kopf- und Halschirurgie, Universitätsmedizin Greifswald, Greifswald, Deutschland
3 shared publications - Anne Hast
Cochlear Implant Center CICERO, Department of Otorhinolaryngology-Head and Neck Surgery, Uniklinikum Erlangen, Waldstr. 1, D-91054 Erlangen, Germany
2 shared publications - Florian Herrmann Schmidt
Department of Otorhinolaryngology, Head and Neck surgery, ‘Otto Körner’, Rostock University Medical Center, Rostock, Germany
2 shared publications - Friedrich Ihler
Klinik und Poliklinik für Hals‑, Nasen‑, Ohrenkrankheiten, Kopf- und Halschirurgie, Universitätsmedizin Greifswald, Greifswald, Deutschland
2 shared publications - Joachim Hornung
Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Erlangen, Germany
2 shared publications
Latest Publications
- Open Access
- 21 October 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (5) , 142
Precision Audiometry and Ecological Validity: Exploring the Link Between Patient-Reported Outcome Measures and Speech Testing in CI Users
Background/Objectives: Audiometric methods for hearing-impaired patients are constantly evolving as new therapeutic interventions and improved clinical standards are established. This study aimed to explore the relationship between patient-reported outcome measures in cochlear implant users and scores from audiometric test procedures in quiet and noise. Methods: In a prospective study, 20 postlingually deafened CI users were included. Speech comprehension was measured in quiet (by Freiburg words) and in noise (by the Oldenburg sentence test), while stationary speech-simulating or temporally fluctuating noise was applied and the noise sources were varied. Subjective feedback from the patients was obtained using the HISQUI19 questionnaire. Results: Word scores in quiet showed a significant positive correlation with the user’s subjective assessment of hearing ability using the questionnaire (Spearman’s R = 0.57). A greater correlation of the subjective evaluation of comprehension against fluctuating background noise as compared with stationary background noise was evident. On the other hand, the test–retest accuracy was reduced by a substantial factor in the transition from stationary to fluctuating background noise. Conclusions: By introducing temporal fluctuations in the background noise, the ecological validity can be improved, but at the cost of a parallel decrease in the accuracy of the test procedure. Especially in the context of studies, this knowledge may help to improve the choice of the specific test method used in evaluating the relationship between ecological validity and precision audiometry.
- 21 October 2025
- Published by MDPI AG in Audiology Research
- Vol. 15 (5) , 142
Open AccessPrecision Audiometry and Ecological Validity: Exploring the Link Between Patient-Reported Outcome Measures and Speech Testing in CI Users
Background/Objectives: Audiometric methods for hearing-impaired patients are constantly evolving as new therapeutic interventions and improved clinical standards are established. This study aimed to explore the relationship between patient-reported outcome measures in cochlear implant users and scores from audiometric test procedures in quiet and noise. Methods: In a prospective study, 20 postlingually deafened CI users were included. Speech comprehension was measured in quiet (by Freiburg words) and in noise (by the Oldenburg sentence test), while stationary speech-simulating or temporally fluctuating noise was applied and the noise sources were varied. Subjective feedback from the patients was obtained using the HISQUI19 questionnaire. Results: Word scores in quiet showed a significant positive correlation with the user’s subjective assessment of hearing ability using the questionnaire (Spearman’s R = 0.57). A greater correlation of the subjective evaluation of comprehension against fluctuating background noise as compared with stationary background noise was evident. On the other hand, the test–retest accuracy was reduced by a substantial factor in the transition from stationary to fluctuating background noise. Conclusions: By introducing temporal fluctuations in the background noise, the ecological validity can be improved, but at the cost of a parallel decrease in the accuracy of the test procedure. Especially in the context of studies, this knowledge may help to improve the choice of the specific test method used in evaluating the relationship between ecological validity and precision audiometry.
- Open Access
- 29 July 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (15) , 4436
Factors to Describe the Outcome Characteristics of a CI Recipient
Background: In cochlear implant (CI) treatment, there is a large variability in outcome. The aim of our study was to identify the independent audiometric measures that are most directly relevant for describing this variability in outcome characteristics of CI recipients. An extended audiometric test battery was used with selected adult patients in order to characterize the full range of CI outcomes. Methods: CI users were recruited for this study on the basis of their postoperative results and divided into three groups: low (1st quartile), moderate (medium decentile), and high hearing performance (4th quartile). Speech recognition was measured in quiet by using (i) monosyllabic words (40–80 dB SPL), (ii) speech reception threshold (SRT) for numbers, and (iii) the German matrix test in noise. In order to reconstruct demanding everyday listening situations in the clinic, the temporal characteristics of the background noise and the spatial arrangements of the signal sources were varied for tests in noise. In addition, a survey was conducted using the Speech, Spatial, and Qualities (SSQ) questionnaire and the Listening Effort (LE) questionnaire. Results: Fifteen subjects per group were examined (total N = 45), who did not differ significantly in terms of age, time after CI surgery, or CI use behavior. The groups differed mainly in the results of speech audiometry. For speech recognition, significant differences were found between the three groups for the monosyllabic tests in quiet and for the sentences in stationary (S0°N0°) and fluctuating (S0°NCI) noise. Word comprehension and sentence comprehension in quiet were both strongly correlated with the SRT in noise. This observation was also confirmed by a factor analysis. No significant differences were found between the three groups for the SSQ questionnaire and the LE questionnaire results. The results of the factor analysis indicate that speech recognition in noise provides information highly comparable to information from speech intelligibility in quiet. Conclusions: The factor analysis highlighted three components describing the postoperative outcome of CI patients. These were (i) the audiometrically measured supra-threshold speech recognition and (ii) near-threshold audibility, as well as (iii) the subjective assessment of the relationship to real life as determined by the questionnaires. These parameters appear well suited to setting up a framework for a test battery to assess CI outcomes.
- 29 July 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (15) , 4436
Open AccessFactors to Describe the Outcome Characteristics of a CI Recipient
Background: In cochlear implant (CI) treatment, there is a large variability in outcome. The aim of our study was to identify the independent audiometric measures that are most directly relevant for describing this variability in outcome characteristics of CI recipients. An extended audiometric test battery was used with selected adult patients in order to characterize the full range of CI outcomes. Methods: CI users were recruited for this study on the basis of their postoperative results and divided into three groups: low (1st quartile), moderate (medium decentile), and high hearing performance (4th quartile). Speech recognition was measured in quiet by using (i) monosyllabic words (40–80 dB SPL), (ii) speech reception threshold (SRT) for numbers, and (iii) the German matrix test in noise. In order to reconstruct demanding everyday listening situations in the clinic, the temporal characteristics of the background noise and the spatial arrangements of the signal sources were varied for tests in noise. In addition, a survey was conducted using the Speech, Spatial, and Qualities (SSQ) questionnaire and the Listening Effort (LE) questionnaire. Results: Fifteen subjects per group were examined (total N = 45), who did not differ significantly in terms of age, time after CI surgery, or CI use behavior. The groups differed mainly in the results of speech audiometry. For speech recognition, significant differences were found between the three groups for the monosyllabic tests in quiet and for the sentences in stationary (S0°N0°) and fluctuating (S0°NCI) noise. Word comprehension and sentence comprehension in quiet were both strongly correlated with the SRT in noise. This observation was also confirmed by a factor analysis. No significant differences were found between the three groups for the SSQ questionnaire and the LE questionnaire results. The results of the factor analysis indicate that speech recognition in noise provides information highly comparable to information from speech intelligibility in quiet. Conclusions: The factor analysis highlighted three components describing the postoperative outcome of CI patients. These were (i) the audiometrically measured supra-threshold speech recognition and (ii) near-threshold audibility, as well as (iii) the subjective assessment of the relationship to real life as determined by the questionnaires. These parameters appear well suited to setting up a framework for a test battery to assess CI outcomes.
- Open Access
- 23 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 646
Investigation of Maximum Monosyllabic Word Recognition as a Predictor of Speech Understanding with Cochlear Implant
Background: The cochlear implant (CI) is an established treatment option for patients with inadequate speech understanding and insufficient aided scores. Nevertheless, reliable predictive models and specific therapy goals regarding achievable speech understanding are still lacking. Method: In this retrospective study, 601 cases of CI fittings between 2005 and 2021 at the University Medical Center Freiburg were analyzed. We investigated the preoperative unaided maximum word recognition score (mWRS) as a minimum predictor for post-interventional scores at 65 dB SPL, WRS65(CI). The WRS65(CI) was compared with the preoperative-aided WRS, and a previously published prediction model for the WRS65(CI) was reviewed. Furthermore, the effect of duration of hearing loss, duration of HA fitting, and etiology on WRS65(CI) were investigated. Results: In 95.5% of the cases, a significant improvement in word recognition was observed after CI. WRS65(CI) achieved or exceeded mWRS in 97% of cases. Etiology had a significant impact on WRS65(CI). The predicted score was missed by more than 20 percentage points in 12.8% of cases. Discussion: Our results confirmed the minimum prediction via mWRS. A more precise prediction of the expected WRS65(CI) is possible. The etiology of hearing loss should be considered in the indication and postoperative care to achieve optimal results.
- 23 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 646
Open AccessInvestigation of Maximum Monosyllabic Word Recognition as a Predictor of Speech Understanding with Cochlear Implant
Background: The cochlear implant (CI) is an established treatment option for patients with inadequate speech understanding and insufficient aided scores. Nevertheless, reliable predictive models and specific therapy goals regarding achievable speech understanding are still lacking. Method: In this retrospective study, 601 cases of CI fittings between 2005 and 2021 at the University Medical Center Freiburg were analyzed. We investigated the preoperative unaided maximum word recognition score (mWRS) as a minimum predictor for post-interventional scores at 65 dB SPL, WRS65(CI). The WRS65(CI) was compared with the preoperative-aided WRS, and a previously published prediction model for the WRS65(CI) was reviewed. Furthermore, the effect of duration of hearing loss, duration of HA fitting, and etiology on WRS65(CI) were investigated. Results: In 95.5% of the cases, a significant improvement in word recognition was observed after CI. WRS65(CI) achieved or exceeded mWRS in 97% of cases. Etiology had a significant impact on WRS65(CI). The predicted score was missed by more than 20 percentage points in 12.8% of cases. Discussion: Our results confirmed the minimum prediction via mWRS. A more precise prediction of the expected WRS65(CI) is possible. The etiology of hearing loss should be considered in the indication and postoperative care to achieve optimal results.
- Open Access
- 16 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 500
Tone Decay Reconsidered: Preliminary Results of a Prospective Study in Hearing-Aid Users with Moderate to Severe Hearing Loss
Among hearing aid (HA) users, there is a considerable variability in word recognition scores (WRSs). This variability is most pronounced among individuals with moderately severe to severe hearing loss. The variability cannot be adequately explained by factors such as pure-tone audiogram, audiogram type or age. This prospective study was designed to investigate the relationship between tone decay (TD) and WRS in a group of HA users with corresponding pure-tone hearing loss. The study population included 22 patients with hearing loss between 50 and 80 dB HL. Aided WRS, unaided WRS and TD were assessed for both ears. TD was found to be frequency-dependent. TD and WRS were correlated, with up to R = −0.66. The TD test was revealed to be a feasible method for explaining variability in WRS among HA users with hearing loss below 80 dB. This may contribute to improved differential diagnostics. The TD test may thus offer a better understanding of the limitations of HA use in the context of cochlear implant candidacy assessment for HA users.
- 16 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 500
Open AccessTone Decay Reconsidered: Preliminary Results of a Prospective Study in Hearing-Aid Users with Moderate to Severe Hearing Loss
Among hearing aid (HA) users, there is a considerable variability in word recognition scores (WRSs). This variability is most pronounced among individuals with moderately severe to severe hearing loss. The variability cannot be adequately explained by factors such as pure-tone audiogram, audiogram type or age. This prospective study was designed to investigate the relationship between tone decay (TD) and WRS in a group of HA users with corresponding pure-tone hearing loss. The study population included 22 patients with hearing loss between 50 and 80 dB HL. Aided WRS, unaided WRS and TD were assessed for both ears. TD was found to be frequency-dependent. TD and WRS were correlated, with up to R = −0.66. The TD test was revealed to be a feasible method for explaining variability in WRS among HA users with hearing loss below 80 dB. This may contribute to improved differential diagnostics. The TD test may thus offer a better understanding of the limitations of HA use in the context of cochlear implant candidacy assessment for HA users.
- Open Access
- 13 December 2023
- Published by MDPI AG in Preprints.org
Tone Decay Reconsidered: Preliminary Results of a Prospective Study in Hearing-Aid Users With Moderate to Severe Hearing Loss
Among hearing aid (HA) users, there is a considerable variability in word-recognition scores (WRS). This variability is most pronounced among individuals with moderately severe to severe hearing loss. The variability cannot be adequately explained by factors such as the pure-tone audiogram, audiogram type, or age. This prospective study was designed to investigate the relationship between tone decay (TD) and WRS in a group of HA users with corresponding pure-tone hearing loss. The study population included 22 patients with hearing loss between 50 and 80 dB HL. Aided WRS, unaided WRS and TD were assessed for both ears. TD was found to be frequency-dependent. TD and WRS were correlated, with up to R=–0.66. The TD test was revealed as a feasible method for explaining the variability in WRS among HA users with hearing loss below 80 dB. This may contribute to improved differential diagnostics. The TD test may thus offer a better understanding of the limitations of HA use in the context of cochlear implant candidacy assessment for HA users.
- 13 December 2023
- Published by MDPI AG in Preprints.org
Open AccessTone Decay Reconsidered: Preliminary Results of a Prospective Study in Hearing-Aid Users With Moderate to Severe Hearing Loss
Among hearing aid (HA) users, there is a considerable variability in word-recognition scores (WRS). This variability is most pronounced among individuals with moderately severe to severe hearing loss. The variability cannot be adequately explained by factors such as the pure-tone audiogram, audiogram type, or age. This prospective study was designed to investigate the relationship between tone decay (TD) and WRS in a group of HA users with corresponding pure-tone hearing loss. The study population included 22 patients with hearing loss between 50 and 80 dB HL. Aided WRS, unaided WRS and TD were assessed for both ears. TD was found to be frequency-dependent. TD and WRS were correlated, with up to R=–0.66. The TD test was revealed as a feasible method for explaining the variability in WRS among HA users with hearing loss below 80 dB. This may contribute to improved differential diagnostics. The TD test may thus offer a better understanding of the limitations of HA use in the context of cochlear implant candidacy assessment for HA users.
- Open Access
- 20 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7188
The Effects of Stimulus Repetition Rate on Electrically Evoked Auditory Brainstem Potentials in Postlingually Deafened Adult Cochlear Implant Recipients
Background: By using outcome prediction scores, it is possible to distinguish between good and poor performers with cochlear implants (CI) after CI implantation. The reasons for poor performance, despite good basic conditions, can be manifold. On the one hand, the postoperative fitting may be inadequate; on the other, neurophysiological disease processes may impair speech understanding with a CI. These disease processes are not yet fully understood. In acoustics, it is known that the auditory brainstem responses (ABR) and their latencies and amplitudes allow differential diagnosis based on reference values for normal-hearing individuals. The aim of this study was to provide reference values for electrically evoked brainstem responses (EABRs) in terms of rate-dependent latencies and amplitudes. Methods: 20 ears of 18 experienced adult CI recipients with a predicted and measured good postoperative word recognition score were recruited from the clinic’s patient pool. In the same stimulation mode and intensity we measured latencies and interpeak-latencies of EABRs and electrically evoked compound action potentials (ECAPs). With a defined supra-threshold stimulation intensity above the individual ECAP threshold, we applied stimulation at several rates between 11 and 91 stimuli per second. Results: We found rate dependences for EABR latency t3 and t5 in the order of 0.19 ms and 0.37 ms, respectively, while ECAP was not affected by rate. Correspondingly, the interpeak intervals’ rate dependences for , and were of the order of 0.37 ms, 0.18 ms and 0.19 ms. Comparing the EABR amplitudes between the stimulation rates 11/s and 81/s, we found that at 81/s the amplitudes were significantly reduced down: to 73% for A3 and 81% for A5. These rate dependences of latency and amplitude in EABR have characteristics comparable to those of acoustic ABR. Conclusions: These data may serve to provide reference values for EABR and ECAP latencies, interpeak intervals and amplitudes with respect to stimulation rate. Altered response patterns of ECAPs and EABRs to normalised stimulation modes could be used in the future to describe and classify neuropathological processes in a better-differentiated way.- 20 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7188
Open AccessThe Effects of Stimulus Repetition Rate on Electrically Evoked Auditory Brainstem Potentials in Postlingually Deafened Adult Cochlear Implant Recipients
Background: By using outcome prediction scores, it is possible to distinguish between good and poor performers with cochlear implants (CI) after CI implantation. The reasons for poor performance, despite good basic conditions, can be manifold. On the one hand, the postoperative fitting may be inadequate; on the other, neurophysiological disease processes may impair speech understanding with a CI. These disease processes are not yet fully understood. In acoustics, it is known that the auditory brainstem responses (ABR) and their latencies and amplitudes allow differential diagnosis based on reference values for normal-hearing individuals. The aim of this study was to provide reference values for electrically evoked brainstem responses (EABRs) in terms of rate-dependent latencies and amplitudes. Methods: 20 ears of 18 experienced adult CI recipients with a predicted and measured good postoperative word recognition score were recruited from the clinic’s patient pool. In the same stimulation mode and intensity we measured latencies and interpeak-latencies of EABRs and electrically evoked compound action potentials (ECAPs). With a defined supra-threshold stimulation intensity above the individual ECAP threshold, we applied stimulation at several rates between 11 and 91 stimuli per second. Results: We found rate dependences for EABR latency t3 and t5 in the order of 0.19 ms and 0.37 ms, respectively, while ECAP was not affected by rate. Correspondingly, the interpeak intervals’ rate dependences for , and were of the order of 0.37 ms, 0.18 ms and 0.19 ms. Comparing the EABR amplitudes between the stimulation rates 11/s and 81/s, we found that at 81/s the amplitudes were significantly reduced down: to 73% for A3 and 81% for A5. These rate dependences of latency and amplitude in EABR have characteristics comparable to those of acoustic ABR. Conclusions: These data may serve to provide reference values for EABR and ECAP latencies, interpeak intervals and amplitudes with respect to stimulation rate. Altered response patterns of ECAPs and EABRs to normalised stimulation modes could be used in the future to describe and classify neuropathological processes in a better-differentiated way. - Open Access
- 19 October 2023
- Published by MDPI AG in Preprints.org
Effects of Stimulus Repetition Rate on Electrically Evoked Auditory Brainstem Potentials in Postlingually Deafened Adult Cochlear Implant Recipients
Background: By using outcome prediction scores, it is possible to distinguish between good and poor performers with cochlear implants (CI) after CI implantation. The reasons for poor performance, despite good basic conditions, can be manifold. On the one hand, the postoperative fitting may be inadequate; on the other, neurophysiological disease processes may impair speech understanding with a CI. These disease processes are not yet fully understood. In acoustics, it is known that the auditory brainstem responses (ABR) and their latencies and amplitudes allow differential diagnosis based on reference values for normal-hearing individuals. The aim of this study was to provide reference values for electrically evoked brainstem responses (EABRs) in terms of rate-dependent latencies and amplitudes. Methods: 20 experienced adult CI recipients with a predicted and measured good postoperative word recognition score were recruited from the clinic’s patient pool. In the same stimulation mode and intensity we measured latencies and interpeak-latencies of EABRs and electrically evoked compound action potentials (ECAPs). With a defined supra-threshold stimulation intensity above the individual ECAP threshold, we applied stimulation at several rates between 11 and 91 stimuli per second. Results: We found rate dependences for EABR latency t3 and t5 in the order of 0.19 ms and 0.37 ms respectively, while ECAP was not affected by rate. Correspondingly, the interpeak intervalls’ rate dependences for t5-t1, t5-t3 and t3-t1 were of the order of 0.37 ms, 0.18 ms and 0.19 ms. Comparing the EABR amplitudes between the stimulation rates 11/s and 81/s, we found that at 81/s the amplitudes were significantly reduced down: to 73% for A3 and 81% for A5. These rate dependences of latency and amplitude in EABR have characteristics comparable to those of acoustic ABR. Conclusions: These data may serve to provide reference values for EABR and ECAP latencies, interpeak intervals and amplitudes with respect to stimulation rate. Altered response patterns of ECAPs and EABRs to normalised stimulation modes could be used in the future to describe and classify neuropathological processes in a better-differentiated way.
- 19 October 2023
- Published by MDPI AG in Preprints.org
Open AccessEffects of Stimulus Repetition Rate on Electrically Evoked Auditory Brainstem Potentials in Postlingually Deafened Adult Cochlear Implant Recipients
Background: By using outcome prediction scores, it is possible to distinguish between good and poor performers with cochlear implants (CI) after CI implantation. The reasons for poor performance, despite good basic conditions, can be manifold. On the one hand, the postoperative fitting may be inadequate; on the other, neurophysiological disease processes may impair speech understanding with a CI. These disease processes are not yet fully understood. In acoustics, it is known that the auditory brainstem responses (ABR) and their latencies and amplitudes allow differential diagnosis based on reference values for normal-hearing individuals. The aim of this study was to provide reference values for electrically evoked brainstem responses (EABRs) in terms of rate-dependent latencies and amplitudes. Methods: 20 experienced adult CI recipients with a predicted and measured good postoperative word recognition score were recruited from the clinic’s patient pool. In the same stimulation mode and intensity we measured latencies and interpeak-latencies of EABRs and electrically evoked compound action potentials (ECAPs). With a defined supra-threshold stimulation intensity above the individual ECAP threshold, we applied stimulation at several rates between 11 and 91 stimuli per second. Results: We found rate dependences for EABR latency t3 and t5 in the order of 0.19 ms and 0.37 ms respectively, while ECAP was not affected by rate. Correspondingly, the interpeak intervalls’ rate dependences for t5-t1, t5-t3 and t3-t1 were of the order of 0.37 ms, 0.18 ms and 0.19 ms. Comparing the EABR amplitudes between the stimulation rates 11/s and 81/s, we found that at 81/s the amplitudes were significantly reduced down: to 73% for A3 and 81% for A5. These rate dependences of latency and amplitude in EABR have characteristics comparable to those of acoustic ABR. Conclusions: These data may serve to provide reference values for EABR and ECAP latencies, interpeak intervals and amplitudes with respect to stimulation rate. Altered response patterns of ECAPs and EABRs to normalised stimulation modes could be used in the future to describe and classify neuropathological processes in a better-differentiated way.
- Open Access
- 26 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6215
Evolving a Model for Cochlear Implant Outcome
Background: Cochlear implantation is an efficient treatment for postlingually deafened adults who do not benefit sufficiently from acoustic amplification. Implantation is indicated when it can be foreseen that speech recognition with a cochlear implant (CI) is superior to that with a hearing aid. Especially for subjects with residual speech recognition, it is desirable to predict CI outcome on the basis of preoperative audiological tests. Purpose: The purpose of the study was to extend and refine a previously developed model for CI outcome prediction for subjects with preoperative word recognition to include subjects with no residual hearing by incorporating additional results of routine examinations. Results: By introducing the duration of unaided hearing loss (DuHL), the median absolute error (MAE) of the prediction was reduced. While for subjects with preoperative speech recognition, the model modification did not change the MAE, for subjects with no residual speech recognition before surgery, the MAE decreased from 23.7% with the previous model to 17.2% with the extended model. Conclusions: Prediction of word recognition with CI is possible within clinically relevant limits. Outcome prediction is particularly important for preoperative counseling and in CI aftercare to support systematic monitoring of CI fitting.
- 26 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6215
Open AccessEvolving a Model for Cochlear Implant Outcome
Background: Cochlear implantation is an efficient treatment for postlingually deafened adults who do not benefit sufficiently from acoustic amplification. Implantation is indicated when it can be foreseen that speech recognition with a cochlear implant (CI) is superior to that with a hearing aid. Especially for subjects with residual speech recognition, it is desirable to predict CI outcome on the basis of preoperative audiological tests. Purpose: The purpose of the study was to extend and refine a previously developed model for CI outcome prediction for subjects with preoperative word recognition to include subjects with no residual hearing by incorporating additional results of routine examinations. Results: By introducing the duration of unaided hearing loss (DuHL), the median absolute error (MAE) of the prediction was reduced. While for subjects with preoperative speech recognition, the model modification did not change the MAE, for subjects with no residual speech recognition before surgery, the MAE decreased from 23.7% with the previous model to 17.2% with the extended model. Conclusions: Prediction of word recognition with CI is possible within clinically relevant limits. Outcome prediction is particularly important for preoperative counseling and in CI aftercare to support systematic monitoring of CI fitting.
- Open Access
- 31 July 2023
- Published by MDPI AG in Preprints.org
Evolving a Model for Cochlear Implant Outcome
Background: Cochlear implantation is an efficient treatment for postlingually deafened adults who do not benefit sufficiently from acoustic amplification. Implantation is indicated when it can be foreseen that speech recognition with a cochlear implant (CI) is superior to that with a hearing aid. Especially for subjects with residual speech recognition it is desirable to predict CI outcome on the basis of preoperative audiological tests. Purpose: The purpose of the study was to extend and to refine a previously developed model for CI outcome prediction for subjects with preoperative word recognition to include subjects with no residual hearing by incorporat-ing additional results of routine examinations. Results: By introducing the duration of unaided hearing loss (DuHL) the median absolute error (MAE) of the prediction was reduced. While for subjects with preoperative speech recognition the model modification did not change the MAE, for subjects with no residual speech recognition before surgery, the MAE decreased from 23.7% with the previous model to 17.2% with the extended model. Conclusions: Prediction of word recognition with CI is possible within clinically relevant limits. Outcome prediction is particu-larly important for preoperative counselling and in CI aftercare, to support systematic monitor-ing of CI fitting.
- 31 July 2023
- Published by MDPI AG in Preprints.org
Open AccessEvolving a Model for Cochlear Implant Outcome
Background: Cochlear implantation is an efficient treatment for postlingually deafened adults who do not benefit sufficiently from acoustic amplification. Implantation is indicated when it can be foreseen that speech recognition with a cochlear implant (CI) is superior to that with a hearing aid. Especially for subjects with residual speech recognition it is desirable to predict CI outcome on the basis of preoperative audiological tests. Purpose: The purpose of the study was to extend and to refine a previously developed model for CI outcome prediction for subjects with preoperative word recognition to include subjects with no residual hearing by incorporat-ing additional results of routine examinations. Results: By introducing the duration of unaided hearing loss (DuHL) the median absolute error (MAE) of the prediction was reduced. While for subjects with preoperative speech recognition the model modification did not change the MAE, for subjects with no residual speech recognition before surgery, the MAE decreased from 23.7% with the previous model to 17.2% with the extended model. Conclusions: Prediction of word recognition with CI is possible within clinically relevant limits. Outcome prediction is particu-larly important for preoperative counselling and in CI aftercare, to support systematic monitor-ing of CI fitting.
- Open Access
- 23 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (10) , 2941
Ecological Momentary Assessment to Obtain Signal Processing Technology Preference in Cochlear Implant Users
Background: To assess the performance of cochlear implant users, speech comprehension benefits are generally measured in controlled sound room environments of the laboratory. For field-based assessment of preference, questionnaires are generally used. Since questionnaires are typically administered at the end of an experimental period, they can be inaccurate due to retrospective recall. An alternative known as ecological momentary assessment (EMA) has begun to be used for clinical research. The objective of this study was to determine the feasibility of using EMA to obtain in-the-moment responses from cochlear implant users describing their technology preference in specific acoustic listening situations. Methods: Over a two-week period, eleven adult cochlear implant users compared two listening programs containing different sound processing technologies during everyday take-home use. Their task was to compare and vote for their preferred program. Results: A total of 205 votes were collected from acoustic environments that were classified into six listening scenes. The analysis yielded different patterns of voting among the subjects. Two subjects had a consistent preference for one sound processing technology across all acoustic scenes, three subjects changed their preference based on the acoustic scene, and six subjects had no conclusive preference for either technology. Conclusion: Results show that EMA is suitable for quantifying real-world self-reported preference, showing inter-subject variability in different listening environments. However, there is uncertainty that patients will not provide sufficient spontaneous feedback. One improvement for future research is a participant forced prompt to improve response rates.
- 23 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (10) , 2941
Open AccessEcological Momentary Assessment to Obtain Signal Processing Technology Preference in Cochlear Implant Users
Background: To assess the performance of cochlear implant users, speech comprehension benefits are generally measured in controlled sound room environments of the laboratory. For field-based assessment of preference, questionnaires are generally used. Since questionnaires are typically administered at the end of an experimental period, they can be inaccurate due to retrospective recall. An alternative known as ecological momentary assessment (EMA) has begun to be used for clinical research. The objective of this study was to determine the feasibility of using EMA to obtain in-the-moment responses from cochlear implant users describing their technology preference in specific acoustic listening situations. Methods: Over a two-week period, eleven adult cochlear implant users compared two listening programs containing different sound processing technologies during everyday take-home use. Their task was to compare and vote for their preferred program. Results: A total of 205 votes were collected from acoustic environments that were classified into six listening scenes. The analysis yielded different patterns of voting among the subjects. Two subjects had a consistent preference for one sound processing technology across all acoustic scenes, three subjects changed their preference based on the acoustic scene, and six subjects had no conclusive preference for either technology. Conclusion: Results show that EMA is suitable for quantifying real-world self-reported preference, showing inter-subject variability in different listening environments. However, there is uncertainty that patients will not provide sufficient spontaneous feedback. One improvement for future research is a participant forced prompt to improve response rates.