DCDean Cutajar

Dean Cutajar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dean Cutajar has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Playing Hard with Si: Challenges and Opportunities for New Materials in Radiation Therapy Dosimetry

    by James Cayley, Ilia Filipev, Jeremy A. Davis, Vincent de Rover, Dean Cutajar, Enbang Li, Bradley M. Oborn, Marco Petasecca, Anatoly Rosenfeld, Michael L. F. Lerch

    The sophistication and diversity of radiation medicine modalities continue to increase significantly in both cancer imaging and cancer radiation therapy. With over 50% of cancer patients receiving some form of radiation procedure as part of their cancer management plan, the importance and impact of quantitative radiation detector systems for quality assurance in radiation medicine should not be underestimated. There are numerous challenges faced by silicon‐based detector systems used for dosimetry in radiation therapy that are discussed in this review article, especially considering emerging radiation therapy modalities that incorporate ultra‐high irradiation dose‐rates (e.g., MRT, FLASH‐RT, VHEE‐RT), while others utilize mixed radiation fields (e.g., proton‐RT, heavy ion therapy) or diffusion‐based dose delivery techniques (e.g., Alpha DaRT). Such challenges create exciting opportunities for new radiation detector materials. This concise review paper explores the role of silicon in radiation detection applications and highlights the challenges it faces in achieving optimal performance. Additionally, this review discusses new materials that are emerging as strong candidates for the next generation of radiation detectors, emphasizing both the opportunities and challenges associated with these materials.


  • Open Access

    Establishing Linearity of the MOSkin Detector for Ultra-High Dose-per-Pulse, Very-High-Energy Electron Radiotherapy Using Dose-Rate-Corrected EBT-XD Film

    by James Cayley, Elette Engels, Tessa Charles, Paul Bennetto, Matthew Cameron, Joel Poder, Daniel Hausermann, Jason Paino, Duncan Butler, Dean Cutajar, et al.

    Very-high-energy electrons, coupled with ultra-high dose rates, are being explored for their potential use in radiotherapy to treat deep-seated tumours. The dose per pulse needed to achieve ultra-high dose rates far exceeds the limit of current medical linear accelerator capabilities. A high dose per pulse has been observed as the limiting factor for many existing dosimeters, resulting in saturation at doses far below what is required. The MOSkin, an existing clinical quality assurance dosimeter, has previously been demonstrated as dose rate independent but has not been subjected to a high dose per pulse. Within this study, the MOSkins dose-per-pulse response was tested for linearity, with a dose per pulse as high as 23 Gy within 200 ns at the ANSTO Australian Synchrotron’s Pulsed Energetic Electrons for Research facility. While using EBT-XD film as a reference dosimeter, a dose rate dependence of the EBT-XD was discovered. Once confirmed and a correction factor established, EBT-XD was used as an independent reference measurement. This work presents confirmation of the MOSkin suitability for ultra-high dose-rate environments with an electron energy of 100 MeV, and a theoretical discussion of its dose-rate and dose-per-pulse independence; the MOSkin is the only detector suitable for both clinical quality assurance, and ultra-high dose-rate measurements in its standard, unmodified form.


  • Open Access

    Electron streaming dose measurements and calculations on a 1.5 T MR‐Linac

    by Elizabeth Patterson, Marcus Powers, Peter E. Metcalfe, Dean Cutajar, Bradley M. Oborn, John A. Baines

    Purpose: To evaluate the accuracy of different dosimeters and the treatment planning system (TPS) for assessing the skin dose due to the electron streaming effect (ESE) on a 1.5 T magnetic resonance (MR)‐linac.Method: Skin dose due to the ESE on an MR‐linac (Unity, Elekta) was investigated using a solid water phantom rotated 45° in the x‐y plane (IEC61217) and centered at the isocenter. The phantom was irradiated with 1 × 1, 3 × 3, 5 × 5, 10 × 10, and 22 × 22 cm2 fields, gantry at 90°. Out‐of‐field doses (OFDs) deposited by electron streams generated at the entry and exit surface of the angled phantom were measured on the surface of solid water slabs placed ±20.0 cm from the isocenter along the x‐direction. A high‐resolution MOSkin™ detector served as a benchmark due to its shallower depth of measurement that matches the International Commission on Radiological Protection (ICRP) recommended depth for skin dose assessment (0.07 mm). MOSkin™ doses were compared to EBT3 film, OSLDs, a diamond detector, and the TPS where the experimental setup was modeled using two separate calculation parameters settings: a 0.1 cm dose grid with 0.2% statistical uncertainty (0.1 cm, 0.2%) and a 0.2 cm dose grid with 3.0% statistical uncertainty (0.2 cm, 3.0%).Results: OSLD, film, the 0.1 cm, 0.2%, and 0.2 cm, 3.0% TPS ESE doses, underestimated skin doses measured by the MOSkin™ by as much as –75.3%, –7.0%, –24.7%, and –41.9%, respectively. Film results were most similar to MOSkin™ skin dose measurements.Conclusions: These results show that electron streams can deposit significant doses outside the primary field and that dosimeter choice and TPS calculation settings greatly influence the reported readings. Due to the steep dose gradient of the ESE, EBT3 film remains the choice for accurate skin dose assessment in this challenging environment.


  • Open Access

    High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac

    by E. Patterson, P. Stokes, D. Cutajar, A. Rosenfeld, J. Baines, P. Metcalfe, M. Powers

    The magnetic field of a transverse MR-linac alters electron trajectories as the photon beam transits through materials, causing lower doses at flat entry surfaces and increased doses at flat beam-exiting surfaces. This study investigated the response of a MOSFET detector, known as the MOSkin™, for high-resolution surface and near-surface percentage depth dose measurements on an Elekta Unity. Simulations with Geant4 and the Monaco treatment planning system (TPS), and EBT-3 film measurements, were also performed for comparison. Measured MOSkin™ entry surface doses, relative to Dmax, were (9.9 ± 0.2)%, (10.1 ± 0.3)%, (11.3 ± 0.6)%, (12.9 ± 1.0)%, and (13.4 ± 1.0)% for 1 × 1 cm2, 3 × 3 cm2, 5 × 5 cm2, 10 × 10 cm2, and 22 × 22 cm2 fields, respectively. For the investigated fields, the maximum percent differences of Geant4, TPS, and film doses extrapolated and interpolated to a depth suitable for skin dose assessment at the beam entry, relative to MOSkin™ measurements at an equivalent depth were 1.0%, 2.8%, and 14.3%, respectively, and at a WED of 199.67 mm at the beam exit, 3.2%, 3.7% and 5.7%, respectively. The largest measured increase in exit dose, due to the electron return effect, was 15.4% for the 10 × 10 cm2 field size using the MOSkin™ and 17.9% for the 22 × 22 cm2 field size, using Geant4 calculations. The results presented in the study validate the suitability of the MOSkin™ detector for transverse MR-linac surface dosimetry.


  • Application of an SOI Microdosimeter for Monitoring of Neutrons in Various Mixed Radiation Field Environments

    by V. A. Pan, J. Vohradsky, B. James, F. Pagani, L. Chartier, E. Debrot, Z. Pastuovic, D. Cutajar, J. Poder, M. Nancarrow, et al.

    Radiation monitoring in space radiation is complex due to galactic cosmic rays (GCRs), solar particle events (SPEs), and albedo particles. Thermal neutrons are an important component in the Moon radiation albedo field which can cause single event upset (SEU) in electronics when they interact with the 10 B present in electronic components. In this work, we studied an application of silicon on insulator (SOI) microdosimeters for neutron monitoring in various mixed radiation field environments. A 10- $\mu \text{m}$ SOI microdosimeter was utilized in conjunction with a 10 B 4 C thin-film converter to successfully measure the thermal neutron contribution out of field of a therapeutic proton beam as well as an 18-MV X-ray linear accelerator (LINAC). The microdosimeter was placed downstream of the Bragg peak (BP) as well as laterally out of field of the proton beam and at two positions along the treatment couch of the 18-MV LINAC. It was demonstrated that the 10- $\mu \text{m}$ SOI microdosimeter with 10 B 4 C converter is suitable for detection of thermal neutrons with excellent discrimination of gamma, fast and thermal neutron components in the presence of a gamma-neutron pulsed field of an 18-MV LINAC. To reduce the gamma contribution and further improve detection of neutrons in mixed radiation fields, a new $2 ~\mu \text{m}$ Mushroom-planar microdosimeter was fabricated and characterized in detail using an ion beam induced charge collection (IBIC) technique with 1.78 MeV $\text{H}e^{\mathrm {2+}}$ ions. It was demonstrated that this $2 ~\mu \text{m}$ SOI microdosimeter can be operated in a passive mode. The SOI microdosimeter with the 10 B 4 C converter can be recommended for the detection of thermal neutrons for SEU prediction in the mixed gamma-neutron fields during space missions, especially for the Moon mission.


  • Towards real time in-vivo rectal dosimetry during trans-rectal ultrasound based high dose rate prostate brachytherapy using MOSkin dosimeters

    by Joel Poder, Andrew Howie, Ryan Brown, Joseph Bucci, Anatoly Rosenfeld, Komiti Enari, Kristine Schreiber, Mauro Carrara, Andrej Bece, David Malouf, et al.


  • A Monte Carlo study on the feasibility of real-time in vivo source tracking during ultrasound based HDR prostate brachytherapy treatments

    by Joel Poder, Dean Cutajar, Susanna Guatelli, Marco Petasecca, Andrew Howie, Joseph Bucci, Mauro Carrara, Anatoly Rosenfeld


  • Dosimetric effects of brass mesh bolus on skin dose and dose at depth for postmastectomy chest wall irradiation

    by Zakiya S. Al-Rahbi, Dean L. Cutajar, Peter Metcalfe, Anatoly B. Rosenfeld


  • Applications of MOSkin dosimeters for quality assurance in gynecological HDR brachytherapy: An in-phantom feasibility study

    by Anna A. Romanyukha, Mauro Carrara, Chiara Tenconi, Davide Mazzeo, Giulio Rossi, Marta Borroni, Emanuele Pignoli, Annamaria Cerrotta, Dean Cutajar, Marco Petasecca, et al.


  • Comparison of phantom materials for use in quality assurance of microbeam radiation therapy

    by Matthew Cameron, Iwan Cornelius, Dean Cutajar, Jeremy Davis, Anatoly Rosenfeld, Michael Lerch, Susanna Guatelli

    Microbeam radiation therapy (MRT) is a promising radiotherapy modality that uses arrays of spatially fractionated micrometre-sized beams of synchrotron radiation to irradiate tumours. Routine dosimetry quality assurance (QA) prior to treatment is necessary to identify any changes in beam condition from the treatment plan, and is undertaken using solid homogeneous phantoms. Solid phantoms are designed for, and routinely used in, megavoltage X-ray beam radiation therapy. These solid phantoms are not necessarily designed to be water-equivalent at low X-ray energies, and therefore may not be suitable for MRT QA. This work quantitatively determines the most appropriate solid phantom to use in dosimetric MRT QA. Simulated dose profiles of various phantom materials were compared with those calculated in water under the same conditions. The phantoms under consideration were RMI457 Solid Water (Gammex-RMI, Middleton, WI, USA), Plastic Water (CIRS, Norfolk, VA, USA), Plastic Water DT (CIRS, Norfolk, VA, USA), PAGAT (CIRS, Norfolk, VA, USA), RW3 Solid Phantom (PTW Freiburg, Freiburg, Germany), PMMA, Virtual Water (Med-Cal, Verona, WI, USA) and Perspex. RMI457 Solid Water and Virtual Water were found to be the best approximations for water in MRT dosimetry (within ±3% deviation in peak and 6% in valley). RW3 and Plastic Water DT approximate the relative dose distribution in water (within ±3% deviation in the peak and 5% in the valley). PAGAT, PMMA, Perspex and Plastic Water are not recommended to be used as phantoms for MRT QA, due to dosimetric discrepancies greater than 5%.