Latest Publications

  • Open Access

    Lead-Free Ceramics in Prestressed Ultrasonic Transducers

    by Claus Scheidemann, Peter Bornmann, Walter Littmann, Tobias Hemsel

    Today’s ultrasonic transducers find broad application in diverse technology branches and most often cannot be replaced by other actuators. They are typically based on lead-containing piezoelectric ceramics. These should be replaced for environmental and health issues by lead-free alternatives. Multiple material alternatives are already known, but there is a lack of information about their technological readiness level. To fill this gap, a small series of prestressed longitudinally vibrating transducers was set up with a standard PZT material and two lead-free variants within this study. The entire process for building the transducers is documented: characteristics of individual ring ceramics, burn-in results, and free vibration and characteristics under load are shown. The main result is that the investigated lead-free materials are ready to use within ultrasonic bolted Langevin transducers (BLTs) for medium-power applications, when the geometrical setup of the transducer is adopted. Since lead-free ceramics need higher voltages to achieve the same power level, the driving electronics or the mechanical setup must be altered specifically for each material. Lower self-heating of the lead-free materials might be attractive for heat-sensitive processes.


  • Open Access

    Lead-Free Ceramics in Prestressed Ultrasonic Transducers

    by Claus Scheidemann, Peter Bornmann, Walter Littmann, Tobias Hemsel

    Todays ultrasonic transducers find broad application in diverse technology branches and most often cannot be replaced by other actuators. They are typically based on lead containing piezoelectric ceramics. These should be replaced for environmental and health issues by lead-free alternatives. Multiple material alternatives are already known, but there is a lack of information about their technological readiness level. To fill this gap., a small series of prestressed longitudinally vibrating transducers was set up with a standard PZT material and two lead-free variants within this study. The entire process for building the transducers is documented: Characteristics of individual ring ceramics, burn-in results, free vibration and characteristics under load are shown. The main result is that the investigated lead-free materials are ready to use within ultrasonic bolted Langevin transducers (BLT) for medium power applications, when the geometrical setup of the transducer is adopted. Since lead-free ceramics need higher voltages to achieve the same power level, the driving electronics or the mechanical setup must be altered specifically for each material. Lower self-heating of the lead-free materials might be attractive for heat sensitive processes.

  • Open Access

    The Influence of Ultrasonic Irradiation of a 316L Weld Pool Produced by DED on the Mechanical Properties of the Produced Component

    by Dennis Lehnert, Christian Bödger, Philipp Pabel, Claus Scheidemann, Tobias Hemsel, Stefan Gnaase, David Kostka, Thomas Tröster

    Additive manufacturing of metallic components often results in the formation of columnar grain structures aligned along the build direction. These elongated grains can introduce anisotropy, negatively impacting the mechanical properties of the components. This study aimed to achieve controlled solidification with a fine-grained microstructure to enhance the mechanical performance of printed parts. Stainless steel 316L was used as the test material. High-intensity ultrasound was applied during the direct energy deposition (DED) process to inhibit the formation of columnar grains. The investigation emphasized the importance of amplitude changes of the ultrasound wave as the system’s geometry continuously evolves with the addition of multiple layers and assessed how these changes influence the grain size and distribution. Initial tests revealed significant amplitude fluctuations during layer deposition, highlighting the impact of layer deposition on process uniformity. The mechanical results demonstrated that the application of ultrasound effectively refined the grain structure, leading to a 15% increase in tensile strength compared to conventionally additively manufactured samples.


  • Open Access

    Diagnostics of Piezoelectric Bending Actuators Subjected to Varying Operating Conditions

    by Osarenren Kennedy Aimiyekagbon, Amelie Bender, Tobias Hemsel, Walter Sextro

    In applications of piezoelectric actuators and sensors, the dependability and particularly the reliability throughout their lifetime are vital to manufacturers and end-users and are enabled through condition-monitoring approaches. Existing approaches often utilize impedance measurements over a range of frequencies or velocity measurements and require additional equipment or sensors, such as a laser Doppler vibrometer. Furthermore, the non-negligible effects of varying operating conditions are often unconsidered. To minimize the need for additional sensors while maintaining the dependability of piezoelectric bending actuators irrespective of varying operating conditions, an online diagnostics approach is proposed. To this end, time- and frequency-domain features are extracted from monitored current signals to reflect hairline crack development in bending actuators. For validation of applicability, the presented analysis method was evaluated on piezoelectric bending actuators subjected to accelerated lifetime tests at varying voltage amplitudes and under external damping conditions. In the presence of a crack and due to a diminished stiffness, the resonance frequency decreases and the root-mean-square amplitude of the current signal simultaneously abruptly drops during the lifetime tests. Furthermore, the piezoelectric crack surfaces clapping is reflected in higher harmonics of the current signal. Thus, time-domain features and harmonics of the current signals are sufficient to diagnose hairline cracks in the actuators.


  • Open Access

    Optimization of Ultrasonic Acoustic Standing Wave Systems

    by Paul Dunst, Tobias Hemsel, Peter Bornmann, Walter Littmann, Walter Sextro

    Ultrasonic acoustic standing wave systems find use in many industrial applications, such as sonochemical reactions, atomization of liquids, ultrasonic cleaning, and spray dry. In most applications, highest possible sound pressure levels are needed to achieve optimum results. Until now, the atomization of liquids is limited to fluids with low viscosity, as systems generating sufficient sound pressure for atomizing fluids with higher viscosities are often not marketable due to their low throughput or high costs. For the production of polymer or metal powders or the dispensing of adhesives, highest sound pressures should be achieved with systems in suitable size, with good efficiency and at low cost but without contamination of sonotrodes and reflectors by the dispersed media. An alternative to the use of more powerful transducers is increasing the intensity of the acoustic standing wave field by optimizing the boundary conditions of the acoustic field. In most existing standing wave systems a part of the radiating sound waves does not contribute to the process, as the waves spread into the wrong direction or wipe themselves out due to interference. In order to obtain maximum sound pressure amplitudes in the standing wave field, all waves should be trapped between the sonotrode and the reflector. In addition, the resonance condition should be met for all radiated waves. These conditions can be fulfilled by optimizing the shapes of sonotrode and resonator as well as the distance between them. This contribution reports on a model, which is able to simulate the sound field between a transducer surface and a reflector. Using a linear finite-element model, the boundary conditions of the standing wave system are optimized. Sound pressure levels of the standing wave field are calculated for different shapes of reflectors and boundary conditions like the distance between the transducer and the reflector. The simulation results are validated by sound-field measurements via refracto-vibrometry and a microphone. Finally, optimization guidelines for the generation of high-intensity acoustic standing wave fields are shown and verified by measurements.


  • Open Access

    Vibration-Assisted Handling of Dry Fine Powders

    by Paul Dunst, Peter Bornmann, Tobias Hemsel, Walter Sextro

    Since fine powders tend strongly to adhesion and agglomeration, their processing with conventional methods is difficult or impossible. Typically, in order to enable the handling of fine powders, chemicals are added to increase the flowability and reduce adhesion. This contribution shows that instead of additives also vibrations can be used to increase the flowability, to reduce adhesion and cohesion, and thus to enable or improve processes such as precision dosing, mixing, and transport of very fine powders. The methods for manipulating powder properties are described in detail and prototypes for experimental studies are presented. It is shown that the handling of fine powders can be improved by using low-frequency, high-frequency or a combination of low- and high-frequency vibration.


  • Estimation of Remaining Useful Lifetime of Piezoelectric Transducers Based on Self-Sensing

    by James Kuria Kimotho, Tobias Hemsel, Walter Sextro

    Piezoelectric transducers are used in a wide range of applications. Reliability of these transducers is an important aspect in their application. Prognostics, which involve continuous monitoring of the health of technical systems and using this information to estimate the current health state and consequently predict the remaining useful lifetime (RUL), can be used to increase the reliability, safety, and availability of the transducers. This is achieved by utilizing the health state and RUL predictions to adaptively control the usage of the components or to schedule appropriate maintenance without interrupting operation. In this work, a prognostic approach utilizing self-sensing, where electric signals of a piezoelectric transducer are used as the condition monitoring data, is proposed. The approach involves training machine learning algorithms to model the degradation of the transducers through a health index and the use of the learned model to estimate the health index of similar transducers. The current health index is then used to estimate RUL of test components. The feasibility of the approach is demonstrated using piezoelectric bimorphs and the results show that the method is accurate in predicting the health index and RUL.


  • Kavitationsdetektion mittels Self-Sensing-Ultraschallwandler

    by Peter Bornmann, Tobias Hemsel, Walter Sextro, Gianluca Memoli, Mark Hodnett, Bajram Zeqiri

    Zusammenfassung Eine Vielzahl von Prozessen in der Chemie und Verfahrenstechnik kann durch Ultraschall positiv beeinflusst werden. Oftmals ist ultraschallinduzierte Kavitation der Hauptwirkmechanismus für die positiven Effekte der Beschallung. Daher ist es notwendig die Kavitationsaktivität während des Prozesses zu quantifizieren um die Beschallung für den jeweiligen Prozess optimal gestalten und überwachen zu können. Eine Möglichkeit der prozessbegleitenden Kavitationsdetektion ist die Auswertung der akustischen Emissionen von oszillierenden und kollabierenden Kavitationsblasen mittels Drucksensoren in der Flüssigkeit. Raue Prozessrandbedingungen wie hohe Temperaturen oder aggressive Flüssigkeiten erschweren es jedoch geeignete Sensoren zu finden. Als Alternative wurde daher die Nutzbarkeit der Rückwirkung von Kavitationsereignissen auf das elektrische Eingansgssignal des Ultraschallwandlers zur Quantifizierung von Kavitation untersucht. Die experimentelle Analyse hat ergeben, dass das Einsetzen und in einigen Fällen auch die Art der Kavitation auf Basis der Rückwirkung auf das Stromsignal des Ultraschallwandlers bestimmt werden kann. Die Stärke der Kavitation war hingegen nicht aus den Stromsignalen abzuleiten.


  • Reliability analysis of ultrasonic power transducers

    by Tobias Hemsel, Peter Bornmann, Takeshi Morita, Christoph Sondermann-Wölke, Walter Sextro