Sarah Oakley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sarah Oakley has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Derrick W. Crook
Modernising Medical Microbiology Unit, Nuffield Department of Medicine, University of Oxford
6 shared publications - David William Eyre
Nuffield Department of Medicine, University of Oxford, Oxford, UK
4 shared publications - Nicole Stoesser
Nuffield Department of Medicine, University of Oxford
4 shared publications - Timothy Ea Peto
Nuffield Department of Medicine, University of Oxford, Oxford, UK
4 shared publications - Katie Jeffery
Radcliffe Department of Medicine, University of Oxford, Oxford, UK
3 shared publications - Monique Ingrid Andersson
Department of Infectious Diseases and Microbiology Oxford University Hospitals NHS Foundation Trust Oxford UK
3 shared publications
Latest Publications
- Open Access
- 25 September 2025
- Published by Microbiology Society in Microbial Genomics
- Vol. 11 (9) , 001507
Nanopore adaptive sampling for bacterial identification from periprosthetic joint replacement tissue
Metagenomic approaches to the diagnosis of prosthetic joint infections promise more accurate and more rapid diagnosis. However, the high host DNA to bacterial DNA ratio is a challenge. Nanopore adaptive sampling (AS) can be used to preferentially sequence more of the infecting organism. Here, we evaluate AS using clinical samples from infected prosthetic joints to determine the absolute fold enrichment achieved. We found that AS achieved a range of 1.61- to 1.96-fold higher absolute fold enrichment for bacterial sequenced bases using AS over control pores. In this limited sample set, AS did not impact bacterial diagnosis overall but led to a modest increase in the bacterial sequence available without any obvious cost.
- 25 September 2025
- Published by Microbiology Society in Microbial Genomics
- Vol. 11 (9) , 001507
Open AccessNanopore adaptive sampling for bacterial identification from periprosthetic joint replacement tissue
Metagenomic approaches to the diagnosis of prosthetic joint infections promise more accurate and more rapid diagnosis. However, the high host DNA to bacterial DNA ratio is a challenge. Nanopore adaptive sampling (AS) can be used to preferentially sequence more of the infecting organism. Here, we evaluate AS using clinical samples from infected prosthetic joints to determine the absolute fold enrichment achieved. We found that AS achieved a range of 1.61- to 1.96-fold higher absolute fold enrichment for bacterial sequenced bases using AS over control pores. In this limited sample set, AS did not impact bacterial diagnosis overall but led to a modest increase in the bacterial sequence available without any obvious cost.
- Open Access
- 25 October 2024
- Published by Microbiology Society in Microbial Genomics
- Vol. 10 (10) , 001296
Comparison of direct cDNA and PCR-cDNA Nanopore sequencing of RNA from Escherichia coli isolates
Whole-transcriptome (long-read) RNA sequencing (Oxford Nanopore Technologies, ONT) holds promise for reference-agnostic analysis of differential gene expression in pathogenic bacteria, including for antimicrobial resistance genes (ARGs). However, direct cDNA ONT sequencing requires large concentrations of polyadenylated mRNA, and amplification protocols may introduce technical bias. Here we evaluated the impact of direct cDNA- and cDNA PCR-based ONT sequencing on transcriptomic analysis of clinical Escherichia coli. Four E. coli bloodstream infection-associated isolates (n=2 biological replicates per isolate) were sequenced using the ONT Direct cDNA Sequencing SQK-DCS109 and PCR-cDNA Barcoding SQK-PCB111.24 kits. Biological and technical replicates were distributed over eight flow cells using 16 barcodes to minimize batch/barcoding bias. Reads were mapped to a transcript reference and transcript abundance was quantified after in silico depletion of low-abundance and rRNA genes. We found there were strong correlations between read counts using both kits and when restricting the analysis to include only ARGs. We highlighted that correlations were weaker for genes with a higher GC content. Read lengths were longer for the direct cDNA kit compared to the PCR-cDNA kit whereas total yield was higher for the PCR-cDNA kit. In this small but methodologically rigorous evaluation of biological and technical replicates of isolates sequenced with the direct cDNA and PCR-cDNA ONT sequencing kits, we demonstrated that PCR-based amplification substantially improves yield with largely unbiased assessment of core gene and ARG expression. However, users of PCR-based kits should be aware of a small risk of technical bias which appears greater for genes with an unusually high (>52%)/low (<44%) GC content.
- 25 October 2024
- Published by Microbiology Society in Microbial Genomics
- Vol. 10 (10) , 001296
Open AccessComparison of direct cDNA and PCR-cDNA Nanopore sequencing of RNA from Escherichia coli isolates
Whole-transcriptome (long-read) RNA sequencing (Oxford Nanopore Technologies, ONT) holds promise for reference-agnostic analysis of differential gene expression in pathogenic bacteria, including for antimicrobial resistance genes (ARGs). However, direct cDNA ONT sequencing requires large concentrations of polyadenylated mRNA, and amplification protocols may introduce technical bias. Here we evaluated the impact of direct cDNA- and cDNA PCR-based ONT sequencing on transcriptomic analysis of clinical Escherichia coli. Four E. coli bloodstream infection-associated isolates (n=2 biological replicates per isolate) were sequenced using the ONT Direct cDNA Sequencing SQK-DCS109 and PCR-cDNA Barcoding SQK-PCB111.24 kits. Biological and technical replicates were distributed over eight flow cells using 16 barcodes to minimize batch/barcoding bias. Reads were mapped to a transcript reference and transcript abundance was quantified after in silico depletion of low-abundance and rRNA genes. We found there were strong correlations between read counts using both kits and when restricting the analysis to include only ARGs. We highlighted that correlations were weaker for genes with a higher GC content. Read lengths were longer for the direct cDNA kit compared to the PCR-cDNA kit whereas total yield was higher for the PCR-cDNA kit. In this small but methodologically rigorous evaluation of biological and technical replicates of isolates sequenced with the direct cDNA and PCR-cDNA ONT sequencing kits, we demonstrated that PCR-based amplification substantially improves yield with largely unbiased assessment of core gene and ARG expression. However, users of PCR-based kits should be aware of a small risk of technical bias which appears greater for genes with an unusually high (>52%)/low (<44%) GC content.
- Open Access
Ten years of population-level genomic Escherichia coli and Klebsiella pneumoniae serotype surveillance informs vaccine development for invasive infections
The incidence of bloodstream infections (BSIs) caused by Enterobacteriaceae (e.g. Escherichia coli, Klebsiella pneumoniae ) continues to increase globally and the threat of untreatable disease is substantial 1 . Prophylactic vaccines represent an alternative approach to combating antimicrobial resistance (AMR) by reducing antibiotic usage and preventing infections caused by AMR-associated strains. To investigate their potential utility, we performed in silico serotyping on 4035 E. coli / K. pneumoniae BSI from population-level surveillance in Oxfordshire (2008-2018) in addition to 3678 isolates from previous studies. Most infections, including those associated with AMR, were caused by isolates with a small subset of O-antigens, with no evidence that the proportion of BSIs caused by these changed significantly over time. O-antigen targeted vaccines might therefore be useful in reducing the significant morbidity and mortality 2 associated with BSIs. Vaccines may also have a role in preventing the spread of carbapenem resistance genes into common serotypes associated with community-onset disease.
Open AccessTen years of population-level genomic Escherichia coli and Klebsiella pneumoniae serotype surveillance informs vaccine development for invasive infections
The incidence of bloodstream infections (BSIs) caused by Enterobacteriaceae (e.g. Escherichia coli, Klebsiella pneumoniae ) continues to increase globally and the threat of untreatable disease is substantial 1 . Prophylactic vaccines represent an alternative approach to combating antimicrobial resistance (AMR) by reducing antibiotic usage and preventing infections caused by AMR-associated strains. To investigate their potential utility, we performed in silico serotyping on 4035 E. coli / K. pneumoniae BSI from population-level surveillance in Oxfordshire (2008-2018) in addition to 3678 isolates from previous studies. Most infections, including those associated with AMR, were caused by isolates with a small subset of O-antigens, with no evidence that the proportion of BSIs caused by these changed significantly over time. O-antigen targeted vaccines might therefore be useful in reducing the significant morbidity and mortality 2 associated with BSIs. Vaccines may also have a role in preventing the spread of carbapenem resistance genes into common serotypes associated with community-onset disease.
- Open Access
SARS-CoV-2 RNA detected in blood samples from patients with COVID-19 is not associated with infectious virus
Background: Laboratory diagnosis of SARS-CoV-2 infection (the cause of COVID-19) uses PCR to detect viral RNA (vRNA) in respiratory samples. SARS-CoV-2 RNA has also been detected in other sample types, but there is limited understanding of the clinical or laboratory significance of its detection in blood. Methods: We undertook a systematic literature review to assimilate the evidence for the frequency of vRNA in blood, and to identify associated clinical characteristics. We performed RT-PCR in serum samples from a UK clinical cohort of acute and convalescent COVID-19 cases (n=212), together with convalescent plasma samples collected by NHS Blood and Transplant (NHSBT) (n=111 additional samples). To determine whether PCR-positive blood samples could pose an infection risk, we attempted virus isolation from a subset of RNA-positive samples. Results: We identified 28 relevant studies, reporting SARS-CoV-2 RNA in 0-76% of blood samples; pooled estimate 10% (95%CI 5-18%). Among serum samples from our clinical cohort, 27/212 (12.7%) had SARS-CoV-2 RNA detected by RT-PCR. RNA detection occurred in samples up to day 20 post symptom onset, and was associated with more severe disease (multivariable odds ratio 7.5). Across all samples collected ≥28 days post symptom onset, 0/143 (0%, 95%CI 0.0-2.5%) had vRNA detected. Among our PCR-positive samples, cycle threshold (ct) values were high (range 33.5-44.8), suggesting low vRNA copy numbers. PCR-positive sera inoculated into cell culture did not produce any cytopathic effect or yield an increase in detectable SARS-CoV-2 RNA. Conclusions: vRNA was detectable at low viral loads in a minority of serum samples collected in acute infection, but was not associated with infectious SARS-CoV-2 (within the limitations of the assays used). This work helps to inform biosafety precautions for handling blood products from patients with current or previous COVID-19.
Open AccessSARS-CoV-2 RNA detected in blood samples from patients with COVID-19 is not associated with infectious virus
Background: Laboratory diagnosis of SARS-CoV-2 infection (the cause of COVID-19) uses PCR to detect viral RNA (vRNA) in respiratory samples. SARS-CoV-2 RNA has also been detected in other sample types, but there is limited understanding of the clinical or laboratory significance of its detection in blood. Methods: We undertook a systematic literature review to assimilate the evidence for the frequency of vRNA in blood, and to identify associated clinical characteristics. We performed RT-PCR in serum samples from a UK clinical cohort of acute and convalescent COVID-19 cases (n=212), together with convalescent plasma samples collected by NHS Blood and Transplant (NHSBT) (n=111 additional samples). To determine whether PCR-positive blood samples could pose an infection risk, we attempted virus isolation from a subset of RNA-positive samples. Results: We identified 28 relevant studies, reporting SARS-CoV-2 RNA in 0-76% of blood samples; pooled estimate 10% (95%CI 5-18%). Among serum samples from our clinical cohort, 27/212 (12.7%) had SARS-CoV-2 RNA detected by RT-PCR. RNA detection occurred in samples up to day 20 post symptom onset, and was associated with more severe disease (multivariable odds ratio 7.5). Across all samples collected ≥28 days post symptom onset, 0/143 (0%, 95%CI 0.0-2.5%) had vRNA detected. Among our PCR-positive samples, cycle threshold (ct) values were high (range 33.5-44.8), suggesting low vRNA copy numbers. PCR-positive sera inoculated into cell culture did not produce any cytopathic effect or yield an increase in detectable SARS-CoV-2 RNA. Conclusions: vRNA was detectable at low viral loads in a minority of serum samples collected in acute infection, but was not associated with infectious SARS-CoV-2 (within the limitations of the assays used). This work helps to inform biosafety precautions for handling blood products from patients with current or previous COVID-19.
- Open Access
Streptococcus intermedius as a leading agent of brain abscess: retrospective analysis of a UK cohort
Background: Brain abscess is an uncommon condition, but carries high mortality. Current treatment guidelines are based on limited data. Surveillance of clinical, radiological and microbiology data is important to inform patient stratification, interventions, and antimicrobial stewardship. Methods: We undertook a retrospective, observational study of patients with brain abscess, based on hospital coding, in a UK tertiary referral teaching hospital. We reviewed imaging data, laboratory microbiology, and antibiotic prescriptions. Results: Over a 47 month period, we identified 47 adults with bacterial brain abscess (77% male, median age 47 years). Most of the abscesses were solitary frontal or parietal lesions. A microbiological diagnosis was secured in 39/47 (83%) of cases, among which the majority were of the Streptococcus milleri group (27/39; 69%), with a predominance of Streptococcus intermedius (19/27; 70%). Patients received a median of 6 weeks of intravenous antibiotics (most commonly ceftriaxone), followed by variable oral follow-on regimens. Ten patients (21%) died, up to 146 days after diagnosis. Mortality was significantly associated with increasing age, multiple abscesses, immunosuppression and the presence of an underlying cardiac anomaly. Conclusion: Our data suggest that there has been a shift away from staphylococcal brain abscesses, towards S. intermedius as a dominant pathogen. In our setting, empiric current first line therapy with ceftriaxone remains appropriate on microbiological grounds and narrower spectrum therapy may sometimes be justified. Mortality of this condition remains high among patients with comorbidity. Prospective studies are required to inform optimum dose, route and duration of antimicrobial therapy.
Open AccessStreptococcus intermedius as a leading agent of brain abscess: retrospective analysis of a UK cohort
Background: Brain abscess is an uncommon condition, but carries high mortality. Current treatment guidelines are based on limited data. Surveillance of clinical, radiological and microbiology data is important to inform patient stratification, interventions, and antimicrobial stewardship. Methods: We undertook a retrospective, observational study of patients with brain abscess, based on hospital coding, in a UK tertiary referral teaching hospital. We reviewed imaging data, laboratory microbiology, and antibiotic prescriptions. Results: Over a 47 month period, we identified 47 adults with bacterial brain abscess (77% male, median age 47 years). Most of the abscesses were solitary frontal or parietal lesions. A microbiological diagnosis was secured in 39/47 (83%) of cases, among which the majority were of the Streptococcus milleri group (27/39; 69%), with a predominance of Streptococcus intermedius (19/27; 70%). Patients received a median of 6 weeks of intravenous antibiotics (most commonly ceftriaxone), followed by variable oral follow-on regimens. Ten patients (21%) died, up to 146 days after diagnosis. Mortality was significantly associated with increasing age, multiple abscesses, immunosuppression and the presence of an underlying cardiac anomaly. Conclusion: Our data suggest that there has been a shift away from staphylococcal brain abscesses, towards S. intermedius as a dominant pathogen. In our setting, empiric current first line therapy with ceftriaxone remains appropriate on microbiological grounds and narrower spectrum therapy may sometimes be justified. Mortality of this condition remains high among patients with comorbidity. Prospective studies are required to inform optimum dose, route and duration of antimicrobial therapy.
- Open Access
Trends in Escherichia coli bloodstream infection, urinary tract infections and antibiotic susceptibilities in Oxfordshire, 1998-2016: an observational study
Background: The incidence of Escherichia coli bloodstream infections (EC-BSIs), particularly those caused by antibiotic-resistant strains, is increasing in the UK and internationally. This is a major public health concern but the evidence base to guide interventions is limited. Methods: Incidence of EC-BSIs and E. coli urinary tract infections (EC-UTIs) in one UK region (Oxfordshire) were estimated from anonymised linked microbiological and hospital electronic health records, and modelled using negative binomial regression based on microbiological, clinical and healthcare exposure risk factors. Infection severity, 30-day all-cause mortality, and community and hospital co-amoxiclav use were also investigated. Findings: From 1998-2016, 5706 EC-BSIs occurred in 5215 patients, and 228376 EC-UTIs in 137075 patients. 1365(24%) EC-BSIs were nosocomial (onset >48h post-admission), 1863(33%) were community (>365 days post-discharge), 1346(24%) were quasi-community (31-365 days post-discharge), and 1132(20%) were quasi-nosocomial (<=30 days post-discharge). 1413(20%) EC-BSIs and 36270(13%) EC-UTIs were co-amoxiclav-resistant (41% and 30%, respectively, in 2016). Increases in EC-BSIs were driven by increases in community (10%/year (95% CI:7%-13%)) and quasi-community (8%/year (95% CI:7%-10%)) cases. Changes in EC-BSI-associated 30-day mortality were at most modest (p>0.03), and mortality was substantial (14-25% across groups). By contrast, co-amoxiclav-resistant EC-BSIs increased in all groups (by 11%-19%/year, significantly faster than susceptible EC-BSIs, pheterogeneity<0.001), as did co-amoxiclav-resistant EC-UTIs (by 13%-29%/year, pheterogeneity<0.001). Co-amoxiclav use in primary-care facilities was associated with subsequent co-amoxiclav-resistant EC-UTIs (p=0.03) and all EC-UTIs (p=0.002). Interpretation: Current increases in EC-BSIs in Oxfordshire are primarily community-associated, with high rates of co-amoxiclav resistance, nevertheless not impacting mortality. Interventions should target primary-care facilities with high co-amoxiclav usage. Funding: National Institute for Health Research.
Open AccessTrends in Escherichia coli bloodstream infection, urinary tract infections and antibiotic susceptibilities in Oxfordshire, 1998-2016: an observational study
Background: The incidence of Escherichia coli bloodstream infections (EC-BSIs), particularly those caused by antibiotic-resistant strains, is increasing in the UK and internationally. This is a major public health concern but the evidence base to guide interventions is limited. Methods: Incidence of EC-BSIs and E. coli urinary tract infections (EC-UTIs) in one UK region (Oxfordshire) were estimated from anonymised linked microbiological and hospital electronic health records, and modelled using negative binomial regression based on microbiological, clinical and healthcare exposure risk factors. Infection severity, 30-day all-cause mortality, and community and hospital co-amoxiclav use were also investigated. Findings: From 1998-2016, 5706 EC-BSIs occurred in 5215 patients, and 228376 EC-UTIs in 137075 patients. 1365(24%) EC-BSIs were nosocomial (onset >48h post-admission), 1863(33%) were community (>365 days post-discharge), 1346(24%) were quasi-community (31-365 days post-discharge), and 1132(20%) were quasi-nosocomial (<=30 days post-discharge). 1413(20%) EC-BSIs and 36270(13%) EC-UTIs were co-amoxiclav-resistant (41% and 30%, respectively, in 2016). Increases in EC-BSIs were driven by increases in community (10%/year (95% CI:7%-13%)) and quasi-community (8%/year (95% CI:7%-10%)) cases. Changes in EC-BSI-associated 30-day mortality were at most modest (p>0.03), and mortality was substantial (14-25% across groups). By contrast, co-amoxiclav-resistant EC-BSIs increased in all groups (by 11%-19%/year, significantly faster than susceptible EC-BSIs, pheterogeneity<0.001), as did co-amoxiclav-resistant EC-UTIs (by 13%-29%/year, pheterogeneity<0.001). Co-amoxiclav use in primary-care facilities was associated with subsequent co-amoxiclav-resistant EC-UTIs (p=0.03) and all EC-UTIs (p=0.002). Interpretation: Current increases in EC-BSIs in Oxfordshire are primarily community-associated, with high rates of co-amoxiclav resistance, nevertheless not impacting mortality. Interventions should target primary-care facilities with high co-amoxiclav usage. Funding: National Institute for Health Research.
- Open Access
Real-time analysis of nanopore-based metagenomic sequencing from orthopaedic device infection
Prosthetic joint infections are clinically difficult to diagnose and treat. Previously, we demonstrated metagenomic sequencing on an Illumina MiSeq replicates the findings of current gold standard microbiological diagnostic techniques. Nanopore sequencing offers advantages in speed of detection over MiSeq. Here, we compare direct-from-clinical-sample metagenomic Illumina sequencing with Nanopore sequencing, and report a real-time analytical pathway for Nanopore sequence data, designed for detecting bacterial composition of prosthetic joint infections. DNA was extracted from the sonication fluids of seven explanted orthopaedic devices, and additionally from two culture negative controls, and was sequenced on the Oxford Nanopore Technologies MinION platform. A specific analysis pipeline was assembled to overcome the challenges of identifying the true infecting pathogen, given high levels of host contamination and unavoidable background lab and kit contamination. The majority of DNA classified (>90%) was host contamination and discarded. Using negative control filtering thresholds, the species identified corresponded with both routine microbiological diagnosis and MiSeq results. By analysing sequences in real time, causes of infection were robustly detected within minutes from initiation of sequencing. We demonstrate initial proof of concept that metagenomic MinION sequencing can provide rapid, accurate diagnosis for prosthetic joint infections. We demonstrate a novel, scalable pipeline for real-time analysis of MinION sequence data. The high proportion of human DNA in extracts prevents full genome analysis from complete coverage, and methods to reduce this could increase genome depth and allow antimicrobial resistance profiling.
Open AccessReal-time analysis of nanopore-based metagenomic sequencing from orthopaedic device infection
Prosthetic joint infections are clinically difficult to diagnose and treat. Previously, we demonstrated metagenomic sequencing on an Illumina MiSeq replicates the findings of current gold standard microbiological diagnostic techniques. Nanopore sequencing offers advantages in speed of detection over MiSeq. Here, we compare direct-from-clinical-sample metagenomic Illumina sequencing with Nanopore sequencing, and report a real-time analytical pathway for Nanopore sequence data, designed for detecting bacterial composition of prosthetic joint infections. DNA was extracted from the sonication fluids of seven explanted orthopaedic devices, and additionally from two culture negative controls, and was sequenced on the Oxford Nanopore Technologies MinION platform. A specific analysis pipeline was assembled to overcome the challenges of identifying the true infecting pathogen, given high levels of host contamination and unavoidable background lab and kit contamination. The majority of DNA classified (>90%) was host contamination and discarded. Using negative control filtering thresholds, the species identified corresponded with both routine microbiological diagnosis and MiSeq results. By analysing sequences in real time, causes of infection were robustly detected within minutes from initiation of sequencing. We demonstrate initial proof of concept that metagenomic MinION sequencing can provide rapid, accurate diagnosis for prosthetic joint infections. We demonstrate a novel, scalable pipeline for real-time analysis of MinION sequence data. The high proportion of human DNA in extracts prevents full genome analysis from complete coverage, and methods to reduce this could increase genome depth and allow antimicrobial resistance profiling.
- Open Access
Molecular diagnosis of orthopaedic device infection direct from sonication fluid by metagenomic sequencing
Culture of multiple periprosthetic tissue samples is the current gold-standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through sonication fluid culture of explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of complete bacterial DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopaedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 samples (derivation set), we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and validated our findings in 47 independent samples. Compared to sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69(88%,95%CI 77-94%) (derivation samples 35/38[92%,79-98%]; validation 26/31[84%,66-95%]), and genus-level sensitivity was 64/69(93%,84-98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97(88%,79-93%) (derivation 43/50[86%,73-94%], validation 42/47[89%,77-96%]). High levels of human DNA contamination were seen despite use of laboratory methods to remove it. Rigorous laboratory good practice was required to prevent bacterial DNA contamination. We demonstrate metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings combined with increasing availability of portable, random-access sequencing technology offers the potential to translate metagenomic sequencing into a rapid diagnostic tool in PJI.
Open AccessMolecular diagnosis of orthopaedic device infection direct from sonication fluid by metagenomic sequencing
Culture of multiple periprosthetic tissue samples is the current gold-standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through sonication fluid culture of explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of complete bacterial DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopaedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 samples (derivation set), we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and validated our findings in 47 independent samples. Compared to sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69(88%,95%CI 77-94%) (derivation samples 35/38[92%,79-98%]; validation 26/31[84%,66-95%]), and genus-level sensitivity was 64/69(93%,84-98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97(88%,79-93%) (derivation 43/50[86%,73-94%], validation 42/47[89%,77-96%]). High levels of human DNA contamination were seen despite use of laboratory methods to remove it. Rigorous laboratory good practice was required to prevent bacterial DNA contamination. We demonstrate metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings combined with increasing availability of portable, random-access sequencing technology offers the potential to translate metagenomic sequencing into a rapid diagnostic tool in PJI.