Gábor Bencsik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gábor Bencsik has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Róbert Pap
Department of Internal Medicine, Cardiology Center, Division of Electrophysiology University of Szeged Szeged Hungary
3 shared publications - Attila Makai
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
2 shared publications - Attila Benak
Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, 6725 Szeged, Hungary
1 shared publication - Dóra Krányák
University of Szeged, Department of Internal Medicine, Cardiology Center, Division of Electrophysiology, Szeged, Hungary
1 shared publication Előd-János Zsigmond
1 shared publication- Flora Diana Gausz
University of Szeged, Department of Internal Medicine, Cardiology Center, Division of Electrophysiology, Szeged, Hungary
1 shared publication
Latest Publications
- Open Access
- 1 December 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (12) , 386
Arrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. Results: A total of 256 patients (mean age 64 ± 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 ± 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371–21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737–4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. Conclusion: VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
- 1 December 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (12) , 386
Open AccessArrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. Results: A total of 256 patients (mean age 64 ± 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 ± 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371–21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737–4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. Conclusion: VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
- 1 January 2023
- Published by Cardiologia Hungarica in Cardiologia Hungarica
- Vol. 53 (3) , 218-224
Hogyan érjünk el tartós pulmonalisvéna-izolációt fokális rádiófrekvenciás ablációval?
- 1 January 2023
- Published by Cardiologia Hungarica in Cardiologia Hungarica
- Vol. 53 (3) , 218-224
Hogyan érjünk el tartós pulmonalisvéna-izolációt fokális rádiófrekvenciás ablációval?
- 19 May 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (10) , 1709
Septally located left atrial hematoma as a consequence of a steam pop
- 19 May 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (10) , 1709
Septally located left atrial hematoma as a consequence of a steam pop
- Open Access
- 24 December 2014
- Published by Bentham Science Publishers Ltd. in Current Cardiology Reviews
- Vol. 11 (2) , 127-33
Novel strategies in the ablation of typical atrial flutter: role of intracardiac echocardiography.
Abstract: Radiofrequency ablation (RFA) of the cavo-tricuspid isthmus (CTI) is one of the most frequently performed procedures in electrophysiology. Despite a high success rate, ablation of the CTI can be unusually difficult in some cases. Multiple tools like angiography, 3D mapping, remote navigation and intracardiac echocardiography (ICE) have been introduced to facilitate typical flutter ablation. This review article summarizes the clinical value of different strategies and tools used for CTI ablation focusing on the importance of approaches utilizing ICE.
- 24 December 2014
- Published by Bentham Science Publishers Ltd. in Current Cardiology Reviews
- Vol. 11 (2) , 127-33
Open AccessNovel strategies in the ablation of typical atrial flutter: role of intracardiac echocardiography.
Abstract: Radiofrequency ablation (RFA) of the cavo-tricuspid isthmus (CTI) is one of the most frequently performed procedures in electrophysiology. Despite a high success rate, ablation of the CTI can be unusually difficult in some cases. Multiple tools like angiography, 3D mapping, remote navigation and intracardiac echocardiography (ICE) have been introduced to facilitate typical flutter ablation. This review article summarizes the clinical value of different strategies and tools used for CTI ablation focusing on the importance of approaches utilizing ICE.
- 17 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (5) , 614-616
Supraventricular Tachycardia Inducible Only with Para‐Hisian Pacing—What Is the Mechanism?
- 17 November 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (5) , 614-616
Supraventricular Tachycardia Inducible Only with Para‐Hisian Pacing—What Is the Mechanism?