Changjie Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changjie Liu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Luhua Fu
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
6 shared publications Yan Zhao
Tianjin Univ. (China)
4 shared publicationsZhong Wang
Tianjin Univ. (China)
4 shared publications- Zhong Wang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
3 shared publications Changku Sun
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications- Lei Wang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications
Latest Publications
- Open Access
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 68158-68168
A Novel Six-Probe Method for the Measurement and Exact Reconstruction of a Pair of Parallel Profiles
A novel system and its corresponding method for the measurement and the exact reconstruction of a pair of parallel profiles are designed. There are six sensors installed on the measuring device and they are divided into two groups with different sensor spacings. The exact reconstruction can be realized under the condition of a high lateral resolution, as the straightness error, the yaw error, the zeroadjustment error, and the data processing error can be all eliminated through two scannings and certain data processing method. The measurement error of the displacement sensors can also be suppressed. The new method has the following advantages: (i) the realization of the exact reconstruction, (ii) a high lateral resolution of the reconstruction result which is independent of the sensor spacings, (iii) the skip of the zero calibration before the measurement process, and (iv) the suppression of the sensor random error. These advantages are demonstrated by the theoretical analyses and the simulations. Experiments are also conducted to prove some of these characteristics.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 68158-68168
Open AccessA Novel Six-Probe Method for the Measurement and Exact Reconstruction of a Pair of Parallel Profiles
A novel system and its corresponding method for the measurement and the exact reconstruction of a pair of parallel profiles are designed. There are six sensors installed on the measuring device and they are divided into two groups with different sensor spacings. The exact reconstruction can be realized under the condition of a high lateral resolution, as the straightness error, the yaw error, the zeroadjustment error, and the data processing error can be all eliminated through two scannings and certain data processing method. The measurement error of the displacement sensors can also be suppressed. The new method has the following advantages: (i) the realization of the exact reconstruction, (ii) a high lateral resolution of the reconstruction result which is independent of the sensor spacings, (iii) the skip of the zero calibration before the measurement process, and (iv) the suppression of the sensor random error. These advantages are demonstrated by the theoretical analyses and the simulations. Experiments are also conducted to prove some of these characteristics.
- Open Access
- 30 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5216
A Four-Probe Method Using Different Probe Spacings for Measurement and Exact Reconstruction of Parallel Profiles
To realize the measurement and exact reconstruction of a pair of parallel profiles, a new scanning method using four displacement sensors as probes and different probe spacings has been invented with the advantage of preventing data processing error. The measuring device is placed between the measured objects and moved by a scanning stage to collect measurement data of both measured profiles. Considering many existing methods, the high lateral resolution of the reconstruction result and the rejection of the data processing error cannot always be achieved at the same time. When the measured profiles are in the short wavelength range, data processing errors are often on the same order of magnitude as the height difference of the measured profiles. The new method can eliminate both the straightness error of the measurement reference and the data processing error. The exact reconstruction retaining the high lateral resolution and without data processing error can be realized by rational position arrangement of sensors and corresponding processing method of the measurement data. The new method possesses the following advantages: (i) achievement of the exact reconstruction without data processing error; (ii) high lateral resolution not limited by probe spacing; (iii) concise operation without zero calibration of probes; and (iv) suitability for on-machine measurement. The feasibility and advantages of the new method were demonstrated by theoretical analyses, simulations, and experimental results.
- 30 November 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (23) , 5216
Open AccessA Four-Probe Method Using Different Probe Spacings for Measurement and Exact Reconstruction of Parallel Profiles
To realize the measurement and exact reconstruction of a pair of parallel profiles, a new scanning method using four displacement sensors as probes and different probe spacings has been invented with the advantage of preventing data processing error. The measuring device is placed between the measured objects and moved by a scanning stage to collect measurement data of both measured profiles. Considering many existing methods, the high lateral resolution of the reconstruction result and the rejection of the data processing error cannot always be achieved at the same time. When the measured profiles are in the short wavelength range, data processing errors are often on the same order of magnitude as the height difference of the measured profiles. The new method can eliminate both the straightness error of the measurement reference and the data processing error. The exact reconstruction retaining the high lateral resolution and without data processing error can be realized by rational position arrangement of sensors and corresponding processing method of the measurement data. The new method possesses the following advantages: (i) achievement of the exact reconstruction without data processing error; (ii) high lateral resolution not limited by probe spacing; (iii) concise operation without zero calibration of probes; and (iv) suitability for on-machine measurement. The feasibility and advantages of the new method were demonstrated by theoretical analyses, simulations, and experimental results.
- Open Access
Multi-Sensor Registration in High-Precision CMM Based on a Composite Standard
Registration is a critical step in multi-sensor dimensional measurement. As the accuracy of registration directly impacts the quality of final results, a reference sphere as a common standard is problematic in high-precision registration. In this paper, a novel method based on a composite standard is proposed to fuse the multiple heterogeneous sensors in high-precision coordinate measuring machines (CMMs), which will void the drawbacks of a reference sphere. The composite standard consists of a cone and cylinder, which share a same central axis. To ensure high precision in the submicron range, or better, the standard is manufactured by an ultra-precision machine. Three features of the composite standard are inspected by three sensors: a video camera (VC), a tactile probe (TP), and a chromatic confocal displacement sensor (CC). All features will concentrate on a common point through which the relation between the three sensors will be obtained. The errors of each measurement were analyzed theoretically, and simulations and real experiments were carried out to verify the composite standard. This study demonstrates that the proposed registration method is stable and that the standard has potential use for the registration of multiple sensors in high-precision dimensional measurement.
Open AccessMulti-Sensor Registration in High-Precision CMM Based on a Composite Standard
Registration is a critical step in multi-sensor dimensional measurement. As the accuracy of registration directly impacts the quality of final results, a reference sphere as a common standard is problematic in high-precision registration. In this paper, a novel method based on a composite standard is proposed to fuse the multiple heterogeneous sensors in high-precision coordinate measuring machines (CMMs), which will void the drawbacks of a reference sphere. The composite standard consists of a cone and cylinder, which share a same central axis. To ensure high precision in the submicron range, or better, the standard is manufactured by an ultra-precision machine. Three features of the composite standard are inspected by three sensors: a video camera (VC), a tactile probe (TP), and a chromatic confocal displacement sensor (CC). All features will concentrate on a common point through which the relation between the three sensors will be obtained. The errors of each measurement were analyzed theoretically, and simulations and real experiments were carried out to verify the composite standard. This study demonstrates that the proposed registration method is stable and that the standard has potential use for the registration of multiple sensors in high-precision dimensional measurement.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621
Relative position calibration of multi-LDS in shaft center measurement system
In the center measuring device consisting of a plurality of laser triangular displacement sensors (LDS) for coaxiality measurement of shaft, it fits the center coordinate of the shaft by obtaining the coordinates of the outer contour, this poses a higher requirement for the relative position calibration accuracy of the multi-LDS. Aiming at the positional relationship between multi-LDS, the CMM is leaded into the calibration of the center measuring device. Randomly moves a standard column and reading the length values of multi-LDS, combined with the known center coordinates of the column from CMM, to establish the over-determined nonlinear equations, the angle and starting position of the laser beam of each LDS in the measuring device are calculated. The experiment result indicates that measuring uncertainty of the system is 30 μm, this proved the validity and feasibility of the multi-LDS center measuring device in the use of coaxiality measurement of shaft. As a result, it is found that the proposed calibration method is accuracy to the multi-LDS center measuring device and can be implemented easily.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621
Relative position calibration of multi-LDS in shaft center measurement system
In the center measuring device consisting of a plurality of laser triangular displacement sensors (LDS) for coaxiality measurement of shaft, it fits the center coordinate of the shaft by obtaining the coordinates of the outer contour, this poses a higher requirement for the relative position calibration accuracy of the multi-LDS. Aiming at the positional relationship between multi-LDS, the CMM is leaded into the calibration of the center measuring device. Randomly moves a standard column and reading the length values of multi-LDS, combined with the known center coordinates of the column from CMM, to establish the over-determined nonlinear equations, the angle and starting position of the laser beam of each LDS in the measuring device are calculated. The experiment result indicates that measuring uncertainty of the system is 30 μm, this proved the validity and feasibility of the multi-LDS center measuring device in the use of coaxiality measurement of shaft. As a result, it is found that the proposed calibration method is accuracy to the multi-LDS center measuring device and can be implemented easily.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621, 106211C
Parallelism measurement for base plate of standard artifact with multiple tactile approaches
Nowadays, as workpieces become more precise and more specialized which results in more sophisticated structures and higher accuracy for the artifacts, higher requirements have been put forward for measuring accuracy and measuring methods. As an important method to obtain the size of workpieces, coordinate measuring machine (CMM) has been widely used in many industries. In order to achieve the calibration of a self-developed CMM, it is found that the parallelism of the base plate used for fixing the standard artifact is an important factor which affects the measurement accuracy in the process of studying self-made high-precision standard artifact. And aimed to measure the parallelism of the base plate, by using the existing high-precision CMM, gauge blocks, dial gauge and marble platform with the tactile approach, three methods for parallelism measurement of workpieces are employed, and comparisons are made within the measurement results. The results of experiments show that the final accuracy of all the three methods is able to reach micron level and meets the measurement requirements. Simultaneously, these three approaches are suitable for different measurement conditions which provide a basis for rapid and high-precision measurement under different equipment conditions.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621, 106211C
Parallelism measurement for base plate of standard artifact with multiple tactile approaches
Nowadays, as workpieces become more precise and more specialized which results in more sophisticated structures and higher accuracy for the artifacts, higher requirements have been put forward for measuring accuracy and measuring methods. As an important method to obtain the size of workpieces, coordinate measuring machine (CMM) has been widely used in many industries. In order to achieve the calibration of a self-developed CMM, it is found that the parallelism of the base plate used for fixing the standard artifact is an important factor which affects the measurement accuracy in the process of studying self-made high-precision standard artifact. And aimed to measure the parallelism of the base plate, by using the existing high-precision CMM, gauge blocks, dial gauge and marble platform with the tactile approach, three methods for parallelism measurement of workpieces are employed, and comparisons are made within the measurement results. The results of experiments show that the final accuracy of all the three methods is able to reach micron level and meets the measurement requirements. Simultaneously, these three approaches are suitable for different measurement conditions which provide a basis for rapid and high-precision measurement under different equipment conditions.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621
An in-situ measuring method for planar straightness error
According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.
- 12 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10621
An in-situ measuring method for planar straightness error
According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.
- 14 September 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (10) , 105012
A new method for registration of heterogeneous sensors in a dimensional measurement system
Registration of multiple sensors is a basic step in multi-sensor dimensional or coordinate measuring systems before any measurement. In most cases, a common standard is used to be measured by all sensors, and this may work well for general registration of multiple homogeneous sensors. However, when inhomogeneous sensors detect a common standard, it is usually very difficult to obtain the same information, because of the different working principles of the sensors. In this paper, a new method called multiple steps registration is proposed to register two sensors: a video camera sensor (VCS) and a tactile probe sensor (TPS). In this method, the two sensors measure two separated standards: a chrome circle on a reticle and a reference sphere with a constant distance between them, fixed on a steel plate. The VCS captures only the circle and the TPS touches only the sphere. Both simulations and real experiments demonstrate that the proposed method is robust and accurate in the registration of multiple inhomogeneous sensors in a dimensional measurement system.
- 14 September 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (10) , 105012
A new method for registration of heterogeneous sensors in a dimensional measurement system
Registration of multiple sensors is a basic step in multi-sensor dimensional or coordinate measuring systems before any measurement. In most cases, a common standard is used to be measured by all sensors, and this may work well for general registration of multiple homogeneous sensors. However, when inhomogeneous sensors detect a common standard, it is usually very difficult to obtain the same information, because of the different working principles of the sensors. In this paper, a new method called multiple steps registration is proposed to register two sensors: a video camera sensor (VCS) and a tactile probe sensor (TPS). In this method, the two sensors measure two separated standards: a chrome circle on a reticle and a reference sphere with a constant distance between them, fixed on a steel plate. The VCS captures only the circle and the TPS touches only the sphere. Both simulations and real experiments demonstrate that the proposed method is robust and accurate in the registration of multiple inhomogeneous sensors in a dimensional measurement system.
- Open Access
A Fast Measuring Method for the Inner Diameter of Coaxial Holes
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod’s rotation angles, so all diameters of coaxial holes can be calculated by sensors’ values. While revolving, the changing angles of each sensor’s laser beams are approximately equal in the rod’s radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS’s mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use.
Open AccessA Fast Measuring Method for the Inner Diameter of Coaxial Holes
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod’s rotation angles, so all diameters of coaxial holes can be calculated by sensors’ values. While revolving, the changing angles of each sensor’s laser beams are approximately equal in the rod’s radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS’s mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use.
- Open Access
Calibration of Laser Beam Direction for Inner Diameter Measuring Device
The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors’ distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from to and the relative error was not more than 0.011%.Open AccessCalibration of Laser Beam Direction for Inner Diameter Measuring Device
The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors’ distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from to and the relative error was not more than 0.011%.