Anna Lorenzin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anna Lorenzin has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Ronco
International Renal Research Institute of Vicenza (IRRIV), Vicenza, Italy
5 shared publications - Francesco Garzotto
Department of Nephrology, Dialysis and Transplantation San Bortolo Hospital
4 shared publications Massimo de Cal
4 shared publications- Silvia De Rosa
Centre for Medical Sciences, University of Trento, Trento, Italy
4 shared publications Claudio Ronco
3 shared publicationsMauro Neri
International Renal Research Institute of Vicenza, Vicenza, Italy
3 shared publications
Latest Publications
- 26 July 2024
- Published by S. Karger AG in Blood Purification
- Vol. 53 (10) , 773-780
Human Proenkephalin A 119-159 (penKid) in Extracorporeal Therapies: Ex vivo Sieving Coefficient, Diffusive Clearance, and Hemoadsorption Kinetics
Introduction: Enkephalins, endogenous opioid peptides, are involved in the regulation of renal function. One derived molecule, proenkephalin A, also known as penKid, has been demonstrated to be a reliable biomarker for kidney function and its plasma concentration correlates with measured glomerular filtration rate. penKid is used for prediction and diagnosis of AKI and need of renal replacement therapy (RRT). penKid has also been used to predict the successful weaning from RRT in patients with AKI. Whether the concentration of penKid is affected or not by RRT is a controversial point and there are no studies describing the kinetics of the molecule in such conditions. The low molecular weight (4.5 kDa) would imply free removal by the glomerulus and the dialysis membranes. During RRT, this reduction could not be detected in clinical practice due to the complex kinetics involving either low dialytic clearance or increased production in response to impaired kidney function. The aim of this study was to determine the sieving coefficient and the diffusive clearance of the penKid molecule in conditions of in vitro continuous veno-venous hemofiltration (CVVH) and continuous veno-venous hemodialysis (CVVHD), respectively, and also the penKid removal ratio in conditions of in vitro hemoadsorption (HA) using a synthetic microporous resin. Methods: Blood spiked with a lyophilized penKid peptide solved in 20 mm dipotassium phosphate and 6 mm disodium EDTA [pH 8] to reach target concentrations is used as testing solution. In each experiment, the blood batch was adjusted at a volume of 1,000 mL, maintained at 37°, and continuously stirred. Samples were collected from blood, ultrafiltrate, and spent dialysate at different times during the experiments. Sieving, clearance, and removal ratio were calculated. Results: Significant removal of penKid was observed in CVVH (sieving 1.04 ± 0.27), in CVVHD (clearance 23.08 ± 0.89), and in HA (removal ratio 76.1 ± 1% after 120 min). Conclusion: penKid is effectively removed by extracorporeal therapies. In presence of anuria, penKid generation kinetics can be calculated based on extracorporeal removal and volume variation. In steady state conditions, declining values may be the result of an initial renal function recovery and may suggest discontinuation and successful liberation from RRT.
- 26 July 2024
- Published by S. Karger AG in Blood Purification
- Vol. 53 (10) , 773-780
Human Proenkephalin A 119-159 (penKid) in Extracorporeal Therapies: Ex vivo Sieving Coefficient, Diffusive Clearance, and Hemoadsorption Kinetics
Introduction: Enkephalins, endogenous opioid peptides, are involved in the regulation of renal function. One derived molecule, proenkephalin A, also known as penKid, has been demonstrated to be a reliable biomarker for kidney function and its plasma concentration correlates with measured glomerular filtration rate. penKid is used for prediction and diagnosis of AKI and need of renal replacement therapy (RRT). penKid has also been used to predict the successful weaning from RRT in patients with AKI. Whether the concentration of penKid is affected or not by RRT is a controversial point and there are no studies describing the kinetics of the molecule in such conditions. The low molecular weight (4.5 kDa) would imply free removal by the glomerulus and the dialysis membranes. During RRT, this reduction could not be detected in clinical practice due to the complex kinetics involving either low dialytic clearance or increased production in response to impaired kidney function. The aim of this study was to determine the sieving coefficient and the diffusive clearance of the penKid molecule in conditions of in vitro continuous veno-venous hemofiltration (CVVH) and continuous veno-venous hemodialysis (CVVHD), respectively, and also the penKid removal ratio in conditions of in vitro hemoadsorption (HA) using a synthetic microporous resin. Methods: Blood spiked with a lyophilized penKid peptide solved in 20 mm dipotassium phosphate and 6 mm disodium EDTA [pH 8] to reach target concentrations is used as testing solution. In each experiment, the blood batch was adjusted at a volume of 1,000 mL, maintained at 37°, and continuously stirred. Samples were collected from blood, ultrafiltrate, and spent dialysate at different times during the experiments. Sieving, clearance, and removal ratio were calculated. Results: Significant removal of penKid was observed in CVVH (sieving 1.04 ± 0.27), in CVVHD (clearance 23.08 ± 0.89), and in HA (removal ratio 76.1 ± 1% after 120 min). Conclusion: penKid is effectively removed by extracorporeal therapies. In presence of anuria, penKid generation kinetics can be calculated based on extracorporeal removal and volume variation. In steady state conditions, declining values may be the result of an initial renal function recovery and may suggest discontinuation and successful liberation from RRT.
- Open Access
- 12 September 2022
- Published by S. Karger AG in Blood Purification
- Vol. 52 (2) , 174-182
Vancomycin Adsorption during in vitro Model of Hemoperfusion with Mini-Module of HA380 Cartridge
Introduction: Sepsis is a frequent complication in critically ill patients. Patients may require control of the source of infection, removal of pathogens and damaged cells, and organ support. Often, these targets can be achieved through the utilization of extracorporeal therapies including hemoperfusion for the adsorption of cytokines and other circulating mediators. On extracorporeal organ support, patients are generally treated with antibiotic therapy, and vancomycin is one of the most commonly used antibiotics. Because of the aspecific nature of adsorption, antibiotics can be removed from the circulation, leading to altered plasma levels and requiring prescription adjustment. The aim was to define the amount of vancomycin adsorbed by a sorbent cartridge (HA380, Jafron, China) during hemoperfusion and to establish possible strategies to maintain an effective plasma level in critically ill patients undergoing extracorporeal therapies. Methods: In vitro experiments with incremental concentrations of vancomycin in the test solution (500 and 1,000 mL) were carried out in a recirculation circuit until sorbent saturation was observed. A maximum of 10 g of vancomycin were injected and mini-modules containing 25 g of dry resin were utilized. Results: In different experiments with various concentration of vancomycin, a maximum amount of 244 mg/g of sorbent was adsorbed reaching saturation between 60 and 80 min from the beginning of the experiments. The kinetics of adsorption appears to be governed by a Langmuir-like isotherm with maximal removal speed in the early minutes and a plateau after 60 min. Discussion/Conclusion: HA380 adsorbs significant amounts of vancomycin. Adjusting the achieved results with the experimental mini-module to a full-scale cartridge, a total of 25 g of antibiotic can be removed. This might have affected outcome results in clinical trials. This suggests prescribing administration to critically ill patients requiring hemoperfusion, immediately after or in the inter-session time window. In case of administration during hemoperfusion, adequate adjustment and plasma level monitoring is strongly recommended.
- 12 September 2022
- Published by S. Karger AG in Blood Purification
- Vol. 52 (2) , 174-182
Open AccessVancomycin Adsorption during in vitro Model of Hemoperfusion with Mini-Module of HA380 Cartridge
Introduction: Sepsis is a frequent complication in critically ill patients. Patients may require control of the source of infection, removal of pathogens and damaged cells, and organ support. Often, these targets can be achieved through the utilization of extracorporeal therapies including hemoperfusion for the adsorption of cytokines and other circulating mediators. On extracorporeal organ support, patients are generally treated with antibiotic therapy, and vancomycin is one of the most commonly used antibiotics. Because of the aspecific nature of adsorption, antibiotics can be removed from the circulation, leading to altered plasma levels and requiring prescription adjustment. The aim was to define the amount of vancomycin adsorbed by a sorbent cartridge (HA380, Jafron, China) during hemoperfusion and to establish possible strategies to maintain an effective plasma level in critically ill patients undergoing extracorporeal therapies. Methods: In vitro experiments with incremental concentrations of vancomycin in the test solution (500 and 1,000 mL) were carried out in a recirculation circuit until sorbent saturation was observed. A maximum of 10 g of vancomycin were injected and mini-modules containing 25 g of dry resin were utilized. Results: In different experiments with various concentration of vancomycin, a maximum amount of 244 mg/g of sorbent was adsorbed reaching saturation between 60 and 80 min from the beginning of the experiments. The kinetics of adsorption appears to be governed by a Langmuir-like isotherm with maximal removal speed in the early minutes and a plateau after 60 min. Discussion/Conclusion: HA380 adsorbs significant amounts of vancomycin. Adjusting the achieved results with the experimental mini-module to a full-scale cartridge, a total of 25 g of antibiotic can be removed. This might have affected outcome results in clinical trials. This suggests prescribing administration to critically ill patients requiring hemoperfusion, immediately after or in the inter-session time window. In case of administration during hemoperfusion, adequate adjustment and plasma level monitoring is strongly recommended.
- 25 May 2021
- Published by S. Karger AG in Blood Purification
- Vol. 51 (2) , 138-146
Flow Dynamic Analysis by Contrast-Enhanced Imaging Techniques of Medium Cutoff Membrane Hemodialyzer
Introduction: Medium cutoff (MCO) membranes represent an interesting innovation in the field of hemodialysis. Given the correlation between large (PM >25 kDa) middle molecules (LMM) and clinical outcomes, the possibility to broaden the spectrum of solutes removed in hemodialysis with MCO membranes introduces a new perspective for end-stage kidney disease patients. Due to low diffusion coefficients of LMM, the use of convection is required to maximize extracorporeal clearance. High convective rates are achieved with high-flux membranes in hemodiafiltration, a technique not available in the US. In case of the MCO membrane, remarkable clearances of LMM are achieved combining the permeability of the membrane with a significant amount of internal convection. The mechanism of filtration-backfiltration inside the dialyzer enables effective removal of LMM in a technique called expanded hemodialysis (HDx). Given such theoretical explanation, it is important to demonstrate the blood and ultrafiltration rheology inside the MCO dialyzer. Method: This study for the first time describes flow dynamic parameters and internal cross-filtration, thanks to specific radiology and nuclear imaging techniques. Results: Flow dynamic analysis of the blood and dialysate compartment confirms excellent distribution of velocities and an excellent matching of blood and dialysate. Average blood flow velocity allows for wall shear rates adequate to avoid protein stagnation at the blood membrane interface and increase in blood viscosity. Cross-filtration analysis demonstrates a remarkable filtration/backfiltration flux reaching values >30 mL/min at a blood flow of 300 mL/min and zero net filtration. Conclusion: The MCO dialyzer Theranova 400 appears to have a design optimized to perform expanded hemodialysis (HDx).
- 25 May 2021
- Published by S. Karger AG in Blood Purification
- Vol. 51 (2) , 138-146
Flow Dynamic Analysis by Contrast-Enhanced Imaging Techniques of Medium Cutoff Membrane Hemodialyzer
Introduction: Medium cutoff (MCO) membranes represent an interesting innovation in the field of hemodialysis. Given the correlation between large (PM >25 kDa) middle molecules (LMM) and clinical outcomes, the possibility to broaden the spectrum of solutes removed in hemodialysis with MCO membranes introduces a new perspective for end-stage kidney disease patients. Due to low diffusion coefficients of LMM, the use of convection is required to maximize extracorporeal clearance. High convective rates are achieved with high-flux membranes in hemodiafiltration, a technique not available in the US. In case of the MCO membrane, remarkable clearances of LMM are achieved combining the permeability of the membrane with a significant amount of internal convection. The mechanism of filtration-backfiltration inside the dialyzer enables effective removal of LMM in a technique called expanded hemodialysis (HDx). Given such theoretical explanation, it is important to demonstrate the blood and ultrafiltration rheology inside the MCO dialyzer. Method: This study for the first time describes flow dynamic parameters and internal cross-filtration, thanks to specific radiology and nuclear imaging techniques. Results: Flow dynamic analysis of the blood and dialysate compartment confirms excellent distribution of velocities and an excellent matching of blood and dialysate. Average blood flow velocity allows for wall shear rates adequate to avoid protein stagnation at the blood membrane interface and increase in blood viscosity. Cross-filtration analysis demonstrates a remarkable filtration/backfiltration flux reaching values >30 mL/min at a blood flow of 300 mL/min and zero net filtration. Conclusion: The MCO dialyzer Theranova 400 appears to have a design optimized to perform expanded hemodialysis (HDx).
- 30 April 2019
- Published by S. Karger AG in Blood Purification
- Vol. 48 (1) , 18-24
Fluid Dynamics Analysis by CT Imaging Technique of New Sorbent Cartridges for Extracorporeal Therapies
Background: Recent innovations in biomaterials technology have led to the development of innovative sorbents adopted as adsorbing devices in the field of extracorporeal blood purification therapies. As removal mechanism, adsorption allows to remove specific molecules, selectively binding them to sorbent materials. In addition to the material properties, a quintessential aspect influencing device properties is blood flow distribution within the sorbent particles. Objectives: In order to adequately characterize the potential adsorbing properties for an effective blood purification therapy, an in vitro study assessing the fluid dynamics inside 3 new cartridges, HA130, HA230 and HA330 (Jafron, Zhuhai City, China) was conducted through CT imaging technique. Methods: The cartridges were placed in vertical position in the CT gantry. Dye solution was circulated through the cartridges at 250 mL/min, longitudinal sections, 0.5 cm thick, were recorded for 60 s. Furthermore, an in vitro test was conducted to build pressure drop profiles. Blood was circulated at a different flow rate, 100–400 mL/min, step 50 mL/min. Pre and post cartridges pressures were acquired and pressure drop calculated. Results: Sequential images demonstrated an excellent distribution of the flow inside the cartridges. Average flow velocity was 0.37 cm/s for the 3 cartridges. HA130 had a homogeneous flow profile along the entire length of the device; HA230 and HA330 showed minimal differences between central and peripheral regions. Pressure drop profiles resulted linear, increasing proportionally with blood flow rate and packing density. Conclusions: We may conclude that the structural and functional design of the studied cartridges is adequate for haemoperfusion with no channelling phenomena. This ensures maximum and optimal utilization of the sorbent contained in the devices.
- 30 April 2019
- Published by S. Karger AG in Blood Purification
- Vol. 48 (1) , 18-24
Fluid Dynamics Analysis by CT Imaging Technique of New Sorbent Cartridges for Extracorporeal Therapies
Background: Recent innovations in biomaterials technology have led to the development of innovative sorbents adopted as adsorbing devices in the field of extracorporeal blood purification therapies. As removal mechanism, adsorption allows to remove specific molecules, selectively binding them to sorbent materials. In addition to the material properties, a quintessential aspect influencing device properties is blood flow distribution within the sorbent particles. Objectives: In order to adequately characterize the potential adsorbing properties for an effective blood purification therapy, an in vitro study assessing the fluid dynamics inside 3 new cartridges, HA130, HA230 and HA330 (Jafron, Zhuhai City, China) was conducted through CT imaging technique. Methods: The cartridges were placed in vertical position in the CT gantry. Dye solution was circulated through the cartridges at 250 mL/min, longitudinal sections, 0.5 cm thick, were recorded for 60 s. Furthermore, an in vitro test was conducted to build pressure drop profiles. Blood was circulated at a different flow rate, 100–400 mL/min, step 50 mL/min. Pre and post cartridges pressures were acquired and pressure drop calculated. Results: Sequential images demonstrated an excellent distribution of the flow inside the cartridges. Average flow velocity was 0.37 cm/s for the 3 cartridges. HA130 had a homogeneous flow profile along the entire length of the device; HA230 and HA330 showed minimal differences between central and peripheral regions. Pressure drop profiles resulted linear, increasing proportionally with blood flow rate and packing density. Conclusions: We may conclude that the structural and functional design of the studied cartridges is adequate for haemoperfusion with no channelling phenomena. This ensures maximum and optimal utilization of the sorbent contained in the devices.
- Open Access
- 29 May 2017
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 40 (5) , 234-239
Prospective, Randomized, Multicenter, Controlled Trial (TRIATHRON 1) on a New Antithrombogenic Hydrophilic Dialysis Membrane
Introduction: Hemodialysis treatment requires anticoagulation to prevent thrombosis of the dialyzer. The Hydrolink® (NV series; Toray) has been designed to reduce thrombotic complications by increasing membrane hydrophilic properties. Previous studies have confirmed reduced platelet activation, improved removal of β2-microglobulin and excellent small-solute removal. Methods: We designed a prospective, multi-centered, randomized clinical study to compare the antithrombogenic effects (platelet count) of NV dialyzers versus conventional treatment. To compare the possibility of performing heparin-free dialysis, we carried out progressive heparin reduction tests. Patients with an average platelet count lower than 170,000 cells/mm3 using standard high flux membranes in the 6 months prior to the study were enrolled and randomized. Patients were either dialyzed for 6 months without changing the previous membrane (control group) or treated with the Hydrolink® membrane (NV group). After the third week, the heparin reduction test was conducted for 5 weeks in order to assess the minimum amount of anticoagulant needed to safely perform a 4-hour dialysis treatment. Performance and safety were evaluated measuring platelet count and activation, middle-molecule removal rate and nutritional status. Results: We found no significant difference in platelet count, platelet activation factors β-thromboglobulin and platelet factor 4 (PF-4), between the groups. More patients in the study group reached heparin-free dialysis without clotting events during the heparin reduction test. The NV dialyzers displayed anti-thrombogenic effects as compared to conventional dialyzers. Conclusions: The NV dialyzer series is safe with no adverse events reported. Further studies are required to understand the mechanisms of anti-thrombogenic effects.
- 29 May 2017
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 40 (5) , 234-239
Open AccessProspective, Randomized, Multicenter, Controlled Trial (TRIATHRON 1) on a New Antithrombogenic Hydrophilic Dialysis Membrane
Introduction: Hemodialysis treatment requires anticoagulation to prevent thrombosis of the dialyzer. The Hydrolink® (NV series; Toray) has been designed to reduce thrombotic complications by increasing membrane hydrophilic properties. Previous studies have confirmed reduced platelet activation, improved removal of β2-microglobulin and excellent small-solute removal. Methods: We designed a prospective, multi-centered, randomized clinical study to compare the antithrombogenic effects (platelet count) of NV dialyzers versus conventional treatment. To compare the possibility of performing heparin-free dialysis, we carried out progressive heparin reduction tests. Patients with an average platelet count lower than 170,000 cells/mm3 using standard high flux membranes in the 6 months prior to the study were enrolled and randomized. Patients were either dialyzed for 6 months without changing the previous membrane (control group) or treated with the Hydrolink® membrane (NV group). After the third week, the heparin reduction test was conducted for 5 weeks in order to assess the minimum amount of anticoagulant needed to safely perform a 4-hour dialysis treatment. Performance and safety were evaluated measuring platelet count and activation, middle-molecule removal rate and nutritional status. Results: We found no significant difference in platelet count, platelet activation factors β-thromboglobulin and platelet factor 4 (PF-4), between the groups. More patients in the study group reached heparin-free dialysis without clotting events during the heparin reduction test. The NV dialyzers displayed anti-thrombogenic effects as compared to conventional dialyzers. Conclusions: The NV dialyzer series is safe with no adverse events reported. Further studies are required to understand the mechanisms of anti-thrombogenic effects.
- Open Access
- 10 October 2016
- Published by Springer Nature in Critical Care
- Vol. 20 (1) , 1-11
Nomenclature for renal replacement therapy and blood purification techniques in critically ill patients: practical applications
This article reports the conclusions of the second part of a consensus expert conference on the nomenclature of renal replacement therapy (RRT) techniques currently utilized to manage acute kidney injury and other organ dysfunction syndromes in critically ill patients. A multidisciplinary approach was taken to achieve harmonization of definitions, components, techniques, and operations of the extracorporeal therapies. The article describes the RRT techniques in detail with the relevant technology, procedures, and phases of treatment and key aspects of volume management/fluid balance in critically ill patients. In addition, the article describes recent developments in other extracorporeal therapies, including therapeutic plasma exchange, multiple organ support therapy, liver support, lung support, and blood purification in sepsis. This is a consensus report on nomenclature harmonization in extracorporeal blood purification therapies, such as hemofiltration, plasma exchange, multiple organ support therapies, and blood purification in sepsis.
- 10 October 2016
- Published by Springer Nature in Critical Care
- Vol. 20 (1) , 1-11
Open AccessNomenclature for renal replacement therapy and blood purification techniques in critically ill patients: practical applications
This article reports the conclusions of the second part of a consensus expert conference on the nomenclature of renal replacement therapy (RRT) techniques currently utilized to manage acute kidney injury and other organ dysfunction syndromes in critically ill patients. A multidisciplinary approach was taken to achieve harmonization of definitions, components, techniques, and operations of the extracorporeal therapies. The article describes the RRT techniques in detail with the relevant technology, procedures, and phases of treatment and key aspects of volume management/fluid balance in critically ill patients. In addition, the article describes recent developments in other extracorporeal therapies, including therapeutic plasma exchange, multiple organ support therapy, liver support, lung support, and blood purification in sepsis. This is a consensus report on nomenclature harmonization in extracorporeal blood purification therapies, such as hemofiltration, plasma exchange, multiple organ support therapies, and blood purification in sepsis.
- Open Access
- 21 May 2015
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 30 (suppl_3) , iii229-iii230
FP474THE DOREMIFA (DOSE RESPONSE MULTICENTER INVESTIGATION ON FLUID ASSESSMENT) TRIAL: FILTER AND CIRCUIT LIFESPAN IN CRRT
Introduction and Aims: Acute Kidney Injury (AKI) requiring Renal Replacement Therapy (RRT) occurs in 5 to 6% of critically ill patients and is associated with high mortality and significant health resource utilization.
- 21 May 2015
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 30 (suppl_3) , iii229-iii230
Open AccessFP474THE DOREMIFA (DOSE RESPONSE MULTICENTER INVESTIGATION ON FLUID ASSESSMENT) TRIAL: FILTER AND CIRCUIT LIFESPAN IN CRRT
Introduction and Aims: Acute Kidney Injury (AKI) requiring Renal Replacement Therapy (RRT) occurs in 5 to 6% of critically ill patients and is associated with high mortality and significant health resource utilization.