Yuanli Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuanli Zheng has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Chun-Hui Lu
1 shared publicationChunhui Lu
Yongjia Clinic, Shanghai Stomatological Hospital, Fudan University, Shanghai, People's Republic of China
1 shared publicationJing Qiu
1 shared publicationQun Zhong
Yongjia Clinic, Shanghai Stomatological Hospital, Fudan University, Shanghai, People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 28 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0174440
Corrosion of dental alloys in artificial saliva with Streptococcus mutans
A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.
- 28 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0174440
Open AccessCorrosion of dental alloys in artificial saliva with Streptococcus mutans
A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.
- 1 April 2010
- Vol. 19 (2) , 168-72
[Study of dental alloys in the artificial saliva using an electrochemical impedance spectroscopy].
With the help of electrochemical impedance spectroscopy (EIS), the purpose of the study was to investigate the corrosion resistance of CoCr alloys ,NiCr alloys and commercially pure Ti(cp Ti) in the artificial saliva(AS). With the EIS, a test was made on the three alloys/metals in the AS (See Bode plot and Nyquist plot). And then, an analysis was made on what was known in the test by the software of ZSimpWin, after which the corrosion resistance of the alloys/metals was evaluated against the parameters of equivalent circuit [R(CR)]. In the Nyquist plot, the capacitance arc radius was in the sequence of cp Ti>CoCr>NiCr. From the Bode plot, an one time constant was able to be obtained. That was the capacitor layer. According to the equivalent circuit[R(CR)], there was no significant difference in the capacitor layer of the three alloys/metals. And the sequence of the impedance value of the three alloys/metals was cp Ti>CoCr>NiCr. The EIS results suggest that the three alloys/metals have a great corrosion resistance with cp Ti having the highest corrosion resistance and that CoCr alloys is better than NiCr alloys in the corrosion resistance. Supported by Research Fund of Science and Technology Commission of Shanghai Municipality (Grant No.08DZ2271100) and Shanghai Leading Academic Discipline Project(Grant No.T0202).
- 1 April 2010
- Vol. 19 (2) , 168-72
[Study of dental alloys in the artificial saliva using an electrochemical impedance spectroscopy].
With the help of electrochemical impedance spectroscopy (EIS), the purpose of the study was to investigate the corrosion resistance of CoCr alloys ,NiCr alloys and commercially pure Ti(cp Ti) in the artificial saliva(AS). With the EIS, a test was made on the three alloys/metals in the AS (See Bode plot and Nyquist plot). And then, an analysis was made on what was known in the test by the software of ZSimpWin, after which the corrosion resistance of the alloys/metals was evaluated against the parameters of equivalent circuit [R(CR)]. In the Nyquist plot, the capacitance arc radius was in the sequence of cp Ti>CoCr>NiCr. From the Bode plot, an one time constant was able to be obtained. That was the capacitor layer. According to the equivalent circuit[R(CR)], there was no significant difference in the capacitor layer of the three alloys/metals. And the sequence of the impedance value of the three alloys/metals was cp Ti>CoCr>NiCr. The EIS results suggest that the three alloys/metals have a great corrosion resistance with cp Ti having the highest corrosion resistance and that CoCr alloys is better than NiCr alloys in the corrosion resistance. Supported by Research Fund of Science and Technology Commission of Shanghai Municipality (Grant No.08DZ2271100) and Shanghai Leading Academic Discipline Project(Grant No.T0202).