YLYadong Liu

Yadong Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yadong Liu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Yongtao Lyu

    Department of Orthopedics, Dalian Municipal Central Hospital Affiliated to Dalian University of Technology

    3 shared publications
  • Jun Hao

    First Affiliated Hospital of Dalian Medical University, Dalian, China

    2 shared publications
  • Sergei Bosiakov

    Faculty of Mechanics and Mathematics, Belarusian State University

    2 shared publications
  • Tao Yang

    First Affiliated Hospital of Dalian Medical University, Dalian, China

    2 shared publications
  • Xiaoling Geng

    Department of Gastroenterology & Hepatology, First Affiliated Hospital of Dalian Medical University, Dalian, 116000, People’s Republic of China

    2 shared publications
  • Yunfei Lan

    DUT-BSU Joint Institute, Dalian University of Technology

    2 shared publications

Latest Publications

  • Open Access

    Research on the energy absorption performance of diamond structures with axial and transverse porosity gradients under different load-bearing angles

    by Zhenjia Wang, Anas Hassan, Xuzhe Qiu, Yunfei Lan, Yongtao Lyu, Yadong Liu

    Background: In biomedical, aerospace, automotive and marine engineering, there is an increasing demand for high energy absorption behaviour in structures. Triply periodic minimal surface (TPMS) structures, such as Diamond lattices, have emerged as promising solutions due to their light weight nature and excellent energy absorption performance, and thus they have attracted significant research interest. Methods: This study explores the energy absorption characteristics and deformation behavior of Diamond structures with varying porosity distributions under different loading angles. Uniform and gradient Diamond structures with axial and transverse porosity distributions were generated. Quasi-static compression tests were performed on the uniform structures, while FE simulations were used to investigate the mechanical and energy-absorption responses of the uniform and gradient configurations. Quasi-static compression tests and finite element (FE) simulations were used to analyze the changes in energy absorption characteristics and deformation/damage modes during the compression process. Results: The results show that loading orientation and porosity-gradient direction strongly influence the energy-absorption response of Diamond structures. For the uniform structure, the SEA increased to approximately 8 kJ/kg at a loading angle of 30°, representing an increase of about 33% compared with the 0° and 15° configurations, while the corresponding plateau stress reached approximately 105 MPa. When the loading angle increased to 45°, the SEA decreased to approximately 4 kJ/kg because of earlier densification. Axial-gradient structures exhibited increased plateau stress and slightly enhanced SEA, but their maximum energy-absorption efficiency remained below approximately 35%, compared with about 40% for the uniform structures. Transverse-gradient structures showed plateau stresses comparable to those of the uniform structure with the corresponding average porosity, but tended to densify earlier, resulting in reduced SEA. Conclusion: These findings provide valuable insights into the design and optimization of Diamond structures for improved energy-absorption performance under different loading conditions and offer mechanical design guidance that may be relevant to the future development of TPMS structures for biomedical applications.

  • Open Access

    The size effect on mechanical and permeability properties of porous bone structures fabricated by selective laser melting

    by Yongtao Lyu, Hongrui Cao, Peiqi Jing, Yunfei Lan, Sergei Bosiakov, Haytham Elgazzar, Guangyu Li, Yadong Liu

    Porous structures are extensively utilized in bone tissue engineering for their lightweight nature, high strength-to-weight ratio, and superior energy absorption capacity. However, achieving optimal scaffold performance through precise dimension control remains a significant design challenge. This study systematically investigates the effect of unit-cell size on the mechanical and fluid transport properties of porous bone structures, aiming to provide guidance for scaffold design. Various porous structures with controlled unit cell sizes were fabricated via Selective Laser Melting (SLM) and evaluated under compressive loading. A complementary finite element (FE) model was developed to simulate mechanical responses and extract equivalent elastic modulus and compressive strength, while computational fluid dynamics (CFD) simulations were conducted on 4 × 4 × 4 arrays to calculate permeability. Results demonstrate that the Gyroid unit cell exhibited the most uniform stress distribution among the three studied architectures (Cube, Octa, Gyroid), and reducing unit cell size effectively mitigated stress concentrations to enhance structural stability. At a constant porosity, the compressive strength of uniform porous structures decreased with increasing unit-cell size, whereas the elastic modulus showed relatively low sensitivity to size variation. Meanwhile, permeability increased markedly with increasing unit-cell size. This study confirms that unit cell size profoundly impacts both the mechanical integrity and permeability of porous bone structures: smaller unit cells are recommended for applications prioritizing high compressive strength, whereas larger unit cells are more favorable for enhanced fluid transport.

  • Top Cited Papers
    Open Access

    A review on the auxetic mechanical metamaterials and their applications in the field of applied engineering

    by Volha Siniauskaya, Hao Wang, Yadong Liu, Yuhang Chen, Michael Zhuravkov, Yongtao Lyu

    Metamaterials are artificially created materials or structures with properties not found in nature. They encompass electromagnetic, acoustic, and mechanical metamaterials, which are particularly significant in applied engineering. Mechanical metamaterials exhibit unique mechanical properties such as vanishing shear modulus, negative Poisson’s ratio, negative compressibility, etc. This paper reviews the most commonly used mechanical metamaterials and discusses their applications in the field of applied engineering, specifically in vibration isolation, energy absorption, and vibration reduction. The prospects for future developments in this field are also presented.


  • Open Access

    Inverse design of anisotropic bone scaffold based on machine learning and regenerative genetic algorithm

    by Wenhang Liu, Youwei Zhang, Yongtao Lyu, Sergei Bosiakov, Yadong Liu

    Introduction: Triply periodic minimal surface (TPMS) is widely used in the design of bone scaffolds due to its structural advantages. However, the current approach to designing bone scaffolds using TPMS structures is limited to a forward process from microstructure to mechanical properties. Developing an inverse bone scaffold design method based on the mechanical properties of bone structures is crucial.Methods: Using the machine learning and genetic algorithm, a new inverse design model was proposed in this research. The anisotropy of bone was matched by changing the number of cells in different directions. The finite element (FE) method was used to calculate the TPMS configuration and generate a back propagation neural network (BPNN) data set. Neural networks were used to establish the relationship between microstructural parameters and the elastic matrix of bone. This relationship was then used with regenerative genetic algorithm (RGA) in inverse design.Results: The accuracy of the BPNN-RGA model was confirmed by comparing the elasticity matrix of the inverse-designed structure with that of the actual bone. The results indicated that the average error was below 3.00% for three mechanical performance parameters as design targets, and approximately 5.00% for six design targets.Discussion: The present study demonstrated the potential of combining machine learning with traditional optimization method to inversely design anisotropic TPMS bone scaffolds with target mechanical properties. The BPNN-RGA model achieves higher design efficiency, compared to traditional optimization methods. The entire design process is easily controlled.


  • Open Access

    Designing anisotropic porous bone scaffolds using a self-learning convolutional neural network model

    by Yongtao Lu, Tingxiang Gong, Zhuoyue Yang, Hanxing Zhu, Yadong Liu, Chengwei Wu

    The design of bionic bone scaffolds to mimic the behaviors of native bone tissue is crucial in clinical application, but such design is very challenging due to the complex behaviors of native bone tissues. In the present study, bionic bone scaffolds with the anisotropic mechanical properties similar to those of native bone tissues were successfully designed using a novel self-learning convolutional neural network (CNN) framework. The anisotropic mechanical property of bone was first calculated from the CT images of bone tissues. The CNN model constructed was trained and validated using the predictions from the heterogonous finite element (FE) models. The CNN model was then used to design the scaffold with the elasticity matrix matched to that of the replaced bone tissues. For the comparison, the bone scaffold was also designed using the conventional method. The results showed that the mechanical properties of scaffolds designed using the CNN model are closer to those of native bone tissues. In conclusion, the self-learning CNN framework can be used to design the anisotropic bone scaffolds and has a great potential in the clinical application.


  • Open Access

    MicroRNA-140-5p is Downregulated in Osteosarcoma and Overexpression of MicroRNA-140-5p Inhibits Cancer Cell Proliferation by Downregulating GLUT-1

    by Xiaoling Geng, Haoyu Wang, Lichen Xu, Yazhou Han, Yadong Liu

    Background: MicroRNA-140-5p plays pivotal role in different types of human malignancies, while its involvement in osteosarcoma is unknown. Objective: Our study aimed to investigate the functionality of microRNA-140-5p in osteosarcoma. Methods: Plasma levels of microRNA-140-5p and glucose transporter 1 (GLUT-1) in both osteosarcoma and healthy controls were measured by qRT-PCR and ELISA, respectively. Correlation between plasma levels of microRNA-140-5p and GLUT-1 was analyzed by Pearson correlation coefficient. Correlation between plasma levels of microRNA-140-5p and clinical data of patients with osteosarcoma was analyzed by Chi-square test. MicroRNA-140-5p mimic and GLUT-1 expression vector were transfected into cells of human osteosarcoma cell lines, and the effects on microRNA-140-5p expression, GLUT-1 expression and cell proliferation were analyzed by qRT-PCR, Western-blot and CCK-8 assay, respectively. Results: Plasma levels of microRNA-140-5p were significantly lower and plasma levels of GLUT-1 were significantly higher in osteosarcoma patients than that in healthy controls. Levels of plasma microRNA-140-5p and GLUT-1 were reversely correlated in osteosarcoma patients. Plasma levels of microRNA-140-5p were correlated with tumor size but not with other clinical data of patients. MicroRNA-140-5p mimic significantly inhibited cancer cell proliferation, while GLUT-1 overexpression significantly promoted cancer cell proliferation. MicroRNA-140-5p mimic significantly downregulated GLUT-1 expression. Conclusion: GLUT-1 overexpression showed no significant effect on microRNA-140-5p expression but attenuated the inhibitory effects of microRNA-140-5p mimic on cell proliferation. We therefore conclude that microRNA-140-5p is downregulated in osteosarcoma and overexpression of microRNA-140-5p may inhibit cancer cell proliferation by downregulating GLUT-1.


  • Open Access

    How to get better TAD? Relationship between anteversion angle of nail and position of femoral neck guide pin during nailing of intertrochanteric fractures

    by Zhe Wang, Yadong Liu, Shenglong Li, Xiuhui Wang, Changjian Liu, Xin Tang

    Background: To demonstrate the correlation between guide pin-shaft angle (PSA) at the anteroposterior film and anteversion angle of guide pin at the lateral film and investigate whether excellent tip–apex distance (TAD) can be obtained by changing the entry point via axial rotation of the main intramedullary nail. Methods: Fifty patients with intertrochanteric femoral fractures (IFFs) undergoing internal fixation with intramedullary nails under 2D fluoroscopy were retrospectively enrolled. Both of the PSA at the anteroposterior film and anteversion angle at the lateral film before and after adjustment of the guide pin were collected. Pearson correlation analysis was performed to investigate their correlation. Intraoperative and postoperative outcomes were recorded. Furthermore, the software of Mimics 10.0 and Pro/E were used to establish the 3D models of the proximal femur and main intramedullary nail/guide pin, respectively. Surgery was simulated on the Pro/E software platform and solid geometry analysis was conducted to calculate the correlation between the PSA and the anteversion angle. Results: Pearson correlation analysis indicated there was a positive correlation between PSA and anteversion angle, with the correlation coefficient of 0.902 (p < 0.01). By altering the PSA and anteversion angle, TAD was adjusted to be less than 25 mm in all patients. The mean operative time, fluoroscopy time and length of hospital stay were 65.82 ± 11.16 min, 2.03 ± 0.79 min and 6.66 ± 2.49 d. Thirty-one patients received blood transfusions (3.55 ± 1.95 U). Fracture reduction was considered to be good or acceptable in all patients. Complications occurred only in 6 patients (12.00%). At a 3-month follow-up, the mean Timed Up and Go was 31.54 ± 20.95 s and Harris Hip Score was 72.88 ± 8.79. The 3D surgery model also showed when the main intramedullary nail was externally rotated or internally rotated of 20° at the standard location, the PSA of guide pin at the anteroposterior position and anteversion angle of the guide pin at the lateral position were simultaneously increased or decreased. Conclusion: Our findings suggest altering the PSA and anteversion angle may be beneficial for obtaining excellent TAD and achieving superior outcomes.


  • Biomimetic poly(glycerol sebacate)/polycaprolactone blend scaffolds for cartilage tissue engineering

    by Yadong Liu, Kang Tian, Jun Hao, Tao Yang, Xiaoling Geng, Weiguo Zhang

    Poly (glycerol sebacate) (PGS) is a synthetic polymeric material with the characteristics of controllable degradation, high plasticity and excellent biocompatibility. However, the time of PGS degradation is faster than that of cartilage regeneration, which limits its application in cartilage tissue engineering. Polycaprolactone (PCL), a widely used synthetic polymer, has appropriate biodegradability and higher mechanical strength. This study aims to make a scaffold from blends of fast degrading PGS and slowly degrading PCL, and to investigate its potential for cartilage tissue engineering applications. Scanning electron microscopic analysis indicated that the scaffolds provided favourable porous microstructures. In vitro degradation test showed that PGS/ PCL scaffolds acquired longer degradation time and better mechanical strength. PGS/PCL scaffolds seeded with Bone marrow-derived mesenchymal stem cells (BMSCs) and articular chondrocytes (ACCs) were cultured in vitro. Short-term in vitro experiments confirmed that both seeded cells could adhere and proliferate on the scaffold. Chondrogenic culture for cell-scaffold constructs confirmed BMSCs could differentiate into chondrocyte-like cells in PGS/PCL scaffolds. With tunable biodegradation, favorable mechanical properties and cytocompatibility, PGS/PCL scaffolds would potentially be suitable for the regeneration of cartilage tissue.


  • Open Access

    (R)‑dehydroxyabscisic alcohol β‑D‑apiofuranosyl‑(1ˮ→6ʼ)‑β‑D‑glucopyranoside enhances the osteoblastic differentiation of ST2 cells via the BMP/WNT pathways

    by Yadong Liu, Tao Yang, Ting Chen, Jun Hao, Yu Gai, Weiguo Zhang

    Lonicera japonica has been used in traditional Chinese medicine as an important medicinal plant, with the ability to inhibit osteoclast development and bone loss. However, it is not clear which active ingredient exerts these effects. (R)‑dehydroxyabscisic alcohol β‑D‑apiofuranosyl‑(1ˮ→6ʼ)‑β‑D‑glucopyranoside (DAG) is an active constituent isolated from Lonicera japonica. In the present study, the ST2 bone marrow stromal cell line was treated by DAG at different concentrations and the osteoblastic differentiation was explored by ELISA assay, Von Kossa staining, Alizarin Red S staining, reverse transcription‑quantitative polymerase chain reaction and western blot analysis. The results revealed that DAG promoted osteoblastic differentiation, as evidenced by increasing mineralization and alkaline phosphatase (ALP) activity, as well as the expression of genes encoding bone differentiation markers, including Alp, osteopontin (Opn) and osteocalcin (Ocn). In addition, DAG upregulated the gene expression of bone morphogenetic protein (Bmp)‑2, Bmp4, Wnt family member (Wnt)‑1, Wnt3 and runt‑related transcription factor 2 (Runx2), as well as the protein expression of phosphorylated‑mothers against decapentaplegic homolog (Smad) 1, Smad5 Smad8, β‑catenin and Runx2 in ST2 cells. The osteogenic effects induced by DAG were attenuated by the BMP antagonist Noggin and the WNT signaling pathway inhibitor Dickkopf related protein‑1. The data indicated that DAG promoted the osteoblastic differentiation of ST2 cells, at least partially through regulating the BMP/WNT signaling pathways. This provides scientific rationale for the development of DAG as a treatment for bone loss‑associated diseases, such as osteoporosis.


  • Open Access

    miR‑491‑5p inhibits osteosarcoma cell proliferation by targeting PKM2

    by Ting Chen, Yuyang Li, Wenliang Cao, Yadong Liu

    Increasing evidence has indicated that microRNAs (miRNAs/miRs) are associated with tumorigenesis and the development of numerous cancer types. Previous studies have suggested miRNA‑491‑5p is downregulated in osteosarcoma (OS) and functions as a tumor suppressor. However, the biological roles and underlying mechanisms associated with miR‑491‑5p function in OS require further exploration. In the present study, it was demonstrated by reverse transcription‑quantitative polymerase chain reaction (RT‑qPCR) that miR‑491‑5p was downregulated in 36 pairs of OS tissues, compared with in adjacent normal bone tissues. Furthermore, CCK‑8 and colony formation assays indicated that miR‑491‑5p mimics suppressed OS cell proliferation. However, an miR‑491‑5p inhibitor enhanced cell proliferation. In addition, luciferase reporter assays, RT‑qPCR and western blot analysis demonstrated that PKM2 was a direct target of miR‑491‑5p. The miR‑491‑5p mimic inhibited the mRNA and protein expression of PKM2, while the miR‑491‑5p inhibitor promoted PKM2 mRNA and protein expression. In addition, PKM2 overexpression reversed the proliferation‑inhibiting effects of miR‑491‑5p in OS cells. Therefore, these results indicated that miR‑491‑5p serves as a tumor suppressor in OS cells, which may be important in OS treatment.