Matthias Luethi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Luethi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Ereditato
University of Chicago
3 shared publications - Damian Goeldi
Institute for Particle Physics and Astrophysics, ETH Zurich, 8093 Zurich, Switzerland
3 shared publications - David Lorca
Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern, 3012 Bern, Switzerland
3 shared publications - Igor Kreslo
University of Bern
3 shared publications - James Sinclair
SLAC National Accelerator Laboratory
3 shared publications - Michael S. Weber
University of Bern
3 shared publications
Latest Publications
- Open Access
- 23 March 2020
- Published by MDPI AG in Instruments
- Vol. 4 (1) , 9
First Demonstration of a Pixelated Charge Readout for Single-Phase Liquid Argon Time Projection Chambers
Traditional charge readout technologies of single-phase Liquid Argon Time projection Chambers (LArTPCs) based on projective wire readout introduce intrinsic ambiguities in event reconstruction. Combined with the slow response inherent in LArTPC detectors, reconstruction ambiguities have limited their performance, until now. Here, we present a proof of principle of a pixelated charge readout that enables the full 3D tracking capabilities of LArTPCs. We characterize the signal-to-noise ratio of charge readout chain to be about 14, and demonstrate track reconstruction on 3D space points produced by the pixel readout. This pixelated charge readout makes LArTPCs a viable option for high-multiplicity environments.
- 23 March 2020
- Published by MDPI AG in Instruments
- Vol. 4 (1) , 9
Open AccessFirst Demonstration of a Pixelated Charge Readout for Single-Phase Liquid Argon Time Projection Chambers
Traditional charge readout technologies of single-phase Liquid Argon Time projection Chambers (LArTPCs) based on projective wire readout introduce intrinsic ambiguities in event reconstruction. Combined with the slow response inherent in LArTPC detectors, reconstruction ambiguities have limited their performance, until now. Here, we present a proof of principle of a pixelated charge readout that enables the full 3D tracking capabilities of LArTPCs. We characterize the signal-to-noise ratio of charge readout chain to be about 14, and demonstrate track reconstruction on 3D space points produced by the pixel readout. This pixelated charge readout makes LArTPCs a viable option for high-multiplicity environments.
- Open Access
- 6 February 2018
- Published by MDPI AG in Instruments
- Vol. 2 (1) , 3
ArCLight—A Compact Dielectric Large-Area Photon Detector
ArgonCube Light readout system (ArCLight) is a novel device for detecting scintillation light over large areas with Photon Detection Efficiency (PDE) of the order of a few percent. Its robust technological design allows for efficient use in large-volume particle detectors, such as Liquid Argon Time Projection Chambers (LArTPCs) or liquid scintillator detectors. Due to its dielectric structure it can be placed inside volumes with high electric field. It could potentially replace vacuum PhotoMultiplier Tubes (PMTs) in applications where high PDE is not required. The photon detection efficiency for a 10 × 10 cm2 detector prototype was measured to be in the range of 0.8% to 2.2% across the active area.
- 6 February 2018
- Published by MDPI AG in Instruments
- Vol. 2 (1) , 3
Open AccessArCLight—A Compact Dielectric Large-Area Photon Detector
ArgonCube Light readout system (ArCLight) is a novel device for detecting scintillation light over large areas with Photon Detection Efficiency (PDE) of the order of a few percent. Its robust technological design allows for efficient use in large-volume particle detectors, such as Liquid Argon Time Projection Chambers (LArTPCs) or liquid scintillator detectors. Due to its dielectric structure it can be placed inside volumes with high electric field. It could potentially replace vacuum PhotoMultiplier Tubes (PMTs) in applications where high PDE is not required. The photon detection efficiency for a 10 × 10 cm2 detector prototype was measured to be in the range of 0.8% to 2.2% across the active area.
- Open Access
- 22 February 2017
- Published by MDPI AG in Instruments
- Vol. 1 (1) , 2
A Novel Cosmic Ray Tagger System for Liquid Argon TPC Neutrino Detectors
The Fermilab Short Baseline Neutrino (SBN) program aims to observe and reconstruct thousands of neutrino-argon interactions with its three detectors (SBND, MicroBooNE, and ICARUS-T600), using their hundred-ton scale Liquid Argon Time Projection Chambers to perform a rich physics analysis program, in particular focused on the search for sterile neutrinos. Given the relatively shallow depth of the detectors, the continuous flux of cosmic ray particles crossing their volumes introduces a constant background which can be falsely identified as part of the event of interest. Here we present the Cosmic Ray Tagger (CRT) system, a novel technique to tag and identify these crossing particles using scintillation modules which measure their time and coordinates relative to the internal events to the neutrino detector, with the intent of mitigating their effect in the event tracking reconstruction.
- 22 February 2017
- Published by MDPI AG in Instruments
- Vol. 1 (1) , 2
Open AccessA Novel Cosmic Ray Tagger System for Liquid Argon TPC Neutrino Detectors
The Fermilab Short Baseline Neutrino (SBN) program aims to observe and reconstruct thousands of neutrino-argon interactions with its three detectors (SBND, MicroBooNE, and ICARUS-T600), using their hundred-ton scale Liquid Argon Time Projection Chambers to perform a rich physics analysis program, in particular focused on the search for sterile neutrinos. Given the relatively shallow depth of the detectors, the continuous flux of cosmic ray particles crossing their volumes introduces a constant background which can be falsely identified as part of the event of interest. Here we present the Cosmic Ray Tagger (CRT) system, a novel technique to tag and identify these crossing particles using scintillation modules which measure their time and coordinates relative to the internal events to the neutrino detector, with the intent of mitigating their effect in the event tracking reconstruction.