MHMeredith C. Henderson

Meredith C. Henderson

*This is an algorithmically generated author record based on publicly available information.

Meredith C. Henderson has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Age-related variations: A retrospective analysis of 851 prospectively collected patient samples to determine the benefit of combining combinatorial protein biomarker assay for risk assessment in women with dense breast.

    by David Emery Reese, Michael Silver, Meredith C. Henderson, Sherri Borman, Christa Corn, Rao Mulpuri, Kasey Benson

    27 Background: Clinicians often experience difficulty in differentiating benign lesions from invasive breast cancers in patients designated as dense breast. A major limitation of radiological breast cancer screening methods involves a decrease in sensitivity and specificity in women with dense breast. Thus, we sought to test whether Klarify Breast, a combinatorial protein-based biomarker panel could improve early detection of significant breast lesions in a controlled fashion. Clearly, a diagnostic assay that would provide biochemical evidence in the patient’s clinical course is greatly needed. Methods: We have conducted two independent, multi-center, prospective clinical trials to establish the clinical validity of Klarify Breast – an assay that uses multiple Serum Protein Biomarkers (SPBs), Tumor-Associated Autoantibodies (TAAbs), patient specific clinical data and develop a score to differentiate patients with benign breast disease from those with invasive breast cancer. Independent panels of biomarkers and associated algorithms were developed using prospectively collected samples from women under age 50 (n = 351) and from women ages 25-75 (n = 500). Here, we present the benefit of integrating the results of Klarify Breast test with patient imaging to best assess risk in women with dense breast. Results: While performance of the assay was somewhat age dependent (women under the age of 50 demonstrated a higher sensitivity and specificity than women over the age of 50). Here we present data that both groups of women clearly benefit from the addition of a biomarker assay combined with standard of care imaging in identifying invasive breast lesions. Conclusions: Clearly, in women with dense breast, where radiologic studies alone do not permit full assessment in women with a dense breast finding. The biomarker test here, comprised of TAAbs and SPBs, offers a clear advantage in terms of NPV, PPV, Sensitivity and specificity. The results argue strongly for the use of appropriate biomarkers to augment imaging based breast cancer screening in women with dense breast or those who are at high risk. Clinical trial information: NCT01839045, NCT02078570.

  • Use of serum biomarkers to differentiate benign breast lesions from invasive breast cancer in women with a BI-RADS 3 or 4.

    by Meredith C. Henderson, Michael Silver, Susan Yeh, Christa Corn, Sherri Borman, David Emery Reese

    20 Background: The Provista Biomarker Assay (PBA) combines multiple serum biomarkers, measured at high sensitivity, in order to determine the likelihood of an invasive breast tumor at the time of testing. PBA, when paired with traditional breast imaging technologies, provides a biochemical tool that can help guide additional imaging or biopsy decisions. As part of our ongoing efforts to characterize clinical performance, we conducted a proof-of-concept study wherein PBA assay performance was tested in prospectively enrolled BI-RADS 3 and 4 patients. Methods: To maximize performance and sensitivity, we utilized the Meso Scale Discovery ELISA-based system to analyze a randomized cohort of 350 prebiopsy serum samples from women under the age of 50. Enrollment in the trial required a BI-RADS 3 or 4 radiologic assessment utilizing multiple imaging modalities. Serum proteins and autoantibodies were measured for each patient and applied to a proprietary statistical algorithm. Results: We were able to obtain statistically significant differentiation using the Provista Biomarker Assay in women under age 50 who were characterized as BI-RADS 3 or 4. The majority of patients in the study were diagnosed with a benign breast lesion, consistent with prior studies. However, the data indicate that PBA, when used in combination with imaging techniques, more accurately informs clinical decision-making. Conclusions: The Provista Biomarker Assay provides a powerful tool for physicians to more accurately assess patients with a BI-RADS 3 or 4 classification. With more clinical evidence, the assay may translate into changes in clinical treatment decisions for women under the age of 50 with a BI-RADS 3 or 4 classification. Clinical trial information: NCT01839045.

  • Combining serum autoantibody measurements with traditional serum biomarkers for the detection of invasive breast cancer.

    by Meredith C. Henderson, David Emery Reese, Sherri Borman, Susan Yeh, Alan Hollingsworth

    13 Background: The use of protein biomarkers for serum-based detection of invasive breast cancer has been problematic due in large part to intrinsic variability in the population as a whole. The Provista Biomarker Assay (PBA) has been shown previously to be highly sensitive across a wide spectrum of clinical signals. The detection of autoantibodies (AAb) holds great promise due to the inherent specificity these biomarkers provide. However, as a clinical-quality diagnostic, it is necessary to utilize a panel comprised of multiple autoantibodies, as individual sensitivity is general low. Our hypothesis was that combining serum protein and autoantibodies together in a panel would result in an increased ability to correctly identify breast cancer. Methods: To maximize clinical performance (sensitivity and specificity), we utilized the Meso Scale Discovery ELISA-based system to measure AAbs from patient sera. We analyzed 134 prospectively collected patient serum samples for a variety of autoantibody targets. These data, together with serum protein biomarker concentrations, produced an analytically robust test that is also highly specific. Results: Consistent with our hypothesis, the inclusion of autoantibodies with serum proteins in the Provista Biomarker Assay improved test specificity above that observed in serum protein biomarkers alone. Individual protein targets had limited ability to differentiate benign conditions from invasive breast cancer. However, factoring in autoantibody values resulted in improved overall accuracy to differentiate serum from benign and invasive breast cancer patients. Conclusions: In the novel approach of combining these two different classes of analytes, we exploit the specificity of AAbs while maintaining high sensitivity through the inclusion of more generalized cancer-associated protein biomarkers. The combination of these two approaches clearly offers unique performance benefits in the early detection of invasive breast cancer that is greater than either component alone.

  • dtectDx Breast: A serum biomarker test for breast cancer detection used in conjunction with traditional mammography screening.

    by Meredith C. Henderson, Keri Sweeten, Sherri Borman, Christa Corn, Lindsey Gordon, David E. Reese

    18 Background: Provista Diagnostics has developed a test that analyzes serum concentrations of 5 protein biomarkers in order to detect breast cancer. The dtectDx Breast test utilizes a proprietary algorithm that has been described previously (Weber et al. 2010). In this study, it was noted that the algorithm performs best in women under age 50. The aim of this study was to evaluate the performance characteristics of dtectDx Breast in women under age 50 in a commercial setting and compare the results with data from the previous clinical study. Methods: The dtectDx Breast test measures the concentrations of IL-8, IL-12, VEGF, CEA, and HGF via ELISA. These data combined with select patient characteristics and Provista’s proprietary algorithm result in a test value that is characterized as normal or elevated. dtectDx Breast test reports issued for women under age 50 were reviewed from a 3-year time period and prescribing physicians were interviewed regarding follow-up care and outcome measures (largely imaging studies, if warranted). Results: Of the 908 patients, 8 samples were rejected based on serum quality. Of the remaining 900 patients, 121 were reported as elevated (12.7%). In 4 cases, these elevated results were confirmed cases of breast cancer. Of these, 2 patients initially showed no screening evidence of cancer, but upon further evaluation (after receipt of dtectDx Breast results) were diagnosed with breast cancer. dtectDx correctly identified DCIS 66% of the time (n=2). Conclusions: These results describe the use of dtectDx Breast in a clinical setting and confirm that the assay behaves similarly to previously published results (Weber et al 2010). While the false-positive rate is higher than predicted (12.7% vs 6.8%), the assay correctly identified 4 of 4 invasive cancers and 2 of 3 DCIS cases. Since two of the invasive cancer cases were originally not detected via standard screening procedures, the assay has demonstrated important clinical utility when used in conjunction with mammography/standard of care. Here we show that, in the commercial patient population, when combined with standard of care, dtectDx Breast improves the detection of breast cancer in women under 50.