    Early neonatal mortality is modulated by gestational age, birthweight and fetal heart rate abnormalities in the low resource setting in Tanzania – a five year review 2015–2019

    by Aisa Shayo, Pendo Mlay, Emily Ahn, Hussein Kidanto, Michael Espiritu, Jeffrey Perlman

    Background: Early Neonatal mortality (ENM) (< 7 days) remains a significant problem in low resource settings. Birth asphyxia (BA), prematurity and presumed infection contribute significantly to ENM. The study objectives were to determine: first, the overall ENM rate as well as yearly ENM rate (ENMR) from 2015 to 2019; second, the influence of decreasing GA (< 37 weeks) and BW (< 2500 g) on ENM; third, the contribution of intrapartum and delivery room factors and in particular fetal heart rate abnormalities (FHRT) to ENM; and fourth, the Fresh Still Birth Rates (FSB) rates over the same time period. Methods: Retrospective cohort study undertaken in a zonal referral teaching hospital located in Northern Tanzania. Labor and delivery room data were obtained from 2015 to 2019 and included BW, GA, fetal heart rate (FHRT) abnormalities, bag mask ventilation (BMV) during resuscitation, initial temperature, and antenatal steroids use. Abnormal outcome was ENM < 7 days. Analysis included t tests, odds ratios (OR), and multivariate regression analysis. Results: The overall early neonatal mortality rate (ENMR) was 18/1000 livebirths over the 5 years and did not change significantly comparing 2015 to 2019. Comparing year 2018 to 2019, the overall ENMR decreased significantly (OR 0.62; 95% confidence interval (CI) 0.45–0.85) as well as infants ≥37 weeks (OR 0.45) (CI 0.23–0.87) and infants < 37 weeks (OR 0.57) (CI 0.39–0.84). ENMR was significantly higher for newborns < 37 versus ≥37 weeks, OR 10.5 (p < 0.0001) and BW < 2500 versus ≥2500 g OR 9.9. For infants < 1000 g / < 28 weeks, the ENMR was ~ 588/1000 livebirths. Variables associated with ENM included BW - odds of death decreased by 0.55 for every 500 g increase in weight, by 0.89 for every week increase in GA, ENMR increased 6.8-fold with BMV, 2.6-fold with abnormal FHRT, 2.2-fold with no antenatal steroids (ANS), 2.6-fold with moderate hypothermia (all < 0.0001). The overall FSB rate was 14.7/1000 births and decreased significantly in 2019 when compared to 2015 i.e., 11.3 versus 17.3/1000 live births respectively (p = 0.02). Conclusion: ENM rates were predominantly modulated by decreasing BW and GA, with smaller/ less mature newborns 10-fold more likely to die. ENM in term newborns was strongly associated with FHRT abnormalities and when coupled with respiratory depression and BMV suggests BA. In smaller newborns, lack of ACS exposure and moderate hypothermia were additional associated factors. A composite perinatal approach is essential to achieve a sustained reduction in ENMR.


  • Open Access

    Maternal health care professionals’ experiences and views on the use of obstetric ultrasound in Rwanda: A cross-sectional study

    by Ingrid Mogren, Joseph Ntaganira, Jean Paul Semasaka Sengoma, Sophia Holmlund, Rhonda Small, Lan Pham Thi, Hussein Lesio Kidanto, Matilda Ngarina, Cecilia Bergström, Kristina Edvardsson

    Background: This study, undertaken in Rwanda, aimed to investigate health professionals’ experiences and views on the following topics: current clinical guidelines for ultrasound from second trimester at the clinic, regional and national levels, and adherence to clinical guidelines; medically indicated ultrasound examinations; non-medical use of ultrasound including ultrasounds on maternal request; commercialisation of ultrasound; the value of ultrasound in relation to other clinical examinations in pregnancy; and ultrasound and medicalisation of pregnancy. Methods: A cross-sectional design was adopted. Health professionals providing antenatal care and delivery services to pregnant women in 108 health facilities were invited to complete a survey, which was developed based on the results of earlier qualitative studies undertaken as part of the CROss Country Ultrasound Study (CROCUS). Results: Nine hundred and seven health professionals participated: obstetricians/gynecologists (3.2%,) other physicians (24.5%), midwives (29.7%) and nurses (42.7%). Few physicians reported the existence of clinical guidelines at clinic, regional or national levels in Rwanda, and guidelines were moderately adhered to. Three obstetric ultrasound examinations were considered medically indicated in an uncomplicated pregnancy. Most participants (73.0%) were positive about obstetric ultrasound examinations on maternal request. Commercialisation was not considered a problem, and the majority (88.5%) agreed that ultrasound had contributed to medicalisation of pregnancy. Conclusions: Findings indicate that clinical guidelines for the use of obstetric ultrasound are limited in Rwanda. Non-medically indicated obstetric ultrasound was not considered a current problem at any level of the healthcare system. The positive attitude to obstetric ultrasound examinations on maternal request may contribute to further burden on a maternal health care system with limited resources. It is essential that limited obstetric ultrasound resources are allocated where they are most beneficial, and clearly stated medical indications would likely facilitate this.


  • Activity Recognition From Newborn Resuscitation Videos

    by Oyvind Meinich-Bache, Simon Lennart Austnes, Kjersti Engan, Ivar Austvoll, Trygve Eftestol, Helge Myklebust, Simeon Kusulla, Hussein Kidanto, Hege Ersdal

    Objective: Birth asphyxia is one of the leading causes of neonatal deaths. A key for survival is performing immediate and continuous quality newborn resuscitation. A dataset of recorded signals during newborn resuscitation, including videos, has been collected in Haydom, Tanzania, and the aim is to analyze the treatment and its effect on the newborn outcome. An important step is to generate timelines of relevant resuscitation activities, including ventilation, stimulation, suction, etc., during the resuscitation episodes. Methods: We propose a two-step deep neural network system, ORAA-net, utilizing low-quality video recordings of resuscitation episodes to do activity recognition during newborn resuscitation. The first step is to detect and track relevant objects using Convolutional Neural Networks (CNN) and post-processing, and the second step is to analyze the proposed activity regions from step 1 to do activity recognition using 3D CNNs. Results: The system recognized the activities newborn uncovered, stimulation, ventilation and suction with a mean precision of 77.67 %, a mean recall of 77,64 %, and a mean accuracy of 92.40 %. Moreover, the accuracy of the estimated number of Health Care Providers (HCPs) present during the resuscitation episodes was 68.32 %. Conclusion: The results indicate that the proposed CNN-based two-step ORAA-net could be used for object detection and activity recognition in noisy low-quality newborn resuscitation videos. Significance: A thorough analysis of the effect the different resuscitation activities have on the newborn outcome could potentially allow us to optimize treatment guidelines, training, debriefing, and local quality improvement in newborn resuscitation.


  • Open Access

    Perceptions and experiences of skilled birth attendants on using a newly developed strap-on electronic fetal heart rate monitor in Tanzania

    by Sara Rivenes Lafontan, Hussein L. Kidanto, Hege L. Ersdal, Columba K. Mbekenga, Johanne Sundby

    Regular fetal heart rate monitoring during labor can drastically reduce fresh stillbirths and neonatal mortality through early detection and management of fetal distress. Fetal monitoring in low-resource settings is often inadequate. An electronic strap-on fetal heart rate monitor called Moyo was introduced in Tanzania to improve intrapartum fetal heart rate monitoring. There is limited knowledge about how skilled birth attendants in low-resource settings perceive using new technology in routine labor care. This study aimed to explore the attitude and perceptions of skilled birth attendants using Moyo in Dar es Salaam, Tanzania. A qualitative design was used to collect data. Five focus group discussions and 10 semi-structured in-depth interviews were carried out. In total, 28 medical doctors and nurse/midwives participated in the study. The data was analyzed using qualitative content analysis. The participants in the study perceived that the device was a useful tool that made it possible to monitor several laboring women at the same time and to react faster to fetal distress alerts. It was also perceived to improve the care provided to the laboring women. Prior to the introduction of Moyo, the participants described feeling overwhelmed by the high workload, an inability to adequately monitor each laboring woman, and a fear of being blamed for negative fetal outcomes. Challenges related to use of the device included a lack of adherence to routines for use, a lack of clarity about which laboring women should be monitored continuously with the device, and misidentification of maternal heart rate as fetal heart rate. The electronic strap-on fetal heart rate monitor, Moyo, was considered to make labor monitoring easier and to reduce stress. The study findings highlight the importance of ensuring that the device’s functions, its limitations and its procedures for use are well understood by users.


  • Open Access

    Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania

    by Benjamin Kamala, Hussein Kidanto, Ingvild Dalen, Matilda Ngarina, Muzdalifat Abeid, Jeffrey Perlman, Hege Ersdal

    Background: Intrapartum foetal heart rate (FHR) monitoring is crucial for identification of hypoxic foetuses and subsequent interventions. We compared continuous monitoring using a novel nine-crystal FHR monitor (Moyo) versus intermittent single crystal Doppler (Doppler) for the detection of abnormal FHR. Methods: An unmasked randomised controlled study was conducted in a tertiary hospital in Tanzania (ClinicalTrials.gov Identifier: NCT02790554). A total of 2973 low-risk singleton pregnant women in the first stage of labour admitted with normal FHR were randomised to either Moyo (n = 1479) or Doppler (1494) arms. The primary outcome was the proportion of abnormal FHR detection. Secondary outcomes were time intervals in labour, delivery mode, Apgar scores, and perinatal outcomes. Results: Moyo detected abnormal FHR more often (13.3%) compared to Doppler (9.8%) (p = 0.002). Time intervals from admission to detection of abnormal FHR were 15% shorter in Moyo (p = 0.12) and from the detection of abnormal FHR to delivery was 36% longer in Moyo (p = 0.007) compared to the Doppler arm. Time from last FHR to delivery was 12% shorter with Moyo (p = 0.006) compared to Doppler. Caesarean section rates were higher with the Moyo device compared to Doppler (p = 0.001). Low Apgar scores (p = 0.555 and p = 0.800). Perinatal outcomes (fresh stillbirths and 24-h neonatal deaths) were comparable at delivery (p = 0.497) and 24-h post-delivery (p = 0.345). Conclusions: Abnormal FHR detection rates were higher with Moyo compared to Doppler. Moyo detected abnormal FHR earlier than Doppler, but time from detection to delivery was longer. Studies powered to detect differences in perinatal outcomes with timely responses are recommended.


  • Open Access

    Acquiring Knowledge about the Use of a Newly Developed Electronic Fetal Heart Rate Monitor: A Qualitative Study Among Birth Attendants in Tanzania

    by Sara Rivenes Lafontan, Johanne Sundby, Hussein L. Kidanto, Columba K. Mbekenga, Hege L. Ersdal

    In an effort to reduce newborn mortality, a newly developed strap-on electronic fetal heart rate monitor was introduced at several health facilities in Tanzania in 2015. Training sessions were organized to teach staff how to use the device in clinical settings. This study explores skilled birth attendants’ perceptions and experiences acquiring and transferring knowledge about the use of the monitor, also called Moyo. Knowledge about this learning process is crucial to further improve training programs and ensure correct, long-term use. Five Focus group discussions (FGDs) were carried out with doctors and nurse-midwives, who were using the monitor in the labor ward at two health facilities in Tanzania. The FGDs were analyzed using qualitative content analysis. The study revealed that the participants experienced the training about the device as useful but inadequate. Due to high turnover, a frequently mentioned challenge was that many of the birth attendants who were responsible for training others, were no longer working in the labor ward. Many participants expressed a need for refresher trainings, more practical exercises and more theory on labor management. The study highlights the need for frequent trainings sessions over time with focus on increasing overall knowledge in labor management to ensure correct use of the monitor over time.


  • Predictors of 24-h outcome in newborns in need of positive pressure ventilation at birth

    by J.E. Linde, J.M. Perlman, K. Øymar, J. Schulz, J. Eilevstjønn, M. Thallinger, S. Kusulla, H.L. Kidanto, H.L. Ersdal


  • Open Access

    Intermittent fetal heart rate monitoring using a fetoscope or hand held Doppler in rural Tanzania: a randomized controlled trial

    by Paschal Francis Mdoe, Hege L. Ersdal, Estomih R. Mduma, Jeffrey M. Perlman, Robert Moshiro, Peter T. Wangwe, Hussein Kidanto

    Neonatal mortality is a global challenge, with an estimated 1.3 million intrapartum stillbirths in 2015. The majority of these were found in low resource settings with limited options to intrapartum fetal heart monitoring devices. This trial compared frequency of abnormal fetal heart rate (FHR) detection and adverse perinatal outcomes (i.e. fresh stillbirths, 24-h neonatal deaths, admission to neonatal care unit) among women intermittently assessed by Doppler or fetoscope in a rural low-resource setting. This was an open-label randomized controlled trial conducted at Haydom Lutheran Hospital from March 2013 through August 2015. Inclusion criteria were; women in labor, singleton, cephalic presentation, normal FHR on admission (120–160 beats/minute), and cervical dilatation ≤7 cm. Verbal consent was obtained. A total of 2684 women were recruited, 1309 in the Doppler and 1375 in the fetoscope arms, respectively. Abnormal FHR was detected in 55 (4.2%) vs 42 (3.1%). (RR = 1.38; 95%CI: 0.93, 2.04) in the Doppler and fetoscope arms, respectively. Bag mask ventilation was performed in 80 (6.1%) vs 82 (6.0%). (RR = 1.03; 95%CI: 0.76, 1.38) of neonates, and adverse perinatal outcome was comparable 32(2.4%) vs 35(2.5%). (RR = 0.9; 95%CI: 0.59, 1.54), in the Doppler and fetoscope arms, respectively. This trial failed to demonstrate a statistically significant difference in the detection of abnormal FHR between intermittently used Doppler and fetoscope and adverse perinatal outcomes. However, FHR measurements were not performed as often as recommended by international guidelines. Conducting a randomized controlled study in rural settings with limited resources is associated with major challenges. This clinical trial was registered on April 2013 with registration number NCT01869582 .


  • Open Access

    Midwives’ perceptions on using a fetoscope and Doppler for fetal heart rate assessments during labor: a qualitative study in rural Tanzania

    by Paschal Francis Mdoe, Hege Langli Ersdal, Estomih Mduma, Robert Moshiro, Hussein Kidanto, Columba Mbekenga

    The Doppler is thought to be more comfortable and effective compared to the fetoscope for assessing the fetal heart rate (FHR) during labor. However, in a rural Tanzanian hospital, midwives who had easy access to both devices mostly used fetoscope. This study explored midwives’ perception of factors influencing their preference for using either a Pinard fetoscope or a FreePlay wind-up Doppler for intermittent FHR monitoring. Midwives who had worked for at least 6 months in the labor ward were recruited. Focus group discussion (FGD) was used to collect data. Five FGDs were conducted between December 2015 and February 2016. Qualitative content analysis was employed using NVivo 11.0. Three main themes emerged as factors perceived by midwives as influencing their preference; 1) Sufficient training and experience with using a device; Midwives had been using fetoscopes since their midwifery training, and they had vast experience using it. The Doppler was recently introduced in the maternity ward, and midwives had insufficient training in how to use it. 2) Ability of the device to produce reliable measurements; Using a fetoscope, one must listen for the heartbeat, count using a watch, and calculate, the Doppler provides both a display and sound of the FHR. Fetoscope measurements are prone to human errors, and Doppler measurements are prone to instrumental errors. 3) Convenience of use and comfort of a device; Fetoscopes do not need charging, and while it is possible to “personalize/hide” the measurements, and may be painful for mothers. Dopplers need charging and do not cause pain, but provide limited privacy. Midwives’ preferences of FHR monitoring devices are influenced by the level of device training, experience with using a device, reliable measurements, and convenience and comfort during use. Fetoscopes and Dopplers should be equally available during midwifery training and in clinical practice.


  • Open Access

    “I Was Relieved to Know That My Baby Was Safe”: Women’s Attitudes and Perceptions on Using a New Electronic Fetal Heart Rate Monitor during Labor in Tanzania

    by Sara Rivenes Lafontan, Johanne Sundby, Hege L. Ersdal, Muzdalifat Abeid, Hussein L. Kidanto, Columba K. Mbekenga

    To increase labor monitoring and prevent neonatal morbidity and mortality, a new wireless, strap-on electronic fetal heart rate monitor called Moyo was introduced in Tanzania in 2016. As part of the ongoing evaluation of the introduction of the monitor, the aim of this study was to explore the attitudes and perceptions of women who had worn the monitor continuously during their most recent delivery and perceptions about how it affected care. This knowledge is important to identify barriers towards adaptation in order to introduce new technology more effectively. We carried out 20 semi-structured individual interviews post-labor at two hospitals in Tanzania. A thematic content analysis was used to analyze the data. Our results indicated that the use of the monitor positively affected the women’s birth experience. It provided much-needed reassurance about the wellbeing of the child. The women considered that wearing Moyo improved care due to an increase in communication and attention from birth attendants. However, the women did not fully understand the purpose and function of the device and overestimated its capabilities. This highlights the need to improve how and when information is conveyed to women in labor.