Richard B. Fair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard B. Fair has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Vamsee K. Pamula
Duke University
3 shared publications - Ravi Subrahmanyan
Raman Research Institute, Bangalore, India
2 shared publications Andrew C. Madison
1 shared publication- Andrey Khlystov
Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89512, USA
1 shared publication - Carl L. Gardner
Arizona State University
1 shared publication D.J. Rose
Computer Science Department, Duke University, Durham, NC, USA
1 shared publication
Latest Publications
- Open Access
- 15 January 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Design Automation of Electronic Systems
- Vol. 29 (2) , 1-24
Dynamic Adaptation Using Deep Reinforcement Learning for Digital Microfluidic Biochips
We describe an exciting new application domain for deep reinforcement learning (RL): droplet routing on digital microfluidic biochips (DMFBs). A DMFB consists of a two-dimensional electrode array, and it manipulates droplets of liquid to automatically execute biochemical protocols for clinical chemistry. However, a major problem with DMFBs is that electrodes can degrade over time. The transportation of droplet transportation over these degraded electrodes can fail, thereby adversely impacting the integrity of the bioassay outcome. We demonstrated that the formulation of droplet transportation as an RL problem enables the training of deep neural network policies that can adapt to the underlying health conditions of electrodes and ensure reliable fluidic operations. We describe an RL-based droplet routing solution that can be used for various sizes of DMFBs. We highlight the reliable execution of an epigenetic bioassay with the RL droplet router on a fabricated DMFB. We show that the use of the RL approach on a simple micro-computer (Raspberry Pi 4) leads to acceptable performance for time-critical bioassays. We present a simulation environment based on the OpenAI Gym Interface for RL-guided droplet routing problems on DMFBs. We present results on our study of electrode degradation using fabricated DMFBs. The study supports the degradation model used in the simulator.
- 15 January 2024
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Design Automation of Electronic Systems
- Vol. 29 (2) , 1-24
Open AccessDynamic Adaptation Using Deep Reinforcement Learning for Digital Microfluidic Biochips
We describe an exciting new application domain for deep reinforcement learning (RL): droplet routing on digital microfluidic biochips (DMFBs). A DMFB consists of a two-dimensional electrode array, and it manipulates droplets of liquid to automatically execute biochemical protocols for clinical chemistry. However, a major problem with DMFBs is that electrodes can degrade over time. The transportation of droplet transportation over these degraded electrodes can fail, thereby adversely impacting the integrity of the bioassay outcome. We demonstrated that the formulation of droplet transportation as an RL problem enables the training of deep neural network policies that can adapt to the underlying health conditions of electrodes and ensure reliable fluidic operations. We describe an RL-based droplet routing solution that can be used for various sizes of DMFBs. We highlight the reliable execution of an epigenetic bioassay with the RL droplet router on a fabricated DMFB. We show that the use of the RL approach on a simple micro-computer (Raspberry Pi 4) leads to acceptable performance for time-critical bioassays. We present a simulation environment based on the OpenAI Gym Interface for RL-guided droplet routing problems on DMFBs. We present results on our study of electrode degradation using fabricated DMFBs. The study supports the degradation model used in the simulator.
- Open Access
Digital Microfluidics for the Detection of Selected Inorganic Ions in Aerosols
A prototype aerosol detection system is presented that is designed to accurately and quickly measure the concentration of selected inorganic ions in the atmosphere. The aerosol detection system combines digital microfluidics technology, aerosol impaction and chemical detection integrated on the same chip. Target compounds are the major inorganic aerosol constituents: sulfate, nitrate and ammonium. The digital microfluidic system consists of top and bottom plates that sandwich a fluid layer. Nozzles for an inertial impactor are built into the top plate according to known, scaling principles. The deposited air particles are densely concentrated in well-defined deposits on the bottom plate containing droplet actuation electrodes of the chip in fixed areas. The aerosol collection efficiency for particles larger than 100 nm in diameter was higher than 95%. After a collection phase, deposits are dissolved into a scanning droplet. Due to a sub-microliter droplet size, the obtained extract is highly concentrated. Droplets then pass through an air/oil interface on chip for colorimetric analysis by spectrophotometry using optical fibers placed between the two plates of the chip. To create a standard curve for each analyte, six different concentrations of liquid standards were chosen for each assay and dispensed from on-chip reservoirs. The droplet mixing was completed in a few seconds and the final droplet was transported to the detection position as soon as the mixing was finished. Limits of detection (LOD) in the final droplet were determined to be 11 ppm for sulfate and 0.26 ppm for ammonium. For nitrate, it was impossible to get stable measurements. The LOD of the on-chip measurements for sulfate was close to that obtained by an off-chip method using a Tecan spectrometer. LOD of the on-chip method for ammonium was about five times larger than what was obtained with the off-chip method. For the current impactor collection air flow (1 L/min) and 1 h collection time, the converted LODs in air were: 0.275 μg/m3 for sulfate, 6.5 ng/m3 for ammonium, sufficient for most ambient air monitoring applications.
Open AccessDigital Microfluidics for the Detection of Selected Inorganic Ions in Aerosols
A prototype aerosol detection system is presented that is designed to accurately and quickly measure the concentration of selected inorganic ions in the atmosphere. The aerosol detection system combines digital microfluidics technology, aerosol impaction and chemical detection integrated on the same chip. Target compounds are the major inorganic aerosol constituents: sulfate, nitrate and ammonium. The digital microfluidic system consists of top and bottom plates that sandwich a fluid layer. Nozzles for an inertial impactor are built into the top plate according to known, scaling principles. The deposited air particles are densely concentrated in well-defined deposits on the bottom plate containing droplet actuation electrodes of the chip in fixed areas. The aerosol collection efficiency for particles larger than 100 nm in diameter was higher than 95%. After a collection phase, deposits are dissolved into a scanning droplet. Due to a sub-microliter droplet size, the obtained extract is highly concentrated. Droplets then pass through an air/oil interface on chip for colorimetric analysis by spectrophotometry using optical fibers placed between the two plates of the chip. To create a standard curve for each analyte, six different concentrations of liquid standards were chosen for each assay and dispensed from on-chip reservoirs. The droplet mixing was completed in a few seconds and the final droplet was transported to the detection position as soon as the mixing was finished. Limits of detection (LOD) in the final droplet were determined to be 11 ppm for sulfate and 0.26 ppm for ammonium. For nitrate, it was impossible to get stable measurements. The LOD of the on-chip measurements for sulfate was close to that obtained by an off-chip method using a Tecan spectrometer. LOD of the on-chip method for ammonium was about five times larger than what was obtained with the off-chip method. For the current impactor collection air flow (1 L/min) and 1 h collection time, the converted LODs in air were: 0.275 μg/m3 for sulfate, 6.5 ng/m3 for ammonium, sufficient for most ambient air monitoring applications.
- Open Access
- 21 November 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (12) , 1654
Quantitative measurements of inorganic analytes on a digital microfluidics platform
Two methods were studied for selectively measuring the on-chip absorbance of trace sulfate analytes in droplets on a digital microfluidics (DMF) platform. In one method, the direction of measurement was perpendicular to the flat upper and lower surfaces of the DMF platform (vertical), and in the second method, the measurement direction was parallel to the DMF platform surfaces (horizontal). The channel height or the vertical light path length was 0.24 mm, and the droplet diameter was 1 mm. The DMF system employed a silicone oil transport medium whereby a thin, non-uniform oil layer formed between the droplet and the upper/lower plates which was unstable, resulting in randomly formed local oil lenses. The mobile oil lenses caused vertical absorbance measurement errors and uncertainties. The effects of the oil lenses were verified by simulation. Horizontal absorbance measurements were taken with embedded optical fibers (0.2 mm in diameter) aligned over the bottom chip surface in contact with the sides of the droplet, resulting in a horizontal light path length approximately three times that of the vertical light path. Because no oil lenses could form on the droplet’s sides, the stability of repeated horizontal measurements outperformed repeated vertical measurements made on the same droplet and on multiple droplets actuated into the measurement positions. Comparisons were based on measurement standard deviations and limits of detection (LOD). The following LODs and measurement standard deviations were achieved for horizontal measurements of multiple sulfate concentrations in 1.5 µl droplets: 7 ppm for sulfate (0.3–2.7%) and an R2 value of 0.957 from a least square data fit. Measurements on a commercial plate reader gave comparable results (200 µl liquid in each well, LOD equals 11 ppm, CV equals to 0.2–4%), even though the absorbance path was larger (0.7 mm). This LOD value means that the chip could detect 10.5 ng of sulfate. LOD values on vertical measurements were also similar, but large measurement errors from numerous outlier points yielded an R2 value of 0.735 and large average measurement standard deviations (36%).
- 21 November 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (12) , 1654
Open AccessQuantitative measurements of inorganic analytes on a digital microfluidics platform
Two methods were studied for selectively measuring the on-chip absorbance of trace sulfate analytes in droplets on a digital microfluidics (DMF) platform. In one method, the direction of measurement was perpendicular to the flat upper and lower surfaces of the DMF platform (vertical), and in the second method, the measurement direction was parallel to the DMF platform surfaces (horizontal). The channel height or the vertical light path length was 0.24 mm, and the droplet diameter was 1 mm. The DMF system employed a silicone oil transport medium whereby a thin, non-uniform oil layer formed between the droplet and the upper/lower plates which was unstable, resulting in randomly formed local oil lenses. The mobile oil lenses caused vertical absorbance measurement errors and uncertainties. The effects of the oil lenses were verified by simulation. Horizontal absorbance measurements were taken with embedded optical fibers (0.2 mm in diameter) aligned over the bottom chip surface in contact with the sides of the droplet, resulting in a horizontal light path length approximately three times that of the vertical light path. Because no oil lenses could form on the droplet’s sides, the stability of repeated horizontal measurements outperformed repeated vertical measurements made on the same droplet and on multiple droplets actuated into the measurement positions. Comparisons were based on measurement standard deviations and limits of detection (LOD). The following LODs and measurement standard deviations were achieved for horizontal measurements of multiple sulfate concentrations in 1.5 µl droplets: 7 ppm for sulfate (0.3–2.7%) and an R2 value of 0.957 from a least square data fit. Measurements on a commercial plate reader gave comparable results (200 µl liquid in each well, LOD equals 11 ppm, CV equals to 0.2–4%), even though the absorbance path was larger (0.7 mm). This LOD value means that the chip could detect 10.5 ng of sulfate. LOD values on vertical measurements were also similar, but large measurement errors from numerous outlier points yielded an R2 value of 0.735 and large average measurement standard deviations (36%).
- Open Access
- 1 November 2018
- Published by Gavin Publishers in Biosensors and Bioelectronics Open Access
- Vol. 2 (5)
Cell Manipulation and Detection Enhancement Enabled by a Microelectromagnet Integrated with a Digital Microfluidic Device
Journal of Biosensors and Bioelectronics is an open-access, peer-reviewed academic journal that provides high-quality manuscripts relevant and applicable to the broad field of research in the convergence of biology and electronics, and also the detection of an analyte.
- 1 November 2018
- Published by Gavin Publishers in Biosensors and Bioelectronics Open Access
- Vol. 2 (5)
Open AccessCell Manipulation and Detection Enhancement Enabled by a Microelectromagnet Integrated with a Digital Microfluidic Device
Journal of Biosensors and Bioelectronics is an open-access, peer-reviewed academic journal that provides high-quality manuscripts relevant and applicable to the broad field of research in the convergence of biology and electronics, and also the detection of an analyte.
- 1 May 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (5) , 1038-1039
Demonstration of Automated Analysis of Multiple Analytes on an Integrated Digital Microfluidic Platform
Featured Article: Srinivasan V, Pamula V, Fair R. An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids, Lab Chip 2004;4:310–15.2 Our 2004 article highlighted here was the first report of a droplet-based microfluidic device that integrated on a monolithic platform all the functions for analyzing human physiological fluids, including sample injection, on-chip reservoirs, droplet formation structures, fluidic transport, mixing of reagent and sample droplets, and optical detection. The device could also be run by a computer. Thus, the device proved the potential for automated analysis of multiple analytes for clinical diagnostics using a programmable lab-on-a-chip. The use of microfluidic lab-on-a-chip technology for clinical applications in the early 2000 timeframe was almost exclusively based on continuous fluid flow in microchannels. Fluid pumping based on electrokinetic phenomena (electrophoretic separation and electroosmotics), external pressure sources, centrifugal effects, and passive capillary flow were being investigated. However, continuous-flow based devices offered very little flexibility in terms of scalability, reconfigurability, and suitability for use with a variety of liquids. For instance, physiological liquids with high ionic strength, such as blood and urine, could not be pumped using electrokinetic effects due to excessive Joule heating. In addition, continuous flow systems relied on fixed channels through …
- 1 May 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (5) , 1038-1039
Demonstration of Automated Analysis of Multiple Analytes on an Integrated Digital Microfluidic Platform
Featured Article: Srinivasan V, Pamula V, Fair R. An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids, Lab Chip 2004;4:310–15.2 Our 2004 article highlighted here was the first report of a droplet-based microfluidic device that integrated on a monolithic platform all the functions for analyzing human physiological fluids, including sample injection, on-chip reservoirs, droplet formation structures, fluidic transport, mixing of reagent and sample droplets, and optical detection. The device could also be run by a computer. Thus, the device proved the potential for automated analysis of multiple analytes for clinical diagnostics using a programmable lab-on-a-chip. The use of microfluidic lab-on-a-chip technology for clinical applications in the early 2000 timeframe was almost exclusively based on continuous fluid flow in microchannels. Fluid pumping based on electrokinetic phenomena (electrophoretic separation and electroosmotics), external pressure sources, centrifugal effects, and passive capillary flow were being investigated. However, continuous-flow based devices offered very little flexibility in terms of scalability, reconfigurability, and suitability for use with a variety of liquids. For instance, physiological liquids with high ionic strength, such as blood and urine, could not be pumped using electrokinetic effects due to excessive Joule heating. In addition, continuous flow systems relied on fixed channels through …
- 1 April 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 507 (1) , 145-150
Droplet-based microfluidic lab-on-a-chip for glucose detection
- 1 April 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 507 (1) , 145-150
Droplet-based microfluidic lab-on-a-chip for glucose detection
- 22 August 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4038, 547-553
Detection of dissolved TNT and DNT in soil with a MEMS explosive particle detector
MEMS technology was used to fabricate bimetallic cantilever sensor for detecting the TNT and DNT residue found in mien fields. A number of experiments yielded reproducible result for the detection of pure 2,4-Dinitrotoluene nanogram particles. A few experiments were performed unsuccessfully to detect explosives directly from soil by placing it on the cantilevers. Alternatively, DNT and TNT were extracted from the soil using acetone and subsequently letting acetone to leave DNT and TNT as a residue. This residue has been placed on the cantilever for detection that yielded very uncertain result. This residua contains a number of other materials, which changes the physical properties of the residue considerable making it unfit for detection using microcantilevers. T
- 22 August 2000
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4038, 547-553
Detection of dissolved TNT and DNT in soil with a MEMS explosive particle detector
MEMS technology was used to fabricate bimetallic cantilever sensor for detecting the TNT and DNT residue found in mien fields. A number of experiments yielded reproducible result for the detection of pure 2,4-Dinitrotoluene nanogram particles. A few experiments were performed unsuccessfully to detect explosives directly from soil by placing it on the cantilevers. Alternatively, DNT and TNT were extracted from the soil using acetone and subsequently letting acetone to leave DNT and TNT as a residue. This residue has been placed on the cantilever for detection that yielded very uncertain result. This residua contains a number of other materials, which changes the physical properties of the residue considerable making it unfit for detection using microcantilevers. T
- 22 July 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3079, 671-680
MEMS-based explosive particle detection and remote particle stimulation
We report on a new methodology for chemical detection of explosive particles associated with anti-personnel mines. Trace particle detection can be used to complement vapor detection of explosives with an electronic noise. Our approach is to remotely stimulate a target area with a high intensity, focused air ultrasonic beam whose energy can megasonically clean the target area of particles above a designed for size. We have designed a MEMS electrostatic transducer to test the concept. Nanogram particle detection will occur by collecting particles on an array of temperature sensitive MEMS sensors and irradiating the particles with 3-5 micrometers wavelength IR light. Explosive particles will selectively absorb the IR energy at approximately 1600 cm-1, decompose, and give off heat which can be detected.
- 22 July 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3079, 671-680
MEMS-based explosive particle detection and remote particle stimulation
We report on a new methodology for chemical detection of explosive particles associated with anti-personnel mines. Trace particle detection can be used to complement vapor detection of explosives with an electronic noise. Our approach is to remotely stimulate a target area with a high intensity, focused air ultrasonic beam whose energy can megasonically clean the target area of particles above a designed for size. We have designed a MEMS electrostatic transducer to test the concept. Nanogram particle detection will occur by collecting particles on an array of temperature sensitive MEMS sensors and irradiating the particles with 3-5 micrometers wavelength IR light. Explosive particles will selectively absorb the IR energy at approximately 1600 cm-1, decompose, and give off heat which can be detected.
- 1 January 1993
- Published by Springer Nature in MRS Proceedings
- Vol. 300
Junction Formation in Silicon by Rapid Thermal Annealing
- 1 January 1993
- Published by Springer Nature in MRS Proceedings
- Vol. 300
Junction Formation in Silicon by Rapid Thermal Annealing
- 1 January 1992
- Published by Elsevier
- p. 108-112
Diffusion in Silicon