Colm R. Breatnach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Colm R. Breatnach has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Afif El-Khuffash
Department of Neonatology, The Rotunda Hospital, Dublin, Ireland; Department of Paediatrics, The Royal College of Surgeons in Ireland, Dublin, Ireland
6 shared publications - Damien Kenny
Our Lady's Children's Hospital Crumlin Dublin Ireland
4 shared publications Paul Oslizlok
Children Health Ireland at Crumlin Dublin Ireland
4 shared publicationsOrla Franklin
Department of Paediatric Cardiology, Children's Health Ireland at Crumlin, Dublin, Ireland
3 shared publications- Aisling Smith
Department of Neonatology, Rotunda Hospital, Dublin, Ireland
2 shared publications - Athar M. Qureshi
Texas Children’s Hospital/Baylor College of Medicine, Houston (A.M.Q.).
2 shared publications
Latest Publications
- 13 July 2026
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 36 (7) , 1418-1422
Retrospective review of baseline practices prior to implementing an enhanced recovery programme
Background: Enhanced recovery after surgery has an established evidence base in paediatric cardiac surgery, but formal programmes are infrequently implemented in Europe. Before implementing a programme, it is essential to assess current performance for benchmarking and to identify potential pitfalls. Methods: A retrospective single-centre cohort study was performed to assess the peri-operative course of a low-risk group of children undergoing congenital cardiac surgery. Patient data were collected for the entire post-operative course before discharge home or to a different centre. Data regarding respiratory and haemodynamic support, invasive devices, length of stay, and analgesia were extracted from electronic intensive care records and paper ward records. Results: The search criteria yielded 1042 operations. Following a detailed assessment of inclusion and exclusion criteria, 73 patients were included in the study. Included patients had a median age of 3.1 years and a median weight of 13 kg. Seventy-one per cent (52/73) of patients underwent early extubation within six hours. Some children without contraindications did not receive non-opioid analgesia. Most invasive devices (pacing wires, drains, and central venous catheters) were removed on the ward. The median length of stay was 1.1 days in critical care and 4.3 in hospital. Conclusions: Early extubation and duration of stay were comparable to outcomes published by some established enhanced recovery after surgery programmes, although shorter stays are achievable. Areas for improvement were identified. A centre’s specific context must be considered when implementing aspects of an enhanced recovery after surgery programme.
- 13 July 2026
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 36 (7) , 1418-1422
Retrospective review of baseline practices prior to implementing an enhanced recovery programme
Background: Enhanced recovery after surgery has an established evidence base in paediatric cardiac surgery, but formal programmes are infrequently implemented in Europe. Before implementing a programme, it is essential to assess current performance for benchmarking and to identify potential pitfalls. Methods: A retrospective single-centre cohort study was performed to assess the peri-operative course of a low-risk group of children undergoing congenital cardiac surgery. Patient data were collected for the entire post-operative course before discharge home or to a different centre. Data regarding respiratory and haemodynamic support, invasive devices, length of stay, and analgesia were extracted from electronic intensive care records and paper ward records. Results: The search criteria yielded 1042 operations. Following a detailed assessment of inclusion and exclusion criteria, 73 patients were included in the study. Included patients had a median age of 3.1 years and a median weight of 13 kg. Seventy-one per cent (52/73) of patients underwent early extubation within six hours. Some children without contraindications did not receive non-opioid analgesia. Most invasive devices (pacing wires, drains, and central venous catheters) were removed on the ward. The median length of stay was 1.1 days in critical care and 4.3 in hospital. Conclusions: Early extubation and duration of stay were comparable to outcomes published by some established enhanced recovery after surgery programmes, although shorter stays are achievable. Areas for improvement were identified. A centre’s specific context must be considered when implementing aspects of an enhanced recovery after surgery programme.
- 6 August 2024
- Published by Springer Nature
- p. 1779-1798
Pulmonary Atresia with Intact Ventricular Septum
- 6 August 2024
- Published by Springer Nature
- p. 1779-1798
Pulmonary Atresia with Intact Ventricular Septum
- 19 July 2023
- Published by Springer Nature
- p. 1-20
Pulmonary Atresia with Intact Ventricular Septum
- 29 July 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (4) , 596-605
Short‐ and medium‐term outcomes for patent ductus arteriosus stenting in neonates ≤2.5 kg with duct‐dependent pulmonary circulation
Background: Morbidity with surgical systemic‐to‐pulmonary artery shunting (SPS) in infants ≤2.5 kg has remained high. Patent ductus arteriosus (PDA) stenting may be a valid alternative. The objective of this study is to evaluate outcomes following PDA stenting in patients ≤2.5 kg from four large tertiary centers.Methods: Retrospective review of all neonates ≤2.5 kg with duct‐dependent pulmonary circulation who underwent PDA stenting. Procedural details, pulmonary arterial growth, reinterventions, surgery type, and outcomes were assessed.Results: PDA stents were implanted in 37 of 38 patients attempted (18 female) at a median procedural weight of 2.2 kg (interquartile range [IQR], 2–2.4 kg). Seven patients (18%) had a genetic abnormality and 16 (42%) had associated comorbidities. The median intensive care unit stay was 4 days (IQR, 2–6.75 days), and the median hospital stay was 20 days (IQR, 16–57.25). One patient required a rescue shunt procedure, with three others requiring early SPS (z‐score −1.16 to 0.01, p = 0.05) was greater than the left pulmonary artery (median z‐score −0.9 to −0.64, p = 0.35). Serious adverse effects (SAEs) were seen in 18% (N = 7) of our cohort. One patient developed an SAE during planned reintervention There were no intraprocedural deaths, with one early procedure‐related mortality, and three interstage mortalities not directly related to PDA stenting.Conclusions: PDA stenting in infants ≤2.5 kg is feasible and effective, promoting pulmonary artery growth. Reintervention rates are relatively high, though many are planned to allow for optimal growth before a definitive operation.
- 29 July 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (4) , 596-605
Short‐ and medium‐term outcomes for patent ductus arteriosus stenting in neonates ≤2.5 kg with duct‐dependent pulmonary circulation
Background: Morbidity with surgical systemic‐to‐pulmonary artery shunting (SPS) in infants ≤2.5 kg has remained high. Patent ductus arteriosus (PDA) stenting may be a valid alternative. The objective of this study is to evaluate outcomes following PDA stenting in patients ≤2.5 kg from four large tertiary centers.Methods: Retrospective review of all neonates ≤2.5 kg with duct‐dependent pulmonary circulation who underwent PDA stenting. Procedural details, pulmonary arterial growth, reinterventions, surgery type, and outcomes were assessed.Results: PDA stents were implanted in 37 of 38 patients attempted (18 female) at a median procedural weight of 2.2 kg (interquartile range [IQR], 2–2.4 kg). Seven patients (18%) had a genetic abnormality and 16 (42%) had associated comorbidities. The median intensive care unit stay was 4 days (IQR, 2–6.75 days), and the median hospital stay was 20 days (IQR, 16–57.25). One patient required a rescue shunt procedure, with three others requiring early SPS (z‐score −1.16 to 0.01, p = 0.05) was greater than the left pulmonary artery (median z‐score −0.9 to −0.64, p = 0.35). Serious adverse effects (SAEs) were seen in 18% (N = 7) of our cohort. One patient developed an SAE during planned reintervention There were no intraprocedural deaths, with one early procedure‐related mortality, and three interstage mortalities not directly related to PDA stenting.Conclusions: PDA stenting in infants ≤2.5 kg is feasible and effective, promoting pulmonary artery growth. Reintervention rates are relatively high, though many are planned to allow for optimal growth before a definitive operation.
- 14 February 2022
- Published by Elsevier in The Journal of Pediatrics
- Vol. 245, 172-178.e5
Relationship Between Postnatal Pulmonary Arterial Pressure and Altered Diastolic Function in Neonates with Down Syndrome
- 14 February 2022
- Published by Elsevier in The Journal of Pediatrics
- Vol. 245, 172-178.e5
Relationship Between Postnatal Pulmonary Arterial Pressure and Altered Diastolic Function in Neonates with Down Syndrome
- Open Access
- 31 August 2021
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 32 (6) , 960-968
Peri-operative myocardial performance in infants with Down syndrome undergoing CHD repair
Background: We aimed to characterise the impact of Down syndrome on myocardial performance and loading conditions in infants with Down syndrome and CHD over the peri-operative period by comparing them with infants matched for cardiac lesion with a normal microarray.Methods: Left ventricular global longitudinal strain, right ventricular free wall longitudinal strain, left ventricular end-systolic wall stress, and right ventricular systolic pressure were measured in the two groups over the peri-operative period.Results: Fifty-five infants had a diagnosis of Down syndrome and these were compared with 29 control infants. Left ventricular global longitudinal strain decreased in both groups post-operatively with the Down syndrome group demonstrating some recovery pre-discharge (18 ± 3 versus 16 ± 3 %, p = 0.01). Right ventricular longitudinal strain significantly decreased in both groups post-operatively with the control group demonstrating better recovery by hospital discharge (14 ± 4 versus 18 ± 6 %, p < 0.01). End-systolic wall stress was lower and right ventricular systolic pressure was higher in the Down syndrome group throughout the study period (all p < 0.05). Down syndrome was an independent predictor of the duration of ventilation, post-operative use of inotropes, and intensive care stay. Right ventricular longitudinal strain was an independent predictor of duration of intensive care stay.Conclusion: This study demonstrates the difference between the two groups in relation to left and right ventricular function, particularly prior to discharge, and outlines the additional impact a diagnosis of Down syndrome has on myocardial performance during the peri-operative period.
- 31 August 2021
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 32 (6) , 960-968
Open AccessPeri-operative myocardial performance in infants with Down syndrome undergoing CHD repair
Background: We aimed to characterise the impact of Down syndrome on myocardial performance and loading conditions in infants with Down syndrome and CHD over the peri-operative period by comparing them with infants matched for cardiac lesion with a normal microarray.Methods: Left ventricular global longitudinal strain, right ventricular free wall longitudinal strain, left ventricular end-systolic wall stress, and right ventricular systolic pressure were measured in the two groups over the peri-operative period.Results: Fifty-five infants had a diagnosis of Down syndrome and these were compared with 29 control infants. Left ventricular global longitudinal strain decreased in both groups post-operatively with the Down syndrome group demonstrating some recovery pre-discharge (18 ± 3 versus 16 ± 3 %, p = 0.01). Right ventricular longitudinal strain significantly decreased in both groups post-operatively with the control group demonstrating better recovery by hospital discharge (14 ± 4 versus 18 ± 6 %, p < 0.01). End-systolic wall stress was lower and right ventricular systolic pressure was higher in the Down syndrome group throughout the study period (all p < 0.05). Down syndrome was an independent predictor of the duration of ventilation, post-operative use of inotropes, and intensive care stay. Right ventricular longitudinal strain was an independent predictor of duration of intensive care stay.Conclusion: This study demonstrates the difference between the two groups in relation to left and right ventricular function, particularly prior to discharge, and outlines the additional impact a diagnosis of Down syndrome has on myocardial performance during the peri-operative period.
- 3 June 2021
- Published by Springer Nature in Pediatric Cardiology
- Vol. 42 (7) , 1539-1545
Transcarotid Approach to Ventricular Septal Defect Closure in Small Infants
Perimembranous ventricular septal defect closure in small infants has traditionally been a surgically treated defect, although alternative hybrid strategies are emerging. We aim to describe a novel approach to retrograde device closure of clinically relevant perimembranous ventricular septal defects in small infants via carotid cutdown. A retrospective review of all patients managed with attempted carotid cutdown for device closure of a perimembranous ventricular septal defect was recorded at a single tertiary cardiac centre. We summarized data on successful device deployment, conversion to open repair, complications, and length of stay. Eighteen infants with median (IQR) age of 7 months (5–9 months) and weight of 7.1 kg (6.5–7.8 kg) with clinically relevant PMVSD underwent attempted retrograde closure via carotid cutdown. Median (IQR) defect size was 8 mm (7–9 mm). Successful device deployment without significant aortic or tricuspid valve interference occurred in 15 (83%) patients. Three patients were converted to open repair, one following damage to the tricuspid valve apparatus. Median (IQR) hospital stay was 1 day (1–3 days). There were no complications related to carotid cutdown. Retrograde device closure of hemodynamically significant PMVSD is feasible and effective in small infants. Decision to convert to surgical repair should be made early if suboptimal device placement occurs. Carotid evaluation should be performed to rule out any access-related complications.
- 3 June 2021
- Published by Springer Nature in Pediatric Cardiology
- Vol. 42 (7) , 1539-1545
Transcarotid Approach to Ventricular Septal Defect Closure in Small Infants
Perimembranous ventricular septal defect closure in small infants has traditionally been a surgically treated defect, although alternative hybrid strategies are emerging. We aim to describe a novel approach to retrograde device closure of clinically relevant perimembranous ventricular septal defects in small infants via carotid cutdown. A retrospective review of all patients managed with attempted carotid cutdown for device closure of a perimembranous ventricular septal defect was recorded at a single tertiary cardiac centre. We summarized data on successful device deployment, conversion to open repair, complications, and length of stay. Eighteen infants with median (IQR) age of 7 months (5–9 months) and weight of 7.1 kg (6.5–7.8 kg) with clinically relevant PMVSD underwent attempted retrograde closure via carotid cutdown. Median (IQR) defect size was 8 mm (7–9 mm). Successful device deployment without significant aortic or tricuspid valve interference occurred in 15 (83%) patients. Three patients were converted to open repair, one following damage to the tricuspid valve apparatus. Median (IQR) hospital stay was 1 day (1–3 days). There were no complications related to carotid cutdown. Retrograde device closure of hemodynamically significant PMVSD is feasible and effective in small infants. Decision to convert to surgical repair should be made early if suboptimal device placement occurs. Carotid evaluation should be performed to rule out any access-related complications.
- 22 September 2020
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 30 (10) , 1535-1537
Cardiac strangulation causing refractory cardiac arrest during elective pacemaker revision: a cautionary tale
We describe a previously asymptomatic 7-year-old girl with a sudden cardiac arrest during elective pacemaker revision. Later imaging identified epicardial pacemaker lead strangulation of the left anterior descending and left circumflex coronary arteries. Anaesthetic induction led to a reduction in myocardial perfusion, precipitating the arrest. Extreme care should be taken during anaesthesia if cardiac strangulation is suspected.
- 22 September 2020
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 30 (10) , 1535-1537
Cardiac strangulation causing refractory cardiac arrest during elective pacemaker revision: a cautionary tale
We describe a previously asymptomatic 7-year-old girl with a sudden cardiac arrest during elective pacemaker revision. Later imaging identified epicardial pacemaker lead strangulation of the left anterior descending and left circumflex coronary arteries. Anaesthetic induction led to a reduction in myocardial perfusion, precipitating the arrest. Extreme care should be taken during anaesthesia if cardiac strangulation is suspected.
- Open Access
- 1 May 2020
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 6 (5) , 265-267
Systemic ventricular implantation of a leadless pacemaker in a patient with a univentricular heart and atrioventricular node calcification
- 1 May 2020
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 6 (5) , 265-267
Open AccessSystemic ventricular implantation of a leadless pacemaker in a patient with a univentricular heart and atrioventricular node calcification
- 19 December 2019
- Published by Springer Nature in Pediatric Cardiology
- Vol. 41 (4) , 683-686
Leadless Micra Pacemaker Use in the Pediatric Population: Device Implantation and Short-Term Outcomes
The development of Leadless cardiac pacemakers avoids the inherent complications that may occur secondary to lead insertion. A large number of devices have been inserted in adult patients although data in pediatric patients are lacking. We aimed to assess our experience with the Leadless device in the pediatric population. We performed a retrospective study on all pediatric patients who underwent insertion of a Leadless pacemaker in our center. Data were collected for demographic, procedural, and outcome variables. Nine patients with a median (IQR) age and weight of 13 (12–14) years and 37 (31–50) kg, respectively, were enrolled. The median (IQR) procedural time was 62 (60–65) min with insertion thresholds of 0.5 (0.35–1) Volts at 0.24 ms. All devices were successfully inserted without complication. One device was replaced with a single-lead endocardial pacemaker at 1 year for increased thresholds. Leadless pacemaker device insertion is feasible in pediatric patients. Further studies and long-term follow-up are needed to ascertain device longevity and complication rates.
- 19 December 2019
- Published by Springer Nature in Pediatric Cardiology
- Vol. 41 (4) , 683-686
Leadless Micra Pacemaker Use in the Pediatric Population: Device Implantation and Short-Term Outcomes
The development of Leadless cardiac pacemakers avoids the inherent complications that may occur secondary to lead insertion. A large number of devices have been inserted in adult patients although data in pediatric patients are lacking. We aimed to assess our experience with the Leadless device in the pediatric population. We performed a retrospective study on all pediatric patients who underwent insertion of a Leadless pacemaker in our center. Data were collected for demographic, procedural, and outcome variables. Nine patients with a median (IQR) age and weight of 13 (12–14) years and 37 (31–50) kg, respectively, were enrolled. The median (IQR) procedural time was 62 (60–65) min with insertion thresholds of 0.5 (0.35–1) Volts at 0.24 ms. All devices were successfully inserted without complication. One device was replaced with a single-lead endocardial pacemaker at 1 year for increased thresholds. Leadless pacemaker device insertion is feasible in pediatric patients. Further studies and long-term follow-up are needed to ascertain device longevity and complication rates.