Michał Włodarczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michał Włodarczyk has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Kamil Grabowski
Department of Microelectronics and Computer Science, Technical University of Lodz
3 shared publications - Damian Kacperski
Department of Microelectronics and Computer Science, Technical University of Lodz
2 shared publications - Wojciech Sankowski
Department of Microelectronics and Computer Science, Lodz University of Technology, Lodz, Poland
2 shared publications - Damian Kacperski
Department of Microelectornics and Computer Science, Lodz University of Technology, ul. Wolczanska 221/223, 90-924, Poland
1 shared publication - Paweł Krotewicz
Department of Microelectornics and Computer Science, Lodz University of Technology, ul. Wolczanska 221/223, 90-924, Poland
1 shared publication - Tomasz Płuciennik
Technical University of Lodz, Department of Microelectronics and Computer Science
1 shared publication
Latest Publications
- 1 January 2019
- Published by AGH University Press in Computer Science
- Vol. 20 (1) , 3-26
COMPACT: Biometric Dataset of Face Images Acquired in Uncontrolled Indoor Environment
COMPACT: Biometric Dataset of Face Images Acquired in Uncontrolled Indoor Environment
- 1 January 2019
- Published by AGH University Press in Computer Science
- Vol. 20 (1) , 3-26
COMPACT: Biometric Dataset of Face Images Acquired in Uncontrolled Indoor Environment
COMPACT: Biometric Dataset of Face Images Acquired in Uncontrolled Indoor Environment
- Open Access
- 1 January 2017
- Published by AGH University Press in Computer Science
- Vol. 18 (2) , 179-194
IMAGE ACQUISITION SYSTEM BASED ON SYNCHRONIZED HIGH-RESOLUTION GIGABIT ETHERNET CAMERAS
Image Acquisition System based on Synchronized High Resolution Gigabit Ethernet Cameras
- 1 January 2017
- Published by AGH University Press in Computer Science
- Vol. 18 (2) , 179-194
Open AccessIMAGE ACQUISITION SYSTEM BASED ON SYNCHRONIZED HIGH-RESOLUTION GIGABIT ETHERNET CAMERAS
Image Acquisition System based on Synchronized High Resolution Gigabit Ethernet Cameras
- Open Access
- 1 December 2016
- Published by Walter de Gruyter GmbH in Image Processing & Communications
- Vol. 21 (4) , 33-44
Inter-Device Periocular Recognition Under Near-Infrared Light
Periocular biometrics is a relatively new field of research, and only several publications on this topic can be found in the literature. It can become a promising feature that can be used independently or as a complement to other biometrics. In this work, the recognition rates of periocular biometrics on a single acquisition device and inter-device database is verified and the impact of different image sources on the performance of recognition algorithms is investigated. For this purpose a NearInfrared Light database was collected. The database contains images taken by two acquisition devices. In order to test the periocular biometric trait, three feature extraction methods are chosen: Histograms of Oriented Gradients, Local Binary Patterns and Scale Invariant Feature Transform. The fusion of these methods is also proposed and it is tested on inter-device database. The feasibility of applying periocular recognition as an individual decision module for a biometric system is assessed. Experimental results yield Equal Error Rate of 17.65 for right eye using inter-device database of 640 gallery periocular images for each eye side taken from 32 different individuals (20 images per individual for each eye side). These results are obtained by the optimal weighted sum fusion of the three feature extraction methods.
- 1 December 2016
- Published by Walter de Gruyter GmbH in Image Processing & Communications
- Vol. 21 (4) , 33-44
Open AccessInter-Device Periocular Recognition Under Near-Infrared Light
Periocular biometrics is a relatively new field of research, and only several publications on this topic can be found in the literature. It can become a promising feature that can be used independently or as a complement to other biometrics. In this work, the recognition rates of periocular biometrics on a single acquisition device and inter-device database is verified and the impact of different image sources on the performance of recognition algorithms is investigated. For this purpose a NearInfrared Light database was collected. The database contains images taken by two acquisition devices. In order to test the periocular biometric trait, three feature extraction methods are chosen: Histograms of Oriented Gradients, Local Binary Patterns and Scale Invariant Feature Transform. The fusion of these methods is also proposed and it is tested on inter-device database. The feasibility of applying periocular recognition as an individual decision module for a biometric system is assessed. Experimental results yield Equal Error Rate of 17.65 for right eye using inter-device database of 640 gallery periocular images for each eye side taken from 32 different individuals (20 images per individual for each eye side). These results are obtained by the optimal weighted sum fusion of the three feature extraction methods.