JRJos M. Rooijackers

Jos M. Rooijackers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jos M. Rooijackers has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Home environment exposure assessment in hypersensitivity pneumonitis

    by Jos M. Rooijackers, Vanessa Zaat, Marcel Veltkamp, Martin Meijer, Jos Houbraken, Emeline Scherer, Gabriel Reboux, Jan Grutters

    Objective: To identify the causal agent in hypersensitivity pneumonitis. Method: Between 2015 and 2020 an occupational hygienist performed an exposure assessment in the home environment of patients with hypersensitivity pneumonitis (HP), in whom common causes of HP were excluded. If indicated, work place exposure was assessed. Indoor and outdoor air samples were analysed for fungi. In the case of qualitative or quantitative abnormal patterns in the analysed samples indicating the presence of an etiologic agent, serology (double diffusion/Ouchterlony and electrosyneresis on cellulose acetate) was performed for general panels and specific fungi. Results: Assessment was performed in 41 patients (23-73 yrs). In 8 (20%) a source and causal agent was identified in the home environment, in two cases results were controversial. Main sources were carpets, mouldy bathrooms, poorly maintained dwellings and a car air conditioning. Among causal agents were Aspergillus spp., Penicillium sp., Wallemia sebi, Botrytis cinerea, Trichoderma pseudokoningii, Cephalotrichum sp., Thermoactinomyces vulgaris and goose feathers. Additional exposure assessment in the work place was performed in 8 patients, which revealed a causal agent in another 3 cases and one controversial finding. Sampling repeated in 2 cases after removal of the source showed that the causal agent was no longer present. Conclusion: A causal agent was identified in at least 25% of patients with HP. Standard protocols for indoor air sampling and individual tailored serology may contribute to the diagnosis of HP and intervention (Reboux G, et al. Indoor Air 2019; 29:5-16). This study is part of ZonMw project Topzorg, PRJ140088


  • Air Pollution from Livestock Farms is Associated with Airway Obstruction in Neighboring Residents

    by Floor Borlée, C. Joris Yzermans, Bernadette Aalders, Jos Rooijackers, Esmeralda Krop, Catharina B. M. Maassen, François Schellevis, Bert Brunekreef, Dick Heederik, Lidwien A. M. Smit

    Rationale: Livestock farm emissions may not only affect respiratory health of farmers but also of neighboring residents. Objectives: To explore associations between spatial and temporal variation in pollutant emissions from livestock farms and lung function in a general, nonfarming, rural population in the Netherlands. Methods: We conducted a cross-sectional study in 2,308 adults (age, 20–72 yr). A pulmonary function test was performed measuring prebronchodilator and post-bronchodilator FEV1, FVC, FEV1/FVC, and maximum mid-expiratory flow (MMEF). Spatial exposure was assessed as (1) number of farms within 500 m and 1,000 m of the home, (2) distance to the nearest farm, and (3) modeled annual average fine dust emissions from farms within 500 m and 1,000 m of the home address. Temporal exposure was assessed as week-average ambient particulate matter <10 μm in diameter and ammonia (NH3) concentrations before lung function measurements. Data were analyzed with generalized additive models (smoothing). Measurements and Main Results: A negative association was found between the number of livestock farms within a 1,000-m buffer from the home address and MMEF, which was more pronounced in participants without atopy. No associations were found with other spatial exposure variables. Week-average particulate matter <10 μm in diameter and NH3 levels were negatively associated with FEV1, FEV1/FVC, and MMEF. In a two-pollutant model, only NH3 remained associated. A 25-μg/m3 increase in NH3 was associated with a 2.22% lower FEV1 (95% confidence interval, −3.69 to −0.74), FEV1/FVC of −1.12% (−1.96 to −0.28), and MMEF of −5.67% (−8.80 to −2.55). Conclusions: Spatial and temporal variation in livestock air pollution emissions are associated with lung function deficits in nonfarming residents.


    • 3 June 2006
      • Vol. 150  (22) , 1238-42

    [The Netherlands Expertise Center for Occupational and Respiratory Disorders].

    by J M Rooyackers

    In 2000 the Netherlands Expertise Centre for Occupational Respiratory Disorders (NECORD) was started as a centre of expertise in occupational health. The centre received a grant from the ministry of Health Welfare and Sport for a period of 5 years. Their mission was to collect, develop and implement knowledge in the fields of diagnosis, treatment, reintegration and prevention of work-related health- and occupational disorders. In cooperation with two other institutes for health, NECORD has become a multidisciplinary clinical occupational respiratory health service. Occupational hygienists, occupational health physicians and chest physicians are working on three programmes: research projects on the prevalence and monitoring of respiratory health effects resulting from exposure to substances in the work place; patient care (out-patient clinic); and support of professionals (website, helpdesk, development and implementation of guidelines, education and postgraduate training).