Diganta Dutta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diganta Dutta has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xavier-Lewis Palmer
Old Dominion University
6 shared publications - Lanju Mei
Department of Engineering and Aviation Sciences, University of Maryland Eastern Shore, Princess Anne, MD 21853, USA
3 shared publications - Jung Yul Lim
Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588, USA
2 shared publications - Matthew Ziemke
Department of Physics, Astronomy, and Engineering, University of Nebraska at Kearney, Kearney, NE 68849, USA
2 shared publications Michael Stacey
Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, 23529, USA
2 shared publicationsShizhi Qian
Institute of Micro and Nano technology, Old Dominion University, Norfolk, VA, 23529, USA
2 shared publications
Latest Publications
- Open Access
Buffer pH-Driven Electrokinetic Concentration of Proteins in a Straight Microfluidic Channel
We present a buffer-pH-modulated electrokinetic concentration strategy in MEMS microchannels that harnesses simple pH shifts to neutralize and charge proteins, reversibly “pausing” them at a planar electric-gate electrode by tuning to their isoelectric point (pI) and mobilizing them with slight pH offsets under an applied field. This synergistic coupling of dynamic pH control and electrode-gated focusing, which requires only buffer composition changes, enables rapid and tunable protein capture and release across diverse channel geometries for lab-on-chip, preparative, and point-of-care diagnostics. Moreover, it dovetails with established MEMS biomedical platforms ranging from diagnostics to drug delivery and microsurgery to gene and cell-manipulation devices. Future work on tailored electrode coatings and optimized channel profiles will further boost selectivity, speed, and integration in sub-100 µm MEMS devices.
Open AccessBuffer pH-Driven Electrokinetic Concentration of Proteins in a Straight Microfluidic Channel
We present a buffer-pH-modulated electrokinetic concentration strategy in MEMS microchannels that harnesses simple pH shifts to neutralize and charge proteins, reversibly “pausing” them at a planar electric-gate electrode by tuning to their isoelectric point (pI) and mobilizing them with slight pH offsets under an applied field. This synergistic coupling of dynamic pH control and electrode-gated focusing, which requires only buffer composition changes, enables rapid and tunable protein capture and release across diverse channel geometries for lab-on-chip, preparative, and point-of-care diagnostics. Moreover, it dovetails with established MEMS biomedical platforms ranging from diagnostics to drug delivery and microsurgery to gene and cell-manipulation devices. Future work on tailored electrode coatings and optimized channel profiles will further boost selectivity, speed, and integration in sub-100 µm MEMS devices.
- Open Access
- 30 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7369
Energy-Efficient AC Electrothermal Microfluidic Pumping via Localized External Heating
In this study, we present a comprehensive numerical investigation of alternating-current electrothermal (ACET) pumping strategies tailored for energy-efficient microfluidic applications. Using coupled electrokinetic and thermal multiphysics simulations in narrow microchannels, we systematically explore the effects of channel geometry, electrode asymmetry and external heating on flow performance and thermal management. A rigorous mesh convergence study confirms velocity deviations below ±0.006 µm/s across the entire operating envelope, ensuring reliable prediction of ACET-driven flows. We demonstrate that increasing channel height from 100 µm to 500 µm reduces peak temperatures by up to 79 K at a constant 2 W heat input, highlighting the critical role of channel dimensions in convective heat dissipation. Introducing a localized external heat source beneath asymmetric electrode pairs enhances convective circulations, while doubling the fluid’s electrical conductivity yields a ~29% increase in net flow rate. From these results, we derive practical design guidelines—combining asymmetric electrode layouts, tailored channel heights, and external heat bias—to realize self-regulating, low-power microfluidic pumps. Such devices hold significant promises for on-chip semiconductor cooling, lab-on-a-chip assays and real-time thermal control in high-performance microelectronic and analytical systems.
- 30 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (13) , 7369
Open AccessEnergy-Efficient AC Electrothermal Microfluidic Pumping via Localized External Heating
In this study, we present a comprehensive numerical investigation of alternating-current electrothermal (ACET) pumping strategies tailored for energy-efficient microfluidic applications. Using coupled electrokinetic and thermal multiphysics simulations in narrow microchannels, we systematically explore the effects of channel geometry, electrode asymmetry and external heating on flow performance and thermal management. A rigorous mesh convergence study confirms velocity deviations below ±0.006 µm/s across the entire operating envelope, ensuring reliable prediction of ACET-driven flows. We demonstrate that increasing channel height from 100 µm to 500 µm reduces peak temperatures by up to 79 K at a constant 2 W heat input, highlighting the critical role of channel dimensions in convective heat dissipation. Introducing a localized external heat source beneath asymmetric electrode pairs enhances convective circulations, while doubling the fluid’s electrical conductivity yields a ~29% increase in net flow rate. From these results, we derive practical design guidelines—combining asymmetric electrode layouts, tailored channel heights, and external heat bias—to realize self-regulating, low-power microfluidic pumps. Such devices hold significant promises for on-chip semiconductor cooling, lab-on-a-chip assays and real-time thermal control in high-performance microelectronic and analytical systems.
- Open Access
Cytoarchitecture of Breast Cancer Cells under Diabetic Conditions: Role of Regulatory Kinases—Rho Kinase and Focal Adhesion Kinase
Diabetes greatly reduces the survival rates in breast cancer patients due to chemoresistance and metastasis. Reorganization of the cytoskeleton is crucial to cell migration and metastasis. Regulatory cytoskeletal protein kinases such as the Rho kinase (ROCK) and focal adhesion kinase (FAK) play a key role in cell mobility and have been shown to be affected in cancer. It is hypothesized that diabetes/high-glucose conditions alter the cytoskeletal structure and, thus, the elasticity of breast cancer cells through the ROCK and FAK pathway, which can cause rapid metastasis of cancer. The aim of the study was to investigate the role of potential mediators that affect the morphology of cancer cells in diabetes, thus leading to aggressive cancer. Breast cancer cells (MDA-MB-231 and MCF-7) were treated with 5 mM glucose (low glucose) or 25 mM glucose (high glucose) in the presence of Rho kinase inhibitor (Y-27632, 10 mM) or FAK inhibitor (10 mM). Cell morphology and elasticity were monitored using atomic force microscopy (AFM), and actin staining was performed by fluorescence microscopy. For comparative study, normal mammary breast epithelial cells (MCF-10A) were used. It was observed that high-glucose treatments modified the cytoskeleton of the cells, as observed through AFM and fluorescence microscopy, and significantly reduced the elasticity of the cells. Blocking the ROCK or FAK pathway diminished the high-glucose effects. These changes were more evident in the breast cancer cells as compared to the normal cells. This study improves the knowledge on the cytoarchitecture properties of diabetic breast cancer cells and provides potential pathways that can be targeted to prevent such effects.
Open AccessCytoarchitecture of Breast Cancer Cells under Diabetic Conditions: Role of Regulatory Kinases—Rho Kinase and Focal Adhesion Kinase
Diabetes greatly reduces the survival rates in breast cancer patients due to chemoresistance and metastasis. Reorganization of the cytoskeleton is crucial to cell migration and metastasis. Regulatory cytoskeletal protein kinases such as the Rho kinase (ROCK) and focal adhesion kinase (FAK) play a key role in cell mobility and have been shown to be affected in cancer. It is hypothesized that diabetes/high-glucose conditions alter the cytoskeletal structure and, thus, the elasticity of breast cancer cells through the ROCK and FAK pathway, which can cause rapid metastasis of cancer. The aim of the study was to investigate the role of potential mediators that affect the morphology of cancer cells in diabetes, thus leading to aggressive cancer. Breast cancer cells (MDA-MB-231 and MCF-7) were treated with 5 mM glucose (low glucose) or 25 mM glucose (high glucose) in the presence of Rho kinase inhibitor (Y-27632, 10 mM) or FAK inhibitor (10 mM). Cell morphology and elasticity were monitored using atomic force microscopy (AFM), and actin staining was performed by fluorescence microscopy. For comparative study, normal mammary breast epithelial cells (MCF-10A) were used. It was observed that high-glucose treatments modified the cytoskeleton of the cells, as observed through AFM and fluorescence microscopy, and significantly reduced the elasticity of the cells. Blocking the ROCK or FAK pathway diminished the high-glucose effects. These changes were more evident in the breast cancer cells as compared to the normal cells. This study improves the knowledge on the cytoarchitecture properties of diabetic breast cancer cells and provides potential pathways that can be targeted to prevent such effects.
- Open Access
Simulation on the Separation of Breast Cancer Cells within a Dual-Patterned End Microfluidic Device
Microfluidic devices have long been useful for both the modeling and diagnostics of numerous diseases. In the past 20 years, they have been increasingly adopted for helping to study those in the family of breast cancer through characterizing breast cancer cells and advancing treatment research in portable and replicable formats. This paper adds to the body of work concerning cancer-focused microfluidics by proposing a simulation of a hypothetical bi-ended three-pronged device with a single channel and 16 electrodes with 8 pairs under different voltage and frequency regimes using COMSOL. Further, a study was conducted to examine the frequencies most effective for ACEO to separate cancer cells and accompanying particles. The study revealed that the frequency of EF has a more significant impact on the separation of particles than the inlet velocity. Inlet velocity variations while holding the frequency of EF constant resulted in a consistent trend showing a direct proportionality between inlet velocity and net velocity. These findings suggest that optimizing the frequency of EF could lead to more effective particle separation and targeted therapeutic interventions for breast cancer. This study hopefully will help to create targeted therapeutic interventions by bridging the disparity between in vitro and in vivo models.
Open AccessSimulation on the Separation of Breast Cancer Cells within a Dual-Patterned End Microfluidic Device
Microfluidic devices have long been useful for both the modeling and diagnostics of numerous diseases. In the past 20 years, they have been increasingly adopted for helping to study those in the family of breast cancer through characterizing breast cancer cells and advancing treatment research in portable and replicable formats. This paper adds to the body of work concerning cancer-focused microfluidics by proposing a simulation of a hypothetical bi-ended three-pronged device with a single channel and 16 electrodes with 8 pairs under different voltage and frequency regimes using COMSOL. Further, a study was conducted to examine the frequencies most effective for ACEO to separate cancer cells and accompanying particles. The study revealed that the frequency of EF has a more significant impact on the separation of particles than the inlet velocity. Inlet velocity variations while holding the frequency of EF constant resulted in a consistent trend showing a direct proportionality between inlet velocity and net velocity. These findings suggest that optimizing the frequency of EF could lead to more effective particle separation and targeted therapeutic interventions for breast cancer. This study hopefully will help to create targeted therapeutic interventions by bridging the disparity between in vitro and in vivo models.
- Open Access
Long-Range ACEO Phenomena in Microfluidic Channel
Microfluidic devices are increasingly utilized in numerous industries, including that of medicine, for their abilities to pump and mix fluid at a microscale. Within these devices, microchannels paired with microelectrodes enable the mixing and transportation of ionized fluid. The ionization process charges the microchannel and manipulates the fluid with an electric field. Although complex in operation at the microscale, microchannels within microfluidic devices are easy to produce and economical. This paper uses simulations to convey helpful insights into the analysis of electrokinetic microfluidic device phenomena. The simulations in this paper use the Navier–Stokes and Poisson Nernst–Planck equations solved using COMSOL to determine the maximum attainable fluid velocity with an electric potential applied to the microchannel and the most suitable frequency or voltage to use for transporting the fluid. Alternating current electroosmosis (ACEO) directs and provides velocity to the ionized fluid. ACEO can also mix the fluid at low frequencies for the purpose of dispersing particles. DC electroosmosis (DCEO) applies voltage along the microchannel to create an electric field that ionizes fluid within the microchannel, making it a cost-effective method for transporting fluid. This paper explores a method for an alternate efficient utilization of microfluidic devices for efficient mixing and transportation of ionized fluid and analyzes the electrokinetic phenomena through simulations using the Navier–Stokes and Poisson Nernst–Planck equations. The results provide insights into the parameters at play for transporting the fluid using alternating current electroosmosis (ACEO) and DC electroosmosis (DCEO).
Open AccessLong-Range ACEO Phenomena in Microfluidic Channel
Microfluidic devices are increasingly utilized in numerous industries, including that of medicine, for their abilities to pump and mix fluid at a microscale. Within these devices, microchannels paired with microelectrodes enable the mixing and transportation of ionized fluid. The ionization process charges the microchannel and manipulates the fluid with an electric field. Although complex in operation at the microscale, microchannels within microfluidic devices are easy to produce and economical. This paper uses simulations to convey helpful insights into the analysis of electrokinetic microfluidic device phenomena. The simulations in this paper use the Navier–Stokes and Poisson Nernst–Planck equations solved using COMSOL to determine the maximum attainable fluid velocity with an electric potential applied to the microchannel and the most suitable frequency or voltage to use for transporting the fluid. Alternating current electroosmosis (ACEO) directs and provides velocity to the ionized fluid. ACEO can also mix the fluid at low frequencies for the purpose of dispersing particles. DC electroosmosis (DCEO) applies voltage along the microchannel to create an electric field that ionizes fluid within the microchannel, making it a cost-effective method for transporting fluid. This paper explores a method for an alternate efficient utilization of microfluidic devices for efficient mixing and transportation of ionized fluid and analyzes the electrokinetic phenomena through simulations using the Navier–Stokes and Poisson Nernst–Planck equations. The results provide insights into the parameters at play for transporting the fluid using alternating current electroosmosis (ACEO) and DC electroosmosis (DCEO).
- Open Access
- 14 April 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (4) , 431
Electroosmotic Mixing of Non-Newtonian Fluid in a Microchannel with Obstacles and Zeta Potential Heterogeneity
This paper investigates the electroosmotic micromixing of non-Newtonian fluid in a microchannel with wall-mounted obstacles and surface potential heterogeneity on the obstacle surface. In the numerical simulation, the full model consisting of the Navier–Stokes equations and the Poisson–Nernst–Plank equations are solved for the electroosmotic fluid field, ion transport, and electric field, and the power law model is used to characterize the rheological behavior of the aqueous solution. The mixing performance is investigated under different parameters, such as electric double layer thickness, flow behavior index, obstacle surface zeta potential, obstacle dimension. Due to the zeta potential heterogeneity at the obstacle surface, vortical flow is formed near the obstacle surface, which can significantly improve the mixing efficiency. The results show that, the mixing efficiency can be improved by increasing the obstacle surface zeta potential, the flow behavior index, the obstacle height, the EDL thickness.
- 14 April 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (4) , 431
Open AccessElectroosmotic Mixing of Non-Newtonian Fluid in a Microchannel with Obstacles and Zeta Potential Heterogeneity
This paper investigates the electroosmotic micromixing of non-Newtonian fluid in a microchannel with wall-mounted obstacles and surface potential heterogeneity on the obstacle surface. In the numerical simulation, the full model consisting of the Navier–Stokes equations and the Poisson–Nernst–Plank equations are solved for the electroosmotic fluid field, ion transport, and electric field, and the power law model is used to characterize the rheological behavior of the aqueous solution. The mixing performance is investigated under different parameters, such as electric double layer thickness, flow behavior index, obstacle surface zeta potential, obstacle dimension. Due to the zeta potential heterogeneity at the obstacle surface, vortical flow is formed near the obstacle surface, which can significantly improve the mixing efficiency. The results show that, the mixing efficiency can be improved by increasing the obstacle surface zeta potential, the flow behavior index, the obstacle height, the EDL thickness.