Lars Müller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lars Müller has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra Constantin
Tandem Diabetes Care, Data Science, San Diego, California, USA
1 shared publication - David Nurkse
School of Medicine, UCSD, San Diego, CA, USA
1 shared publication - Dustin Wailes
School of Medicine, UCSD, San Diego, CA, USA
1 shared publication Eliah Aronoff-Spencer
University of California, San Diego
1 shared publication- Eliah Aronoff-Spencer
Division of Infectious Diseases and Global Public Health, University of California San Diego
1 shared publication - Greg Bernstein
School of Medicine, UCSD, San Diego, CA, USA
1 shared publication
Latest Publications
- Open Access
- 28 January 2021
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 23 (2) , 120-127
Real-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Background: The t:slim X2™ insulin pump with Control-IQ™ technology, an advanced hybrid closed-loop system, became available in the United States in early 2020. Real-world outcomes with use of this system have not yet been comprehensively reported. Methods: Individuals with type 1 diabetes (T1D) (≥14 years of age) who had ≥21 days of pump usage data were invited via email to participate. Participants completed psychosocial questionnaires (Technology Acceptance Scale [TAS], well-being index [WHO-5], and Diabetes Impact and Devices Satisfaction [DIDS] scale) at timepoint 1 (T1) (at least 3 weeks after starting Control-IQ technology) and the DIDS and WHO-5 at timepoint 2 (T2) (4 weeks from T1). Patient-reported outcomes (PROs) and glycemic outcomes were reviewed at each timepoint. Results: Overall, 9,085 potentially eligible individuals received the study invite. Of these, 3,116 consented and subsequently 1,435 participants completed questionnaires at both T1 and T2 and had corresponding glycemic data available on the t:connect ® web application. Time in range was 78.2% (70.2%–85.1%) at T1 and 79.2% (70.3%–86.2%) at T2. PROs reflected high device-related satisfaction and reduced diabetes impact at T2. Factors contributing to high trust in the system included sensor accuracy, improved diabetes control, reduction in extreme blood glucose levels, and improved sleep quality. In addition, participants reported improved quality of life, ease of use, and efficient connectivity to the continuous glucose monitoring system as being valuable features of the system. Conclusions: Continued real-world use of the t:slim X2 pump with Control-IQ technology showed improvements in psychosocial outcomes and persistent achievement of recommended TIR glycemic outcomes in people with T1D.
- 28 January 2021
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 23 (2) , 120-127
Open AccessReal-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Background: The t:slim X2™ insulin pump with Control-IQ™ technology, an advanced hybrid closed-loop system, became available in the United States in early 2020. Real-world outcomes with use of this system have not yet been comprehensively reported. Methods: Individuals with type 1 diabetes (T1D) (≥14 years of age) who had ≥21 days of pump usage data were invited via email to participate. Participants completed psychosocial questionnaires (Technology Acceptance Scale [TAS], well-being index [WHO-5], and Diabetes Impact and Devices Satisfaction [DIDS] scale) at timepoint 1 (T1) (at least 3 weeks after starting Control-IQ technology) and the DIDS and WHO-5 at timepoint 2 (T2) (4 weeks from T1). Patient-reported outcomes (PROs) and glycemic outcomes were reviewed at each timepoint. Results: Overall, 9,085 potentially eligible individuals received the study invite. Of these, 3,116 consented and subsequently 1,435 participants completed questionnaires at both T1 and T2 and had corresponding glycemic data available on the t:connect ® web application. Time in range was 78.2% (70.2%–85.1%) at T1 and 79.2% (70.3%–86.2%) at T2. PROs reflected high device-related satisfaction and reduced diabetes impact at T2. Factors contributing to high trust in the system included sensor accuracy, improved diabetes control, reduction in extreme blood glucose levels, and improved sleep quality. In addition, participants reported improved quality of life, ease of use, and efficient connectivity to the continuous glucose monitoring system as being valuable features of the system. Conclusions: Continued real-world use of the t:slim X2 pump with Control-IQ technology showed improvements in psychosocial outcomes and persistent achievement of recommended TIR glycemic outcomes in people with T1D.
- Open Access
- 27 April 2019
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 19 (1) , 1-7
An open access medical knowledge base for community driven diagnostic decision support system development
While early diagnostic decision support systems were built around knowledge bases, more recent systems employ machine learning to consume large amounts of health data. We argue curated knowledge bases will remain an important component of future diagnostic decision support systems by providing ground truth and facilitating explainable human-computer interaction, but that prototype development is hampered by the lack of freely available computable knowledge bases. We constructed an open access knowledge base and evaluated its potential in the context of a prototype decision support system. We developed a modified set-covering algorithm to benchmark the performance of our knowledge base compared to existing platforms. Testing was based on case reports from selected literature and medical student preparatory material. The knowledge base contains over 2000 ICD-10 coded diseases and 450 RX-Norm coded medications, with over 8000 unique observations encoded as SNOMED or LOINC semantic terms. Using 117 medical cases, we found the accuracy of the knowledge base and test algorithm to be comparable to established diagnostic tools such as Isabel and DXplain. Our prototype, as well as DXplain, showed the correct answer as “best suggestion” in 33% of the cases. While we identified shortcomings during development and evaluation, we found the knowledge base to be a promising platform for decision support systems. We built and successfully evaluated an open access knowledge base to facilitate the development of new medical diagnostic assistants. This knowledge base can be expanded and curated by users and serve as a starting point to facilitate new technology development and system improvement in many contexts.
- 27 April 2019
- Published by Springer Nature in BMC Medical Informatics and Decision Making
- Vol. 19 (1) , 1-7
Open AccessAn open access medical knowledge base for community driven diagnostic decision support system development
While early diagnostic decision support systems were built around knowledge bases, more recent systems employ machine learning to consume large amounts of health data. We argue curated knowledge bases will remain an important component of future diagnostic decision support systems by providing ground truth and facilitating explainable human-computer interaction, but that prototype development is hampered by the lack of freely available computable knowledge bases. We constructed an open access knowledge base and evaluated its potential in the context of a prototype decision support system. We developed a modified set-covering algorithm to benchmark the performance of our knowledge base compared to existing platforms. Testing was based on case reports from selected literature and medical student preparatory material. The knowledge base contains over 2000 ICD-10 coded diseases and 450 RX-Norm coded medications, with over 8000 unique observations encoded as SNOMED or LOINC semantic terms. Using 117 medical cases, we found the accuracy of the knowledge base and test algorithm to be comparable to established diagnostic tools such as Isabel and DXplain. Our prototype, as well as DXplain, showed the correct answer as “best suggestion” in 33% of the cases. While we identified shortcomings during development and evaluation, we found the knowledge base to be a promising platform for decision support systems. We built and successfully evaluated an open access knowledge base to facilitate the development of new medical diagnostic assistants. This knowledge base can be expanded and curated by users and serve as a starting point to facilitate new technology development and system improvement in many contexts.
- 18 June 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 406-414
DesignX in the Emergency Department: Requirements of a Digital Antibiogram
- 18 June 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 406-414
DesignX in the Emergency Department: Requirements of a Digital Antibiogram