Mathias Breithaupt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mathias Breithaupt has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aleksander Wosniok
Federal Institute for Materials Research and Testing (BAM)
1 shared publication - Andreas Kriegsmann
Federal Institute for Materials Research and Testing (BAM) Berlin Germany
1 shared publication - Christoph Strangfeld
Non-Destructive Testing, Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany
1 shared publication - Katerina Krebber
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
1 shared publication - Konstantin Hicke
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
1 shared publication - Marcus Schukar
Federal Institute for Materials Research and Testing (BAM) Berlin Germany
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by NDT.net GmbH & Co. KG
Distributed Fibre Optic Monitoring of Hydrogen Storage Composite Pressure Vessels for Automotive Use
We present our research work on the condition monitoring of hydrogen storage composite pressure vessels using distributed fibre optic sensors. The sensing fibres are integrated into the composite structure by wrapping them over the polymer liner in the helical and circumferential direction during the manufacturing process of the carbon fibre reinforced polymer. The following use of optical backscatter reflectometry allows for continuous condition monitoring and precise detection and localization of structural damages during the entire service life. To account for the time-dependent strength degradation of the composite pressure vessels, both slow burst and ambient hydraulic cycling tests, respectively, were conducted on five 70 MPa pressure vessels with integrated fibre optic sensors. The results achieved via distributed fibre optic strain sensing demonstrate a near linear strain response to pressure suitable for sensitive condition monitoring and confirm the required robustness of the selected sensor solution.
- 1 December 2025
- Published by NDT.net GmbH & Co. KG
Open AccessDistributed Fibre Optic Monitoring of Hydrogen Storage Composite Pressure Vessels for Automotive Use
We present our research work on the condition monitoring of hydrogen storage composite pressure vessels using distributed fibre optic sensors. The sensing fibres are integrated into the composite structure by wrapping them over the polymer liner in the helical and circumferential direction during the manufacturing process of the carbon fibre reinforced polymer. The following use of optical backscatter reflectometry allows for continuous condition monitoring and precise detection and localization of structural damages during the entire service life. To account for the time-dependent strength degradation of the composite pressure vessels, both slow burst and ambient hydraulic cycling tests, respectively, were conducted on five 70 MPa pressure vessels with integrated fibre optic sensors. The results achieved via distributed fibre optic strain sensing demonstrate a near linear strain response to pressure suitable for sensitive condition monitoring and confirm the required robustness of the selected sensor solution.
- Open Access
Distributed Humidity Sensing in Concrete Based on Polymer Optical Fiber
We present a preliminary investigation on distributed humidity monitoring during the drying process of concrete based on an embedded polymer optical fiber (POF). The water dissipated into the POF changes several properties of the fiber such as refractive index, scattering coefficient and attenuation factor, which eventually alters the Rayleigh backscattered light. The optical time domain reflectometer (OTDR) technique is performed to acquire the backscattered signal at the wavelengths 650 nm and 500 nm, respectively. Experimental results show that the received signal increases at 650 nm while the fiber attenuation factor clearly increases at 500 nm, as the concrete dries out. In the hygroscopic range, the information retrieved from the signal change at 650 nm agrees well with the measurement result of the electrical humidity sensors also embedded in the concrete sample.
Open AccessDistributed Humidity Sensing in Concrete Based on Polymer Optical Fiber
We present a preliminary investigation on distributed humidity monitoring during the drying process of concrete based on an embedded polymer optical fiber (POF). The water dissipated into the POF changes several properties of the fiber such as refractive index, scattering coefficient and attenuation factor, which eventually alters the Rayleigh backscattered light. The optical time domain reflectometer (OTDR) technique is performed to acquire the backscattered signal at the wavelengths 650 nm and 500 nm, respectively. Experimental results show that the received signal increases at 650 nm while the fiber attenuation factor clearly increases at 500 nm, as the concrete dries out. In the hygroscopic range, the information retrieved from the signal change at 650 nm agrees well with the measurement result of the electrical humidity sensors also embedded in the concrete sample.
- Open Access
Distributed Humidity Sensing in PMMA Optical Fibers at 500 nm and 650 nm Wavelengths
Distributed measurement of humidity is a sought-after capability for various fields of application, especially in the civil engineering and structural health monitoring sectors. This article presents a method for distributed humidity sensing along polymethyl methacrylate (PMMA) polymer optical fibers (POFs) by analyzing wavelength-dependent Rayleigh backscattering and attenuation characteristics at 500 nm and 650 nm wavelengths. Spatially resolved humidity sensing is obtained from backscatter traces of a dual-wavelength optical time domain reflectometer (OTDR). Backscatter dependence, attenuation dependence as well as the fiber length change are characterized as functions of relative humidity. Cross-sensitivity effects are discussed and quantified. The evaluation of the humidity-dependent backscatter effects at the two wavelength measurements allows for distributed and unambiguous measurement of relative humidity. The technique can be readily employed with low-cost standard polymer optical fibers and commercial OTDR devices.
Open AccessDistributed Humidity Sensing in PMMA Optical Fibers at 500 nm and 650 nm Wavelengths
Distributed measurement of humidity is a sought-after capability for various fields of application, especially in the civil engineering and structural health monitoring sectors. This article presents a method for distributed humidity sensing along polymethyl methacrylate (PMMA) polymer optical fibers (POFs) by analyzing wavelength-dependent Rayleigh backscattering and attenuation characteristics at 500 nm and 650 nm wavelengths. Spatially resolved humidity sensing is obtained from backscatter traces of a dual-wavelength optical time domain reflectometer (OTDR). Backscatter dependence, attenuation dependence as well as the fiber length change are characterized as functions of relative humidity. Cross-sensitivity effects are discussed and quantified. The evaluation of the humidity-dependent backscatter effects at the two wavelength measurements allows for distributed and unambiguous measurement of relative humidity. The technique can be readily employed with low-cost standard polymer optical fibers and commercial OTDR devices.