SJSiana Jones

Siana Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siana Jones has a total of 85 co-authors. Here are the top co-authors by number of shared publications:

  • Alun David Hughes

    Institute of Cardiovascular Science, University College London, London, UK

    12 shared publications
  • Nishi Chaturvedi

    MRC Unit for Lifelong Health & Ageing at UCL University College London London UK

    9 shared publications
  • Alun D. Hughes

    Department of Population Science and Experimental Medicine, University College London , London, U.K.

    7 shared publications
  • Suzanne Williams

    MRC Unit for Lifelong Health & Ageing at UCL, Department of Population Science and Experimental Medicine, Institute for Cardiovascular Science, University College London, London, United Kingdom

    7 shared publications
  • Therese Tillin

    MRC Unit for Lifelong Health & Ageing at UCL, Department of Population Science & Experimental Medicine, Institute for Cardiovascular Science, University College London, UK

    5 shared publications
  • Alexandra Jamieson

    MRC Unit for Lifelong Health and Ageing at UCL, Department of Population Science and Experimental Medicine, Institute for Cardiovascular Science, University College London, London, United Kingdom

    3 shared publications

Latest Publications

  • Open Access

    Retracted: Validation of a popular consumer-grade cuffless blood pressure device for continuous 24 h monitoring

    by Bhavini J Bhatt, Haashim Mohammad Amir, Siana Jones, Alexandra Jamieson, Nishi Chaturvedi, Alun Hughes, Michele Orini

    This article has been retracted. Please see https://doi.org/10.1093/ehjdh/ztag002 for details.


  • Open Access

    A short review of application of near-infrared spectroscopy (NIRS) for the assessment of microvascular post-occlusive reactive hyperaemia (PORH) in skeletal muscle

    by Elizabeth Hendrick, Alexandra Jamieson, Scott T. Chiesa, Alun D. Hughes, Siana Jones

    Near-infrared spectroscopy (NIRS) is an optical technique that can be used to non-invasively interrogate haemodynamic changes within skeletal muscle. It can be combined with a short (3–5 min) arterial cuff-occlusion to quantify post-occlusive reactive hyperaemia (PORH). This technique has utility in tracking changes in vascular health in relation to exercise, disease progression or treatment efficacy. However, methods for assessing PORH vary widely and there is little consensus on methodological approaches such as sampling frequency, correction for adipose tissue or the analysis endpoints. The purpose of this review was to: (1) summarise recent advances; (2) compare different methodological approaches and (3) identify current knowledge gaps and future objectives for use of NIRS for vascular assessment. We propose key areas for future work, including optimising occlusion duration and comparing methods of correction for the ischemic stimulus, standardising methods for adjustment of adipose tissue thickness, cross-device comparisons and establishing a standard for minimum sampling rate. Comparisons with alternative methods of capturing PORH or upstream vasodilatory responses would be valuable. Addressing these methodological considerations will aid our understanding of this useful, non-invasive tool for characterising PORH within skeletal muscle and facilitate interpretation of results across studies.


  • Open Access

    Near-infrared spectroscopy (NIRS) in vivo assessment of skeletal muscle oxidative capacity: a comparison of results from short versus long exercise protocols and reproducibility in non-athletic adults

    by Fistra J. Tandirerung, Alexandra Jamieson, Elizabeth Hendrick, Alun D. Hughes, Siana Jones

    Background: Near-infrared spectroscopy (NIRS) provides a non-invasive, cost-effective method for assessing skeletal muscle oxidative capacity when combined with a short exercise protocol and arterial occlusions. However, the impact of different exercise protocols and reproducibility of the method in non-athletic adults have not previously been assessed.Methods: Young, non-athletic adults (YA) were invited to perform a short duration, fast frequency contraction (SF) exercise protocol and a long duration slow frequency (LS) contraction protocol, combined with NIRS measurements and arterial occlusions to assess skeletal muscle oxidative capacity. YA and older non-athletic adults (OA; >65 years old) were invited to perform the SF exercise protocol twice to assess the reproducibility of this oxidative capacity measurement.Results: We included 25 participants (14 male (56%), age range: 18–86 years) in the analyses. There was a strong positive correlation and good agreement between time constants derived following the SF and LS exercise protocols (Lin’s concordance correlation coefficient: 0.69, p-value < 0.001 mean bias [LoA]: −3.2 [−31.0, 24.4] seconds. There was a strong positive correlation and good agreement between time constants derived from the SF exercise protocol in the YA & OA group (Lin’s concordance correlation coefficient: 0.63, p-value < 0.001; mean bias [LoA] −6.4 [−34.0, 21.3] seconds).Conclusion: These data provide evidence to suggest that NIRS is a reliable in vivo method for the assessment of skeletal muscle oxidative capacity irrespective of exercise protocol duration or muscle contraction frequency. NIRS-measured oxidative capacity via the SF exercise protocol was reproducible in non-athletic adults with a wide range in age.


  • Open Access

    Mechanisms underlying exercise intolerance in long COVID: An accumulation of multisystem dysfunction

    by Alexandra Jamieson, Lamia Al Saikhan, Lamis Alghamdi, Lee Hamill Howes, Helen Purcell, Toby Hillman, Melissa Heightman, Thomas Treibel, Michele Orini, Robert Bell, et al.

    The pathogenesis of exercise intolerance and persistent fatigue which can follow an infection with the SARS‐CoV‐2 virus (“long COVID”) is not fully understood. Cases were recruited from a long COVID clinic (N = 32; 44 ± 12 years; 10 (31%) men), and age‐/sex‐matched healthy controls (HC) (N = 19; 40 ± 13 years; 6 (32%) men) from University College London staff and students. We assessed exercise performance, lung and cardiac function, vascular health, skeletal muscle oxidative capacity, and autonomic nervous system (ANS) function. Key outcome measures for each physiological system were compared between groups using potential outcome means (95% confidence intervals) adjusted for potential confounders. Long COVID participant outcomes were compared to normative values. When compared to HC, cases exhibited reduced oxygen uptake efficiency slope (1847 (1679, 2016) vs. 2176 (1978, 2373) mL/min, p = 0.002) and anaerobic threshold (13.2 (12.2, 14.3) vs. 15.6 (14.4, 17.2) mL/kg/min, p < 0.001), and lower oxidative capacity, measured using near infrared spectroscopy (τ: 38.7 (31.9, 45.6) vs. 24.6 (19.1, 30.1) s, p = 0.001). In cases, ANS measures fell below normal limits in 39%. Long COVID is associated with reduced measures of exercise performance and skeletal muscle oxidative capacity in the absence of evidence of microvascular dysfunction, suggesting mitochondrial pathology. There was evidence of attendant ANS dysregulation in a significant proportion. These multisystem factors might contribute to impaired exercise tolerance in long COVID sufferers.


  • Open Access

    Mechanisms underlying exercise intolerance in Long COVID: an accumulation of multi-system dysfunction

    by Alexandra Jamieson, Lamia Al Saikhan, Lamis Alghamdi, Lee Hamill Howes, Helen Purcell, Toby Hillman, Melissa Heightman, Thomas Treibel, Michele Orini, Robert Bell, et al.

    The pathogenesis of exercise intolerance and persistent fatigue which can follow an infection with the SARS-CoV-2 virus (’Long COVID’) is not fully understood. Cases were recruited from a Long COVID clinic (N=32; 44±12y; 10(31%)men), and age/sex- matched healthy controls (HC) (N=19; 40±13y; 6(32%)men) from University College London staff and students. We assessed exercise performance, lung and cardiac function, vascular health, skeletal muscle oxidative capacity and autonomic nervous system (ANS) function. Key outcome measures for each physiological system were compared between groups using potential outcome means(95% confidence intervals) adjusted for potential confounders. Long COVID participant outcomes were compared to normative values. When compared to HC, cases exhibited reduced Oxygen Uptake Efficiency Slope (1847(1679,2016) vs (2176(1978,2373) ml/min, p=0.002) and Anaerobic Threshold (13.2(12.2,14.3) vs 15.6(14.4,17.2) ml/Kg/min, pKey Points The pathogenesis of exercise intolerance and persistent fatigue which can follow an infection with the SARS-CoV-2 virus (’Long COVID’) is not fully understood. We show that Long COVID is associated with reduced measures of exercise performance in line with previous work. In Long COVID cases, we observed reduced skeletal muscle oxidative capacity in the absence of evidence of microvascular dysfunction, suggesting mitochondrial pathology. We also observed evidence of attendant autonomic nervous system (ANS) dysregulation in a significant proportion of Long COVID cases. These multi-system factors might contribute to impaired exercise tolerance in Long COVID sufferers.

  • Open Access

    Differences Between Brachial And Aortic Blood Pressure In Adolescence and their implications for diagnosis of hypertension

    by Alun D. Hughes, George Davey Smith, Laura D. Howe, Debbie A. Lawlor, Siana Jones, Chloe M. Park, Nishi Chaturvedi

    Objectives: Blood pressure is the leading global cause of mortality, and its prevalence is increasing in children and adolescents. Aortic blood pressure (BP) is lower than brachial BP in adults. We aimed to assess the extent of this difference and its impact on the diagnosis of hypertension among adolescents. Methods: We used data from 3850 participants from a UK cohort of births in the early 1990s in the Southwest of England, who attended their ∼17 year follow-up and had valid measures of brachial and aortic BP at that clinic (mean(SD) age 17.8(0.4)y, 66% female). Data are presented as mean differences [95% prediction intervals] for both sexes. Results: Aortic systolic BP was lower than brachial systolic BP (male, -22.3[-31.2, - 13.3]mmHg; female, -17.8[-25.5, -10.0]mmHg). Differences between aortic and brachial diastolic BP were minimal. Based on brachial BP measurements, 101 males (6%) and 22 females (1%) were classified as hypertensive. In contrast, only nine males (<1%) and 14 females (<1%) met the criteria for hypertension based on aortic BP, and the predictive value of brachial BP for aortic hypertension was poor (positive predictive value = 13.8%). Participants with aortic hypertension had a higher left ventricular mass index than those with brachial hypertension. Conclusions: Brachial BP substantially overestimates aortic BP in adolescents due to marked aortic-to-brachial pulse pressure amplification. The use of brachial BP measurement may result in an overdiagnosis of hypertension during screening in adolescence.

  • Antihypertensive treatment effect on exercise blood pressure and exercise capacity in older adults

    by Siana Jones, Martin G. Schultz, Chloe Park, Therese Tillin, Nishi Chaturvedi, Alun D. Hughes

    Background: An exaggerated blood pressure (BP) response to exercise and low exercise capacity are risk factors for cardiovascular disease (CVD). The effect of pharmacological antihypertensive treatment on exercise BP in older adults is largely unknown. This study investigates these effects accounting for differences in exercise capacity. Methods: Participants enrolled in the Southall and Brent Revisited (SABRE) study undertook a 6-min stepper test with expired gas analysis and BP measured throughout exercise. Participants were stratified by antihypertensive treatment status and resting BP control. Exercise systolic and diastolic BP (exSBP and exDBP) were compared between groups using potential outcome means [95% confidence intervals (CIs)] adjusted for exercise capacity. Exercise capacity was also compared by group. Results: In total, 659 participants were included (mean age ± SD: 73 ± 6.6 years, 57% male). 31% of normotensive and 23% of hypertensive older adults with controlled resting BP had an exaggerated exercise BP. ExSBP was similar between normotensive and treated/controlled individuals [mean (95%CI): 180 (176 184) mmHg vs. 177 (173 181) mmHg, respectively] but was higher in treated/uncontrolled and untreated/uncontrolled individuals [mean (95% CI): 194 (190 197) mmHg, P < 0.001 and 199 (194 204) mmHg, P < 0.001, respectively]; these differences persisted after adjustment for exercise capacity and other confounders. Exercise capacity was lower in treated vs. normotensive individuals [mean (95% CI) normotensive: 16.7 (16.0,17.4) ml/kg/min]; treated/controlled: 15.5 (14.8,16.1) ml/kg/min, P = 0.009; treated/uncontrolled: [15.1 (14.5,15.7) ml/kg per min, P = 0.001] but was not reduced in untreated/uncontrolled individuals [mean (95% CI): 17.0 (16.1,17.8) ml/kg per min, P = 0.621]. Conclusion: Irrespective of resting BP control and despite performing less exercise, antihypertensive treatment does not fully mitigate an exaggerated BP response to exercise suggesting residual CVD risk in older adults.


  • Open Access

    Skeletal Muscle Tissue Saturation Changes Measured Using Near Infrared Spectroscopy During Exercise Are Associated With Post-Occlusive Reactive Hyperaemia

    by Siana Jones, Therese Tillin, Suzanne Williams, Alicja Rapala, Nishi Chaturvedi, Alun D. Hughes

    Measuring local haemodynamics in skeletal muscle has the potential to provide valuable insight into the oxygen delivery to tissue, especially during high demand situations such as exercise. The aim of this study was to compare the skeletal muscle microvascular response during post-occlusive reactive hyperaemia (PORH) with the response to exercise, each measured using near-infrared spectroscopy (NIRS) and to establish if associations exist between muscle measures and exercise capacity or sex. Participants were from a population-based cohort study, the Southall and Brent Revisited (SABRE) study. Skeletal muscle measures included changes in tissue saturation index at the onset of exercise (∆TSIBL-INC) and across the whole of exercise (∆TSIBL-EE), time to 50%, 95% and 100% PORH, rate of PORH recovery, area under the curve (AUC) and total oxygenated Haemoglobin (oxy-Hb) change during PORH. Exercise capacity was measured using a 6-min stepper test (6MST). Analysis was by multiple linear regression. In total, 558 participants completed the 6MST with NIRS measures of TSI (mean age±SD: 73 ± 7years, 59% male). A sub-set of 149 participants also undertook the arterial occlusion. Time to 100% PORH, recovery rate, AUC and ∆oxy-Hb were all associated with ∆TSIBL-EE (β-coefficient (95%CI): 0.05 (0.01, 0.09), p = 0.012; −47 (-85, −9.9), p = 0.014; 1.7 (0.62, 2.8), p = 0.002; 0.04 (0.002.0.108), p = 0.041, respectively). Time to 95% & 100% PORH, AUC and ∆oxy-Hb were all associated with ∆TSIBL-INC (β-coefficient (95%CI): −0.07 (−0.12,−0.02), p = 0.02; −0.03 (−0.05, −0.003), p = 0.028; 0.85 (0.18, 1.5), p = 0.013 & 0.05 (0.02, 0.09), p = 0.001, respectively). AUC and ∆Oxy-Hb were associated with steps achieved (β-coefficient (95%CI): 18.0 (2.3, 33.7), p = 0.025; 0.86 (0.10, 1.6), p = 0.027). ∆TSIBL-EE was associated with steps and highest VO2 (1.7 (0.49, 2.9), p = 0.006; 7.7 (3.2, 12.3), p = 0.001). ∆TSIBL-INC was associated with steps and VO2 but this difference was attenuated towards the null after adjustment for age, sex and ethnicity. ∆TSIBL-EE was greater in women (3.4 (0.4, 8.9) versus 2.1 (0.3, 7.4), p = 0.017) and ∆TSIBL-INC was lower in women versus men (2.4 (0.2, 10.2) versus 3.2 (0.2, 18.2), p = 0.016). These Local microvascular NIRS-measures are associated with exercise capacity in older adults and several measures can detect differences in microvascular reactivity between a community-based sample of men and women.


  • Open Access

    Association between carotid atherosclerosis and brain activation patterns during the Stroop task in older adults: An fNIRS investigation

    by Sarah A. Mason, Lamia Al Saikhan, Siana Jones, Sarah-Naomi James, Heidi Murray-Smith, Alicja Rapala, Suzanne Williams, Carole Sudre, Brian Wong, Marcus Richards, et al.