    Effect of replacing a wooden keel with a polymer keel in the sach foot on walking energy expenditure in transtibial prosthesis users: a pilot study in a resource-limited setting

    by Agus Setyo Nugroho, Kazuhiko Sasaki, Muhammad Nouman, Rifky Ismail

    Objective. This study aims to compare the energy expenditure of unilateral transtibial prosthesis users when using a prototype SACH foot with a polymer keel and a local SACH foot with a wood keel. Method: This study used a quasi-experimental pretest–posttest within-subject (paired) design involving 13 users of unilateral transtibial prosthesis. All participants underwent measurements using both types of prosthetic feet. Energy expenditure was measured using the Physiological Cost Index (PCI) derived from the 6-minute walk test, and heart rate was measured with the XOSS chest sensor. Normality was assessed using the Shapiro-Wilk test, and comparisons between conditions were analyzed using the Wilcoxon signed-rank test. Results. The average PCI for the local SACH foot was 0.461 ± 0.235, and for the prototype SACH foot, 0.458 ± 0.234. The Wilcoxon test showed no statistically significant difference between the two conditions (p = 0.057; p > 0.05). However, the effect size indicated a medium-to-large effect (rβ = −0.604), with a tendency toward decreased PCI with the use of polymer SACH foot prototypes. Conclusion. This study shows that a prototype SACH foot with a polymer keel has the potential to increase walking energy efficiency compared to a local SACH foot with a wooden keel, although the difference was not statistically significant. These findings make an early contribution to the development of alternative, material-based prosthetic feet that are more efficient and better suited to rehabilitation services in developing countries. Followup research with larger sample sizes and more sensitive metabolic measurement methods is needed to confirm these findings.

  • Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate

    by Pimpet Sratong-On, Onanong Sukjai, Sawanya Suwannawong, Hui Lin Foo, Kaylen Lim, Chuen Kum Lee, Kazuhiko Sasaki

    Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko

  • Open Access

    Design and Mechanical Evaluation of a Polymer Keel SACH Foot Using Finite Element Analysis and Experimental Validation

    by Agus Setyo Nugroho, Kazuhiko Sasaki, Muhammad Nouman, Rifky Ismail

    Conventional Solid Ankle Cushion Heel (SACH) foot commonly uses wooden keels, which may exhibit variability in mechanical properties and limited long-term durability. This study aimed to develop and evaluate a polymer-based keel SACH foot as a low-cost alternative with improved mechanical performance. An integrated methodology combining finite element analysis (FEA) and experimental validation was employed. Three polymer keel SACH foot configurations were designed and analyzed under loading conditions that represent heel strike, mid-stance, and terminal stance, in accordance with ISO 10328. The optimal design was subsequently fabricated and tested under static loading conditions to validate the numerical model. The models utilized ABS for the keel, HDPE for the footplate, and vulcanized rubber for the foot body. Mechanical performance was assessed through total deformation, von Mises stress, strain, and safety factor analysis. Among the three configurations, Model A demonstrated the best mechanical performance, with the lowest average deformation (20.12 mm), the lowest stress concentration (12.67 MPa), and the highest safety factor (1.59). The selected design was subsequently fabricated and validated experimentally under static loading conditions up to 1176.78 N. Experimental validation showed strong agreement with FEA predictions, with deviations below 5% across all gait phases, confirming the accuracy of the FEA model. Comparative testing against a conventional wooden-keel SACH foot revealed significantly lower deformation values for the polymer-based keel SACH foot (p < 0.05), indicating improved structural stiffness and more efficient load distribution during loading process. These findings suggest that replacing conventional wooden keels with polymer-based structures can enhance mechanical consistency and structural reliability, while maintaining manufacturability and cost-effectiveness. The proposed design offers a promising approach to developing an affordable and durable prosthetic foot, particularly for use in low- and middle-income countries

  • Appropriate compression values for the transtibial prosthesis using the AERO prosthetic liner

    by Yusuke Miyata, Yasmin Nutchamlong, Gary Guerra, Kazuhiko Sasaki

    Positive model rectification is a key factor in providing a comfortable and successful transtibial prosthetic socket fitting. This study aimed to assess whether a 4% compression value in 3- and 5-mm thickness affordable ethylene-vinyl acetate roll-on (AERO) liners yields acceptable comfort and pressure distribution for transtibial prosthetic users. Stump socks were used to adjust volume in the fitting process with a socket compressed to 4%, and pressure data were collected using 6 force-sensing resistor (FSR400) sensors placed in areas sensitive and tolerant to pressure. Peak pressure was collected from 40 steps, and pressure uniformity was calculated using the coefficient of variation in 2-min walking on the treadmill. The socket comfort score was collected after the trial. Appropriate compression values, pressure distribution, and socket comfort score were analyzed using Wilcoxon signed-rank tests, and effect size was determined using Cliff’s delta. The study found that a 4.95% compression was optimal for a 3-mm thickness liner, whereas a 4.5% compression suited a 5-mm liner better for comfort. Moreover, the study observed a small similarity in pressure distribution between liners, as indicated by Cliff's delta, with the 5-mm liner possibly providing more even pressure because of its thickness. Despite being made of the same material, liners with different thicknesses distribute pressure differently. Therefore, this study suggests that a 4% universal compression value in the affordable ethylene-vinyl acetate roll-on liner may be effective for use in a clinical setting. Future studies should include more participants to identify the appropriate compression for a variety of residual limbs.

  • Open Access

    The AERO prosthetic liner: socket pressure distribution, comfort and material composition

    by Yusuke Miyata, Kazuhiko Sasaki, Gary Guerra, Woratee Dacharux, Sirarat Chaisumritchoke

    This study aimed to evaluate the pressure distribution and comfort of transtibial prosthesis wearers using an affordable ethyl-vinyl acetate (EVA) roll-on (AERO) liner. Fifteen unilateral transtibial prosthesis users wore patella tendon bearing (PTB) sockets with a polyethylene foam (PE-lite) liner were enrolled this study. AERO liners were provided to all participants. Six force sensors were applied to the residual limb to evaluate pressure distribution during treadmill walking, and the socket comfort score (SCS) was used to evaluate comfortability. Fourier transform infrared (FT-IR) spectroscopy was performed on the EVA and PE-lite liners. Eleven participants used prefabricated AERO liners and four participants used custom-made AERO liners. The pressure distribution was analysed by the coefficient of variation (CV): PE-lite was 75.7 ± 6.0 and AERO liner 83.3 ± 4.1. Residual limb pressure was significantly decreased when using the AERO liner (p = .0007), with a large effect size (r = 0.87). Mean SCS was 7.5 ± 1.3 and 8.9 ± 1.1 for PE-lite and AERO liner respectively. Better pressure distribution and comfort were observed when the participants used the AERO liner. AERO had a greater proportion of calcium carbonate (CaCO3). These findings suggest that the AERO liner is a better off-the-shelf option for persons using traditional prosthetic sockets and liners.


  • Open Access

    EVALUATING FEASIBILITY AND DURABILITY OF THE AERO PROSTHETIC LINER IN TRANSTIBIAL PROSTHETIC USERS

    by Yusuke Miyata, Kazuhiko Sasaki, Gary Guerra, Woratee Dacharux, Pilipda Chaiwan

    BACKGROUND: The choice of prosthetic socket interface material significantly affects user comfort and satisfaction. The Affordable Ethylene-Vinyl Acetate Roll-On (AERO) liner was created with the aim of improving functionality and streamlining the wearing process for users. OBJECTIVE: The purpose of this study was to comprehensively assess user satisfaction, comfort, and durability of the AERO liner and compare it with the common soft Pe-Lite liner. METHODOLOGY: Fourteen individuals with transtibial amputation participated in this three-month randomized crossover trial study. The Prosthesis Evaluation Questionnaire (PEQ), Expanded Socket Comfort Score (ESCS), and liner thickness measurements were used to comprehensively compare the AERO and Pe-Lite liner. FINDINGS: The AERO liner demonstrated notable improvements in prosthetic comfort and functionality over Pe-Lite liner. After three months use, there was a significant reduction in reported frustration with the AERO liner (p=0.023, r=0.604) in the PEQ subscale. Specific aspects, such as walking with the prosthesis (p=0.030, r=0.601) and odor perception (p=0.024, d=0.579), favored the use of the AERO liner. The expanded socket comfort score (ESCS) revealed significant superiority for the AERO liner “at best” (p=0.04) and “on average” (p=0.02) after one and three months, respectively. Liner thickness analysis showed significant reductions at the mid-patellar tendon location for the AERO liner at one (0.57±0.48) and three months (0.90±0.69, p=0.01) and in the posterior region after three months (0.63±0.64, p=0.05). CONCLUSION: Our study highlights the potential advantages of the AERO liner in enhancing comfort and satisfaction. Yet, durability and thinning of the liner when compared to Pe-Lite may be a concern which may eventually affect socket fit. These findings contribute to ongoing efforts to optimize prosthetic interventions and improve the quality of life of individuals with lower limb prosthesis in resource-limited environments. Layman's Abstract Comfort and satisfaction are essential for people using prosthetics. The socket interface material, which encompasses the limb, is crucial for comfort and suspension of the prosthesis on the limb. In resource-limited environments, people mainly use an interface material called Pe-Lite in their prosthetic sockets. However, there is an ongoing debate regarding its comfort and suitability for the residual limb. We aimed to evaluate an alternative material to determine if it was more comfortable and functional than Pe-Lite for these individuals. We invited fourteen people with transtibial amputations to participate in this study. They used a traditional prosthetic design and were provided both Pe-Lite and AERO liners. We asked them about their experiences and measured the various aspects of their treatment. The results were promising. People who used the AERO liner reported much less frustration after three months. They felt an improvement in walking, and they didn't have odor problems expressed when using Pe-Lite. The AERO liner was more comfortable when using the prosthesis. Although the AERO liner compressed more in certain areas compared to the Pe-Lite liner, it remained usable after three months. However, reduce the liner thickness compared to Pe-Lite may be a concern and could affect the socket fit. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/41865/32282 How To Cite: Miyata Y, Sasaki K, Guerra G, Dacharux W, Chaiwan P. Evaluating feasibility and durability of the AERO prosthetic liner in transtibial prosthetic users. Canadian Prosthetics & Orthotics Journal. 2023; Volume 6, Issue 1, No.5. https://doi.org/10.33137/cpoj.v6i1.41865 Corresponding Author: Kazuhiko Sasaki, Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. E-Mail: kazuhiko.sas@mahidol.edu ORCID ID: https://orcid.org/0000-0002-1778-6308


  • Open Access

    Evaluation of an interphalangeal-joint prosthetic hand in trans-radial prosthesis users

    by Natthawan Sutthison, Kazuhiko Sasaki, Gary Guerra, Sirarat Chaisumritchoke, Wisavaporn Niamsang, Thanatat Charatrungolan

    A body-powered functional and cosmetically appeasing hand with moving interphalangeal joints (IPJ-Hand) was created. Function and satisfaction with the IPJ-Hand, conventional hand (CH) and function...

  • Open Access

    High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet

    by Thanyaporn Rakbangboon, Gary Guerra, Saloottra Kla-Arsa, Uthumporn Padungjaroen, Pairat Tangpornprasert, Chanyaphan Virulsri, Kazuhiko Sasaki

    Outcomes of users provided with a commercial ESR Vari-Flex foot (Össur, Reykjavik, Iceland) and a locally designed sPace foot were investigated. Step activity with users’ own prosthetic foot compared to the sPace foot was explored. Methods: Eleven individuals with unilateral trans-tibial amputation participated and were provided with an sPace and Vari-Flex foot. Ten- and twenty-meter walk tests (10/20MWT) at comfortable and fast walking speeds (CWS/FWS), the two-minute walk test (2-MWT) and Comprehensive High-Level Activity Mobility Predictor (CHAMP) were administered. A subgroup was provided a pedometer to record their steps over a 7-day period in their own foot and later the sPace. Results: The sPace foot performed well in a battery of high-level mobility outcome measures. On CHAMP, participants scored 16.94 ± 5.41 and 16.72 ± 6.09 with the sPace and Vari-Flex feet, respectively. Subgroup testing of step activity showed 4490 ± 3444 steps in users’ own feet and 3115 ± 1967 in the sPace foot, p = 0.176. Conclusions: Participants using the sPace foot were capable of performing walking, high-level mobility and activity outcome measures.


  • Open Access

    Assessment of Socket Pressure during Walking in Rapid Fit Prosthetic Sockets

    by Kazuhiko Sasaki, Gary Guerra, Win Lei Phyu, Sirarat Chaisumritchoke, Prawina Sutdet, Sirintip Kaewtip

    (1) Background: A sustainable casting system that combines the use of a polystyrene bag, a prosthetic liner and a vacuum system was developed to reduce fabrication time while maintaining comfort for the trans-tibial prosthesis user. (2) Methods: Eight prosthetists (28.7 ± 8.25 years old) fit ten trans-tibial prosthesis wearers (46 ± 12.4 years old) with two types of total surface bearing (TSB) prostheses; a polystyrene bead (PS) prosthesis and a plaster of paris (POP) prosthesis. Duration of casting and combined mean peak pressure was measured at six locations on the residual limb using Force Sensing Resistors (FSR). A pressure uniformity score (%) was determined. Socket Comfort Scale (SCS) was also measured. (3) Results: Duration of casting for the POP method was 64.8 ± 9.53 min and 7.8 ± 2 min for the PS method, (p = 0.006). Pressure uniformity in the POP prosthesis was 79.3 ± 6.54 and 81.7 ± 5.83 in the PS prosthesis (p = 0.027). SCS in both prosthesis types were equivalent. (4) Conclusion: A rapid fit PS prosthesis was developed, with significantly shorter duration than the traditional POP method. Socket pressure uniformity was confirmed and improved in the PS method. Socket comfort was equal between the two prothesis types.


  • Sustainable, affordable and functional: reimagining prosthetic liners in resource limited environments

    by Yusuke Miyata, Kazuhiko Sasaki, Gary Guerra, Jutima Rattanakoch

    Purpose The purpose of this study was to evaluate function and performance of unilateral trans-tibial prosthesis users wearing an affordable liner in three types of socket designs. Methods Five unilateral trans-tibial amputees participated, were provided an Affordable Ethyl-Vinyl-Acetate Roll-On liner (AERO) roll-on liner with patella tendon bearing (PTB) prosthesis, PE-Lite liner with PTB prosthesis, and an (AERO) liner with total-surface bearing (TSB) prosthesis. A battery of outcome measures; step-counts, socket comfort score (SCS), orthotics prosthetics user survey (OPUS) and socket pressure measurement during walking were administered. Results Comparisons of step-counts indicated that PTB-AERO (3604 +/- 815) was not significantly different than PTB-PE-Lite (3386 +/- 942). Mean SCS was 9.2 +/- .83 and 7.2 +/- 2.1 for PTB-AERO and PTB-PE-Lite. A 6.6% decrease in mean peak pressure was observed between PTB-PE-Lite and TSB-AERO, and 3.2% difference between PTB-PE-Lite and PTB-AERO. Conclusion An affordable ($20 USD) and sustainably fabricated prosthesis liner was created and evaluated in trans-tibial prosthesis users. These initial results garner preliminary support for use of the AERO prosthetic liner and continued research.