Gary N. McAuliffe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Gary N. McAuliffe has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Arlo Upton
Department of Microbiology, Labtests, Auckland, New Zealand
5 shared publicationsLiselle Bissessor
Department of Microbiology, Labtests, Auckland, New Zealand
3 shared publicationsSally A. Roberts
Microbiology Department, LabPLUS, Auckland City Hospital, Auckland, New Zealand
3 shared publicationsSharon Moore
Department of Microbiology, Labtests, Auckland, New Zealand
3 shared publicationsSusan L. Taylor
Department of Microbiology, Middlemore Hospital, Auckland, New Zealand
3 shared publicationsEmma J. Best
Department of Paediatrics, Child and Youth Health, University of Auckland, Auckland, New Zealand
2 shared publications
Latest Publications
- 26 November 2021
- Vol. 134 (1546) , 28-37
Sensitivity and potential utility of SARS-CoV-2 rapid antigen and nucleic acid amplification tests in the context of an elimination approach
AIM: To assess the sensitivity and potential utility of five RATs and the IDNow, Liat and Oxsed nucleic acid amplification tests (NAATs) in our population. METHOD: 39 retrospective and contrived SARS-CoV-2 positive samples were tested in parallel by standard RT-PCR and RAT. A second group of 44 samples was tested by standard RT-PCR, rapid RT-PCR and two isothermal NAAT assays. Limit of detection was compared at RT-PCR cycle thresholds for all assays. RESULTS: We found that the Cobas Liat RT-PCR had 100% concordance with conventional RT-PCR, whereas the sensitivity of other rapid NAAT assays was less at lower viral loads indicated by Cts >30 (p=0.042) and the RATs at Cts >25 (p <0.001). When applied to New Zealand testing scenarios, IDNow or Oxsed NAAT could miss up to 12% and RATs up to 44.3% of COVI D-19 cases compared with the RT-PCR currently used at our laboratory. CONCLUSION: We found that the POC Cobas Liat, a platform that delivers a sample answer in 20 minutes, demonstrated equivalent performance to standard RT-PCR. However, the RATs and isothermal NAAT assays demonstrated reduced sensitivity, limiting their utility in New Zealand's currently very low prevalence setting.
- 26 November 2021
- Vol. 134 (1546) , 28-37
Sensitivity and potential utility of SARS-CoV-2 rapid antigen and nucleic acid amplification tests in the context of an elimination approach
AIM: To assess the sensitivity and potential utility of five RATs and the IDNow, Liat and Oxsed nucleic acid amplification tests (NAATs) in our population. METHOD: 39 retrospective and contrived SARS-CoV-2 positive samples were tested in parallel by standard RT-PCR and RAT. A second group of 44 samples was tested by standard RT-PCR, rapid RT-PCR and two isothermal NAAT assays. Limit of detection was compared at RT-PCR cycle thresholds for all assays. RESULTS: We found that the Cobas Liat RT-PCR had 100% concordance with conventional RT-PCR, whereas the sensitivity of other rapid NAAT assays was less at lower viral loads indicated by Cts >30 (p=0.042) and the RATs at Cts >25 (p <0.001). When applied to New Zealand testing scenarios, IDNow or Oxsed NAAT could miss up to 12% and RATs up to 44.3% of COVI D-19 cases compared with the RT-PCR currently used at our laboratory. CONCLUSION: We found that the POC Cobas Liat, a platform that delivers a sample answer in 20 minutes, demonstrated equivalent performance to standard RT-PCR. However, the RATs and isothermal NAAT assays demonstrated reduced sensitivity, limiting their utility in New Zealand's currently very low prevalence setting.
- Open Access
Comprehensive analysis of SARS-CoV-2 antibody dynamics in New Zealand
Objectives: Circulating antibodies are important markers of previous infection and immunity. Questions remain with respect to the durability and functionality of SARS-CoV-2 antibodies. This study explored antibody responses in recovered COVID-19 patients in a setting where the probability of re-exposure is effectively nil, owing to New Zealand’s successful elimination strategy. Methods: A triplex bead-based assay that detects antibody isotype (IgG, IgM and IgA) and subclass (IgG1, IgG2, IgG3, IgG4) responses against Nucleocapsid (N) protein, Receptor Binding Domain (RBD) and Spike (S) protein of SARS-CoV-2 was developed. After establishing baseline levels with pre-pandemic control sera (n=113), samples from PCR-confirmed COVID-19 patients with mild-moderate disease (n=189) collected up to eight months post-infection were examined. The relationship between antigen-specific antibodies and neutralising antibodies (NAbs) was explored with a surrogate neutralisation assay that quantifies inhibition of the RBD/hACE-2 interaction. Results: While most individuals had broad isotype and subclass responses to each antigen shortly after infection, only RBD and S protein IgG, as well as NAbs, were stable over the study period, with 99%, 96% and 90% of samples, respectively, having responses over baseline 4-8 months post-infection. Anti-RBD antibodies were strongly correlated with NAbs at all time points (Pearson’s r ≥ 0.87) and feasibility of using finger prick sampling to accurately measure anti-RBD IgG was demonstrated. Conclusion: Antibodies to SARS-CoV-2 persist for up to eight months following mild to moderate infection. This robust response can be attributed to the initial exposure without immune boosting given the lack of community transmission in our setting.
Open AccessComprehensive analysis of SARS-CoV-2 antibody dynamics in New Zealand
Objectives: Circulating antibodies are important markers of previous infection and immunity. Questions remain with respect to the durability and functionality of SARS-CoV-2 antibodies. This study explored antibody responses in recovered COVID-19 patients in a setting where the probability of re-exposure is effectively nil, owing to New Zealand’s successful elimination strategy. Methods: A triplex bead-based assay that detects antibody isotype (IgG, IgM and IgA) and subclass (IgG1, IgG2, IgG3, IgG4) responses against Nucleocapsid (N) protein, Receptor Binding Domain (RBD) and Spike (S) protein of SARS-CoV-2 was developed. After establishing baseline levels with pre-pandemic control sera (n=113), samples from PCR-confirmed COVID-19 patients with mild-moderate disease (n=189) collected up to eight months post-infection were examined. The relationship between antigen-specific antibodies and neutralising antibodies (NAbs) was explored with a surrogate neutralisation assay that quantifies inhibition of the RBD/hACE-2 interaction. Results: While most individuals had broad isotype and subclass responses to each antigen shortly after infection, only RBD and S protein IgG, as well as NAbs, were stable over the study period, with 99%, 96% and 90% of samples, respectively, having responses over baseline 4-8 months post-infection. Anti-RBD antibodies were strongly correlated with NAbs at all time points (Pearson’s r ≥ 0.87) and feasibility of using finger prick sampling to accurately measure anti-RBD IgG was demonstrated. Conclusion: Antibodies to SARS-CoV-2 persist for up to eight months following mild to moderate infection. This robust response can be attributed to the initial exposure without immune boosting given the lack of community transmission in our setting.
- 1 December 2019
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 57 (12)
Variability in Azithromycin Susceptibility Results for Neisseria gonorrhoeae Obtained Using Gradient MIC Strip and Agar Dilution Techniques
Azithromycin is a component of empirical treatment regimens for Neisseria gonorrhoeae infections, but antimicrobial susceptibility testing for this agent is technically challenging. We compared the intertest variability, MIC values, and CLSI/EUCAST categorization of clinical and reference isolates of N. gonorrhoeae treated with azithromycin by testing 107 clinical isolates and nine reference isolates by agar dilution and in duplicates using MIC test strips (Liofilchem, Italy) and Etests (bioMérieux, France).
- 1 December 2019
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 57 (12)
Variability in Azithromycin Susceptibility Results for Neisseria gonorrhoeae Obtained Using Gradient MIC Strip and Agar Dilution Techniques
Azithromycin is a component of empirical treatment regimens for Neisseria gonorrhoeae infections, but antimicrobial susceptibility testing for this agent is technically challenging. We compared the intertest variability, MIC values, and CLSI/EUCAST categorization of clinical and reference isolates of N. gonorrhoeae treated with azithromycin by testing 107 clinical isolates and nine reference isolates by agar dilution and in duplicates using MIC test strips (Liofilchem, Italy) and Etests (bioMérieux, France).
- 24 September 2019
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 30 (11) , 1116-1123
Barriers to testing and management of Mycoplasma genitalium infections in primary care
Testing and treatment for Mycoplasma genitalium (MG) infections has recently been facilitated by the increasing availability of molecular tests, but the role of testing in community-based populations is not established. Between 15 May 2017 and 22 November 2017, we tested 561 samples from 547 individuals presenting to primary care in Auckland, New Zealand, requesting investigation for sexually transmitted infections, with concurrent sterile pyuria, using the Aptima MG assay (Hologic, San Diego, CA, USA) in order to establish the prevalence of MG in this group, rates of macrolide resistance and audit primary care’s capacity to manage infections in line with international guidelines. MG was detected in 55 (10%) samples, and co-pathogens were detected in 24 (44%) MG-positive samples. Macrolide resistance mutations were detected in 22/36 (61%) samples subsequently tested using PlexPCR M. genitalium ResistancePlus (Speedx Pvt Ltd., Sydney, Australia). Empiric azithromycin treatment was given to 18 (33%) patients, and test of cure was performed in 15 (27%) patients. Our pilot study demonstrates that sterile pyuria can be a useful marker to direct testing resources in community settings, but highlights important barriers to management of MG in primary care, including clinician knowledge, high prevalence of macrolide resistance and poor completion rates for test of cure.
- 24 September 2019
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 30 (11) , 1116-1123
Barriers to testing and management of Mycoplasma genitalium infections in primary care
Testing and treatment for Mycoplasma genitalium (MG) infections has recently been facilitated by the increasing availability of molecular tests, but the role of testing in community-based populations is not established. Between 15 May 2017 and 22 November 2017, we tested 561 samples from 547 individuals presenting to primary care in Auckland, New Zealand, requesting investigation for sexually transmitted infections, with concurrent sterile pyuria, using the Aptima MG assay (Hologic, San Diego, CA, USA) in order to establish the prevalence of MG in this group, rates of macrolide resistance and audit primary care’s capacity to manage infections in line with international guidelines. MG was detected in 55 (10%) samples, and co-pathogens were detected in 24 (44%) MG-positive samples. Macrolide resistance mutations were detected in 22/36 (61%) samples subsequently tested using PlexPCR M. genitalium ResistancePlus (Speedx Pvt Ltd., Sydney, Australia). Empiric azithromycin treatment was given to 18 (33%) patients, and test of cure was performed in 15 (27%) patients. Our pilot study demonstrates that sterile pyuria can be a useful marker to direct testing resources in community settings, but highlights important barriers to management of MG in primary care, including clinician knowledge, high prevalence of macrolide resistance and poor completion rates for test of cure.
- 1 March 2019
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 93 (3) , 203-207
Suboptimal performance of rotavirus testing in a vaccinated community population should prompt laboratories to review their rotavirus testing algorithms in response to changes in disease prevalence
- 1 March 2019
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 93 (3) , 203-207
Suboptimal performance of rotavirus testing in a vaccinated community population should prompt laboratories to review their rotavirus testing algorithms in response to changes in disease prevalence
- 10 July 2018
- Published by Wiley in Internal Medicine Journal
- Vol. 48 (12) , 1487-1491
International normalised ratio monitoring in the community populations of the Auckland and Northland regions of New Zealand: time in therapeutic range and frequency of testing
Background Warfarin remains a commonly used anticoagulant for the treatment and prevention of thrombosis. To balance the risks and benefits of therapy monitoring of the International Normalised Ratio (INR) is necessary. Patients derive most benefit from warfarin when they spend ≥65% of time in the therapeutic range (INR 2‐3). Aims We performed an analysis of INR monitoring for the Auckland and Northland regions of New Zealand in order to estimate anticoagulation control and appropriateness of testing at the population level. Methods INR test results and patient demographics (age, sex) were extracted from the laboratory information system of Labtests and Northland Pathology laboratories for the period 1st Jan 2016 and 27 July 2016. Results We included 126,184 INR results from 10,922 patients. The median age of patients represented was 74 years and 57% were male. The overall mean time in therapeutic range was 63%, with a mean interval between INR tests of 14 days. Conclusions Our results indicate that anticoagulant control in our communities could be improved, and that inappropriately frequent INR testing should be redressed. Appropriate interventions could lead to net clinical benefits and reduce resource misallocation.
- 10 July 2018
- Published by Wiley in Internal Medicine Journal
- Vol. 48 (12) , 1487-1491
International normalised ratio monitoring in the community populations of the Auckland and Northland regions of New Zealand: time in therapeutic range and frequency of testing
Background Warfarin remains a commonly used anticoagulant for the treatment and prevention of thrombosis. To balance the risks and benefits of therapy monitoring of the International Normalised Ratio (INR) is necessary. Patients derive most benefit from warfarin when they spend ≥65% of time in the therapeutic range (INR 2‐3). Aims We performed an analysis of INR monitoring for the Auckland and Northland regions of New Zealand in order to estimate anticoagulation control and appropriateness of testing at the population level. Methods INR test results and patient demographics (age, sex) were extracted from the laboratory information system of Labtests and Northland Pathology laboratories for the period 1st Jan 2016 and 27 July 2016. Results We included 126,184 INR results from 10,922 patients. The median age of patients represented was 74 years and 57% were male. The overall mean time in therapeutic range was 63%, with a mean interval between INR tests of 14 days. Conclusions Our results indicate that anticoagulant control in our communities could be improved, and that inappropriately frequent INR testing should be redressed. Appropriate interventions could lead to net clinical benefits and reduce resource misallocation.