Eric Louis
Research Subjects
Research Interests
Eric Louis has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Fred Bijkerk
Mesa institute for nanotechnology
4 shared publications- Chris J. Lee
Industrial Focus Group XUV Optics, MESA+ Institute for Nanotechnology, University of Twente, Drienerlolaan 5, 7522NB Enschede, The Netherlands
2 shared publications Herbert Wormeester
Mesa institute for nanotechnology
2 shared publications- Juequan Chen
FOM-Institute for Plasma Physics Rijnhuizen, Nieuwegein, The Netherlands
2 shared publications Robbert van de Kruijs
University of Twente 1 Industrial Focus Group XUV Optics, MESA+Institute for Nanotechnology P.O. Box 217, 7500 AE Enschede, The Netherlands
2 shared publicationsWillem van Schaik
Asml holding
2 shared publications
Latest Publications
- 14 September 2022
- Published by University Library/University of Twente
Physics and technology development of multilayer EUV reflective optics
- 14 September 2022
- Published by University Library/University of Twente
Physics and technology development of multilayer EUV reflective optics
- Open Access
- 1 January 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (1) , 77-84
Experimental study of EUV mirror radiation damage resistance under long-term free-electron laser exposures below the single-shot damage threshold
The durability of grazing- and normal-incidence optical coatings has been experimentally assessed under free-electron laser irradiation at various numbers of pulses up to 16 million shots and various fluence levels below 10% of the single-shot damage threshold. The experiment was performed at FLASH, the Free-electron LASer in Hamburg, using 13.5 nm extreme UV (EUV) radiation with 100 fs pulse duration. Polycrystalline ruthenium and amorphous carbon 50 nm thin films on silicon substrates were tested at total external reflection angles of 20° and 10° grazing incidence, respectively. Mo/Si periodical multilayer structures were tested in the Bragg reflection condition at 16° off-normal angle of incidence. The exposed areas were analysed post-mortem using differential contrast visible light microscopy, EUV reflectivity mapping and scanning X-ray photoelectron spectroscopy. The analysis revealed that Ru and Mo/Si coatings exposed to the highest dose and fluence level show a few per cent drop in their EUV reflectivity, which is explained by EUV-induced oxidation of the surface.
- 1 January 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (1) , 77-84
Open AccessExperimental study of EUV mirror radiation damage resistance under long-term free-electron laser exposures below the single-shot damage threshold
The durability of grazing- and normal-incidence optical coatings has been experimentally assessed under free-electron laser irradiation at various numbers of pulses up to 16 million shots and various fluence levels below 10% of the single-shot damage threshold. The experiment was performed at FLASH, the Free-electron LASer in Hamburg, using 13.5 nm extreme UV (EUV) radiation with 100 fs pulse duration. Polycrystalline ruthenium and amorphous carbon 50 nm thin films on silicon substrates were tested at total external reflection angles of 20° and 10° grazing incidence, respectively. Mo/Si periodical multilayer structures were tested in the Bragg reflection condition at 16° off-normal angle of incidence. The exposed areas were analysed post-mortem using differential contrast visible light microscopy, EUV reflectivity mapping and scanning X-ray photoelectron spectroscopy. The analysis revealed that Ru and Mo/Si coatings exposed to the highest dose and fluence level show a few per cent drop in their EUV reflectivity, which is explained by EUV-induced oxidation of the surface.
- Open Access
- 1 March 2017
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 4 (1)
Spectral tailoring of nanoscale EUV and soft x-ray multilayer optics
Extreme ultraviolet and soft X-ray (XUV) multilayer optics have experienced significant development over the past few years, particularly on controlling the spectral characteristics of light for advanced applications like EUV photolithography, space observation, and accelerator- or lab-based XUV experiments. Both planar and three dimensional multilayer structures have been developed to tailor the spectral response in a wide wavelength range. For the planar multilayer optics, different layered schemes are explored. Stacks of periodic multilayers and capping layers are demonstrated to achieve multi-channel reflection or suppression of the reflective properties. Aperiodic multilayer structures enable broadband reflection both in angles and wavelengths, with the possibility of polarization control. The broad wavelength band multilayer is also used to shape attosecond pulses for the study of ultrafast phenomena. Narrowband multilayer monochromators are delivered to bridge the resolution gap between crystals and regular multilayers. High spectral purity multilayers with innovated anti-reflection structures are shown to select spectrally clean XUV radiation from broadband X-ray sources, especially the plasma sources for EUV lithography. Significant progress is also made in the three dimensional multilayer optics, i.e., combining micro- and nanostructures with multilayers, in order to provide new freedom to tune the spectral response. Several kinds of multilayer gratings, including multilayer coated gratings, sliced multilayer gratings, and lamellar multilayer gratings are being pursued for high resolution and high efficiency XUV spectrometers/monochromators, with their advantages and disadvantages, respectively. Multilayer diffraction optics are also developed for spectral purity enhancement. New structures like gratings, zone plates, and pyramids that obtain full suppression of the unwanted radiation and high XUV reflectance are reviewed. Based on the present achievement of the spectral tailoring multilayer optics, the remaining challenges and opportunities for future researches are discussed.
- 1 March 2017
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 4 (1)
Open AccessSpectral tailoring of nanoscale EUV and soft x-ray multilayer optics
Extreme ultraviolet and soft X-ray (XUV) multilayer optics have experienced significant development over the past few years, particularly on controlling the spectral characteristics of light for advanced applications like EUV photolithography, space observation, and accelerator- or lab-based XUV experiments. Both planar and three dimensional multilayer structures have been developed to tailor the spectral response in a wide wavelength range. For the planar multilayer optics, different layered schemes are explored. Stacks of periodic multilayers and capping layers are demonstrated to achieve multi-channel reflection or suppression of the reflective properties. Aperiodic multilayer structures enable broadband reflection both in angles and wavelengths, with the possibility of polarization control. The broad wavelength band multilayer is also used to shape attosecond pulses for the study of ultrafast phenomena. Narrowband multilayer monochromators are delivered to bridge the resolution gap between crystals and regular multilayers. High spectral purity multilayers with innovated anti-reflection structures are shown to select spectrally clean XUV radiation from broadband X-ray sources, especially the plasma sources for EUV lithography. Significant progress is also made in the three dimensional multilayer optics, i.e., combining micro- and nanostructures with multilayers, in order to provide new freedom to tune the spectral response. Several kinds of multilayer gratings, including multilayer coated gratings, sliced multilayer gratings, and lamellar multilayer gratings are being pursued for high resolution and high efficiency XUV spectrometers/monochromators, with their advantages and disadvantages, respectively. Multilayer diffraction optics are also developed for spectral purity enhancement. New structures like gratings, zone plates, and pyramids that obtain full suppression of the unwanted radiation and high XUV reflectance are reviewed. Based on the present achievement of the spectral tailoring multilayer optics, the remaining challenges and opportunities for future researches are discussed.
- 2 September 2011
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 22 (10)
Carbon-induced extreme ultraviolet reflectance loss characterized using visible-light ellipsometry
- 2 September 2011
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 22 (10)
Carbon-induced extreme ultraviolet reflectance loss characterized using visible-light ellipsometry
- 13 March 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7271, 727140
Ellipsometric and surface acoustic wave sensing of carbon contamination on EUV optics
Carbon contamination layers, deposited on extreme ultraviolet (EUV) multilayer mirrors during illumination were characterized ex situ using spectroscopic ellipsometry (SE), laser generated surface acoustic waves (LG-SAW), and by their EUV reflectance loss. We show SE is more sensitive to the deposition of carbon layers than the EUV reflectance loss, even in the presence of the highly heterogeneous structure of the multilayer. SE has better overall sensitivity, with a detection limit of 0.2 nm, while LG-SAW has an approximate detection limit < 5 nm.
- 13 March 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7271, 727140
Ellipsometric and surface acoustic wave sensing of carbon contamination on EUV optics
Carbon contamination layers, deposited on extreme ultraviolet (EUV) multilayer mirrors during illumination were characterized ex situ using spectroscopic ellipsometry (SE), laser generated surface acoustic waves (LG-SAW), and by their EUV reflectance loss. We show SE is more sensitive to the deposition of carbon layers than the EUV reflectance loss, even in the presence of the highly heterogeneous structure of the multilayer. SE has better overall sensitivity, with a detection limit of 0.2 nm, while LG-SAW has an approximate detection limit < 5 nm.
- 5 June 1998
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3331, 400-406
Control of defects in EUV multilayers and demonstration of at-wavelength defect characterization by EUV microscopy
In EUV optical elements microscopic imperfections in multilayer coatings give rise to increased scatter and reduced integrated reflectivity. If however, the coating is in the object plane of an imaging system, the defects can be imaged. In this study, experimental work is presented on characterization of the defect density and the nature of the defects in molybdenum/silicon-multilayer coatings produced by e-beam evaporation in combination with ion-beam smoothing of the interfaces. To determine in which process steps defects are created, and how these defects can be avoided, several process parameters have been varied during single- and multilayer deposition and ion-polishing. The samples have been characterized by means of an optical particle counter and electron microscopy with energy dispersive x-ray analysis measurement capabilities. To carry out in-depth inspection of the coating, we developed a method to measure the total integrated scatter for EUV radiation from a 1 micrometers spot. Varying the photon energy around the Si- absorption edge enabled us to distinguish between surface defects and in-depth defects that cannot be seen at the multilayer surface.
- 5 June 1998
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3331, 400-406
Control of defects in EUV multilayers and demonstration of at-wavelength defect characterization by EUV microscopy
In EUV optical elements microscopic imperfections in multilayer coatings give rise to increased scatter and reduced integrated reflectivity. If however, the coating is in the object plane of an imaging system, the defects can be imaged. In this study, experimental work is presented on characterization of the defect density and the nature of the defects in molybdenum/silicon-multilayer coatings produced by e-beam evaporation in combination with ion-beam smoothing of the interfaces. To determine in which process steps defects are created, and how these defects can be avoided, several process parameters have been varied during single- and multilayer deposition and ion-polishing. The samples have been characterized by means of an optical particle counter and electron microscopy with energy dispersive x-ray analysis measurement capabilities. To carry out in-depth inspection of the coating, we developed a method to measure the total integrated scatter for EUV radiation from a 1 micrometers spot. Varying the photon energy around the Si- absorption edge enabled us to distinguish between surface defects and in-depth defects that cannot be seen at the multilayer surface.
- 20 June 1995
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2515, 194-204
Multilayer x-ray mirrors for the objective crystal spectrometer on the Spectrum Roentgen Gamma satellite
We carried out experiments to determine the optimum parameters for the production of multilayer x-ray mirrors for the lambda equals 4.4 - 7.1 nm range using electron beam evaporation and ion-polishing. We report on the deposition of Co/C and Ni/C coatings, of which we polished the metal layers with Kr+- and Ar+- ions of 300, 500, and 1000 eV. We examined the effect of different polishing parameters on the smoothening of the Co- and Ni-layers. The in-situ reflectivity of lambda equals 3.16 nm during deposition and the ex-situ grazing incidence reflectivity of Cu-K(alpha ) radiation (lambda equals 0.154 nm) were used to analyze the coatings. We found optimum performance of the mirrors when applying polishing for 40 s with 500 eV Kr+-ions at an angle of 20 degrees and an ion beam current of 20 mA. Using these parameters, we produced Co/C multilayer coatings on forty flat super-polished 6 multiplied by 6 cm2 Si (111) crystals for the Objective Crystal Spectrometer on the Russian Spectrum Rontgen Gamma satellite. The coatings on the flight crystals have a period Lambda of 3.95 plus or minus 0.02 nm and a reflectivity of more than 8% averaged over s- and p-polarization over the entire wavelength range of interest. We present a detailed analysis of the coatings on the crystals.
- 20 June 1995
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2515, 194-204
Multilayer x-ray mirrors for the objective crystal spectrometer on the Spectrum Roentgen Gamma satellite
We carried out experiments to determine the optimum parameters for the production of multilayer x-ray mirrors for the lambda equals 4.4 - 7.1 nm range using electron beam evaporation and ion-polishing. We report on the deposition of Co/C and Ni/C coatings, of which we polished the metal layers with Kr+- and Ar+- ions of 300, 500, and 1000 eV. We examined the effect of different polishing parameters on the smoothening of the Co- and Ni-layers. The in-situ reflectivity of lambda equals 3.16 nm during deposition and the ex-situ grazing incidence reflectivity of Cu-K(alpha ) radiation (lambda equals 0.154 nm) were used to analyze the coatings. We found optimum performance of the mirrors when applying polishing for 40 s with 500 eV Kr+-ions at an angle of 20 degrees and an ion beam current of 20 mA. Using these parameters, we produced Co/C multilayer coatings on forty flat super-polished 6 multiplied by 6 cm2 Si (111) crystals for the Objective Crystal Spectrometer on the Russian Spectrum Rontgen Gamma satellite. The coatings on the flight crystals have a period Lambda of 3.95 plus or minus 0.02 nm and a reflectivity of more than 8% averaged over s- and p-polarization over the entire wavelength range of interest. We present a detailed analysis of the coatings on the crystals.