Kaihua Xiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kaihua Xiu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Zong-Ming Li
Hand Research Laboratory, Department of Orthopaedic Surgery, University of Arizona College of Medicine, Tucson, Arizona, USA
4 shared publications - Tamara L. Marquardt
Hand Research Laboratory, Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio
2 shared publications - Chengliu Li
Hand Research Laboratory, Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio
1 shared publication Diana M. Gaitan
Engineered Tissue Mechanics Laboratory, Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania
1 shared publication- Emily L. Grandy
Hand Research Laboratory, Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio
1 shared publication - Ke Li
Shandong University
1 shared publication
Latest Publications
- Open Access
- 1 February 2018
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 38, 197-202
Carpal tunnel syndrome impairs index finger responses to unpredictable perturbations
- 1 February 2018
- Published by Elsevier in Journal of Electromyography and Kinesiology
- Vol. 38, 197-202
Open AccessCarpal tunnel syndrome impairs index finger responses to unpredictable perturbations
- Open Access
- 24 March 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 37 (3) , 328-335
Effects of Carpal Tunnel Syndrome on Force Coordination and Muscle Coherence during Precision Pinch
- 24 March 2017
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 37 (3) , 328-335
Open AccessEffects of Carpal Tunnel Syndrome on Force Coordination and Muscle Coherence during Precision Pinch
- Open Access
- 13 April 2016
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 11 (1) , 1-7
Changes in carpal tunnel compliance with incremental flexor retinaculum release
Flexor retinaculum transection is a routine surgical treatment for carpal tunnel syndrome, yet the biomechanical and clinical sequelae of the procedure remain unclear. We investigated the effects of flexor retinaculum release on carpal tunnel structural compliance using cadaveric hands. The flexor retinaculum was incrementally and sequentially released with transections of 25, 50, 75, and 100 % of the transverse carpal ligament, followed by the distal aponeurosis and then the antebrachial fascia. Paired outward 10 N forces were applied to the insertion sites of the transverse carpal ligament at the distal (hamate-trapezium) and proximal (pisiform-scaphoid) levels of the carpal tunnel. Carpal tunnel compliance was defined as the change in carpal arch width normalized to the constant 10 N force. With the flexor retinaculum intact, carpal tunnel compliance at the proximal level, 0.696 ± 0.128 mm/N, was 13.6 times greater than that at the distal level, 0.056 ± 0.020 mm/N. Complete release of the transverse carpal ligament was required to achieve a significant gain in compliance at the distal level (p < 0.05). Subsequent release of the distal aponeurosis resulted in an appreciable additional increase in compliance (43.0 %, p = 0.052) at the distal level, but a minimal increase (1.7 %, p = 0.987) at the proximal level. Complete flexor retinaculum release provided a significant gain in compliance relative to transverse carpal ligament release alone at both proximal and distal levels (p < 0.05). Overall, complete flexor retinaculum release increased proximal compliance by 52 % and distal compliance by 332 %. The increase in carpal tunnel compliance with complete flexor retinaculum release helps explain the benefit of carpal tunnel release surgery for patients with carpal tunnel syndrome.
- 13 April 2016
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 11 (1) , 1-7
Open AccessChanges in carpal tunnel compliance with incremental flexor retinaculum release
Flexor retinaculum transection is a routine surgical treatment for carpal tunnel syndrome, yet the biomechanical and clinical sequelae of the procedure remain unclear. We investigated the effects of flexor retinaculum release on carpal tunnel structural compliance using cadaveric hands. The flexor retinaculum was incrementally and sequentially released with transections of 25, 50, 75, and 100 % of the transverse carpal ligament, followed by the distal aponeurosis and then the antebrachial fascia. Paired outward 10 N forces were applied to the insertion sites of the transverse carpal ligament at the distal (hamate-trapezium) and proximal (pisiform-scaphoid) levels of the carpal tunnel. Carpal tunnel compliance was defined as the change in carpal arch width normalized to the constant 10 N force. With the flexor retinaculum intact, carpal tunnel compliance at the proximal level, 0.696 ± 0.128 mm/N, was 13.6 times greater than that at the distal level, 0.056 ± 0.020 mm/N. Complete release of the transverse carpal ligament was required to achieve a significant gain in compliance at the distal level (p < 0.05). Subsequent release of the distal aponeurosis resulted in an appreciable additional increase in compliance (43.0 %, p = 0.052) at the distal level, but a minimal increase (1.7 %, p = 0.987) at the proximal level. Complete flexor retinaculum release provided a significant gain in compliance relative to transverse carpal ligament release alone at both proximal and distal levels (p < 0.05). Overall, complete flexor retinaculum release increased proximal compliance by 52 % and distal compliance by 332 %. The increase in carpal tunnel compliance with complete flexor retinaculum release helps explain the benefit of carpal tunnel release surgery for patients with carpal tunnel syndrome.
- 25 August 2011
- Published by Wiley in Clinical Anatomy
- Vol. 25 (4) , 478-482
Fiber orientation of the transverse carpal ligament
The transverse carpal ligament is the volar roof of the carpal tunnel. Gross observation shows that the ligament appears to have fibers that roughly orient in the transverse direction. A closer anatomical examination shows that the ligament also has oblique fibers. Knowledge of the fiber orientation of the transverse carpal ligament is valuable for further understanding the ligament's role in regulating the structural function of the carpal tunnel. The purpose of this study is to quantify collagen fiber orientation within the transverse carpal ligament using the small angle light scattering technique. Eight transverse carpal ligament samples from cadaver hands were used in this study. Individual 20‐μm sections were cut evenly along the thickness of the transverse carpal ligament. Sections of three thickness levels (25%, 50%, and 75% from the volar surface) were collected for each transverse carpal ligament. Fibers were grouped in the following orientation ranges: transverse, longitudinal, oblique in the pisiform‐trapezium (PT), and oblique in the scaphoid‐hamate (SH) directions. In analyzing the fiber percentages, the orientation types for the different thickness levels of the ligament showed that the transverse fibers were the most prominent (>60.7%) followed by the PT oblique (18.6%), SH oblique (13.0%), and longitudinal (8.6%) fibers. Clin. Anat. 25:478–482, 2012.
- 25 August 2011
- Published by Wiley in Clinical Anatomy
- Vol. 25 (4) , 478-482
Fiber orientation of the transverse carpal ligament
The transverse carpal ligament is the volar roof of the carpal tunnel. Gross observation shows that the ligament appears to have fibers that roughly orient in the transverse direction. A closer anatomical examination shows that the ligament also has oblique fibers. Knowledge of the fiber orientation of the transverse carpal ligament is valuable for further understanding the ligament's role in regulating the structural function of the carpal tunnel. The purpose of this study is to quantify collagen fiber orientation within the transverse carpal ligament using the small angle light scattering technique. Eight transverse carpal ligament samples from cadaver hands were used in this study. Individual 20‐μm sections were cut evenly along the thickness of the transverse carpal ligament. Sections of three thickness levels (25%, 50%, and 75% from the volar surface) were collected for each transverse carpal ligament. Fibers were grouped in the following orientation ranges: transverse, longitudinal, oblique in the pisiform‐trapezium (PT), and oblique in the scaphoid‐hamate (SH) directions. In analyzing the fiber percentages, the orientation types for the different thickness levels of the ligament showed that the transverse fibers were the most prominent (>60.7%) followed by the PT oblique (18.6%), SH oblique (13.0%), and longitudinal (8.6%) fibers. Clin. Anat. 25:478–482, 2012.