Christian G. Kirchler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian G. Kirchler has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Christian Wolfgang Huck
University of Innsbruck Innrain 80−82
9 shared publications - Raphael Henn
Univ Innsbruck, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
5 shared publications - Florian Meischl
Institute of Analytical Chemistry and Radiochemistry, University of Innsbruck, Innsbruck, Austria
2 shared publications - Günther Karl Bonn
ADSI—Austrian Drug Screening Institute GmbH, University of Innsbruck, Mitterweg 24, 6020 Innsbruck, Austria
2 shared publications - Yukihiro Ozaki
Beijing National Laboratory for Molecular Sciences, State Key Laboratory for Rare Earth Materials Chemistry and Applications, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China
2 shared publications - Alexander Kehle
Institute of Analytical Chemistry and Radiochemistry, CCB-Center for Chemistry and Biomedicine, Innrain 80/82, 6020 Innsbruck, Austria
1 shared publication
Latest Publications
- Open Access
- 1 July 2024
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 970 (1)
Near-infrared Spectroscopy for Remote Sensing of Porosity, Density, and Cubicity of Crystalline and Amorphous H2O Ices in Astrophysical Environments
We present laboratory spectra of pure amorphous and crystalline H2O ices in the near-infrared (NIR, 1–2.5 μm/10,000–4000 cm−1) at 80–180 K. The aim of this study is to provide spectroscopic reference data that allow remotely accessing ice properties for icy objects such as icy moons, cometary ice, or Saturn rings. Specifically, we identify new spectral markers for assessing three important properties of ices in space: (i) porosity/fluffiness, (ii) bulk density of amorphous ice, and (iii) cubicity in crystalline ice. The analysis is based on the first OH-stretching overtone (2ν OH) and the combinational band at 5000 cm−1/2 μm, which are potent spectral markers for these properties. By comparison of vapor-deposited, microporous amorphous solid water, pore-free low-, high-, and very-high-density amorphous ice, we are able to separate the effect of (bulk) density from the effect of porosity on NIR-spectra of amorphous ices. This allows for clarifying a longstanding inconsistency about the density of amorphous ice vapor-deposited at low temperatures, first brought up by Jenniskens & Blake. Direct comparison of NIR spectra with powder X-ray diffractograms allows us to correlate spectral features with the number of cubic stacking layers in stacking-disordered ice Isd, ranging from fully cubic ice Ic to fully hexagonal ice Ih. We show that exposure times for instruments on the James Webb Space Telescope are in the hour range to distinguish these properties, demonstrating the usefulness of the neglected NIR spectral range for identifying ices in space.
- 1 July 2024
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 970 (1)
Open AccessNear-infrared Spectroscopy for Remote Sensing of Porosity, Density, and Cubicity of Crystalline and Amorphous H2O Ices in Astrophysical Environments
We present laboratory spectra of pure amorphous and crystalline H2O ices in the near-infrared (NIR, 1–2.5 μm/10,000–4000 cm−1) at 80–180 K. The aim of this study is to provide spectroscopic reference data that allow remotely accessing ice properties for icy objects such as icy moons, cometary ice, or Saturn rings. Specifically, we identify new spectral markers for assessing three important properties of ices in space: (i) porosity/fluffiness, (ii) bulk density of amorphous ice, and (iii) cubicity in crystalline ice. The analysis is based on the first OH-stretching overtone (2ν OH) and the combinational band at 5000 cm−1/2 μm, which are potent spectral markers for these properties. By comparison of vapor-deposited, microporous amorphous solid water, pore-free low-, high-, and very-high-density amorphous ice, we are able to separate the effect of (bulk) density from the effect of porosity on NIR-spectra of amorphous ices. This allows for clarifying a longstanding inconsistency about the density of amorphous ice vapor-deposited at low temperatures, first brought up by Jenniskens & Blake. Direct comparison of NIR spectra with powder X-ray diffractograms allows us to correlate spectral features with the number of cubic stacking layers in stacking-disordered ice Isd, ranging from fully cubic ice Ic to fully hexagonal ice Ih. We show that exposure times for instruments on the James Webb Space Telescope are in the hour range to distinguish these properties, demonstrating the usefulness of the neglected NIR spectral range for identifying ices in space.
- Open Access
Differentiation of South African Game Meat Using Near-Infrared (NIR) Spectroscopy and Hierarchical Modelling
Near-infrared (NIR) spectroscopy, combined with multivariate data analysis techniques, was used to rapidly differentiate between South African game species, irrespective of the treatment (fresh or previously frozen) or the muscle type. These individual classes (fresh; previously frozen; muscle type) were also determined per species, using hierarchical modelling. Spectra were collected with a portable handheld spectrophotometer in the 908–1676-nm range. With partial least squares discriminant analysis models, we could differentiate between the species with accuracies ranging from 89.8%–93.2%. It was also possible to distinguish between fresh and previously frozen meat (90%–100% accuracy). In addition, it was possible to distinguish between ostrich muscles (100%), as well as the forequarters and hindquarters of the zebra (90.3%) and springbok (97.9%) muscles. The results confirm NIR spectroscopy’s potential as a rapid and non-destructive method for species identification, fresh and previously frozen meat differentiation, and muscle type determination.
Open AccessDifferentiation of South African Game Meat Using Near-Infrared (NIR) Spectroscopy and Hierarchical Modelling
Near-infrared (NIR) spectroscopy, combined with multivariate data analysis techniques, was used to rapidly differentiate between South African game species, irrespective of the treatment (fresh or previously frozen) or the muscle type. These individual classes (fresh; previously frozen; muscle type) were also determined per species, using hierarchical modelling. Spectra were collected with a portable handheld spectrophotometer in the 908–1676-nm range. With partial least squares discriminant analysis models, we could differentiate between the species with accuracies ranging from 89.8%–93.2%. It was also possible to distinguish between fresh and previously frozen meat (90%–100% accuracy). In addition, it was possible to distinguish between ostrich muscles (100%), as well as the forequarters and hindquarters of the zebra (90.3%) and springbok (97.9%) muscles. The results confirm NIR spectroscopy’s potential as a rapid and non-destructive method for species identification, fresh and previously frozen meat differentiation, and muscle type determination.
- Open Access
At-Line Monitoring of the Extraction Process of Rosmarini Folium via Wet Chemical Assays, UHPLC Analysis, and Newly Developed Near-Infrared Spectroscopic Analysis Methods
The present study demonstrates the applicability of at-line monitoring of the extraction process of Rosmarinus officinalis L. leaves (Rosmarini folium) and the development of near-infrared (NIR) spectroscopic analysis methods. Therefore, whole dried Rosmarini folium samples were extracted by maceration with 70% (v/v) ethanol. For the experimental design three different specimen-taking plans were chosen. At first, monitoring was carried out using three common analytical methods: (a) total hydroxycinnamic derivatives according to the European Pharmacopoeia, (b) total phenolic content according to Folin–Ciocalteu, and (c) rosmarinic acid content measured by UHPLC-UV analysis. Precision validation of the wet chemical assays revealed a repeatability of (a) 0.12% relative standard deviation (RSD), (b) 1.1% RSD, and (c) 0.28% RSD, as well as an intermediate precision of (a) 4.1% RSD, (b) 1.3% RSD, and (c) 0.55% RSD. The collected extracts were analyzed with a NIR spectrometer using a temperature-controlled liquid attachment. Samples were measured in transmission mode with an optical path length of 1 mm. The combination of the recorded spectra and the previously obtained analytical reference values in conjunction with multivariate data analysis enabled the successful establishment of partial least squares regression (PLSR) models. Coefficients of determination (R2) were: (a) 0.94, (b) 0.96, and (c) 0.93 (obtained by test-set validation). Since Pearson correlation analysis revealed that the reference analyses correlated with each other just one of the PSLR models is required. Therefore, it is suggested that PLSR model (b) be used for monitoring the extraction process of Rosmarini folium. The application of NIR spectroscopy provides a fast and non-invasive alternative analysis method, which can subsequently be implemented for on- or in-line process control.
Open AccessAt-Line Monitoring of the Extraction Process of Rosmarini Folium via Wet Chemical Assays, UHPLC Analysis, and Newly Developed Near-Infrared Spectroscopic Analysis Methods
The present study demonstrates the applicability of at-line monitoring of the extraction process of Rosmarinus officinalis L. leaves (Rosmarini folium) and the development of near-infrared (NIR) spectroscopic analysis methods. Therefore, whole dried Rosmarini folium samples were extracted by maceration with 70% (v/v) ethanol. For the experimental design three different specimen-taking plans were chosen. At first, monitoring was carried out using three common analytical methods: (a) total hydroxycinnamic derivatives according to the European Pharmacopoeia, (b) total phenolic content according to Folin–Ciocalteu, and (c) rosmarinic acid content measured by UHPLC-UV analysis. Precision validation of the wet chemical assays revealed a repeatability of (a) 0.12% relative standard deviation (RSD), (b) 1.1% RSD, and (c) 0.28% RSD, as well as an intermediate precision of (a) 4.1% RSD, (b) 1.3% RSD, and (c) 0.55% RSD. The collected extracts were analyzed with a NIR spectrometer using a temperature-controlled liquid attachment. Samples were measured in transmission mode with an optical path length of 1 mm. The combination of the recorded spectra and the previously obtained analytical reference values in conjunction with multivariate data analysis enabled the successful establishment of partial least squares regression (PLSR) models. Coefficients of determination (R2) were: (a) 0.94, (b) 0.96, and (c) 0.93 (obtained by test-set validation). Since Pearson correlation analysis revealed that the reference analyses correlated with each other just one of the PSLR models is required. Therefore, it is suggested that PLSR model (b) be used for monitoring the extraction process of Rosmarini folium. The application of NIR spectroscopy provides a fast and non-invasive alternative analysis method, which can subsequently be implemented for on- or in-line process control.
- Open Access
Distinct Difference in Sensitivity of NIR vs. IR Bands of Melamine to Inter-Molecular Interactions with Impact on Analytical Spectroscopy Explained by Anharmonic Quantum Mechanical Study
Melamine (IUPAC: 1,3,5-Triazine-2,4,6-triamine) attracts high attention in analytical vibrational spectroscopy due to its misuse as a food adulterant. Vibrational spectroscopy [infrared (IR) and Raman and near-infrared (NIR) spectroscopy] is a major quality control tool in the detection and quantification of melamine content. The physical background for the measured spectra is not interpreted in analytical spectroscopy using chemometrics. In contrast, quantum mechanical calculations are capable of providing deep and independent insights therein. So far, the NIR region of crystalline melamine has not been studied by quantum mechanical calculations, while the investigations of its IR spectra have remained limited. In the present work, we employed fully anharmonic calculation of the NIR spectrum of melamine based on finite models, and also performed IR spectral simulation by using an infinite crystal model—periodic in three dimensions. This yielded detailed and unambiguous NIR band assignments and revised the previously known IR band assignments. We found that the out-of-plane fundamental transitions, which are essential in the IR region, are markedly more sensitive to out-of-plane inter-molecular interactions of melamine than NIR transitions. Proper description of the chemical surrounding of the molecule of melamine is more important than the anharmonicity of its vibrations. In contrast, the NIR bands mostly arise from in-plane vibrations, and remain surprisingly insensitive to the chemical environment. These findings explain previous observations that were reported in IR and NIR analytical studies of melamine.
Open AccessDistinct Difference in Sensitivity of NIR vs. IR Bands of Melamine to Inter-Molecular Interactions with Impact on Analytical Spectroscopy Explained by Anharmonic Quantum Mechanical Study
Melamine (IUPAC: 1,3,5-Triazine-2,4,6-triamine) attracts high attention in analytical vibrational spectroscopy due to its misuse as a food adulterant. Vibrational spectroscopy [infrared (IR) and Raman and near-infrared (NIR) spectroscopy] is a major quality control tool in the detection and quantification of melamine content. The physical background for the measured spectra is not interpreted in analytical spectroscopy using chemometrics. In contrast, quantum mechanical calculations are capable of providing deep and independent insights therein. So far, the NIR region of crystalline melamine has not been studied by quantum mechanical calculations, while the investigations of its IR spectra have remained limited. In the present work, we employed fully anharmonic calculation of the NIR spectrum of melamine based on finite models, and also performed IR spectral simulation by using an infinite crystal model—periodic in three dimensions. This yielded detailed and unambiguous NIR band assignments and revised the previously known IR band assignments. We found that the out-of-plane fundamental transitions, which are essential in the IR region, are markedly more sensitive to out-of-plane inter-molecular interactions of melamine than NIR transitions. Proper description of the chemical surrounding of the molecule of melamine is more important than the anharmonicity of its vibrations. In contrast, the NIR bands mostly arise from in-plane vibrations, and remain surprisingly insensitive to the chemical environment. These findings explain previous observations that were reported in IR and NIR analytical studies of melamine.
- 1 December 2018
- Published by Elsevier in Food Control
- Vol. 94, 331-340
Near infrared spectroscopy as an alternative quick method for simultaneous detection of multiple adulterants in whey protein-based sports supplement
- 1 December 2018
- Published by Elsevier in Food Control
- Vol. 94, 331-340
Near infrared spectroscopy as an alternative quick method for simultaneous detection of multiple adulterants in whey protein-based sports supplement
- Open Access
Direct Determination of Ni2+-Capacity of IMAC Materials Using Near-Infrared Spectroscopy
The present paper reports a new method for the quantification of the Ni2+-capacity of an immobilized metal affinity chromatography (IMAC) material using near-infrared spectroscopy (NIRS). Conventional analyses using UV absorption spectroscopy or atomic absorption spectrometry (AAS) need to dissolve the silica-based metal chelate sorbent as sample pretreatment. In the first step, those methods were validated on the basis of an ideal homogenous NiSO4-solution and unveiled that UV with an intermediate precision of 2.6% relative standard deviation (RSD) had an advantage over AAS with an intermediate precision of 6.5% RSD. Therefore, UV analysis was chosen as reference method for the newly established NIRS model which has the advantage of being able to measure the material directly in diffuse reflection mode. Partial least squares regression (PLSR) analysis was used as multivariate data analysis tool for quantification. The best PLSR result obtained was: coefficient of determination (R2) = 0.88, factor = 2, root mean square error of prediction (RMSEP) = 22 µmol/g (test-set validation) or 7.5% RSDPLSR. Validation of the Ni2+-capacity using UV absorption spectroscopy resulted in an intermediate precision of ±18 µmol/g or 5.0% RSD. Therefore, NIRS provides a fast alternative analysis method without the need of sample preparation.
Open AccessDirect Determination of Ni2+-Capacity of IMAC Materials Using Near-Infrared Spectroscopy
The present paper reports a new method for the quantification of the Ni2+-capacity of an immobilized metal affinity chromatography (IMAC) material using near-infrared spectroscopy (NIRS). Conventional analyses using UV absorption spectroscopy or atomic absorption spectrometry (AAS) need to dissolve the silica-based metal chelate sorbent as sample pretreatment. In the first step, those methods were validated on the basis of an ideal homogenous NiSO4-solution and unveiled that UV with an intermediate precision of 2.6% relative standard deviation (RSD) had an advantage over AAS with an intermediate precision of 6.5% RSD. Therefore, UV analysis was chosen as reference method for the newly established NIRS model which has the advantage of being able to measure the material directly in diffuse reflection mode. Partial least squares regression (PLSR) analysis was used as multivariate data analysis tool for quantification. The best PLSR result obtained was: coefficient of determination (R2) = 0.88, factor = 2, root mean square error of prediction (RMSEP) = 22 µmol/g (test-set validation) or 7.5% RSDPLSR. Validation of the Ni2+-capacity using UV absorption spectroscopy resulted in an intermediate precision of ±18 µmol/g or 5.0% RSD. Therefore, NIRS provides a fast alternative analysis method without the need of sample preparation.
- Open Access
- 26 February 2018
- Published by Wiley in Journal of Biophotonics
- Vol. 11 (7) , e201700365
Hemodialysis monitoring using mid‐ and near‐infrared spectroscopy with partial least squares regression
Blood constituents such as urea, glucose, lactate, phosphate and creatinine are of high relevance in monitoring the process of detoxification in ambulant dialysis treatment. In the present work, 2 different vibrational spectroscopic techniques are used to determine those molecules quantitatively in artificial dialysate solutions. The goal of the study is to compare the performance of near‐infrared (NIR) and mid‐infrared (MIR) spectroscopy in hyphenation with partial least squares regression (PLSR) directly by using the same sample set. The results show that MIR spectroscopy is better suited to analyze the analytes of interest. Multilevel multifactor design is used to cover the relevant concentration variations during dialysis. MIR spectroscopy coupled to a multi reflection attenuated total reflection (ATR) cell enables reliable prediction of all target analytes. In contrast, the NIR spectroscopic method does not give access to all 5 components but only to urea and glucose. For both methods, coefficients of determination greater or equal to 0.86 can be achieved in the test‐set validation process for urea and glucose. Lactate, phosphate and creatinine perform well in the MIR with R2 ≥ 0.95 using test‐set validation.
- 26 February 2018
- Published by Wiley in Journal of Biophotonics
- Vol. 11 (7) , e201700365
Open AccessHemodialysis monitoring using mid‐ and near‐infrared spectroscopy with partial least squares regression
Blood constituents such as urea, glucose, lactate, phosphate and creatinine are of high relevance in monitoring the process of detoxification in ambulant dialysis treatment. In the present work, 2 different vibrational spectroscopic techniques are used to determine those molecules quantitatively in artificial dialysate solutions. The goal of the study is to compare the performance of near‐infrared (NIR) and mid‐infrared (MIR) spectroscopy in hyphenation with partial least squares regression (PLSR) directly by using the same sample set. The results show that MIR spectroscopy is better suited to analyze the analytes of interest. Multilevel multifactor design is used to cover the relevant concentration variations during dialysis. MIR spectroscopy coupled to a multi reflection attenuated total reflection (ATR) cell enables reliable prediction of all target analytes. In contrast, the NIR spectroscopic method does not give access to all 5 components but only to urea and glucose. For both methods, coefficients of determination greater or equal to 0.86 can be achieved in the test‐set validation process for urea and glucose. Lactate, phosphate and creatinine perform well in the MIR with R2 ≥ 0.95 using test‐set validation.