Zhengfei Zhuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengfei Zhuang has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Tongsheng Chen
MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China
9 shared publications - Min Hu
MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China
5 shared publications Xinghong Cai
MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China
4 shared publicationsAo Yin
Key Laboratory of Laser Life Science, Ministry of Education, College of Biophotonics South China Normal University Guangzhou Guangdong China
3 shared publicationsGuiping Zhuang
3 shared publicationsHan Sun
Key Laboratory of Laser Life Science, Ministry of Education, College of Biophotonics South China Normal University Guangzhou Guangdong China
3 shared publications
Latest Publications
- 1 October 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 130
CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images
- 1 October 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 130
CRSS: Consistency-regularized semi-supervised spectral unmixing for multicolor fluorescence microscopy images
- Open Access
LED Color Mixing and Temperature Compensation Method Based on Hybrid Genetic Particle Swarm Optimization (HGPSO)
Light-emitting diode (LED) sources for high-end display and professional lighting must maintain color-point accuracy and color-rendering stability over a wide correlated color temperature (CCT) range. Three-color mixing places the color point on the Planckian locus, but non-synchronous thermal drift of the channels induces CCT shift, instability, and color-rendering degradation during long-term operation. This paper proposes a green–azure–warm-white (GAW) mixing and temperature-compensation method based on the hybrid genetic–particle swarm optimization (HGPSO) algorithm. For each channel, three-Gaussian chromaticity–temperature and spectral-power-distribution–temperature models are established, and the Duv tolerance is converted into per-channel duty-cycle bounds that shrink the HGPSO search space, enabling lookup-table-based real-time compensation on an embedded MCU. Within the 30–90 °C solder-pad range, compensation reduced the average CCT deviation at 65 °C and 85 °C from 115 K and 199 K to 14.3 K and 15.8 K and the average || from 0.00167 and 0.0023 to within 0.001. The average deviation fell from 0.58% and 1.28% to 0.44% and 0.51% and the average deviation from 1.83% and 2.69% to 0.27% and 0.32%. The luminous-efficacy deviation remains within ±5% below 4500 K (maximum −8.05% at 6500 K). Cross-vendor validation confirms the portability of the method for long-term color consistency in display and lighting systems.Open AccessLED Color Mixing and Temperature Compensation Method Based on Hybrid Genetic Particle Swarm Optimization (HGPSO)
Light-emitting diode (LED) sources for high-end display and professional lighting must maintain color-point accuracy and color-rendering stability over a wide correlated color temperature (CCT) range. Three-color mixing places the color point on the Planckian locus, but non-synchronous thermal drift of the channels induces CCT shift, instability, and color-rendering degradation during long-term operation. This paper proposes a green–azure–warm-white (GAW) mixing and temperature-compensation method based on the hybrid genetic–particle swarm optimization (HGPSO) algorithm. For each channel, three-Gaussian chromaticity–temperature and spectral-power-distribution–temperature models are established, and the Duv tolerance is converted into per-channel duty-cycle bounds that shrink the HGPSO search space, enabling lookup-table-based real-time compensation on an embedded MCU. Within the 30–90 °C solder-pad range, compensation reduced the average CCT deviation at 65 °C and 85 °C from 115 K and 199 K to 14.3 K and 15.8 K and the average || from 0.00167 and 0.0023 to within 0.001. The average deviation fell from 0.58% and 1.28% to 0.44% and 0.51% and the average deviation from 1.83% and 2.69% to 0.27% and 0.32%. The luminous-efficacy deviation remains within ±5% below 4500 K (maximum −8.05% at 6500 K). Cross-vendor validation confirms the portability of the method for long-term color consistency in display and lighting systems. - 15 May 2026
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Molecular Cell Research
- Vol. 1873 (5) , 120159
USP8/GPX4-based live-cell quantitative FRET imaging for ferroptosis drug screening
- 15 May 2026
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Molecular Cell Research
- Vol. 1873 (5) , 120159
USP8/GPX4-based live-cell quantitative FRET imaging for ferroptosis drug screening
- Open Access
- 23 April 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
Fluorescence resonance energy transfer as a molecular ruler: Quantitative and semi-quantitative measurement approaches and emerging AI-enabled tools
Fluorescence Resonance Energy Transfer (FRET) is an optical tool for probing nanoscale molecular interactions and dynamics. Although widely used, reliable quantitative and semi-quantitative estimation of FRET efficiency remains challenging because different measurement modalities rely on distinct photophysical assumptions, correction steps, and analytical models. In this review, we summarize major strategies for FRET efficiency estimation, including intensity-based approaches (e.g., sensitized emission and acceptor photobleaching), lifetime-based approaches (FLIM-FRET and time-resolved FRET), and representative assay formats such as FRET two-hybrid analysis, along with spectral, single-molecule, two-photon, and super-resolution variants. For each category, we compare the underlying physical principles, typical error sources and corrections, representative modeling strategies, and practical applicability across experimental constraints. We further synthesize recent advances in optical imaging and computational modeling and propose a practical workflow for integrating artificial intelligence into FRET quantification, covering data quality control, automated region-of-interest selection, calibration and parameter inference, and validation aimed at reproducible results. Finally, we discuss emerging opportunities enabled by on-instrument analytics (Edge AI and TinyML) for low-latency acquisition and analysis, and outline future directions toward high-throughput, cross-scale imaging and standardized quantitative workflows.
- 23 April 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
Open AccessFluorescence resonance energy transfer as a molecular ruler: Quantitative and semi-quantitative measurement approaches and emerging AI-enabled tools
Fluorescence Resonance Energy Transfer (FRET) is an optical tool for probing nanoscale molecular interactions and dynamics. Although widely used, reliable quantitative and semi-quantitative estimation of FRET efficiency remains challenging because different measurement modalities rely on distinct photophysical assumptions, correction steps, and analytical models. In this review, we summarize major strategies for FRET efficiency estimation, including intensity-based approaches (e.g., sensitized emission and acceptor photobleaching), lifetime-based approaches (FLIM-FRET and time-resolved FRET), and representative assay formats such as FRET two-hybrid analysis, along with spectral, single-molecule, two-photon, and super-resolution variants. For each category, we compare the underlying physical principles, typical error sources and corrections, representative modeling strategies, and practical applicability across experimental constraints. We further synthesize recent advances in optical imaging and computational modeling and propose a practical workflow for integrating artificial intelligence into FRET quantification, covering data quality control, automated region-of-interest selection, calibration and parameter inference, and validation aimed at reproducible results. Finally, we discuss emerging opportunities enabled by on-instrument analytics (Edge AI and TinyML) for low-latency acquisition and analysis, and outline future directions toward high-throughput, cross-scale imaging and standardized quantitative workflows.
- Open Access
All-in-One Weather Image Restoration with Asymmetric Mixture-of-Experts Model and Multi-Task Collaboration
Recent studies have achieved significant advances in all-in-one adverse weather image restoration, primarily driven by the development of sophisticated model architectures. In this work, we find that effectively coordinating the complex interactions and potential optimization conflicts among different restoration tasks is also a critical factor determining the overall performance of all-in-one adverse weather image restoration models. To this end, we propose an effective all-in-one adverse weather image restoration framework, named MOE-WIRNet, designed to harmonize the learning process across various degradation types and ensure well-balanced performance among different restoration tasks. To enhance training equilibrium, we integrate a multi-task collaboration optimization strategy into the framework, coordinating the convergence dynamics of distinct restoration objectives. Furthermore, we incorporate an asymmetric mixture-of-experts (MoE) architecture into the framework to effectively address the distinct degradation patterns and varying severity levels presented by different tasks. Extensive experiments demonstrate that our framework consistently outperforms current state-of-the-art models on multiple real-world adverse weather benchmark datasets.
Open AccessAll-in-One Weather Image Restoration with Asymmetric Mixture-of-Experts Model and Multi-Task Collaboration
Recent studies have achieved significant advances in all-in-one adverse weather image restoration, primarily driven by the development of sophisticated model architectures. In this work, we find that effectively coordinating the complex interactions and potential optimization conflicts among different restoration tasks is also a critical factor determining the overall performance of all-in-one adverse weather image restoration models. To this end, we propose an effective all-in-one adverse weather image restoration framework, named MOE-WIRNet, designed to harmonize the learning process across various degradation types and ensure well-balanced performance among different restoration tasks. To enhance training equilibrium, we integrate a multi-task collaboration optimization strategy into the framework, coordinating the convergence dynamics of distinct restoration objectives. Furthermore, we incorporate an asymmetric mixture-of-experts (MoE) architecture into the framework to effectively address the distinct degradation patterns and varying severity levels presented by different tasks. Extensive experiments demonstrate that our framework consistently outperforms current state-of-the-art models on multiple real-world adverse weather benchmark datasets.
- 3 September 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (5)
AutoFRET: An Image Processing-Based ROI Automated Selection Method for Quantitative FRET Measurements
The emission-based fluorescence resonance energy transfer (E-FRET), renowned for its rapid detection, noninvasiveness towards fluorophores, and compatibility with both wide-field and confocal microscopy, is extensively employed in dynamically monitoring intermolecular interactions within living cells. However, E-FRET requires manual screening of hundreds to thousands of images for regions meeting specific criteria, a labor-intensive process devoid of mature automation solutions. In this article, we introduce AutoFRET, the automated and efficient solution tailored for E-FRET experimentation. AutoFRET harnesses image processing algorithms to swiftly and precisely identify target regions amidst vast image datasets. Furthermore, to mitigate the impact of dead cells in images on experimental results, we devise a novel cell morphology-based approach for their identification and exclusion. AutoFRET significantly reduces the time commitment for E-FRET experimental data analysis, condensing the entire process to the minute level. Comprehensive experimental evaluations reveal an average accuracy exceeding 95% for AutoFRET. This research presents a highly automated and reliable platform that expeditiously quantifies molecular interactions in living cells leveraging FRET technology, poised to contribute to advancements in quantitative biological research.
- 3 September 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (5)
AutoFRET: An Image Processing-Based ROI Automated Selection Method for Quantitative FRET Measurements
The emission-based fluorescence resonance energy transfer (E-FRET), renowned for its rapid detection, noninvasiveness towards fluorophores, and compatibility with both wide-field and confocal microscopy, is extensively employed in dynamically monitoring intermolecular interactions within living cells. However, E-FRET requires manual screening of hundreds to thousands of images for regions meeting specific criteria, a labor-intensive process devoid of mature automation solutions. In this article, we introduce AutoFRET, the automated and efficient solution tailored for E-FRET experimentation. AutoFRET harnesses image processing algorithms to swiftly and precisely identify target regions amidst vast image datasets. Furthermore, to mitigate the impact of dead cells in images on experimental results, we devise a novel cell morphology-based approach for their identification and exclusion. AutoFRET significantly reduces the time commitment for E-FRET experimental data analysis, condensing the entire process to the minute level. Comprehensive experimental evaluations reveal an average accuracy exceeding 95% for AutoFRET. This research presents a highly automated and reliable platform that expeditiously quantifies molecular interactions in living cells leveraging FRET technology, poised to contribute to advancements in quantitative biological research.