Robert Trebski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert Trebski has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jacek Klucznik
Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
1 shared publication - Krzysztof Dobrzynski
Faculty of Electrical and Control Engineering, Gdansk University of Technology, Narutowicza 11/12, PL-80-233 Gdansk, Poland
1 shared publication - Robert Kowalak
Faculty of Electrical and Control Engineering, Gdansk University of Technology, Gdansk, Poland
1 shared publication - Stanislaw Czapp
Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland
1 shared publication - Stanislaw Pokora
Polskie Sieci Elektroenergetyczne S.A., Konstancin-Jeziorna, Poland
1 shared publication - Zbigniew Lubosny
Faculty of Electrical and Control Engineering, Gdansk University of Technology, Narutowicza 11/12, PL-80-233 Gdansk, Poland
1 shared publication
Latest Publications
- 2 May 2017
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 36 (3) , 751-763
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energy meters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical considerations based on mathematical model of the transmission line of π-type confirming that effect are presented. Power losses related to series impedance of the line and to shunt admittance are calculated. The theoretical considerations are confirmed by measurements done on the real transmission line. The calculations allow to indicate components of the active power losses, i.e. related to electromagnetic coupling among wires of a given circuit, related to electromagnetic coupling between circuits and related to shunt capacitance asymmetry. The authors indicate the influence of the line/wires geometry on the active power losses in a double-circuit overhead transmission line. Explanation of the effect of “negative” active power losses’ measurement in a double-circuit overhead transmission line is provided in this paper.
- 2 May 2017
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 36 (3) , 751-763
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energy meters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical considerations based on mathematical model of the transmission line of π-type confirming that effect are presented. Power losses related to series impedance of the line and to shunt admittance are calculated. The theoretical considerations are confirmed by measurements done on the real transmission line. The calculations allow to indicate components of the active power losses, i.e. related to electromagnetic coupling among wires of a given circuit, related to electromagnetic coupling between circuits and related to shunt capacitance asymmetry. The authors indicate the influence of the line/wires geometry on the active power losses in a double-circuit overhead transmission line. Explanation of the effect of “negative” active power losses’ measurement in a double-circuit overhead transmission line is provided in this paper.