Wojciech Cepiński
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wojciech Cepiński has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Paweł Szałański
Department of Air Conditioning, Heating, Gas Engineering and Air Protection, Faculty of Environmental Engineering, Wrocław University of Science and Technology, 4/6 C.K. Norwida Street, 50-373 Wrocław, Poland
7 shared publications - Maciej Besler
Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
3 shared publications - Piotr Kęskiewicz
Department of Air Conditioning, Heating, Gas Engineering, and Air Protection, Faculty of Environmental Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
3 shared publications - Magdalena Orłowska
Koszalin University of Technology, Poland
2 shared publications - Piotr Kowalski
Department of Air Conditioning, Heating, Gas Engineering and Air Protection, Faculty of Environmental Engineering, Wrocław University of Science and Technology, 4/6 C.K. Norwida st. 50-373 Wrocław, Poland
2 shared publications Bartosz Szmigiero
Wrocław University of Science and Technology, Faculty of Environmental Engineering, Department of Air Conditioning, Heating, Gas Engineering and Air Protection, 4/6 Norwida st., 50-373 Wrocław, Poland
1 shared publication
Latest Publications
- Open Access
- 24 November 2025
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 27, 705-721
Testing the Temperature Fields and Power of a Flat Radiator Covered With and Without a Curtain
The article presents the results of experimental studies on a flat plate radiator. The influence of curtains made of materials of different structures and permeabilities on the temperature fields in the space around the radiator and the heating power of the radiator was checked. Temperature studies concern the gap between the front panel of the radiator and the hung material. The heating power was calculated for the individual variants tested (with or without a cover). The highest heating power was shown to be achieved by the radiator without a cover, which was 319.8 W. The radiator with guipure cover had 319.3 W, while the lowest power was achieved by the radiator with cotton curtain, which was 277.0 W. Based on the experiment conducted, screening factors were given. They were established in relation to the curtains tested and their effect on the heat power of the radiator.
- 24 November 2025
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 27, 705-721
Open AccessTesting the Temperature Fields and Power of a Flat Radiator Covered With and Without a Curtain
The article presents the results of experimental studies on a flat plate radiator. The influence of curtains made of materials of different structures and permeabilities on the temperature fields in the space around the radiator and the heating power of the radiator was checked. Temperature studies concern the gap between the front panel of the radiator and the hung material. The heating power was calculated for the individual variants tested (with or without a cover). The highest heating power was shown to be achieved by the radiator without a cover, which was 319.8 W. The radiator with guipure cover had 319.3 W, while the lowest power was achieved by the radiator with cotton curtain, which was 277.0 W. Based on the experiment conducted, screening factors were given. They were established in relation to the curtains tested and their effect on the heat power of the radiator.
- Open Access
Effects of GAHE Application on Annual Changes in Microclimate Parameters in Equine Facilities
In this manuscript, an analysis of the prospect of using a direct-contact air, gravel, ground heat exchanger (GAHE)—patented and tested at the Wroclaw University of Science and Technology—as a simple and inexpensive way of improving microclimate parameters in horse stables using renewable energy was presented. Different options for introducing a GAHE into the typical HVAC system have been proposed and examined. Using the GAHE calculation model developed based on the research, computer simulations of the GAHE’s interaction with the ventilation system were conducted. The effects of GAHE interaction were compared with a typical solution that does not utilise ground renewable energy. The analyses demonstrate year-round changes in microclimate parameters, particularly in the air temperature, relative humidity, and the THI comfort index. The benefits of using a GAHE as a component that improves comfort for animals and employees, while simultaneously saving energy, were demonstrated. The use of measurement data and computer energy simulations demonstrates the engineering feasibility of including GAHEs in a mechanical ventilation system for a horse stable. The obtained results indicate the potential for improving animal husbandry and employee working conditions without the need to consume additional energy to operate complex HVAC systems.
Open AccessEffects of GAHE Application on Annual Changes in Microclimate Parameters in Equine Facilities
In this manuscript, an analysis of the prospect of using a direct-contact air, gravel, ground heat exchanger (GAHE)—patented and tested at the Wroclaw University of Science and Technology—as a simple and inexpensive way of improving microclimate parameters in horse stables using renewable energy was presented. Different options for introducing a GAHE into the typical HVAC system have been proposed and examined. Using the GAHE calculation model developed based on the research, computer simulations of the GAHE’s interaction with the ventilation system were conducted. The effects of GAHE interaction were compared with a typical solution that does not utilise ground renewable energy. The analyses demonstrate year-round changes in microclimate parameters, particularly in the air temperature, relative humidity, and the THI comfort index. The benefits of using a GAHE as a component that improves comfort for animals and employees, while simultaneously saving energy, were demonstrated. The use of measurement data and computer energy simulations demonstrates the engineering feasibility of including GAHEs in a mechanical ventilation system for a horse stable. The obtained results indicate the potential for improving animal husbandry and employee working conditions without the need to consume additional energy to operate complex HVAC systems.
- Open Access
- 7 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 12097
The Effect of Lowering Indoor Air Temperature on the Reduction in Energy Consumption and CO2 Emission in Multifamily Buildings in Poland
This article analyzes the possibility of reducing the energy consumption from building heating as a result of lowering the indoor air temperature, which is recommended as a response to the energy crisis. Various values of the set-point temperature (16–22 °C), as well as different scenarios for their changes, were assumed for analysis. Changes in clothing that were determined to maintain the same level of thermal comfort after a temperature change were determined. The associated reduction in CO2 emissions emitted into the atmosphere was determined. The effect of reducing CO2 emissions was studied depending on the type of heating source. Simulation calculations were carried out for an exemplary multifamily building. The effect of different building insulations required in Poland over the years 1964–2022 was considered. Analyses were performed for the climatic conditions of cities located in different climatic zones of Poland: Koszalin, Wroclaw, Warsaw, Bialystok, Suwalki. Depending on the scenario, the insulation standard of the building, and the variant of location, the energy reduction achieved ranges from 6.6%/K to 13.2%/K. Taking into account the type of heating source, the reduction in CO2 emissions is from 0.7 to 7.5 kgCO2/(K·m2). The reduction in temperature by 1 or 2 K can be compensated for by wearing an additional sleeveless vest (0.12 clo) or sweater (0.28 clo).
- 7 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (15) , 12097
Open AccessThe Effect of Lowering Indoor Air Temperature on the Reduction in Energy Consumption and CO2 Emission in Multifamily Buildings in Poland
This article analyzes the possibility of reducing the energy consumption from building heating as a result of lowering the indoor air temperature, which is recommended as a response to the energy crisis. Various values of the set-point temperature (16–22 °C), as well as different scenarios for their changes, were assumed for analysis. Changes in clothing that were determined to maintain the same level of thermal comfort after a temperature change were determined. The associated reduction in CO2 emissions emitted into the atmosphere was determined. The effect of reducing CO2 emissions was studied depending on the type of heating source. Simulation calculations were carried out for an exemplary multifamily building. The effect of different building insulations required in Poland over the years 1964–2022 was considered. Analyses were performed for the climatic conditions of cities located in different climatic zones of Poland: Koszalin, Wroclaw, Warsaw, Bialystok, Suwalki. Depending on the scenario, the insulation standard of the building, and the variant of location, the energy reduction achieved ranges from 6.6%/K to 13.2%/K. Taking into account the type of heating source, the reduction in CO2 emissions is from 0.7 to 7.5 kgCO2/(K·m2). The reduction in temperature by 1 or 2 K can be compensated for by wearing an additional sleeveless vest (0.12 clo) or sweater (0.28 clo).
- 4 February 2023
- Published by Elsevier in Building and Environment
- Vol. 233
Leakage in air handling units, the effects on the transmission of airborne infections
- 4 February 2023
- Published by Elsevier in Building and Environment
- Vol. 233
Leakage in air handling units, the effects on the transmission of airborne infections
- Open Access
- 1 October 2022
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 23 (10) , 25-34
Air Filtration and Sterilization in Ventilation Systems According to the New Paradigm
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the...
- 1 October 2022
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Journal of Ecological Engineering
- Vol. 23 (10) , 25-34
Open AccessAir Filtration and Sterilization in Ventilation Systems According to the New Paradigm
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the...
- Open Access
Direct-Contact Air, Gravel, Ground Heat Exchanger in Air Treatment Systems for Cowshed Air Conditioning
This paper describes the analysis of the possibility of use of the direct-contact air, gravel, ground heat exchanger (acronym GAHE), patented at the Wroclaw University of Science and Technology, as a means of improving microclimate parameters in dairy cows’ barns. Different possibilities of introducing GAHE to the standard mechanical ventilation system of cowsheds have been proposed and investigated. Based on literature data, the required air parameters in the barns of dairy cows were determined and discussed. Computer simulations were carried out and the results obtained were compared to the baseline model. Year-round changes in microclimate parameters, especially air temperature, relative humidity, and THI index were investigated. The benefits of GAHE use were indicated. The possible increase in the minimum air volume of ventilation during the winter season and the decrease in the maximum values of this parameter in the summer were presented. Indications were made of the systems where the application of GAHE could be the most beneficial. A further research path has been proposed.
Open AccessDirect-Contact Air, Gravel, Ground Heat Exchanger in Air Treatment Systems for Cowshed Air Conditioning
This paper describes the analysis of the possibility of use of the direct-contact air, gravel, ground heat exchanger (acronym GAHE), patented at the Wroclaw University of Science and Technology, as a means of improving microclimate parameters in dairy cows’ barns. Different possibilities of introducing GAHE to the standard mechanical ventilation system of cowsheds have been proposed and investigated. Based on literature data, the required air parameters in the barns of dairy cows were determined and discussed. Computer simulations were carried out and the results obtained were compared to the baseline model. Year-round changes in microclimate parameters, especially air temperature, relative humidity, and THI index were investigated. The benefits of GAHE use were indicated. The possible increase in the minimum air volume of ventilation during the winter season and the decrease in the maximum values of this parameter in the summer were presented. Indications were made of the systems where the application of GAHE could be the most beneficial. A further research path has been proposed.
- Open Access
Waste Heat Recovery by Air-to-Water Heat Pump from Exhausted Ventilating Air for Heating of Multi-Family Residential Buildings
The paper presents an analysis of the application of an air-to-water electric compressor heat pump (AWHP) for the recovery of waste heat from the exhaust air in a typical multifamily residential building and the use of this heat for space heating, as well as the impact of this solution on the building energy performance (the PPR index). Simulations were performed in TRNSYS for five locations in Poland (Koszalin, Wrocław, Lublin, Białystok, Suwałki), for various heating system parameters (80/60 °C, 75/65 °C, 70/50 °C, 55/45 °C, 35/28 °C), for various temperature limitations of heat pump operation. It was shown that the analyzed system has great potential from an energy and environmental point of view. It can provide significant benefits in terms of the energy performance of the building, depending on the system parameters. The results show that the most energy-efficient system is the one with the lowest heating system temperatures. Moreover, implementing a temperature limitation on the heat pump operation improves its efficiency, but the higher the design parameters of the heating installation and the lower the limitation, the lower the heat pump contribution, and the higher the SCOP and the PPR. The energy effect is also influenced by location, but its scale depends on the parameters of the heating system and the temperature limitation of the heat pump’s operation. It is more significant for lower heating system parameters. This system enables the possibility of further reducing the demand for nonrenewable primary energy by powering the heat pump with photovoltaic cells.
Open AccessWaste Heat Recovery by Air-to-Water Heat Pump from Exhausted Ventilating Air for Heating of Multi-Family Residential Buildings
The paper presents an analysis of the application of an air-to-water electric compressor heat pump (AWHP) for the recovery of waste heat from the exhaust air in a typical multifamily residential building and the use of this heat for space heating, as well as the impact of this solution on the building energy performance (the PPR index). Simulations were performed in TRNSYS for five locations in Poland (Koszalin, Wrocław, Lublin, Białystok, Suwałki), for various heating system parameters (80/60 °C, 75/65 °C, 70/50 °C, 55/45 °C, 35/28 °C), for various temperature limitations of heat pump operation. It was shown that the analyzed system has great potential from an energy and environmental point of view. It can provide significant benefits in terms of the energy performance of the building, depending on the system parameters. The results show that the most energy-efficient system is the one with the lowest heating system temperatures. Moreover, implementing a temperature limitation on the heat pump operation improves its efficiency, but the higher the design parameters of the heating installation and the lower the limitation, the lower the heat pump contribution, and the higher the SCOP and the PPR. The energy effect is also influenced by location, but its scale depends on the parameters of the heating system and the temperature limitation of the heat pump’s operation. It is more significant for lower heating system parameters. This system enables the possibility of further reducing the demand for nonrenewable primary energy by powering the heat pump with photovoltaic cells.
- Open Access
- 24 September 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 116, 00009
Analysis of annual energy consumption by a warehouse building
This analysis was carried out to present the distribution of energy demand for air heating, air cooling and technology equipment for a warehouse through the year. The supplied energy is used to maintain the assumed temperatures in the rooms and for the needs of technology. During the work, the calculation model of the building was prepared and imported into the calculation program. The simulation was based on the planned building parameters (partitions structure, dimensions, technology) taken from the architectural executive design. Several versions of the structure of the construction and technical equipment have been analyzed. The obtained results show differences in the formation of energy demand and indoor room conditions.
- 24 September 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 116, 00009
Open AccessAnalysis of annual energy consumption by a warehouse building
This analysis was carried out to present the distribution of energy demand for air heating, air cooling and technology equipment for a warehouse through the year. The supplied energy is used to maintain the assumed temperatures in the rooms and for the needs of technology. During the work, the calculation model of the building was prepared and imported into the calculation program. The simulation was based on the planned building parameters (partitions structure, dimensions, technology) taken from the architectural executive design. Several versions of the structure of the construction and technical equipment have been analyzed. The obtained results show differences in the formation of energy demand and indoor room conditions.
- Open Access
- 10 June 2019
- Published by EDP Sciences
- Vol. 100, 00006
Increasing the efficiency of split type air conditioners/heat pumps by using ventilating exhaust air
The article presents the possibility of using exhaust air from ventilation system to increase the efficiency (SCOP, COP, SEER and EER) of commonly used air conditioners with the function of a heat pump. These types of devices are very popular both in residential and in public buildings. The topic discussed in the article is very important, because the widespread increase of the energy efficiency of these devices significantly influences national electricity consumption. The possibility of increasing their efficiency by directing the exhaust air from the ventilation system to the heat exchanger of the air conditioner outdoor unit has been analysed. It has been shown that the use of the simple design solution described in the article allows for a significant increase of the efficiency of these devices (seasonal efficiency even up to 35% at 100% share of exhaust air), reducing the energy consumption and increasing their capacity and operation range. By increasing the share of exhaust air it is possible to ensure year-round operation of the device and even 100% coverage of heat demand.
- 10 June 2019
- Published by EDP Sciences
- Vol. 100, 00006
Open AccessIncreasing the efficiency of split type air conditioners/heat pumps by using ventilating exhaust air
The article presents the possibility of using exhaust air from ventilation system to increase the efficiency (SCOP, COP, SEER and EER) of commonly used air conditioners with the function of a heat pump. These types of devices are very popular both in residential and in public buildings. The topic discussed in the article is very important, because the widespread increase of the energy efficiency of these devices significantly influences national electricity consumption. The possibility of increasing their efficiency by directing the exhaust air from the ventilation system to the heat exchanger of the air conditioner outdoor unit has been analysed. It has been shown that the use of the simple design solution described in the article allows for a significant increase of the efficiency of these devices (seasonal efficiency even up to 35% at 100% share of exhaust air), reducing the energy consumption and increasing their capacity and operation range. By increasing the share of exhaust air it is possible to ensure year-round operation of the device and even 100% coverage of heat demand.