Yong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yong Zhou has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Changcheng Liu
School of Environment and Safety Engineering, North University of China, Taiyuan 030051, China
2 shared publications - Xudong Cheng
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China
2 shared publications Beijing 100037 Academy Of National Food And Strategic Reserves Administration
1 shared publicationCong Li
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, China
1 shared publicationFang Tang
1 shared publicationHeping Zhang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, China
1 shared publication
Latest Publications
- Open Access
Coupling Characteristics of Tandem Dual-Pool Fires Under Longitudinal Wind Based on an Optical-Length Radiation Model
This study investigates stable downstream-pool ignition, combustion-coupling enhancement, and radiative characteristics of separated tandem square ethanol pool fires under longitudinal wind. Experiments employed two pool sizes, four spacings (5–15 cm), and five wind speeds (0.7–2.5 m/s), together with corresponding single-pool baselines. Mass loss rate, local heat flux, and flame geometry were measured. Equivalent total heat feedback was inferred from the steady-state mass loss rate, while local and area-averaged incident radiation were evaluated using a tilted-flame view-factor model. Three apparent-emissivity correlations based on heat release rate, dimensionless pool diameter, and optical length were compared. Stable downstream burning was governed mainly by wind speed and spacing. Once stable burning was established, coupling enhancement did not increase monotonically as spacing decreased. For the 15 cm × 15 cm pool, the optical length and area-averaged view factor both peaked at S = 7 cm within the investigated spacing range, coinciding with the maxima in area-averaged incident radiative heat flux and mass loss rate. The optical-length-based emissivity model showed the most stable agreement with local heat-flux measurements. These results suggest that the enhanced burning response at S = 7 cm is associated with the combined effects of flame radiative capacity and geometric coupling under the investigated conditions.
Open AccessCoupling Characteristics of Tandem Dual-Pool Fires Under Longitudinal Wind Based on an Optical-Length Radiation Model
This study investigates stable downstream-pool ignition, combustion-coupling enhancement, and radiative characteristics of separated tandem square ethanol pool fires under longitudinal wind. Experiments employed two pool sizes, four spacings (5–15 cm), and five wind speeds (0.7–2.5 m/s), together with corresponding single-pool baselines. Mass loss rate, local heat flux, and flame geometry were measured. Equivalent total heat feedback was inferred from the steady-state mass loss rate, while local and area-averaged incident radiation were evaluated using a tilted-flame view-factor model. Three apparent-emissivity correlations based on heat release rate, dimensionless pool diameter, and optical length were compared. Stable downstream burning was governed mainly by wind speed and spacing. Once stable burning was established, coupling enhancement did not increase monotonically as spacing decreased. For the 15 cm × 15 cm pool, the optical length and area-averaged view factor both peaked at S = 7 cm within the investigated spacing range, coinciding with the maxima in area-averaged incident radiative heat flux and mass loss rate. The optical-length-based emissivity model showed the most stable agreement with local heat-flux measurements. These results suggest that the enhanced burning response at S = 7 cm is associated with the combined effects of flame radiative capacity and geometric coupling under the investigated conditions.
- 12 June 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (5) , 2543-2565
Scattering Characteristics of Fire Smoke and Dust Aerosol in Aircraft Cargo Compartment
- 12 June 2023
- Published by Springer Nature in Fire Technology
- Vol. 59 (5) , 2543-2565
Scattering Characteristics of Fire Smoke and Dust Aerosol in Aircraft Cargo Compartment
- Open Access
Improvement of the Thermal Insulation Performance of Silica Aerogel by Proper Heat Treatment: Microporous Structures Changes and Pyrolysis Mechanism
A simple heat treatment method was used to optimize the three-dimensional network structure of the hydrophobic aerogel, and during the heat treatment process at 200–1000 °C, the thermal conductivity of the aerogel reached the lowest to 0.02240 W/m·K between 250 °C and 300 °C, which was mainly due to the optimization of microstructure and pyrolysis of surface groups. Further Fluent heat-transfer simulation also confirmed the above results. Synchrotron vacuum ultraviolet photoionization mass spectrometry (SVUV-PIMS) was used to finely measure the pyrolysis process of aerogels, and the pyrolysis process of aerogel was divided into four stages. (I) Until 419 °C, as the temperature continued to rise, surface methyl groups were oxidized to form hydroxyl. (II) As the temperature reached to 232 °C, the oxidation proceeded. In addition, inside the aerogel, because of lacking oxygen, the reaction produced CH4 and C–Si bonds would form. (III) After 283 °C, Si–OH groups began to condense to form Si–O–Si, which optimized the three-dimensional network structures to be beneficial to improve the thermal insulation performance of silica aerogel. (IV) When it reached 547 °C, the chemical reaction was terminated, and all the primary particles gradually fused into secondary particles and sintered to form clusters.
Open AccessImprovement of the Thermal Insulation Performance of Silica Aerogel by Proper Heat Treatment: Microporous Structures Changes and Pyrolysis Mechanism
A simple heat treatment method was used to optimize the three-dimensional network structure of the hydrophobic aerogel, and during the heat treatment process at 200–1000 °C, the thermal conductivity of the aerogel reached the lowest to 0.02240 W/m·K between 250 °C and 300 °C, which was mainly due to the optimization of microstructure and pyrolysis of surface groups. Further Fluent heat-transfer simulation also confirmed the above results. Synchrotron vacuum ultraviolet photoionization mass spectrometry (SVUV-PIMS) was used to finely measure the pyrolysis process of aerogels, and the pyrolysis process of aerogel was divided into four stages. (I) Until 419 °C, as the temperature continued to rise, surface methyl groups were oxidized to form hydroxyl. (II) As the temperature reached to 232 °C, the oxidation proceeded. In addition, inside the aerogel, because of lacking oxygen, the reaction produced CH4 and C–Si bonds would form. (III) After 283 °C, Si–OH groups began to condense to form Si–O–Si, which optimized the three-dimensional network structures to be beneficial to improve the thermal insulation performance of silica aerogel. (IV) When it reached 547 °C, the chemical reaction was terminated, and all the primary particles gradually fused into secondary particles and sintered to form clusters.
- 1 January 2022
- Published by Journal of University of Science and Technology of China in JUSTC
- Vol. 52 (1) , 6-1-6-9
The control of moldy risk during rice storage based on multivariate linear regression analysis and random forest algorithm
Clarifying the mechanism of fungi growth is of great significance for maintaining the quality during grain storage. Among the factors that affect the growth of fungi spores, the most important factors are temperature, moisture content and storage time. Therefore, through this study, a multivariate linear regression model among several important factors, such as the spore number and ambient temperature, rice moisture content and storage days, were developed based on the experimental data. In order to build a more accurate model, we introduce a random forest algorithm into the fungal spore prediction during grain storage. The established regression models can be used to predict the spore number under different ambient temperature, rice moisture content and storage days during the storage process. For the random forest model, it could control the predicted value to be of the same order of magnitude as the actual value for 99% of the original data, which have a high accuracy to predict the spore number during the storage process. Furthermore, we plot the prediction surface graph to help practitioners to control the storage environment within the conditions in the low risk region.
- 1 January 2022
- Published by Journal of University of Science and Technology of China in JUSTC
- Vol. 52 (1) , 6-1-6-9
The control of moldy risk during rice storage based on multivariate linear regression analysis and random forest algorithm
Clarifying the mechanism of fungi growth is of great significance for maintaining the quality during grain storage. Among the factors that affect the growth of fungi spores, the most important factors are temperature, moisture content and storage time. Therefore, through this study, a multivariate linear regression model among several important factors, such as the spore number and ambient temperature, rice moisture content and storage days, were developed based on the experimental data. In order to build a more accurate model, we introduce a random forest algorithm into the fungal spore prediction during grain storage. The established regression models can be used to predict the spore number under different ambient temperature, rice moisture content and storage days during the storage process. For the random forest model, it could control the predicted value to be of the same order of magnitude as the actual value for 99% of the original data, which have a high accuracy to predict the spore number during the storage process. Furthermore, we plot the prediction surface graph to help practitioners to control the storage environment within the conditions in the low risk region.
- Open Access
Experimental Thermal Hazard Investigation of Pressure and EC/PC/EMC Mass Ratio on Electrolyte
Electrolytes are involved in the thermal runaway (TR) process of cells, which is a potential hazard in lithium-ion batteries (LIBs). Therefore, the effects of different mass ratio of carbonate solvents (ethylene carbonate (EC)/propylene carbonate (PC)/ethyl methyl carbonate (EMC)) with LiBF4 and different environmental pressure on the combustion characteristics of electrolyte such as flame centerline temperature, mass loss rate (MLR) and heat release rate (HRR) were analyzed. The combustion process could be divided into four stages: ignition, stable combustion stage, stable combustion with flame color change stage and extinguishing; with the decrease of pressure, the MLR of electrolyte declined and the combustion time prolonged, while the temperature of flame centerline increased.
Open AccessExperimental Thermal Hazard Investigation of Pressure and EC/PC/EMC Mass Ratio on Electrolyte
Electrolytes are involved in the thermal runaway (TR) process of cells, which is a potential hazard in lithium-ion batteries (LIBs). Therefore, the effects of different mass ratio of carbonate solvents (ethylene carbonate (EC)/propylene carbonate (PC)/ethyl methyl carbonate (EMC)) with LiBF4 and different environmental pressure on the combustion characteristics of electrolyte such as flame centerline temperature, mass loss rate (MLR) and heat release rate (HRR) were analyzed. The combustion process could be divided into four stages: ignition, stable combustion stage, stable combustion with flame color change stage and extinguishing; with the decrease of pressure, the MLR of electrolyte declined and the combustion time prolonged, while the temperature of flame centerline increased.
- 4 May 2017
- Published by Wiley in Fire and Materials
- Vol. 41 (7) , 826-833
Experimental study on fire behaviors of external thermal insulation composite system under vertical radiation
- 4 May 2017
- Published by Wiley in Fire and Materials
- Vol. 41 (7) , 826-833
Experimental study on fire behaviors of external thermal insulation composite system under vertical radiation