GMGabriel Mistelbauer

Gabriel Mistelbauer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabriel Mistelbauer has a total of 138 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep reinforcement learning for automatic anatomic CT landmark localization in Stanford Type B aortic dissection

    by Kathrin Bäumler, Marina Codari, Domenico Mastrodicasa, Gabriel Mistelbauer, Martin J Willemink, Shannon Walters, Virginia Hinostroza, Valery Turner, Leonid Chepelev, Apichaya Sriprachyakul, et al.

    Background: Long-term aortic dissection monitoring requires consistent, landmark-based measurements over time. Purpose: To evaluate the performance of deep reinforcement learning (DRL) agents for the detection of anatomic landmarks in patients with Stanford Type B aortic dissection (TBAD). Materials and Methods: This is an international retrospective study of 396 CT angiography scans of patients with TBAD from 9 participating sites (mean age 57.6 years ± 13.7/[SD]; 236 male, 160 female). Aortic landmarks, including the aortic annulus and 8 aortic branch vessels, were manually labeled. Additionally, interobserver variability data were collected between 2 observers for 30 scans. DRL agents were trained independently for each landmark with the manual labels serving as the reference standard. Unique landmark locations were obtained from (1) single agents’ predictions and (2) clusters of landmark predictions using the DBSCAN clustering algorithm. The performance was analyzed based on distance metrics (mean, median, quantiles) and failure rates, defined as a distance error of more than 10 mm. Interobserver variability data were analyzed with a pairwise Wilcoxon test. Results: On the internal test set, DRL single agents predicted landmark locations with median errors of 2.7 (95% CI, 2.2-3.3) mm and 4.8% failure rate. Cluster-based predictions resulted in a median error of 2.5 (95% CI, 2.4-2.7) mm and 4.0% failure rate. Pooled over all landmarks, cluster-based predictions outperformed single-agent predictions (P < 1e-5). In the external test set, cluster-based DRL models demonstrated significantly lower localization errors and fewer failures compared to single-agent DRL models (P < .01), and were either not significantly different (single agents) from or significantly better (cluster-based, P < .05) than human interobserver variability. The median processing time for a single agent’s prediction was 1.0 second (IQR, 0.7–1.4 seconds). Conclusion: Single-agent and cluster-based DRL predict aortic landmarks in patients with TBAD with high accuracy and precision, comparable to the variability between human observers.


  • Reproducibility of the 2020 Society for Vascular Surgery/Society of Thoracic Surgeons Reporting Standards for Uncomplicated Type B Aortic Dissection

    by Apichaya Sriprachyakul, Domenico Mastrodicasa, Martin J. Willemink, Gabriel Mistelbauer, Jody Shen, Issac Yang, Richard L. Hallett, Sachin B. Malik, Mohammad H. Madani, Kendrick M. Lai, et al.

    Allocation of key type B aortic dissection features to aortic zones, as defined by the 2020 Society for Vascular Surgery/Society of Thoracic Surgeons reporting standards, was poorly reproducible among experienced cardiovascular radiologists and surgeons.


  • Open Access

    Understanding Aortic Dissection Hemodynamics: Evaluating Adapted Smoke Surfaces Against Streakline-Based Techniques

    by Aaron Schroeder, Kai Ostendorf, Kathrin Bäumler, Domenico Mastrodicasa, Dominik Fleischmann, Bernhard Preim, Holger Theisel, Gabriel Mistelbauer

    Aortic dissection is a life-threatening cardiovascular disease characterized by blood entering the media layer of the aortic vessel wall. This creates a second flow channel, known as the false lumen, which weakens the aortic wall and can potentially lead to fatal aortic rupture. Current risk stratification of aortic dissections is primarily based on morphological features of the aorta. However, hemodynamics also play a significant role in disease progression, though their investigation and visualization remain challenging. Common flow visualizations often experience visual clutter, especially when dealing with the intricate morphologies of aortic dissections. In this work, we implement and evaluate different approaches to visualizing the flow in aortic dissections effectively. We employ three techniques, namely streaklines with depth-dependent halos, transparent streaklines, and smoke surfaces. The latter is a technique based on streak surfaces, enhanced with opacity modulations, to produce a smoke-like appearance that improves visual clarity. We adapt the original opacity modulation of smoke surfaces to visualize flow even within the complex geometries of aortic dissections, thereby enhancing visual fidelity. To effectively capture dissection hemodynamics, we developed customized seeding structures that adapt to the shape of the surrounding lumen. Our evaluation, conducted via an online questionnaire, included medical professionals, fluid simulation experts, and visualization specialists. By analyzing results across these groups, we highlight differences in preference and interpretability, offering insight into domain-specific needs. No single visualization technique emerged as the best overall. Smoke surfaces provide the best overall clarity and visual realism. However, participants found streaklines with halos to be the best for quantifying flow, dispite them introducing significant visual clutter. Transparent streaklines serve as a middle ground, offering improved clarity over halos while maintaining some level of detail. Across all participant groups, smoke surfaces were rated as the most visually appealing and lifelike, with medical professionals highlighting their resemblance to contrast-agent injections used in clinical practice.

  • Cardiac CT fractal analysis of LV noncompaction and common cardiomyopathies

    by Ashish Manohar, Ashley Wong, Edgard Castillo, Allison Gunderson, Gabriel Mistelbauer, Shadi Peighambari Bagherzadeh, Francois Haddad, Kadir Caliskan, Ricardo P.J. Budde, Alexander Hirsch, et al.


  • Open Access

    Assessment of Aortic Dissection Remodeling With Patient-Specific Fluid–Structure Interaction Models

    by Kathrin Bäumler, Malte Rolf-Pissarczyk, Richard Schussnig, Thomas-Peter Fries, Gabriel Mistelbauer, Martin R. Pfaller, Alison L. Marsden, Dominik Fleischmann, Gerhard A. Holzapfel

    Aortic dissection leads to late complications due tochronic degeneration and dilatation of the false lumen. This study examines the interaction between hemodynamics and long-term remodeling of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using CT angiography. Fluid–structure interaction models with tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Aortic dilatation was most significant distal to the left subclavian artery, reaching 6 cm in the chronic phase. Simulations quantified the flow jet velocity through the entry tear, which peaked at 185 cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2 mmHg in the subacute and chronic phases, with wall shear stress reaching 4 Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8 mm as disease progressed, which was associated with an overall increase in aortic diameter. Simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5 mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.


  • Open Access

    Automated cross-sectional view selection in CT angiography of aortic dissections with uncertainty awareness and retrospective clinical annotations

    by Antonio Pepe, Jan Egger, Marina Codari, Martin J. Willemink, Christina Gsaxner, Jianning Li, Peter M. Roth, Dieter Schmalstieg, Gabriel Mistelbauer, Dominik Fleischmann


  • Open Access

    Implicit Modeling of Patient‐Specific Aortic Dissections with Elliptic Fourier Descriptors

    by G. Mistelbauer, C. Rössl, K. Bäumler, B. Preim, D. Fleischmann

    Aortic dissection is a life‐threatening vascular disease characterized by abrupt formation of a new flow channel (false lumen) within the aortic wall. Survivors of the acute phase remain at high risk for late complications, such as aneurysm formation, rupture, and death. Morphologic features of aortic dissection determine not only treatment strategies in the acute phase (surgical vs. endovascular vs. medical), but also modulate the hemodynamics in the false lumen, ultimately responsible for late complications. Accurate description of the true and false lumen, any communications across the dissection membrane separating the two lumina, and blood supply from each lumen to aortic branch vessels is critical for risk prediction. Patient‐specific surface representations are also a prerequisite for hemodynamic simulations, but currently require time‐consuming manual segmentation of CT data. We present an aortic dissection cross‐sectional model that captures the varying aortic anatomy, allowing for reliable measurements and creation of high‐quality surface representations. In contrast to the traditional spline‐based cross‐sectional model, we employ elliptic Fourier descriptors, which allows users to control the accuracy of the cross‐sectional contour of a flow channel. We demonstrate (i) how our approach can solve the requirements for generating surface and wall representations of the flow channels, (ii) how any number of communications between flow channels can be specified in a consistent manner, and (iii) how well branches connected to the respective flow channels are handled. Finally, we discuss how our approach is a step forward to an automated generation of surface models for aortic dissections from raw 3D imaging segmentation masks.


  • Semi-automatic vessel detection for challenging cases of peripheral arterial disease

    by Gabriel Mistelbauer, Anca Morar, Rüdiger Schernthaner, Andreas Strassl, Dominik Fleischmann, Florica Moldoveanu, M. Eduard Gröller


  • Semi-supervised Virtual Regression of Aortic Dissections Using 3D Generative Inpainting

    by Antonio Pepe, Gabriel Mistelbauer, Christina Gsaxner, Jianning Li, Dominik Fleischmann, Dieter Schmalstieg, Jan Egger


  • Deep Reinforcement Learning for Localization of the Aortic Annulus in Patients with Aortic Dissection

    by Marina Codari, Antonio Pepe, Gabriel Mistelbauer, Domenico Mastrodicasa, Shannon Walters, Martin J. Willemink, Dominik Fleischmann