SFStanley Fan

Stanley Fan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stanley Fan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Peritoneal Dialysis Prescription

    by Stanley Fan, Nasreen Samad

  • Clinical Value of Screening Peritoneal Dialysis Patients for Bacterial Colonization or Contamination

    by Rajeevalochana Parthasarathy, Tasnuva Kashem, Caoimhe NicFhogartaigh, Mark Melzer, Stanley L. Fan

    Introduction: The adoption of the International Society for Peritoneal Dialysis guideline of using mupirocin ointment has been limited by fear of developing mupirocin-resistant organisms. We performed a surveillance program of a large peritoneal dialysis (PD) unit. Methods: We performed 1,175 surveillance swabs from anterior nares, PD catheter exit site, groin, and axilla, from 240 patients. The mean interval between swabs was 3.3 months. Results: Colonization by Staphylococcus aureus ( S. aureus) or Pseudomonas species was 9.5% and 10.9%, respectively. Despite adopting a universal policy of applying mupirocin to PD catheter exit sites in 2001, no instances of mupirocin-resistant S. aureus were identified. Moreover, patients who grew S. aureus from surveillance swabs did not experience higher peritonitis rates than those with “no growth.” This was in contrast to patients who grew Pseudomonas or enteric organisms. There were no differences in patient demographics for those who grew S. aureus, Pseudomonas, or enteric organisms (compared with “no-growth” patients). Conclusion: Our results suggest that the application of mupirocin ointment appeared to minimize peritonitis of patients colonized with S. aureus. The use of mupirocin in this patient cohort has not led to mupirocin resistance. The increased peritonitis rate of patients who grew Pseudomonas or enteric organisms is of interest. We propose that greater attention to hygiene and catheter care in these patients is warranted. The increasing use of paid healthcare workers attending patients daily to help perform PD (assisted PD) gives an opportunity for us to address these wider issues.


  • Clinical value of body composition monitor to evaluate lean and fat tissue mass in peritoneal dialysis

    by Rajeevalochana Parthasarathy, Elizabeth Oei, Stanley L. Fan

    Bioimpedance analysis is often routinely performed in any dialysis unit to guide fluid management but can provide a reproduceable assessment of fat and muscle mass. We wished to determine the clinical significance of low muscle or high fat mass and the determinants that influence their change. We performed retrospective analysis of 824 patients on peritoneal dialysis who underwent routine repeated bioimpedance analysis measurements using the body composition monitor (BCM). Lean tissue index (LTI) was an independent predictor of mortality when sex, age, PD vintage and diabetes status were included in the models (HR 0.93; 95% CI 0.86–1.00, p < 0.05) and when baseline serum albumin was included in a separate model (HR 0.86; 95% CI: 0.79–0.93, p < 0.001). High fat tissue index (FTI) was an independent predictor of mortality when demographic factors were included (HR 0.87; 95% CI: 0.78–0.97, p < 0.02), but not with the addition biochemical parameters. Changes in body composition of 206 patients over a 2-year follow-up period could not be predicted by baseline demographics, functional or biochemical assessments. However, there was a strong inverse relationship between changes in LTI and FTI. There were no associations between changes in body composition with prescribed dialysate glucose. We showed body composition changes are common and complex. LTI was an independent predictor of survival. Changes in LTI and FTI could not be predicted by baseline parameters. BCM may be a sensitive and accurate tool to monitor changes in body composition during dialysis treatment.


  • Comparison of skin autofluorescence, a marker of tissue advanced glycation end‐products in peritoneal dialysis patients using standard and biocompatible glucose containing peritoneal dialysates

    by Surachet Vongsanim, Stanley Fan, Andrew Davenport

    Background: Heat sterilization of peritoneal dialysis (PD) dialysates leads to the generation of advanced glycation products (AGE), which can then deposit in the skin and be measured by skin autofluorescence (SAF). Newer biocompatible dual chamber dialysates contain less AGE. We wished to determine whether the use of these newer dialysates resulted in lower SAF. Methods: Skin autofluorescence was measured using the AGE reader, which directs ultraviolet light, intensity range 300–420 nm (peak 370 nm) in patients established on PD for >3 months using glucose containing dialysates. Results: We screened 196 consecutive patients, and measured SAF in 150; 86 (57.3%) male, median age 62 (53–71) years, median duration of PD treatment 17 (8.6–34.3) months. The median SAF was 3.48 (2.92–4.26) AU. The median SAF in the 57 (38%) patients prescribed biocompatible dual chamber bag dialysates was 3.39 (2.69–3.98) versus 3.5 (3.05–4.54) for those using standard dialysates ( P = 0.044). Although prescription of biocompatible fluids was associated with SAF on univariate analysis, but not on multivariable testing, SAF was independently associated with Stoke–Davies co‐morbidity grade ( β 0.045, 95% confidence limits (CL) 0.015–0.075, P = 0.002), log duration of PD therapy ( β 0.051, CL 0.001–0.101, P = 0.045), white ethnicity ( β 0.066, CL 0.028–0.104, P = 0.001), and negatively with serum albumin ( β −0.006, CL −0.008 to −0.004, P = 0.014). Conclusion: Although SAF was lower in PD patients prescribed biocompatible dual chamber dialysates, on multivariable testing these dialysates were not independently associated with SAF. Other factors than PD fluid AGE content appear more important in determining SAF.