Baoan Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Baoan Song has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
Peiqing Zhang
9 shared publicationsShixun Dai
9 shared publicationsXiang Shen
8 shared publicationsChanggui Lin
7 shared publications- Shixun Dai
Ningbo University
6 shared publications - Peiqing Zhang
Ningbo University
5 shared publications
Latest Publications
- 1 January 2026
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 19 (2) , 267-276
基于法诺共振的全介质硫系化合物超表面高性能中红外折射率传感
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。
- 1 January 2026
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 19 (2) , 267-276
基于法诺共振的全介质硫系化合物超表面高性能中红外折射率传感
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。
- Open Access
- 3 December 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 508
Endoscopic laser speckle imaging enables real-time prediction of parathyroid function in thyroidectomy
Purpose To evaluate the clinical utility of endoscopic laser speckle contrast imaging (eLSCI) for intraoperative assessment of parathyroid gland (PTG) perfusion and functional preservation. Methods Fifteen patients undergoing unilateral/bilateral thyroidectomy at The Affiliated Lihuili Hospital of Ningbo University (November 2024 to April 2025) were prospectively enrolled. PTG perfusion was quantified using eLSCI by recording blood flow index (BFI) before and after thyroid resection. Serum parathyroid hormone (PTH) and calcium levels were measured preoperatively, at 15-min post-resection, and 24-h postoperatively. Pearson correlation analysis was used to assess the linear association between perfusion and functional parameters, while Spearman's rank correlation test was concurrently performed to verify the robustness. Results A significant correlation existed between the BFI change ratio and PTH change ratio at 15-min post-resection (r = 0.672, p = 0.006) and 24-h postoperatively (r = 0.671, p = 0.006). No significant correlation was observed between BFI change ratio and serum calcium change ratio at either timepoint (p > 0.05). Conclusion The eLSCI system enables real-time quantitative assessment of intraoperative parathyroid perfusion and demonstrates feasibility in predicting postoperative parathyroid function, holding significant potential for clinical application.
- 3 December 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 508
Open AccessEndoscopic laser speckle imaging enables real-time prediction of parathyroid function in thyroidectomy
Purpose To evaluate the clinical utility of endoscopic laser speckle contrast imaging (eLSCI) for intraoperative assessment of parathyroid gland (PTG) perfusion and functional preservation. Methods Fifteen patients undergoing unilateral/bilateral thyroidectomy at The Affiliated Lihuili Hospital of Ningbo University (November 2024 to April 2025) were prospectively enrolled. PTG perfusion was quantified using eLSCI by recording blood flow index (BFI) before and after thyroid resection. Serum parathyroid hormone (PTH) and calcium levels were measured preoperatively, at 15-min post-resection, and 24-h postoperatively. Pearson correlation analysis was used to assess the linear association between perfusion and functional parameters, while Spearman's rank correlation test was concurrently performed to verify the robustness. Results A significant correlation existed between the BFI change ratio and PTH change ratio at 15-min post-resection (r = 0.672, p = 0.006) and 24-h postoperatively (r = 0.671, p = 0.006). No significant correlation was observed between BFI change ratio and serum calcium change ratio at either timepoint (p > 0.05). Conclusion The eLSCI system enables real-time quantitative assessment of intraoperative parathyroid perfusion and demonstrates feasibility in predicting postoperative parathyroid function, holding significant potential for clinical application.
- Open Access
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 17 (4) , 1-9
A Lithium Niobate (LiNbO3) - Chalcogenide-Based Thin Film Composite Asymmetric Y-Type On-Chip Wavelength Division Multiplexer
This study presents an on-chip dual-mode multiplexer based on a lithium niobate-sulfide thin-film composite adiabatic coupler. The device integrates two input waveguides with distinct structures into a shared output waveguide, enabling selective mode conversion and combination through precise manipulation of the refractive index distribution. Simulation results demonstrate that the device functions across a broad wavelength range of 1500-1600 nm, achieving a wideband operation with crosstalk below 17 dB and insertion loss under 1.36 dB. Tolerance analysis reveals that the device maintains satisfactory performance even with variations in etching depth and waveguide gap within a ±50 nm range. Experimental results show that the overall coupling efficiency of the device is approximately -27 dB.
- 22 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 17 (4) , 1-9
Open AccessA Lithium Niobate (LiNbO3) - Chalcogenide-Based Thin Film Composite Asymmetric Y-Type On-Chip Wavelength Division Multiplexer
This study presents an on-chip dual-mode multiplexer based on a lithium niobate-sulfide thin-film composite adiabatic coupler. The device integrates two input waveguides with distinct structures into a shared output waveguide, enabling selective mode conversion and combination through precise manipulation of the refractive index distribution. Simulation results demonstrate that the device functions across a broad wavelength range of 1500-1600 nm, achieving a wideband operation with crosstalk below 17 dB and insertion loss under 1.36 dB. Tolerance analysis reveals that the device maintains satisfactory performance even with variations in etching depth and waveguide gap within a ±50 nm range. Experimental results show that the overall coupling efficiency of the device is approximately -27 dB.
- 18 September 2024
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 646
Study on the effect of annealing temperature on the optical characteristics and microstructure of Sb2Se3 thin films
- 18 September 2024
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 646
Study on the effect of annealing temperature on the optical characteristics and microstructure of Sb2Se3 thin films
- 31 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (17) , 4492-4500
Fast high-precision 3D shape measurement using linear phase encoding with geometry constraints
A three-dimensional (3D) profile measurement method based on geometric constraints combined with linear phase encoding (GCPE) is proposed. This method encodes the wrapped phase and the linear signal in the same phase domain, achieves the elimination of the phase ambiguity within the local fringe period, and obtains an unambiguous absolute phase within the entire period through geometric constraints. Compared with the traditional phase encoding method, this method solves the problem of period sequence errors caused by a large number of codewords by encoding linear signals in the phase domain and using a period order correction method to deal with the period jump phenomenon caused by noise. At the same time, the measurement range of the fringe projection system under geometric constraints is significantly improved. Experimentally, 3D profiles of standard planes, complex statues, and separated objects were measured by the use of the GCPE. The results show that the GCPE has the advantage of fast speed and high accuracy in measuring the 3D profile of objects.
- 31 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (17) , 4492-4500
Fast high-precision 3D shape measurement using linear phase encoding with geometry constraints
A three-dimensional (3D) profile measurement method based on geometric constraints combined with linear phase encoding (GCPE) is proposed. This method encodes the wrapped phase and the linear signal in the same phase domain, achieves the elimination of the phase ambiguity within the local fringe period, and obtains an unambiguous absolute phase within the entire period through geometric constraints. Compared with the traditional phase encoding method, this method solves the problem of period sequence errors caused by a large number of codewords by encoding linear signals in the phase domain and using a period order correction method to deal with the period jump phenomenon caused by noise. At the same time, the measurement range of the fringe projection system under geometric constraints is significantly improved. Experimentally, 3D profiles of standard planes, complex statues, and separated objects were measured by the use of the GCPE. The results show that the GCPE has the advantage of fast speed and high accuracy in measuring the 3D profile of objects.
- Open Access
Study of Multi-Channel Mode-Division Multiplexing Based on a Chalcogenide-Lithium Niobate Platform
A multi-channel mode-division multiplexing based on a chalcogenide-lithium niobate platform using chalcogenide films with adjustable refractive index is proposed, with the aim of overcoming issues with narrow bandwidth and large crosstalk in conventional multiplexers. An asymmetric directional coupler, employing chalcogenide-based thin-film modulation, was designed to realize the multiplexing and separation of TE1, TE2, and TE3 modes. Simulations show that the device is capable of obtaining an insertion loss of between 0.03 dB and 0.7 dB and a crosstalk of between −21.66 dB and −28.71 dB at 1550 nm. The crosstalk of the TE1, TE2, and TE3 modes is below −20.1 dB when accessing the waveguide output port in the 1500–1600 nm band. The proposed multiplexer is a promising approach to enhance the transmission capability of thin-film lithium-niobate-integrated optical paths.
Open AccessStudy of Multi-Channel Mode-Division Multiplexing Based on a Chalcogenide-Lithium Niobate Platform
A multi-channel mode-division multiplexing based on a chalcogenide-lithium niobate platform using chalcogenide films with adjustable refractive index is proposed, with the aim of overcoming issues with narrow bandwidth and large crosstalk in conventional multiplexers. An asymmetric directional coupler, employing chalcogenide-based thin-film modulation, was designed to realize the multiplexing and separation of TE1, TE2, and TE3 modes. Simulations show that the device is capable of obtaining an insertion loss of between 0.03 dB and 0.7 dB and a crosstalk of between −21.66 dB and −28.71 dB at 1550 nm. The crosstalk of the TE1, TE2, and TE3 modes is below −20.1 dB when accessing the waveguide output port in the 1500–1600 nm band. The proposed multiplexer is a promising approach to enhance the transmission capability of thin-film lithium-niobate-integrated optical paths.
- 1 June 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 166
Effect of femtosecond laser irradiation on photostability of chalcogenide thinfilms within a Ge-S binary system
- 1 June 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 166
Effect of femtosecond laser irradiation on photostability of chalcogenide thinfilms within a Ge-S binary system
- 10 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (15) , 5169-5180
Simultaneous Detection of Temperature, Strain, Refractive Index, and pH Based on a Phase-Shifted Long-Period Fiber Grating
A novel π-phase-shifted (PS) long-period fiber-grating (LPFG) sensor operating near the phase-matching turning point (PMTP) was proposed. The PS-LPFG sensor can simultaneously detect temperature, strain, refractive index (RI), and pH. Due to the introduction of π phase shift, the double resonance peak of the selected cladding mode was divided into four loss peaks, which is convenient for multiparameter measurement. By monitoring the resonant-wavelength shifts of four dips of PS-LPFG, simultaneous detection of temperature, strain, RI, and pH can be achieved. Moreover, using a simple LPFG design on one fiber and a multiparameter matrix algorithm, the crosstalk between multiple signals was eliminated. Graphene oxide/polyvinyl alcohol (GO/PVA) hydrogel was coated onto the grating sensing area to measure the change in pH, and the sensitivity was higher than that of the same type of fiber-grating sensor. Results showed that the maximum sensitivity of temperature, strain, RI, and pH of the fabricated phase-shifted grating sensing structure were 0.2128 nm/°C, 0.1225 nm/μϵ, 718 nm/RIU, and -1.0166 nm/pH, respectively. Overall, the proposed sensor had great potential applications in monitoring marine environments and biochemistry sensing.
- 10 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (15) , 5169-5180
Simultaneous Detection of Temperature, Strain, Refractive Index, and pH Based on a Phase-Shifted Long-Period Fiber Grating
A novel π-phase-shifted (PS) long-period fiber-grating (LPFG) sensor operating near the phase-matching turning point (PMTP) was proposed. The PS-LPFG sensor can simultaneously detect temperature, strain, refractive index (RI), and pH. Due to the introduction of π phase shift, the double resonance peak of the selected cladding mode was divided into four loss peaks, which is convenient for multiparameter measurement. By monitoring the resonant-wavelength shifts of four dips of PS-LPFG, simultaneous detection of temperature, strain, RI, and pH can be achieved. Moreover, using a simple LPFG design on one fiber and a multiparameter matrix algorithm, the crosstalk between multiple signals was eliminated. Graphene oxide/polyvinyl alcohol (GO/PVA) hydrogel was coated onto the grating sensing area to measure the change in pH, and the sensitivity was higher than that of the same type of fiber-grating sensor. Results showed that the maximum sensitivity of temperature, strain, RI, and pH of the fabricated phase-shifted grating sensing structure were 0.2128 nm/°C, 0.1225 nm/μϵ, 718 nm/RIU, and -1.0166 nm/pH, respectively. Overall, the proposed sensor had great potential applications in monitoring marine environments and biochemistry sensing.
- 22 February 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 162
Two-step calibration method for obtaining the optical constants of crystallized chalcogenide films
- 22 February 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 162
Two-step calibration method for obtaining the optical constants of crystallized chalcogenide films