IMIda Mura

Ida Mura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ida Mura has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Air microbial sampling in operating theatres by active and passive methods: equation correlation from the GISIO-ISChIA study results and comparison with the EU GGMP recommendation, towards the definition of threshold values.

    by Cesira Isabella Maria Pasquarella, Francesco Auxilia, Martina Barchitta, Maria Luisa Cristina, Daniela D'Alessandro, Ida Mura, Marta Nobile, Licia Veronesi, Roberto Albertini, Antonella Agodi

    The aim of this study was to calculate the equation of correlation between the microbial air contamination values obtained by active sampling (colony-forming units per cubic metre, CFU/m3) and by passive sampling (Index of microbial air contamination, IMA), by using the data from the ISChIA study, and to compare the values obtained with the recommended limits defined by the EU Guidelines to Good Manufacturing Practice (EU GGMP), 2008, for clean areas used to manufacture sterile medicinal products. Air sampling was performed during 335 elective prosthesis procedures. Correlation between CFU/m3 and IMA values was evaluated using the Spearman test; p<0.05 was considered to indicate significance. This equation was used to calculate the IMA values corresponding to the CFU/m3 recommended threshold values by EU GGMP for the different Grades of microbial contamination. The following correlation equation was obtained: y = 1.86 + 0.12x, where "x" = cfu/m3 value and "y" = IMA value. The relationships between CFU/m3 and IMA values obtained from active and passive sampling during the ISChIA study showed to be in line to those suggested by the EU GGMP for pharmaceutical manufacturing for Grade C and D. This study shows that the EU GGMP relationship could be considered valid also for operating theatres. Both methods, active and passive samplings, can be used to evaluate microbial air quality and highlight critical situations; however, in particular during the activity, passive sampling estimating the risk posed by airborne microorganisms to the surgical wound, can be considered more relevant, and for its simplicity, economy and standardization, can be suggested for routine microbial monitoring.


  • Open Access

    Early Prediction of Seven-Day Mortality in Intensive Care Unit Using a Machine Learning Model: Results from the SPIN-UTI Project

    by Martina Barchitta, Andrea Maugeri, Giuliana Favara, Paolo Marco Riela, Giovanni Gallo, Ida Mura, Antonella Agodi

    Patients in intensive care units (ICUs) were at higher risk of worsen prognosis and mortality. Here, we aimed to evaluate the ability of the Simplified Acute Physiology Score (SAPS II) to predict the risk of 7-day mortality, and to test a machine learning algorithm which combines the SAPS II with additional patients’ characteristics at ICU admission. We used data from the “Italian Nosocomial Infections Surveillance in Intensive Care Units” network. Support Vector Machines (SVM) algorithm was used to classify 3782 patients according to sex, patient’s origin, type of ICU admission, non-surgical treatment for acute coronary disease, surgical intervention, SAPS II, presence of invasive devices, trauma, impaired immunity, antibiotic therapy and onset of HAI. The accuracy of SAPS II for predicting patients who died from those who did not was 69.3%, with an Area Under the Curve (AUC) of 0.678. Using the SVM algorithm, instead, we achieved an accuracy of 83.5% and AUC of 0.896. Notably, SAPS II was the variable that weighted more on the model and its removal resulted in an AUC of 0.653 and an accuracy of 68.4%. Overall, these findings suggest the present SVM model as a useful tool to early predict patients at higher risk of death at ICU admission.


  • Open Access

    Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    by Maria Teresa Montagna, Osvalda De Giglio, Maria Luisa Cristina, Christian Napoli, Claudia Pacifico, Antonella Agodi, Tatjana Baldovin, Beatrice Casini, Maria Anna Coniglio, Marcello Mario D’errico, et al.

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.


    • 27 October 2015
      • Vol. 39, 94-8

    Antibiotic consumption and resistance: results of the SPIN-UTI project of the GISIO-SItI.

    by Antonella Agodi, Francesco Auxilia, Martina Barchitta, Silvio Brusaferro, Marcello Mario D'errico, Maria Teresa Montagna, Cesira Pasquarella, Stefano Tardivo, Ida Mura

    To evaluate trends and association between antibiotic consumption and resistance during an eight-year period, from 2006 to 2013. Prospective multicenter study. Intensive Care Units (ICUs) participating in the four editions of the Italian nosocomial infections surveillance in the ICU Network (Sorveglianza Prospettica delle Infezioni Nosocomiali nelle Unità di Terapia Intensiva, SPIN-UTI project). The isolation density of selected species of microorganisms, antibiotic resistance rates (RRs), incidence density of resistant isolates and antimicrobial usage density were calculated. RRs of carbapenem-resistant Acinetobacter baumannii, of carbapenem-resistant Klebsiella pneumoniae, of third-generation cephalosporin (3GC)-resistant K. pneumoniae and of 3GC-resistant Escherichia coli showed significant increasing trends (p ≤0.001). The consumption of each antibiotic class varied with years, although not significantly. Significant strongly positive correlations were detected between RRs and antibiotic consumption. The present study describes high RRs and increasing trends of resistant microorganisms and highlights the need for continuous comprehensive strategies targeting not only the prudent use of antibiotics, but also infection control measures to limit the epidemic spread of resistant isolates.


  • Compliance with guidelines on antibiotic prophylaxis in hip and knee arthroplasty in Italy: results of the GISIO-ISChIA project.

    by Antonella Agodi, Francesco Auxilia, Martina Barchitta, Maria Luisa Cristina, Ida Mura, Marta Nobile, Cesira Pasquarella

    The Perioperative Antibiotic Prophylaxis (PAP) contributes considerably to the total amount of antibiotics used in hospitals and has been shown to be associated with increase in antibiotic resistance and healthcare costs. The level of compliance with the national guidelines of current practices of PAP for elective hip and knee prosthesis procedures in a network of Italian hospitals (the multicentre Surgical Site Infection surveillance project GISIO-ISChIA), has been evaluated. Compliance of the current prophylactic antibiotic practices with the published national guidelines was assessed for each included operative procedure, considering indication, timing of administration, prescribed antimicrobial agent and total duration of prophylaxis. A total of 14 hospitals and 1285 surgical procedures were included. 99.4% of patients received antimicrobial prophylaxis pre-operatively and 73.0% of patients received PAP within the recommended time period (within 60 minutes before incision). The rate of compliance with discontinuation of PAP within 24 hours after initiation of surgery was 70.2%. Taking into account all doses administered, the antibiotic was chosen appropriately in 57.7% of patients. PAP was performed appropriately, in accordance with national guidelines, in 43.6% of surgical operations. Given the increasing number of replacement procedures in Italy and in Europe, the gap between the evidence-based guidelines and practice must be appropriately addressed in order to improve PAP practices.


    • 12 March 2015
      • Vol. 38, 51-6

    [Control of intubator associated pneumonia in intensive care unit: results of the GISIO-SItI SPIN-UTI Project].

    by Antonella Agodi, Francesco Auxilia, Martina Barchitta, Marcello Mario D'errico, Maria Teresa Montagna, Cesira Pasquarella, Stefano Tardivo, Ida Mura

    To document reported Intubator Associated Pneumonia (IAP) prevention practices in Intensive Care Units (ICUs) and attitudes towards the implementation of a measurement system. In the framework of the SPIN-UTI project the «Italian Nosocomial Infections Surveillance in ICUs network», two questionnaires were made available online. The first was filled out by physicians working in ICUs in order to collect data on characteristics of physicians and ICUs, on clinical and measurement practices for IAP prevention, and attitudes towards the implementation of a measurement system. The second questionnaire was filled out for each intubated patient in order to collect data on prevention practices during ICU stay. ICUs participating to the fourth edition (2012-2013) of the SPIN-UTI project. Compliance to the component of the European bundle. The components of the bundle for the prevention of IAP are implemented, although to a different level, in the 26 participating ICUs. Overall compliance to all five practices of the European bundle has been reported in 21.1% of the 768 included patients. The present survey has documented a large potential for improvement in clinical and non-clinical practices aimed at preventing IAP in ICUs.


    • 12 March 2015
      • Vol. 38, 62-5

    [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    by Maria Teresa Montagna, Osvalda De Giglio, Christian Napoli, Lucia Cannova, Maria Luisa Cristina, Maria Grazia Deriu, Santi Antonino Delia, Ada Giuliano, Marco Guida, Pasqualina Laganà, et al.

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.


    • 12 March 2015
      • Vol. 38, 153-7

    [Education and training in patient safety and prevention and control of healthcare associated infections].

    by Antonella Agodi, Francesco Auxilia, Silvio Brusaferro, Roberta Chiesa, Daniela D'Alessandro, Marcello Mario D'Errico, Gianfranco Finzi, Marcello Meledandri, Maria Mongardi, Maria Teresa Montagna, et al.


  • Open Access

    Knowledge about tuberculosis among undergraduate health care students in 15 Italian universities: a cross-sectional study

    by Maria Teresa Montagna, Christian Napoli, Silvio Tafuri, Antonella Agodi, Francesco Auxilia, Beatrice Casini, Maria Franca Coscia, Marcello Mario D’errico, Margherita Ferrante, Angelo Fortunato, et al.

    The Italian Study Group on Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine and Public Health conducted a multicentre survey aiming to evaluate undergraduate health care students’ knowledge of tuberculosis and tuberculosis control measures in Italy. In October 2012–June 2013, a sample of medical and nursing students from 15 Italian universities were enrolled on a voluntary basis and asked to complete an anonymous questionnaire investigating both general knowledge of tuberculosis (aetiology, clinical presentation, outcome, screening methods) and personal experiences and practices related to tuberculosis prevention. Data were analysed through multivariable regression using Stata software. The sample consisted of 2,220 students in nursing (72.6%) and medicine (27.4%) courses. Our findings clearly showed that medical students had a better knowledge of tuberculosis than did nursing students. Although the vast majority of the sample (up to 95%) answered questions about tuberculosis aetiology correctly, only 60% of the students gave the correct responses regarding clinical aspects and vaccine details. Overall, 66.9% of the students had been screened for tuberculosis, but less than 20% of those with a negative result on the tuberculin skin test were vaccinated. Multivariable regression analysis showed that age and type of study programme (nursing vs. medical course) were determinants of answering the questions correctly. Although our data showed sufficient knowledge on tuberculosis, this survey underlines the considerable need for improvement in knowledge about the disease, especially among nursing students. In light of the scientific recommendations concerning tuberculosis knowledge among students, progress of current health care curricula aimed to develop students’ skills in this field is needed.