Jean-Philippe Martin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jean-Philippe Martin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Serge Pierfederici
Université de Lorraine
10 shared publications - Farid Meibody-Tabar
Universit de Lorraine, CNRS, LEMTA, Nancy, France
4 shared publications - Matheepot Phattanasak
Department of Teacher Training in Electrical Engineering, Faculty of Technical Education, King Mongkuts University of Technology North Bangkok, Bangkok, Thailand
3 shared publications - Milad Bahrami
ENSEM—University of Lorraine
3 shared publications - Roghayeh Gavagsaz-Ghoachani
Shahid Beheshti University
3 shared publications - Babak Nahid-Mobarakeh
Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4L8, Canada
2 shared publications
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 257-269
Improved Nonlinear Control Method of a Rotating Diode Synchronous Generator Voltage
- 2 August 2026
- Published by Springer Nature
- p. 257-269
Improved Nonlinear Control Method of a Rotating Diode Synchronous Generator Voltage
- 29 May 2024
- Published by Springer Nature
- p. 271-282
Passivity Based Control of Two Distributed Generations in DC Microgrid
- 29 May 2024
- Published by Springer Nature
- p. 271-282
Passivity Based Control of Two Distributed Generations in DC Microgrid
- 29 May 2024
- Published by Springer Nature
- p. 199-212
Consensus-Based Distributed Primary Control for Accurate Power Sharing in Islanded Mesh Microgrids
- 29 May 2024
- Published by Springer Nature
- p. 199-212
Consensus-Based Distributed Primary Control for Accurate Power Sharing in Islanded Mesh Microgrids
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1
Proposed system based on a three-level boost converter to mitigate voltage imbalance in photovoltaic power generation systems
Voltage imbalance poses a challenge to photovoltaic systems. A modular structure based on a three-level boost converter is proposed to address this problem. The three-level boost converter offers advantages, such as a low current ripple and voltage stress, over a classic boost converter. These advantages offset the use of additional elements in the proposed converter circuit. Two capacitors are used in the proposed converter to enable the innovative connection between multiple sources and the three-level boost converter. The second capacitor of the first module is shared with the first capacitor of the second module. This structure is used in conjunction with a controller to balance the voltages in the system. The controller is based on an indirect sliding model, wherein the input current of each energy source and the output voltage balance are considered. The two-module system is simulated using Simulink MATLAB software. The simulation and experimental results validate the proposed system.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1
Proposed system based on a three-level boost converter to mitigate voltage imbalance in photovoltaic power generation systems
Voltage imbalance poses a challenge to photovoltaic systems. A modular structure based on a three-level boost converter is proposed to address this problem. The three-level boost converter offers advantages, such as a low current ripple and voltage stress, over a classic boost converter. These advantages offset the use of additional elements in the proposed converter circuit. Two capacitors are used in the proposed converter to enable the innovative connection between multiple sources and the three-level boost converter. The second capacitor of the first module is shared with the first capacitor of the second module. This structure is used in conjunction with a controller to balance the voltages in the system. The controller is based on an indirect sliding model, wherein the input current of each energy source and the output voltage balance are considered. The two-module system is simulated using Simulink MATLAB software. The simulation and experimental results validate the proposed system.
- Open Access
- 19 February 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (4) , 2243
New Decentralized Control of Mesh AC Microgrids: Study, Stability, and Robustness Analysis
In this paper, we investigated the power sharing issues in mesh islanded microgrids that contain several distributed generators (DGs) and loads connected to different points of common coupling (PCC). Firstly, an improved decentralized droop control algorithm is proposed to achieve the active and reactive power sharing of different DGs in reconfigurable mesh islanded microgrids. Accurate power sharing was obtained even though line parameters or the mesh microgrid configuration were unknown. Secondly a state-space model of the whole mesh microgrid was developed, considering several generators with their decentralized controllers, line feeders, and dynamic loads. This model was used to design parameters of droop controllers, to study the asymptotic stability and the robustness properties of the system. All strategies and analyses were validated by simulation based on the generic microgrid detailed in the standard IEEE 9bus test feeder.
- 19 February 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (4) , 2243
Open AccessNew Decentralized Control of Mesh AC Microgrids: Study, Stability, and Robustness Analysis
In this paper, we investigated the power sharing issues in mesh islanded microgrids that contain several distributed generators (DGs) and loads connected to different points of common coupling (PCC). Firstly, an improved decentralized droop control algorithm is proposed to achieve the active and reactive power sharing of different DGs in reconfigurable mesh islanded microgrids. Accurate power sharing was obtained even though line parameters or the mesh microgrid configuration were unknown. Secondly a state-space model of the whole mesh microgrid was developed, considering several generators with their decentralized controllers, line feeders, and dynamic loads. This model was used to design parameters of droop controllers, to study the asymptotic stability and the robustness properties of the system. All strategies and analyses were validated by simulation based on the generic microgrid detailed in the standard IEEE 9bus test feeder.
- Open Access
- 7 May 2020
- Published by MDPI AG in Mathematics
- Vol. 8 (5) , 739
Multi-Stack Lifetime Improvement through Adapted Power Electronic Architecture in a Fuel Cell Hybrid System
To deal with the intermittency of renewable energy resources, hydrogen as an energy carrier is a good solution. The Polymer Electrolyte Membrane Fuel Cell (PEMFC) as a device that can directly convert hydrogen energy to electricity is an important part of this solution. However, durability and cost are two hurdles that must be overcome to enable the mass deployment of the technology. In this paper, a management system is proposed for the fuel cells that can cope with the durability issue by a suitable distribution of electrical power between cell groups. The proposed power electronics architecture is studied in this paper. A dynamical average model is developed for the proposed system. The validation of the model is verified by simulation and experimental results. Then, this model is used to prove the stability and robustness of the control method. Finally, the energy management system is assessed experimentally in three different conditions. The experimental results validate the effectiveness of the proposed topology for developing a management system with which the instability of cells can be confronted. The experimental results verify that the system can supply the load profile even during the degradation mode of one stack and while trying to cure it.
- 7 May 2020
- Published by MDPI AG in Mathematics
- Vol. 8 (5) , 739
Open AccessMulti-Stack Lifetime Improvement through Adapted Power Electronic Architecture in a Fuel Cell Hybrid System
To deal with the intermittency of renewable energy resources, hydrogen as an energy carrier is a good solution. The Polymer Electrolyte Membrane Fuel Cell (PEMFC) as a device that can directly convert hydrogen energy to electricity is an important part of this solution. However, durability and cost are two hurdles that must be overcome to enable the mass deployment of the technology. In this paper, a management system is proposed for the fuel cells that can cope with the durability issue by a suitable distribution of electrical power between cell groups. The proposed power electronics architecture is studied in this paper. A dynamical average model is developed for the proposed system. The validation of the model is verified by simulation and experimental results. Then, this model is used to prove the stability and robustness of the control method. Finally, the energy management system is assessed experimentally in three different conditions. The experimental results validate the effectiveness of the proposed topology for developing a management system with which the instability of cells can be confronted. The experimental results verify that the system can supply the load profile even during the degradation mode of one stack and while trying to cure it.
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10925-10935
Design and Modeling of an Equalizer for Fuel Cell Energy Management Systems
During the lifespan of a Polymer Electrolyte Membrane Fuel Cell (PEMFC) system, some heterogeneities between the cells constituting the stack can appear. The voltage of one particular cell in a stack may decrease because of specific aging or local malfunctioning such as drying. As a result, more heat is generated in this cell leading to an increase in its temperature and thus an additional voltage loss. This snowball effect can result in the failure of the cell. Therefore, the lifetime of a PEMFC stack can be increased by applying energy management to its cells. Notable that the output voltage of a cell is lower than a stack. Hence, a high conversion ratio converter is necessary to implement such energy management. An efficient way to increase the output voltage is to connect the output capacitors of the converters such as the boosts in series. Ensuring the converters' controllability is a key point to implement energy management. In this paper, an equalizer system is proposed to ensure the controllability of the boost converters. The balancing speed and the low number of switches are the main advantages of this system. The validity of the proposed system is verified through simulation and experiments.
- 13 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10925-10935
Design and Modeling of an Equalizer for Fuel Cell Energy Management Systems
During the lifespan of a Polymer Electrolyte Membrane Fuel Cell (PEMFC) system, some heterogeneities between the cells constituting the stack can appear. The voltage of one particular cell in a stack may decrease because of specific aging or local malfunctioning such as drying. As a result, more heat is generated in this cell leading to an increase in its temperature and thus an additional voltage loss. This snowball effect can result in the failure of the cell. Therefore, the lifetime of a PEMFC stack can be increased by applying energy management to its cells. Notable that the output voltage of a cell is lower than a stack. Hence, a high conversion ratio converter is necessary to implement such energy management. An efficient way to increase the output voltage is to connect the output capacitors of the converters such as the boosts in series. Ensuring the converters' controllability is a key point to implement energy management. In this paper, an equalizer system is proposed to ensure the controllability of the boost converters. The balancing speed and the low number of switches are the main advantages of this system. The validity of the proposed system is verified through simulation and experiments.
- 22 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 7053-7066
Observer and Lyapunov-Based Control for Switching Power Converters With LC Input Filter
This paper proposes a control method for a switching power converter. This converter is connected to a dc-link of a dc microgrid system via an LC input filter. This control method is based on a Lyapunov stability analysis; all state variables are acquired for evaluating stability analysis, including the output current for calculating the load resistance. To reduce a number of sensor counts, the input current is estimated. Moreover, loss occurrence in the converter is observed to reduce static errors of the controlled state variables, especially the output voltage. The losses are modelled as a series input voltage source observed from the dc-dc converter and a parallel current source. The latter enables us to eliminate the output current sensor. Using information from the estimated current source, a load resistance can be calculated. A Lyapunov function candidate is chosen to ensure that the system, including the observer, operates in a stable manner. Based on evaluating the time-derivative of the chosen Lyapunov function, we obtain the switching command that makes the system operate stably in each sampling cycle. In this paper, the proposed technique is applied on a boost converter. The simulation and as well experimental results validate the proposed control.
- 22 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 7053-7066
Observer and Lyapunov-Based Control for Switching Power Converters With LC Input Filter
This paper proposes a control method for a switching power converter. This converter is connected to a dc-link of a dc microgrid system via an LC input filter. This control method is based on a Lyapunov stability analysis; all state variables are acquired for evaluating stability analysis, including the output current for calculating the load resistance. To reduce a number of sensor counts, the input current is estimated. Moreover, loss occurrence in the converter is observed to reduce static errors of the controlled state variables, especially the output voltage. The losses are modelled as a series input voltage source observed from the dc-dc converter and a parallel current source. The latter enables us to eliminate the output current sensor. Using information from the estimated current source, a load resistance can be calculated. A Lyapunov function candidate is chosen to ensure that the system, including the observer, operates in a stable manner. Based on evaluating the time-derivative of the chosen Lyapunov function, we obtain the switching command that makes the system operate stably in each sampling cycle. In this paper, the proposed technique is applied on a boost converter. The simulation and as well experimental results validate the proposed control.
- 9 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (4) , 3750-3764
Zero-Sequence Current Based Diagnostic Method for Open-Switch Fault Detection in Parallel Inverters System
In this paper, a practical online open-switch fault detection method is presented. The proposed open-switch fault detection method is used to detect the open-circuited fault switch in the parallel inverters system. This method can relieve the severe effects of the over-current stress, to avoid the secondary fault to the electrical components in the parallel inverters system. This method is based on the detection of the resulting zero-sequence current, under the fault conditions. The proposed algorithm is activated by detecting the zero-sequence current between the parallel units, under the open-switch fault conditions. The sign of the resulting zero-sequence current is related to the upper or the lower open-switch fault case. The faulty phase identification relies on the analysis and the investigation of only the current measurements information of the faulty inverter. This method can get rid of the effects of the load, to obtain a reliable identification. The effectiveness of the proposed open-switch fault detection algorithm, is theoretically analyzed and validated by the simulations and the experiments.
- 9 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (4) , 3750-3764
Zero-Sequence Current Based Diagnostic Method for Open-Switch Fault Detection in Parallel Inverters System
In this paper, a practical online open-switch fault detection method is presented. The proposed open-switch fault detection method is used to detect the open-circuited fault switch in the parallel inverters system. This method can relieve the severe effects of the over-current stress, to avoid the secondary fault to the electrical components in the parallel inverters system. This method is based on the detection of the resulting zero-sequence current, under the fault conditions. The proposed algorithm is activated by detecting the zero-sequence current between the parallel units, under the open-switch fault conditions. The sign of the resulting zero-sequence current is related to the upper or the lower open-switch fault case. The faulty phase identification relies on the analysis and the investigation of only the current measurements information of the faulty inverter. This method can get rid of the effects of the load, to obtain a reliable identification. The effectiveness of the proposed open-switch fault detection algorithm, is theoretically analyzed and validated by the simulations and the experiments.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3858-3867
Nonlinear Estimation of Stator Currents in a Wound Rotor Synchronous Machine
Reduction of the manufacturing costs is one of the major concerns in the automotive industries. Removing the current sensors on the electric powertrain is a way to achieve this. In this paper, the current sensors of a stator of a wound rotor synchronous machine have been removed. In order to keep the control of the electric powertrain, the solution proposed here is to estimate the missing currents. To do so, a nonlinear observer based on the convergence of a Lyapunov candidate function has been developed for this application and compared to an extended Kalman filter (EKF). Since the parameters of the system may vary according to the operating point and the wear of the system, the robustness of the observers are tested without and with model errors and then validated on an experimental bench with a successful current sensorless control.
- 9 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 54 (4) , 3858-3867
Nonlinear Estimation of Stator Currents in a Wound Rotor Synchronous Machine
Reduction of the manufacturing costs is one of the major concerns in the automotive industries. Removing the current sensors on the electric powertrain is a way to achieve this. In this paper, the current sensors of a stator of a wound rotor synchronous machine have been removed. In order to keep the control of the electric powertrain, the solution proposed here is to estimate the missing currents. To do so, a nonlinear observer based on the convergence of a Lyapunov candidate function has been developed for this application and compared to an extended Kalman filter (EKF). Since the parameters of the system may vary according to the operating point and the wear of the system, the robustness of the observers are tested without and with model errors and then validated on an experimental bench with a successful current sensorless control.