Julien Bellec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julien Bellec has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- C. Lafond
Southeast University, Nanjing, Jiangsu
5 shared publications M. Perdrieux
Centre Eugène Marquis, Unité de Physique Médicale et Radioprotetction, rue de La Bataille Flandres Dunkerque - CS 44229, F-35042 Rennes Cedex, France
5 shared publicationsN. Delaby
Centre Eugène Marquis, Unité de Physique Médicale et Radioprotetction, rue de La Bataille Flandres Dunkerque - CS 44229, F-35042 Rennes Cedex, France
5 shared publicationsE. Chajon
Radiotherapy Department, Centre Eugène Marquis, avenue de La Bataille Flandres Dunkerque - CS 44229, F-35042, Rennes, France
4 shared publications- F. Jouyaux4 shared publications
I. Lecouillard
4 shared publications
Latest Publications
- Open Access
- 14 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70170
Optimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume
Purpose/objective: This study proposes an implementation of the mid‐position (MidP) approach to compensate for cardio‐respiratory motions in the context of Stereotactic Arrhythmia Radioablation (STAR) and evaluates its benefits compared to an internal target volume (ITV) approach. Materials and methods: Fifteen patients who underwent STAR for refractory ventricular tachycardia in our institution were included in this retrospective planning study. For each patient, a cardiac‐gated four‐dimensional computed tomography (4D‐CT card ) scan and a respiratory‐gated four‐dimensional computed tomography (4D‐CT resp) were acquired. All patients were treated using a volumetric modulated arc therapy technique using an in‐treatment Cone‐Beam CT (CBCT) image guidance. The MidP approach was implemented to compensate for uncertainties, including cardio‐respiratory motions characterized using the 4D‐CT card and 4D‐CT resp scans, and the inter‐fraction motions measured using the CBCT scans. For comparison purposes, the ITV approach was also implemented. Both approaches were compared in terms of planning target volume (PTV) volumes, doses to organs‐at‐risk, and clinical target volume (CTV) doses, assessed using a 4D modeling method that estimates the accumulated dose. Results: Compared with the ITV method, the MidP approach resulted in a mean [min‐max] relative PTV volume reduction of 30% [19%, 48%] ( p < 0.001, Wilcoxon signed rank test). The mean [min‐max] D95% CTV coverage was 105% [101%–114%] and 107% [101%–117%] of the prescription dose for MidP and ITV‐based plans, respectively. The median dose to the whole heart was significantly lower with MidP‐based plans with a mean difference of −0.5 Gy ( p = 0.0084). The near‐maximum dose (D1%) delivered to left coronary arteries, aorta, and stomach was systematically lower with the MidP‐based plans. Conclusion: Compared to ITV based approach, the use of MidP strategy for treatment planning of STAR leads to significantly smaller PTV and lower surrounding OAR doses while still achieving a clinically acceptable CTV coverage.
- 14 July 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (7) , e70170
Open AccessOptimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume
Purpose/objective: This study proposes an implementation of the mid‐position (MidP) approach to compensate for cardio‐respiratory motions in the context of Stereotactic Arrhythmia Radioablation (STAR) and evaluates its benefits compared to an internal target volume (ITV) approach. Materials and methods: Fifteen patients who underwent STAR for refractory ventricular tachycardia in our institution were included in this retrospective planning study. For each patient, a cardiac‐gated four‐dimensional computed tomography (4D‐CT card ) scan and a respiratory‐gated four‐dimensional computed tomography (4D‐CT resp) were acquired. All patients were treated using a volumetric modulated arc therapy technique using an in‐treatment Cone‐Beam CT (CBCT) image guidance. The MidP approach was implemented to compensate for uncertainties, including cardio‐respiratory motions characterized using the 4D‐CT card and 4D‐CT resp scans, and the inter‐fraction motions measured using the CBCT scans. For comparison purposes, the ITV approach was also implemented. Both approaches were compared in terms of planning target volume (PTV) volumes, doses to organs‐at‐risk, and clinical target volume (CTV) doses, assessed using a 4D modeling method that estimates the accumulated dose. Results: Compared with the ITV method, the MidP approach resulted in a mean [min‐max] relative PTV volume reduction of 30% [19%, 48%] ( p < 0.001, Wilcoxon signed rank test). The mean [min‐max] D95% CTV coverage was 105% [101%–114%] and 107% [101%–117%] of the prescription dose for MidP and ITV‐based plans, respectively. The median dose to the whole heart was significantly lower with MidP‐based plans with a mean difference of −0.5 Gy ( p = 0.0084). The near‐maximum dose (D1%) delivered to left coronary arteries, aorta, and stomach was systematically lower with the MidP‐based plans. Conclusion: Compared to ITV based approach, the use of MidP strategy for treatment planning of STAR leads to significantly smaller PTV and lower surrounding OAR doses while still achieving a clinically acceptable CTV coverage.
- 20 January 2022
- Published by Elsevier in Physica Medica
- Vol. 95, 16-24
Cardiac radioablation for ventricular tachycardia: Which approach for incorporating cardiorespiratory motions into the planning target volume?
- 20 January 2022
- Published by Elsevier in Physica Medica
- Vol. 95, 16-24
Cardiac radioablation for ventricular tachycardia: Which approach for incorporating cardiorespiratory motions into the planning target volume?
- 1 October 2020
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 24 (6-7) , 770
Radiothérapie ablative des tachycardies ventriculaires : impact des mouvements cardiaques et respiratoires sur la définition du volume cible
- 1 October 2020
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 24 (6-7) , 770
Radiothérapie ablative des tachycardies ventriculaires : impact des mouvements cardiaques et respiratoires sur la définition du volume cible
- Open Access
- 3 March 2020
- Published by Springer Nature in Radiation Oncology
- Vol. 15 (1) , 1-10
ITV versus mid-ventilation for treatment planning in lung SBRT: a comparison of target coverage and PTV adequacy by using in-treatment 4D cone beam CT
Background: The internal target volume (ITV) approach and the mid-ventilation (MidV) concept are the two main respiratory motion-management strategies under free breathing. The purpose of this work was to compare the actual in-treatment target coverage during volumetric modulated arctherapy (VMAT) delivered through both ITV-based and MidV-based planning target volume (PTV) and to provide knowledge in choosing the optimal PTV for stereotactic body radiotherapy (SBRT) for lung lesions. Methods and materials: Thirty-two lung cancer patients treated by a VMAT technique were included in the study. For each fraction, the mean time-weighted position of the target was localized by using a 4-dimensional cone-beam CT (4D-CBCT)-based image guidance procedure. The respiratory-correlated location of the gross tumor volume (GTV) during treatment delivery was determined for each fraction by using in-treatment 4D-CBCT images acquired concurrently with VMAT delivery (4D-CBCTin-treat). The GTV was delineated from each of the ten respiratory phase-sorted 4D-CBCTin-treat datasets for each fraction. We defined target coverage as the average percentage of the GTV included within the PTV during the patient’s breathing cycle averaged over the treatment course. Target coverage and PTVs were reported for a MidV-based PTV (PTVMidV) using dose-probabilistic margins and three ITV-based PTVs using isotropic margins of 5 mm (PTVITV + 5mm), 4 mm (PTVITV + 4mm) and 3 mm (PTVITV + 3mm). The in-treatment baseline displacements and target motion amplitudes were reported to evaluate the impact of both parameters on target coverage. Results: Overall, 100 4D-CBCTin-treat images were analyzed. The mean target coverage was 98.6, 99.6, 98.9 and 97.2% for PTVMidV, PTVITV + 5mm, PTVITV + 4mm and PTVITV + 3mm, respectively. All the PTV margins led to a target coverage per treatment higher than 95% in at least 90% of the evaluated cases. Compared to PTVITV + 5mm, PTVMidV, PTVITV + 4mm and PTVITV + 3mm had mean PTV reductions of 16, 19 and 33%, respectively. Conclusion: When implementing VMAT with 4D-CBCT-based image guidance, an ITV-based approach with a tighter margin than the commonly used 5 mm margin remains an alternative to the MidV-based approach for reducing healthy tissue exposure in lung SBRT. Compared to PTVMidV, PTVITV + 3mm significantly reduced the PTV while still maintaining an adequate in-treatment target coverage.
- 3 March 2020
- Published by Springer Nature in Radiation Oncology
- Vol. 15 (1) , 1-10
Open AccessITV versus mid-ventilation for treatment planning in lung SBRT: a comparison of target coverage and PTV adequacy by using in-treatment 4D cone beam CT
Background: The internal target volume (ITV) approach and the mid-ventilation (MidV) concept are the two main respiratory motion-management strategies under free breathing. The purpose of this work was to compare the actual in-treatment target coverage during volumetric modulated arctherapy (VMAT) delivered through both ITV-based and MidV-based planning target volume (PTV) and to provide knowledge in choosing the optimal PTV for stereotactic body radiotherapy (SBRT) for lung lesions. Methods and materials: Thirty-two lung cancer patients treated by a VMAT technique were included in the study. For each fraction, the mean time-weighted position of the target was localized by using a 4-dimensional cone-beam CT (4D-CBCT)-based image guidance procedure. The respiratory-correlated location of the gross tumor volume (GTV) during treatment delivery was determined for each fraction by using in-treatment 4D-CBCT images acquired concurrently with VMAT delivery (4D-CBCTin-treat). The GTV was delineated from each of the ten respiratory phase-sorted 4D-CBCTin-treat datasets for each fraction. We defined target coverage as the average percentage of the GTV included within the PTV during the patient’s breathing cycle averaged over the treatment course. Target coverage and PTVs were reported for a MidV-based PTV (PTVMidV) using dose-probabilistic margins and three ITV-based PTVs using isotropic margins of 5 mm (PTVITV + 5mm), 4 mm (PTVITV + 4mm) and 3 mm (PTVITV + 3mm). The in-treatment baseline displacements and target motion amplitudes were reported to evaluate the impact of both parameters on target coverage. Results: Overall, 100 4D-CBCTin-treat images were analyzed. The mean target coverage was 98.6, 99.6, 98.9 and 97.2% for PTVMidV, PTVITV + 5mm, PTVITV + 4mm and PTVITV + 3mm, respectively. All the PTV margins led to a target coverage per treatment higher than 95% in at least 90% of the evaluated cases. Compared to PTVITV + 5mm, PTVMidV, PTVITV + 4mm and PTVITV + 3mm had mean PTV reductions of 16, 19 and 33%, respectively. Conclusion: When implementing VMAT with 4D-CBCT-based image guidance, an ITV-based approach with a tighter margin than the commonly used 5 mm margin remains an alternative to the MidV-based approach for reducing healthy tissue exposure in lung SBRT. Compared to PTVMidV, PTVITV + 3mm significantly reduced the PTV while still maintaining an adequate in-treatment target coverage.
- Open Access
- 13 August 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 147
Optimized radiotherapy to improve clinical outcomes for locally advanced lung cancer
We aimed to evaluate the toxicity, loco-regional control (LRC) and overall survival (OS) associated with accelerated intensity-modulated radiotherapy (IMRT) for locally advanced lung cancer. Seventy-three patients were consecutively treated with IMRT from November 2011 to August 2016. A total dose of 66 Gy was delivered using two different schedules of radiotherapy: simultaneous modulated accelerated radiotherapy (SMART) (30 × 2.2 Gy, across 6 weeks) with or without chemotherapy, or moderate hypofractionated radiotherapy (HRT) (24 × 2.75 Gy, across 4 weeks) in patients unfit to receive concomitant chemotherapy. Data on esophageal and pulmonary toxicities, LRC and OS were prospectively collected. The median follow-up duration was 44 months. Severe pneumonitis and esophagitis (grade 3–4) were observed in 7% and 1% of patients respectively, with only one case of grade 4 (pneumonitis). Overall, the 1-year and 2-year LRCs were 76% [95 confidence interval (CI)%: 66–87%] and 62% [95 CI%: 49–77%] respectively. The 1 and 2-year OS rates were 72% [95% CI: 63–83%] and 54% [95 CI%: 43–68%] respectively. None parameters were correlated with LRC or OS. In particular, no difference was observed between patients treated with SMART and H-RT (p = 0.26 and 0.6 respectively), with a 1-year LRC of 74% [95 CI%: 62–86%] for SMART and 91% [95 CI%: 74–100%] for H-RT. No significant differences were observed in the toxicity rates associated with each of the RT schedules. Accelerated IMRT for locally advanced lung cancer is associated with low toxicities and high LRC. Moderate hypofractionated RT, by decreasing the total treatment time, may be promising in improving clinical outcomes.
- 13 August 2018
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 147
Open AccessOptimized radiotherapy to improve clinical outcomes for locally advanced lung cancer
We aimed to evaluate the toxicity, loco-regional control (LRC) and overall survival (OS) associated with accelerated intensity-modulated radiotherapy (IMRT) for locally advanced lung cancer. Seventy-three patients were consecutively treated with IMRT from November 2011 to August 2016. A total dose of 66 Gy was delivered using two different schedules of radiotherapy: simultaneous modulated accelerated radiotherapy (SMART) (30 × 2.2 Gy, across 6 weeks) with or without chemotherapy, or moderate hypofractionated radiotherapy (HRT) (24 × 2.75 Gy, across 4 weeks) in patients unfit to receive concomitant chemotherapy. Data on esophageal and pulmonary toxicities, LRC and OS were prospectively collected. The median follow-up duration was 44 months. Severe pneumonitis and esophagitis (grade 3–4) were observed in 7% and 1% of patients respectively, with only one case of grade 4 (pneumonitis). Overall, the 1-year and 2-year LRCs were 76% [95 confidence interval (CI)%: 66–87%] and 62% [95 CI%: 49–77%] respectively. The 1 and 2-year OS rates were 72% [95% CI: 63–83%] and 54% [95 CI%: 43–68%] respectively. None parameters were correlated with LRC or OS. In particular, no difference was observed between patients treated with SMART and H-RT (p = 0.26 and 0.6 respectively), with a 1-year LRC of 74% [95 CI%: 62–86%] for SMART and 91% [95 CI%: 74–100%] for H-RT. No significant differences were observed in the toxicity rates associated with each of the RT schedules. Accelerated IMRT for locally advanced lung cancer is associated with low toxicities and high LRC. Moderate hypofractionated RT, by decreasing the total treatment time, may be promising in improving clinical outcomes.
- 1 July 2017
- Published by Elsevier in Physica Medica
- Vol. 39, 50-58
Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs
- 1 July 2017
- Published by Elsevier in Physica Medica
- Vol. 39, 50-58
Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs
- Open Access
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S509
PO-0919: Stereotactic radiotherapy for brain metastases : Cyberknife versus VersaHD / ExacTrac
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S509
Open AccessPO-0919: Stereotactic radiotherapy for brain metastases : Cyberknife versus VersaHD / ExacTrac
- Open Access
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S444
PO-0826: Evaluation of the new InCise MLC for Cyberknife stereotactic radiotherapy
- 1 May 2017
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 123, S444
Open AccessPO-0826: Evaluation of the new InCise MLC for Cyberknife stereotactic radiotherapy
- 1 December 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 360-361
41. Stereotactic radiotherapy for brain metastases: Cyberknife® rsaHD®/ ExacTrac®
- 1 December 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 360-361
41. Stereotactic radiotherapy for brain metastases: Cyberknife® rsaHD®/ ExacTrac®
- Open Access
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S755-S756
EP-1622: Cyberknife® M6TM: peripheral dose evaluation in brain treatments
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S755-S756
Open AccessEP-1622: Cyberknife® M6TM: peripheral dose evaluation in brain treatments