TPTatiana Pikuz

Tatiana Pikuz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tatiana Pikuz has a total of 125 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of new diagnostics based on LiF detector for pump-probe experiments

    by T. Pikuz, A. Faenov, N. Ozaki, T. Matsuoka, B. Albertazzi, N.J. Hartley, K. Miyanishi, K. Katagiri, S. Matsuyama, K. Yamauchi, et al.

    We present new diagnostics for use in optical laser pump - X-ray Free Electron Laser (XFEL) probe experiments to monitor dimensions, intensity profile and focusability of the XFEL beam and to control initial quality and homogeneity of targets to be driven by optical laser pulse. By developing X-ray imaging, based on the use of an LiF crystal detector, we were able to measure the distribution of energy inside a hard X-ray beam with unprecedented high spatial resolution (∼1 μm) and across a field of view larger than some millimetres. This diagnostic can be used in situ, provides a very high dynamic range, has an extremely limited cost, and is relatively easy to be implemented in pump-probe experiments. The proposed methods were successfully applied in pump-probe experiments at the SPring-8 Angstrom Compact free electron LAser (SACLA) XFEL facility and its potential was demonstrated for current and future High Energy Density Science experiments.


  • On the size of the secondary electron cloud in crystals irradiated by hard X-ray photons

    by Alexei N. Grum-Grzhimailo, Tatiana Pikuz, Anatoly Faenov, Takeshi Matsuoka, Norimasa Ozaki, Bruno Albertazzi, Sergei Pikuz, Yuichi Inubushi, Makina Yabashi, Kensuke Tono, et al.


  • Indirect monitoring shot-to-shot shock waves strength reproducibility during pump–probe experiments

    by T. A. Pikuz, A. Ya. Faenov, N. Ozaki, N. J. Hartley, B. Albertazzi, T. Matsuoka, K. Takahashi, H. Habara, Y. Tange, S. Matsuyama, et al.

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ∼660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and to control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ∼2%, implying an accuracy in the derived electron plasma temperature of 5%–10% in pump–probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ∼ 0.5, the electron temperature follows Te ∼ Ilas2/3. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.


  • Open Access

    3D visualization of XFEL beam focusing properties using LiF crystal X-ray detector

    by Tatiana Pikuz, Anatoly Faenov, Takeshi Matsuoka, Satoshi Matsuyama, Kazuto Yamauchi, Norimasa Ozaki, Bruno Albertazzi, Yuichi Inubushi, Makina Yabashi, Kensuke Tono, et al.

    Here, we report, that by means of direct irradiation of lithium fluoride a (LiF) crystal, in situ 3D visualization of the SACLA XFEL focused beam profile along the propagation direction is realized, including propagation inside photoluminescence solid matter. High sensitivity and large dynamic range of the LiF crystal detector allowed measurements of the intensity distribution of the beam at distances far from the best focus as well as near the best focus and evaluation of XFEL source size and beam quality factor M2. Our measurements also support the theoretical prediction that for X-ray photons with energies ~10 keV the radius of the generated photoelectron cloud within the LiF crystal reaches about 600 nm before thermalization. The proposed method has a spatial resolution ~ 0.4–2.0 μm for photons with energies 6–14 keV and potentially could be used in a single shot mode for optimization of different focusing systems developed at XFEL and synchrotron facilities.


  • Low electron temperature in ablating materials formed by picosecond soft x-ray laser pulses

    by Masahiko Ishino, Noboru Hasegawa, Masaharu Nishikino, Tatiana Pikuz, Igor Skobelev, Anatoly Faenov, Nail Inogamov, Tetsuya Kawachi, Mitsuru Yamagiwa

    To study the ablation process induced by the soft x-ray laser pulse, we investigated the electron temperature of the ablating material. Focused soft x-ray laser pulses having a wavelength of 13.9 nm and duration of 7 ps were irradiated onto the LiF, Al, and Cu surfaces, and we observed the optical emission from the surfaces by use of an optical camera. On sample surfaces, we could confirm damage structures, but no emission signal in the visible spectral range during ablation could be observed. Then, we estimated the electron temperature in the ablating matter. To consider the radiation from a heated layer, we supposed a black-body radiator as an object. The calculation result was that the electron temperature was estimated to be lower than 1 eV and the process duration was shorter than 1000 ps. The theoretical model calculation suggests the spallative ablation for the interaction between the soft x-ray laser and materials. The driving force for the spallation is an increasing pressure appearing in the heated layer, and the change of the surface is considered to be due to a splash of a molten layer. The model calculation predicts that the soft x-ray laser with the fluence around the ablation threshold can create an electron temperature around 1 eV in a material. The experimental result is in good accordance with the theoretical prediction. Our investigation implies that the spallative ablation occurs in the low electron temperature region of a non-equilibrium state of warm dense matter.

  • Nano-meter scale modifications on material surfaces induced by soft x-ray laser pulse irradiations

    by Masahiko Ishino, Anatoly Faenov, Momoko Tanaka, Satoshi Tamotsu, Tatiana Pikuz, Noboru Hasegawa, Masaharu Nishikino, Nail Inogamov, Igor Skobelev, Vladimir Fortov, et al.

    To study the interactions between a soft x-ray laser (SXRL) and various materials, we irradiated Al, Au, Cu, and Si with the SXRL beam pulses having a wavelength of 13.9 nm and duration of 7 ps. Following the irradiation, the induced structures were observed using a scanning electron microscope and an atomic force microscope. With single pulse irradiation, conical structures were observed on the Al surface, and ripple-like structures were formed on the Au and Cu surfaces. The conical structures were destroyed under multiple SXRL pulse irradiation. On the other hand, the developments of modified structures were observed after multiple pulse irradiations on the Au and Cu surfaces. On the Si surface, deep holes, that seemed to be molten structures induced by the accumulation of multiple pulse irradiations, were found. Therefore, it is concluded that the SXRL pulse irradiations of various material surfaces cause different types of surface modifications, and the changes in the surface behaviors are attributed to the differences in the elemental properties of each materials, such as the melting point and the attenuation length of x-rays.


  • Phase-Contrast Imaging of Nanostructures with Incoherent Femtosecond Laser Driven Soft X-Ray Source

    by Sergei Gasilov, Tatiana Pikuz, Anatoly Faenov, Yuji Fukuda, Masaki Kando, Hideyuki Kotaki, Takayuki Homma, Keigo Kawase, Takashi Kameshima, Igor Skobelev, et al.

    Application of polychromatic (1.5–15 nm) soft X‐ray emission of a spatially large (>0.1 mm) bright femtosecond laser driven plasma source for propagation based phase contrast imaging of nanometer thick foils and biological samples is considered. Diffraction and phase contrast effects increased quality and contrast of the experimental images, registered by LiF crystal X‐ray detector with submicron resolution.

  • XUV and IR electromagnetic radiation from nonlinear laser-plasma interaction

    by Masaki Kando, Alexander S. Pirozhkov, Yuji Fukuda, Timur Zh. Esirkepov, Izuru Daito, Keigo Kawase, Jinglong Ma, Liming Chen, Yukio Hayashi, Michiaki Mori, et al.

    Electromagnetic wave generation in the extreme ultraviolet (XUV) and infrared (IR) wavelength range occurs during the interaction of intense short laser pulses with underdense plasmas. XUV pulses are generated through laser light reflection from relativistically moving electron dense shells (flying mirrors). A proof-of-principle and an advanced experiment on flying mirrors are presented. Both of the experiments demonstrated light reflection and frequency upshift to the XUV wavelength range (14-20 nm). The advanced experiment with a head-on collision of two laser pulses exhibited the high reflected photon number. IR radiation, which is observed in the forward direction, has the wavelength of 5 μm and dominantly the same polarization as the driving laser. The source of the IR radiation is attributed to emission from relativistic solitons formed in the underdense plasma.

  • Efficient light-emitting microstructures induced by EUV radiation in thermally evaporated lithium fluoride thin films

    by Rosa Maria Montereali, Salvatore Almaviva, Francesca Bonfigli, Anatoly Faenov, Francesco Flora, Ivano Franzini, Enrico Nichelatti, Tatiana Pikuz, Maria Aurora Vincenti, Giuseppe Baldacchini

    Among insulating materials containing point defects, Lithium Fluoride, LiF, is a radiation sensitive material well known in dosimetry and as active medium in optically pumped optolectronic devices. Primary and aggregate electronic defects, known as colour centres (CCs), can be efficiently produced in LiF by low-penetrating radiation. A novel imaging detector for soft X-ray microscopy, based on photoluminescence from laser active CCs, is currently under development. The continuous shrinking dimensions of photonic devices has prompted us to use thin LiF films, directly grown by thermal evaporation on different substrates, as recording media in Extreme Ultra-Violet contact-lithography experiments for the fabrication of permanent, regular, light-emitting microstructures, produced with high spatial resolution on large areas in short exposure times. The experiments were performed by using geometrical masks in an excimer-pumped laser-plasma source and the samples analyzed by confocal laser scanning microscopy. Strong visible photoluminescence at room temperature was measured from very thin surface layers. A preliminary comparison between the optical response of CCs in thin LiF films grown on glass and silicon substrates with respect to LiF crystals was performed. The polycrystalline LiF films show a higher sensitivity, which is discussed taking into account light confinement effect in the investigated planar structures.

  • SNOM characterization of micro‐radiographs stored in lithium fluoride thin films

    by A. Ustione, A. Cricenti, Francesca Bonfigli, Francesco Flora, Antonella Lai, Tiziana Marolo, Rosa Maria Montereali, Giuseppe Baldacchini, Anatoly Faenov, Tatiana Pikuz, et al.