Du Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Du Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Qi Zhang
Oil Crops Research Institute, Chinese Academy of Agricultural Sciences
5 shared publications - Peiwu Li
Key Laboratory of Biology and Genetic Improvement of Oil Crops, Oil Crops Research Institute of the Chinese Academy of Agricultural Sciences, Ministry of Agriculture and Rural Affairs
4 shared publications - Zhaowei Zhang
School of Bioengineering and Health, Hubei Hongshan Laboratory, Wuhan Textile University, Wuhan 430020, China
4 shared publications - Wen Zhang
Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
3 shared publications - Dun Wang
Xiangyang Academy of Agricultural Sciences, Xiangyang 441057, China
2 shared publications - Hui Li
Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
2 shared publications
Latest Publications
- Open Access
Response Surface Methodology Optimization of Time-Resolved Fluorescence Immunoassay for Rapid Detection of AflatoxinB1 in Yellow Rice Wine
Yellow rice wine is susceptible to aflatoxinB1 (AFB1) contamination, yet existing detection technologies suffer from limitations such as high false-positive rates, cumbersome operational protocols, or elevated costs, rendering them inadequate for large-scale screening requirements. Consequently, the development of a highly sensitive and rapid detection method for AFB1 is urgently needed to provide technical support for quality supervision and risk assessment of yellow rice wine. In this study, AFB1 detection was performed using time-resolved fluorescence immunoassay technology, with quantitative analysis based on the ratio of the T signal value of the detection line to the C signal value of the quality control line and the natural logarithmic value of the standard solution concentration. Statistical experimental designs were used to optimize the process of this rapid detection of AFB1 in yellow rice wine. The most important factors influencing recovery rate (p < 0.05), as identified by a two-level Plackett-Burman design with 11 variables, were methanol-water volume fraction, sample to extraction solvent ratio, heating temperature, and heating time. The steepest ascent method was employed to identify the optimal regions for these four key factors. Central composite design (CCD) coupled with response surface methodology (RSM) was subsequently utilized to further explore the interactive effects among variables and determine their optimal values that maximize the recovery rate. The analysis results indicated that interactions between methanol-water volume fraction and other three factors–sample to extraction solvent ratio, heating temperature, heating time–affected the response variable (recovery rate) significantly. The predicted results showed that the maximum recovery rate of AFB1 (97.35%) could be obtained under the optimum conditions of a methanol-water volume fraction of 78%, a sample to extraction solvent ratio of 1:3.2, a heating temperature of 34 °C, and a heating time of 6.4 min. These predicted values were further verified by validation experiments. The excellent correlation between predicted and experimental values confirmed the validity and practicability of this statistical optimum strategy. Optimal conditions obtained in this experiment laid a good foundation for further use of time-resolved fluorescence immunoassay for rapid detection of AFB1 in yellow rice wine, demonstrating broad application prospects.
Open AccessResponse Surface Methodology Optimization of Time-Resolved Fluorescence Immunoassay for Rapid Detection of AflatoxinB1 in Yellow Rice Wine
Yellow rice wine is susceptible to aflatoxinB1 (AFB1) contamination, yet existing detection technologies suffer from limitations such as high false-positive rates, cumbersome operational protocols, or elevated costs, rendering them inadequate for large-scale screening requirements. Consequently, the development of a highly sensitive and rapid detection method for AFB1 is urgently needed to provide technical support for quality supervision and risk assessment of yellow rice wine. In this study, AFB1 detection was performed using time-resolved fluorescence immunoassay technology, with quantitative analysis based on the ratio of the T signal value of the detection line to the C signal value of the quality control line and the natural logarithmic value of the standard solution concentration. Statistical experimental designs were used to optimize the process of this rapid detection of AFB1 in yellow rice wine. The most important factors influencing recovery rate (p < 0.05), as identified by a two-level Plackett-Burman design with 11 variables, were methanol-water volume fraction, sample to extraction solvent ratio, heating temperature, and heating time. The steepest ascent method was employed to identify the optimal regions for these four key factors. Central composite design (CCD) coupled with response surface methodology (RSM) was subsequently utilized to further explore the interactive effects among variables and determine their optimal values that maximize the recovery rate. The analysis results indicated that interactions between methanol-water volume fraction and other three factors–sample to extraction solvent ratio, heating temperature, heating time–affected the response variable (recovery rate) significantly. The predicted results showed that the maximum recovery rate of AFB1 (97.35%) could be obtained under the optimum conditions of a methanol-water volume fraction of 78%, a sample to extraction solvent ratio of 1:3.2, a heating temperature of 34 °C, and a heating time of 6.4 min. These predicted values were further verified by validation experiments. The excellent correlation between predicted and experimental values confirmed the validity and practicability of this statistical optimum strategy. Optimal conditions obtained in this experiment laid a good foundation for further use of time-resolved fluorescence immunoassay for rapid detection of AFB1 in yellow rice wine, demonstrating broad application prospects.
- Open Access
- 23 January 2024
- Published by MDPI AG in Preprints.org
Study on Time-Resolution Fluorescence Immunochromatography of Aflatoxin B1 in Yellow Rice Wine
(1) Background: There is a risk of Aflatoxin B1(AFB1) pollution in yellow rice wine[1],threatening human life and health, the risk is a major focus of government attention and social concern.The current detection technology cannot meet the needs of large-scale testing due to the disadvantages of high false positive, cumbersome operating procedures or high cost.Therefore, it is urgent to study and establish a high-sensitivity and high-fast detection method for AFB1 to provide technical support for yellow rice wine quality supervision and risk assessment.; (2) Methods: In this study, three-factor and three-level orthogonal experiments were carried out for oscillation time, reaction temperature and tomography time to determine the best reaction conditions for pretreatment.AFB1 detection was carried out by aflatoxin time-resolved fluorescence immunochromatography technology,Through the ratio of the T signal value of the detection line to the C signal value of the quality control line and the natural logarithmic value of the standard solution concentration[2], a rapid detection technology of time-resolution fluorescence immunochromatography is established.The technology was methodically assessed, the actual yellow rice wine samples were tested, and the results were compared with the HPLC method; (3) Results: The results show that the optimal reaction conditions for pretreatment are: the sample oscillation time is 20min, the sample reaction temperature is 37°C, and the sample chromatography time is 6min. In the actual sample detection of yellow rice wine, The time-resolved fluorescence immunochromatography detection technology established in this study detects AFB1. The detection limit is 0.3 μg·kg-1,The linear range is 0.8-12.0μg·kg-1,The linear equation of the corresponding standard curve y=-0.1913x+0.5206 (R2=0.9948),The standard deviation is 0.029.The results of the in-batch accuracy and precision of this method show that the addition and recovery rate is 77.9% - 105.7%,The coefficient of variation is in 4.5% - 10.3%; Inter-batch accuracy and precision test results show that the addition recovery rate is75.9% - 85.8%,the coefficient of variation is in 8.1% - 13.9%,explain that the detection technology has good accuracy and precision.Compared with HPLC, the relative error is less than 10%,It shows that aflatoxin time-resolution fluorescence immunochromatography technology is in good agreement with the test results of national standard methods; (4) Conclusions:he rapid detection technology of time-resolution fluorescence immunochromatography of AFB1 in yellow rice wine is easy to operate with fast detection speed, high sensitivity, good repeatability and stability, and has broad application prospects.
- 23 January 2024
- Published by MDPI AG in Preprints.org
Open AccessStudy on Time-Resolution Fluorescence Immunochromatography of Aflatoxin B1 in Yellow Rice Wine
(1) Background: There is a risk of Aflatoxin B1(AFB1) pollution in yellow rice wine[1],threatening human life and health, the risk is a major focus of government attention and social concern.The current detection technology cannot meet the needs of large-scale testing due to the disadvantages of high false positive, cumbersome operating procedures or high cost.Therefore, it is urgent to study and establish a high-sensitivity and high-fast detection method for AFB1 to provide technical support for yellow rice wine quality supervision and risk assessment.; (2) Methods: In this study, three-factor and three-level orthogonal experiments were carried out for oscillation time, reaction temperature and tomography time to determine the best reaction conditions for pretreatment.AFB1 detection was carried out by aflatoxin time-resolved fluorescence immunochromatography technology,Through the ratio of the T signal value of the detection line to the C signal value of the quality control line and the natural logarithmic value of the standard solution concentration[2], a rapid detection technology of time-resolution fluorescence immunochromatography is established.The technology was methodically assessed, the actual yellow rice wine samples were tested, and the results were compared with the HPLC method; (3) Results: The results show that the optimal reaction conditions for pretreatment are: the sample oscillation time is 20min, the sample reaction temperature is 37°C, and the sample chromatography time is 6min. In the actual sample detection of yellow rice wine, The time-resolved fluorescence immunochromatography detection technology established in this study detects AFB1. The detection limit is 0.3 μg·kg-1,The linear range is 0.8-12.0μg·kg-1,The linear equation of the corresponding standard curve y=-0.1913x+0.5206 (R2=0.9948),The standard deviation is 0.029.The results of the in-batch accuracy and precision of this method show that the addition and recovery rate is 77.9% - 105.7%,The coefficient of variation is in 4.5% - 10.3%; Inter-batch accuracy and precision test results show that the addition recovery rate is75.9% - 85.8%,the coefficient of variation is in 8.1% - 13.9%,explain that the detection technology has good accuracy and precision.Compared with HPLC, the relative error is less than 10%,It shows that aflatoxin time-resolution fluorescence immunochromatography technology is in good agreement with the test results of national standard methods; (4) Conclusions:he rapid detection technology of time-resolution fluorescence immunochromatography of AFB1 in yellow rice wine is easy to operate with fast detection speed, high sensitivity, good repeatability and stability, and has broad application prospects.
- Open Access
Intelligent Electrochemical Point-of-Care Test Method with Interface Control Based on DNA Pyramids: Aflatoxin B1 Detection in Food and the Environment
Sensitive, intelligent point-of-care test (iPOCT) methods for small molecules like aflatoxin B1 (AFB1) are urgently needed for food and the environment. The challenge remains of surface control in iPOCT. Herein, we developed an electrochemical sensor based on the DNA pyramid (DNP), combining a smartphone, app, and mobile electrochemical workstations to detect AFB1. The DNP’s structure can reduce local overcrowding and entanglement between neighboring probes, control the density and orientation of recognition probes (antibodies), produce uniform and orientational surface assemblies, and improve antigen–antibody-specific recognition and binding efficiency. Simultaneously, the hollow structure of the DNP enhances the electron transfer capacity and increases the sensitivity of electrochemical detection. In this work, the biosensor based on DNP was first combined with electrochemical (Ec) iPOCT to simultaneously achieve ordered interface modulation of recognition probes and intelligent detection of AFB1. Under optimal conditions, we found a detection limit of 3 pg/mL and a linear range of 0.006–30 ng/mL (R2 = 0.995). Further, using peanut, soybean, corn, and lake water as complex matrices, it recorded recoveries of 82.15–100.53%, excellent selectivity, acceptable stability, and good reproducibility. Finally, this Ec iPOCT provides consistent results compared to the high-performance liquid chromatography-tandem mass spectrometry method.
Open AccessIntelligent Electrochemical Point-of-Care Test Method with Interface Control Based on DNA Pyramids: Aflatoxin B1 Detection in Food and the Environment
Sensitive, intelligent point-of-care test (iPOCT) methods for small molecules like aflatoxin B1 (AFB1) are urgently needed for food and the environment. The challenge remains of surface control in iPOCT. Herein, we developed an electrochemical sensor based on the DNA pyramid (DNP), combining a smartphone, app, and mobile electrochemical workstations to detect AFB1. The DNP’s structure can reduce local overcrowding and entanglement between neighboring probes, control the density and orientation of recognition probes (antibodies), produce uniform and orientational surface assemblies, and improve antigen–antibody-specific recognition and binding efficiency. Simultaneously, the hollow structure of the DNP enhances the electron transfer capacity and increases the sensitivity of electrochemical detection. In this work, the biosensor based on DNP was first combined with electrochemical (Ec) iPOCT to simultaneously achieve ordered interface modulation of recognition probes and intelligent detection of AFB1. Under optimal conditions, we found a detection limit of 3 pg/mL and a linear range of 0.006–30 ng/mL (R2 = 0.995). Further, using peanut, soybean, corn, and lake water as complex matrices, it recorded recoveries of 82.15–100.53%, excellent selectivity, acceptable stability, and good reproducibility. Finally, this Ec iPOCT provides consistent results compared to the high-performance liquid chromatography-tandem mass spectrometry method.
- Open Access
Fullerenol Quantum Dots-Based Highly Sensitive Fluorescence Aptasensor for Patulin in Apple Juice
A highly selective and sensitive aptasensor for detecting patulin (PAT) was constructed based on the fluorescence quenching of fullerenol quantum dots (FOQDs) towards carboxytetramethylrhodamine (TAMRA) through PET mechanism. The π-π stacking interaction between PAT aptamer and FOQDs closed the distance between TAMRA and FOQDs and the fluorescence of TAMRA was quenched with maximum quenching efficiency reaching 85%. There was no non-specific fluorescence quenching caused by FOQDs. In the presence of PAT, the PAT aptamer was inclined to bind with PAT and its conformation was changed. Resulting in the weak π-π stacking interaction between PAT aptamer and FOQDs. Therefore, the fluorescence of TAMRA recovered and was linearly correlated to the concentration of PAT in the range of 0.02–1 ng/mL with a detection limit of 0.01 ng/mL. This PAT aptasensor also performed well in apple juice with linear dynamic range from 0.05–1 ng/mL. The homogeneous fluorescence aptasensor shows broad application prospect in the detection of various food pollutants.
Open AccessFullerenol Quantum Dots-Based Highly Sensitive Fluorescence Aptasensor for Patulin in Apple Juice
A highly selective and sensitive aptasensor for detecting patulin (PAT) was constructed based on the fluorescence quenching of fullerenol quantum dots (FOQDs) towards carboxytetramethylrhodamine (TAMRA) through PET mechanism. The π-π stacking interaction between PAT aptamer and FOQDs closed the distance between TAMRA and FOQDs and the fluorescence of TAMRA was quenched with maximum quenching efficiency reaching 85%. There was no non-specific fluorescence quenching caused by FOQDs. In the presence of PAT, the PAT aptamer was inclined to bind with PAT and its conformation was changed. Resulting in the weak π-π stacking interaction between PAT aptamer and FOQDs. Therefore, the fluorescence of TAMRA recovered and was linearly correlated to the concentration of PAT in the range of 0.02–1 ng/mL with a detection limit of 0.01 ng/mL. This PAT aptasensor also performed well in apple juice with linear dynamic range from 0.05–1 ng/mL. The homogeneous fluorescence aptasensor shows broad application prospect in the detection of various food pollutants.
- Open Access
An On-Site Simultaneous Semi-Quantification of Aflatoxin B1, Zearalenone, and T-2 Toxin in Maize- and Cereal-Based Feed via Multicolor Immunochromatographic Assay
Multiple-mycotoxin contamination has been frequently found in the agro-food monitoring due to the coexistence of fungi. However, many determination methods focused on a single mycotoxin, highlighting the demand for on-site determination of multiple mycotoxins in a single run. We develop a multicolor-based immunochromatographic strip (ICS) for simultaneous determination of aflatoxin B1 (AFB1), zearalenone (ZEN) and T-2 toxin in maize- and cereal-based animal feeds. The nanoparticles with different colors are conjugated with three monoclonal antibodies, which serve as the immunoassay probes. The decrease in color intensity is observed by the naked eyes, providing simultaneous quantification of three mycotoxins. The visible limits of detection for AFB1, ZEN and T-2 are estimated to be 0.5, 2, and 30 ng/mL, respectively. The cut-off values are 1, 10, and 50 ng/mL, respectively. Considerable specificity and stability are found using real samples. The results are in excellent agreement with those from high-performance liquid chromatography/tandem mass spectrometry. The multi-color ICS boasts sensitive and rapid visual differentiation and simultaneous semi-quantification of aflatoxin B1, zearalenone and T-2 toxin in maize- and cereal-based feed samples within 20 min.
Open AccessAn On-Site Simultaneous Semi-Quantification of Aflatoxin B1, Zearalenone, and T-2 Toxin in Maize- and Cereal-Based Feed via Multicolor Immunochromatographic Assay
Multiple-mycotoxin contamination has been frequently found in the agro-food monitoring due to the coexistence of fungi. However, many determination methods focused on a single mycotoxin, highlighting the demand for on-site determination of multiple mycotoxins in a single run. We develop a multicolor-based immunochromatographic strip (ICS) for simultaneous determination of aflatoxin B1 (AFB1), zearalenone (ZEN) and T-2 toxin in maize- and cereal-based animal feeds. The nanoparticles with different colors are conjugated with three monoclonal antibodies, which serve as the immunoassay probes. The decrease in color intensity is observed by the naked eyes, providing simultaneous quantification of three mycotoxins. The visible limits of detection for AFB1, ZEN and T-2 are estimated to be 0.5, 2, and 30 ng/mL, respectively. The cut-off values are 1, 10, and 50 ng/mL, respectively. Considerable specificity and stability are found using real samples. The results are in excellent agreement with those from high-performance liquid chromatography/tandem mass spectrometry. The multi-color ICS boasts sensitive and rapid visual differentiation and simultaneous semi-quantification of aflatoxin B1, zearalenone and T-2 toxin in maize- and cereal-based feed samples within 20 min.
- Open Access
An On-Site, Ultra-Sensitive, Quantitative Sensing Method for the Determination of Total Aflatoxin in Peanut and Rice Based on Quantum Dot Nanobeads Strip
An on-site, ultra-sensitive, and quantitative sensing method was developed based on quantum dot nanobeads (QDNBs) and a test strip for the determination of total aflatoxins (AFTs) in rice and peanuts. The monoclonal antibody against AFT (mAbAFT) was homemade and labeled with QDNB. After the pre-coating of the AFT antigen on the test line (T line), the competitive immunoreactions were conducted between AFT and AFT antigen on the T line with QDNBs-mAbAFT. Under optimal conditions, this approach allowed a rapid response towards AFT with a considerable sensitivity of 1.4 pg/mL and 2.9 pg/mL in rice and peanut matrices, respectively. The put-in and put-out durations were within 10 min. The recoveries for AFT in rice and peanut sample matrices were recorded from 86.25% to 118.0%, with relative deviations (RSD) below 12%. The assay was further validated via the comparison between this QDNB strip and the conventional HPLC method using spiked samples. Thus, the design provided a potential alternative for on-site, ultra-sensitive, and quantitative sensing of AFT that could also be expanded to other chemical contaminants for food safety.
Open AccessAn On-Site, Ultra-Sensitive, Quantitative Sensing Method for the Determination of Total Aflatoxin in Peanut and Rice Based on Quantum Dot Nanobeads Strip
An on-site, ultra-sensitive, and quantitative sensing method was developed based on quantum dot nanobeads (QDNBs) and a test strip for the determination of total aflatoxins (AFTs) in rice and peanuts. The monoclonal antibody against AFT (mAbAFT) was homemade and labeled with QDNB. After the pre-coating of the AFT antigen on the test line (T line), the competitive immunoreactions were conducted between AFT and AFT antigen on the T line with QDNBs-mAbAFT. Under optimal conditions, this approach allowed a rapid response towards AFT with a considerable sensitivity of 1.4 pg/mL and 2.9 pg/mL in rice and peanut matrices, respectively. The put-in and put-out durations were within 10 min. The recoveries for AFT in rice and peanut sample matrices were recorded from 86.25% to 118.0%, with relative deviations (RSD) below 12%. The assay was further validated via the comparison between this QDNB strip and the conventional HPLC method using spiked samples. Thus, the design provided a potential alternative for on-site, ultra-sensitive, and quantitative sensing of AFT that could also be expanded to other chemical contaminants for food safety.