    Experimental Mechanical Testing on Signal Warning Detection (SWAD) System

    by Muhammad Syahmi Mohammad Hisyammuden, Suhaimi Hassan, Syazwan Zakaria, Musfirah Mustaffa, Mohamad Zhairul Iqumal Jumari, Mohamad Amirul Mat Nadir, Norbazlan Mohd Yusof, Mohamad Shah Ikhsan, Maznan Ismon, Hanis Zakaria, et al.

    The research study was carried out for the safety of road workers in order to avoid incidents or hazards in the direct emergency line on the highway through the implementation of a danger detection sensor device. The distance sensor detected the object or dangerous vehicle from behind at a certain distance and sent the signal output via the siren device and emergency light, which were mounted at the maintenance vehicle. In additional, the device sent signal to the receiver to alert the employee about danger situation by vibrating the vibrator motor that installed at the worker’s arm. In this study, further details on effectiveness of reliability test on the transmitter and receiver of Signal Warning Detection (SWAD) System was discussed. This experimental study was done to find the best parameter setting due to the effectiveness before the device was approved to use for highway maintenance worker. SWAD system had been succesfully developed in detecting the dangerous situation for maintenance highway worker for their safety working enviroment.

  • Open Access

    Surface temperature and delay time analysis of patched fiber reinforced polymer using infrared thermography

    by Maznan Ismon, Suhaimi Hassan, M Raffiq Rosli, Mohamad Farid Sies, Mohd Hilmi Othman, Mohd Amran Madlan

    Infrared thermograph is a non-destructive testing that is widely use in industrial and marine engineering to inspect various problems. The focus of this experiment is to analyze delay time and temperature distribution of patch fiber reinforced polymer (FRP) for painted and non-painted surfaces. An E type fiberglass was chosen as test specimen. Three units of specimen with the same 10 mm thickness were artificially induced with manufacturing defects of 20 mm, 50 mm, and 70 mm in diameter, respectively. As an active thermography approach, a hot air gun used as a radiation energy source was targeted to the specimen for a duration of 15 seconds. An infrared thermography (IR) camera of FLIR T640 was used to record the thermal contrast followed by data analysis using FLIR Tools+ software. The distance between IR camera and the specimens was fixed at 1 meter. The results showed that the patched diameter size affected a prominent thermal contrast delay time. The non-painted FRP produced shorter delay time compared to painted FRP. The painted FRP took longer period to reach thermal equilibrium. The painted FRP had higher emissivity compared to non-painted FRP. The changes in surrounding temperature and humidity may also affect the specimen thermal gradient and prominent thermal contrast delay time.

  • Open Access

    Experimental Investigation on Filtration and Cooling Effect of Kitchen Hood Ventilation System from Water-Mist Recirculation Spray: Water-Mist Spray Cycle

    by Nor Adrian Nor Salim, Norzelawati Asmuin, Azian Hariri, M. Farid Sies, Hanis Zakaria, Ahmad Fu’ad Idris, Azizi Afandi, M. Asrul Bosiran, Ishkrizat Taib, Ahmad Mubarak Tajul Arifin

    A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process and for safety purposes. The main purpose of this study is to reduce water consumption by introducing the water-mist recirculation system to replace the current method water-mist system since it is working as water loss. A standard ASTM 2519 and UL 1046 full-scaled experiment is developed in the laboratory. An existing Halton Europe/Asian water-mist operating system is adopted in this study. Twelve (12) cycles (at 24 hours of water-mist activation) have been studied to determine the maximum water-mist activation cycle. The data are collected at two (2) hours water-mist activation at every water-mist recirculation cycle. The water-mist spray fluids viscosity is 0.7 cP from fresh water until the 4th cycle (8 hours water-mist spray) and increase 14.29% (0.8 cP) at the 5th cycle to the 12th cycle. On average, the difference in gas emissions percentage for CO concentration between fresh water until the 4th cycle is 10.81 – 18.92% while the CO2 concentration is 12.33 – 18.22%. On average, the difference in cooling effects percentage for ducting temperature between fresh water until the 4th cycle is 5.55% while the hood temperature is 2.33%. From the study, the water-mist recirculation system could save up to 611,667 litres per year and 466,798.5 litres per year water for all U.S, European, and Asian kitchen hood designs per hood length. By adopting the new water-mist recirculation system to the current water-mist kitchen hood, the water operational cost for water successfully reduced to RM 4,889.63 per year and RM 6,977.86 per year for U.S design and European or Asian design per hood length respectively. The water-mist recirculation system has great potential to improve the current water-mist system for the commercial kitchen hood.

  • Open Access

    Determine spray droplets on water sensitive paper (WSP) for low pressure deflector nozzle using image J

    by M F Sies, N F Madzlan, N Asmuin, A Sadikin, H Zakaria

    In this study, determine of spray droplets size (SMD) using water sensitive paper (WSP) at low fluid pressure with deflector nozzle or tangential flow nozzle model Delavan AL75 and New Design Nozzle with two different type of swirl (ND2.5 A1.0 & ND2.5 B1.0). These three deflected flat sprays have used at different liquid mixing ratio. These liquid mixture ratios are pure water, 10% of lime juice + 90% of water (L10W90) and 30% of lime juice + 70% of water (L30W70). WSP is used to collect the spray droplets from nozzles. The operational liquid pressure of each nozzle is 3 bar, while air operational pressures are 3 bar and 6 bar. Then, the WSP were scanned using scanner then it was analyzed using ImageJ software. ImageJ can be used for determining the diameter of droplets size on the WSP. As the results from an experiment, the AL75 nozzle recorded the lowest Sauter mean diameter which is 193.69μm at 6 bar of pressurized air while ND2.5 A1.0 recorded the highest Sauter mean diameter which is 353.61µm at 3 bar of pressurized air. Summary from the experiment shows that the higher of droplet size is because of the lower air pressure (3 Bar). Then, increasing of liquid viscosity also increase the SMD. The orifice diameter for New Design nozzle (ND-2.5) is smaller than AL75, which are 2.5mm and 2.8mm respectively. The different nozzle design also gives effect the SMD. WSP is an alternative method to determine SMD for spray droplets with the low cost if compared to Phase Doppler Anemometry (PDA).


  • Analysis mist spray development with Al-75 nozzle by using high speed camera

    by M. Faqhrurrazi Bin Abd Rahman, Norzelawati Asmuin, M. Farid Sies

    Spray nozzles are used for the industries as the cleaning, cutting, and spraying. The nozzle will came so many varieties and usually can be classified according to specific mode of atomization. The present study experimentally is to investigate the spray development for the droplet size of the water in the nozzle AL-75 by using the high-speed camera. The spray development is divided into five stage and each stage consist of time from 0 milliseconds (ms) to 32 milliseconds (ms). For this experiments, the supplied pressure has been use is 1 bar, 2 bar and 3 bar for the liquid and 1 bar, 3 bar and 6 bar for the air pressure. The experiment data were obtained from the released of the mist spray nozzle in water liquid 100%, water 90% mix with lime 10% (L10W90) and water 70% mix with lime 30% (L30W70). The results shows that for the lower pressure, the time taken for the spray to become fully development is longer compared to the higher pressure.


  • Open Access

    A Study of Water-mist Recirculation System From Scale Kitchen Hood Ventilation

    by N. A. Nor Salim, Norzelawati Asmuin, M. A. Ahnaf Muslim, M. Farid Sies, A. Syakir M.Jamil, Pairan M. R.