Thomas A. Foley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas A. Foley has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Nandan S. Anavekar
Mayo Clinic
5 shared publications- Abdallah El Sabbagh
Department of Cardiovascular Medicine, Mayo Clinic, Jacksonville, Florida, USA
2 shared publications Charanjit S. Rihal
Department of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
2 shared publicationsDavid R. Holmes
Department of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
2 shared publications- Eric Williamson
Diagnostic Radiology, Mayo Clinic Rochester, Rochester, MN, USA
2 shared publications Jane M. Matsumoto
Department of Radiology, Mayo Clinic, Rochester, MN, USA
2 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-8
Photon counting detector CTA for prostate arterial evaluation during the workup for prostate artery embolization
Purpose To evaluate small field of view (FOV) ultra-high spatial resolution pelvic photon-counting detector prostate CT angiograms (UHR PCD CTA) for identifying prostate arterial anatomy and extraprostatic anastomoses in patients undergoing workup for prostate artery embolization (PAE). Methods IRB-approved retrospective imaging and electronic medical record review of men who consecutively underwent UHR PCD CTA for PAE workup at our institution from 8/1/2022 to 12/1/2024. UHR PCD CTAs were evaluated by two vascular and interventional radiologists for main and accessory candidate prostatic arteries (PA/s) and anastomoses to penile, bladder, or rectal arteries. A main PA was defined as supplying the central gland and an accessory PA was defined as supplying the peripheral zone. PAs were categorized using the Carnevale classification. In patients who proceeded to PAE, digital subtraction angiograms (DSA) were retrospectively compared with UHR PCD CTA findings. Results UHR PCD CTA was obtained prior to PAE consultation for 50 men. We evaluated 100 pelvic sides, identifying 180 candidate PAs with a median of 3 candidate PAs per patient (mean, 3.6; range, 2–7). Overall, 56% (101/180) of candidate PAs were main and 44% (79/180) were accessory. Abridged Carnevale classifications: Type 5–21% (38/180). Eight accessory candidate PAs arose from the superior rectal artery. At least one candidate anastomosis arose from 40% (72/180) of candidate PAs. Of 95 total candidate anastomoses, 69 were extraprostatic (30 rectal, 20 bladder, 19 penile) and 26 were intraprostatic collaterals; 56% (53/95) arose from accessory and 44% (42/95) from main candidate PAs. Twenty-eight of 50 (56%) men underwent PAE, during which 72% (74/103) of available candidate PAs were selected, and prostatic supply was confirmed by DSA in 100% (74/74) of selected vessels. Conclusion Small FOV UHR PCD CTA is useful in identifying candidate PA supply, as well as potential extraprostatic anastomoses, providing an arterial roadmap for PAE planning. Candidate PA supply was confirmed by DSA in all selected vessels among patients who proceeded to PAE.
- 17 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-8
Open AccessPhoton counting detector CTA for prostate arterial evaluation during the workup for prostate artery embolization
Purpose To evaluate small field of view (FOV) ultra-high spatial resolution pelvic photon-counting detector prostate CT angiograms (UHR PCD CTA) for identifying prostate arterial anatomy and extraprostatic anastomoses in patients undergoing workup for prostate artery embolization (PAE). Methods IRB-approved retrospective imaging and electronic medical record review of men who consecutively underwent UHR PCD CTA for PAE workup at our institution from 8/1/2022 to 12/1/2024. UHR PCD CTAs were evaluated by two vascular and interventional radiologists for main and accessory candidate prostatic arteries (PA/s) and anastomoses to penile, bladder, or rectal arteries. A main PA was defined as supplying the central gland and an accessory PA was defined as supplying the peripheral zone. PAs were categorized using the Carnevale classification. In patients who proceeded to PAE, digital subtraction angiograms (DSA) were retrospectively compared with UHR PCD CTA findings. Results UHR PCD CTA was obtained prior to PAE consultation for 50 men. We evaluated 100 pelvic sides, identifying 180 candidate PAs with a median of 3 candidate PAs per patient (mean, 3.6; range, 2–7). Overall, 56% (101/180) of candidate PAs were main and 44% (79/180) were accessory. Abridged Carnevale classifications: Type 5–21% (38/180). Eight accessory candidate PAs arose from the superior rectal artery. At least one candidate anastomosis arose from 40% (72/180) of candidate PAs. Of 95 total candidate anastomoses, 69 were extraprostatic (30 rectal, 20 bladder, 19 penile) and 26 were intraprostatic collaterals; 56% (53/95) arose from accessory and 44% (42/95) from main candidate PAs. Twenty-eight of 50 (56%) men underwent PAE, during which 72% (74/103) of available candidate PAs were selected, and prostatic supply was confirmed by DSA in 100% (74/74) of selected vessels. Conclusion Small FOV UHR PCD CTA is useful in identifying candidate PA supply, as well as potential extraprostatic anastomoses, providing an arterial roadmap for PAE planning. Candidate PA supply was confirmed by DSA in all selected vessels among patients who proceeded to PAE.
- 22 October 2021
- Published by Springer Nature
- p. 167-175
Correlation of 3DE with CT and MRI in the Diagnosis and Assessment of Valvular Heart Disease and New Trends
- 22 October 2021
- Published by Springer Nature
- p. 167-175
Correlation of 3DE with CT and MRI in the Diagnosis and Assessment of Valvular Heart Disease and New Trends
- 22 October 2021
- Published by Springer Nature
- p. 223-227
CT and MRI Correlations with 3DE in Assessment of Prosthetic Valves Including New Trends
- 22 October 2021
- Published by Springer Nature
- p. 223-227
CT and MRI Correlations with 3DE in Assessment of Prosthetic Valves Including New Trends
- 22 October 2021
- Published by Springer Nature
- p. 453-458
Evolving Role of 3D Printing in Guiding Interventional Procedures
- 22 October 2021
- Published by Springer Nature
- p. 453-458
Evolving Role of 3D Printing in Guiding Interventional Procedures
- 1 November 2020
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 14 (6) , 502-509
Dynamic computed tomographic assessment of the mitral annulus in patients with and without mitral prolapse
- 1 November 2020
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 14 (6) , 502-509
Dynamic computed tomographic assessment of the mitral annulus in patients with and without mitral prolapse
- 10 May 2018
- Published by Springer Nature in Current Cardiology Reports
- Vol. 20 (6) , 47
The Various Applications of 3D Printing in Cardiovascular Diseases
To highlight the various applications of 3D printing in cardiovascular disease and discuss its limitations and future direction.
- 10 May 2018
- Published by Springer Nature in Current Cardiology Reports
- Vol. 20 (6) , 47
The Various Applications of 3D Printing in Cardiovascular Diseases
To highlight the various applications of 3D printing in cardiovascular disease and discuss its limitations and future direction.
- 23 January 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (7) , E537-E549
Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification
Introduction: Three‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).Methods: Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results: 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion: 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
- 23 January 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (7) , E537-E549
Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification
Introduction: Three‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).Methods: Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results: 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion: 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
- 11 July 2017
- Published by Springer Nature in Current Radiology Reports
- Vol. 5 (9) , 1-13
3D-Printing: Applications in Cardiovascular Imaging
- 11 July 2017
- Published by Springer Nature in Current Radiology Reports
- Vol. 5 (9) , 1-13
3D-Printing: Applications in Cardiovascular Imaging
- 10 January 2011
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 9 (1) , 45-61
Aneurysms of the ascending aorta and arch: the role of imaging in diagnosis and surgical management
Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture occurred. Better imaging techniques and an increase in the use of cross-sectional imaging has led to an increase in the diagnosis of aortic aneurysms, which has allowed for elective treatment prior to the development of a complication. The location, size and etiology of an aneurysm all impact the clinical outcomes and these factors are used to determine the appropriate timing of surgical replacement. Surgeons often rely on the information obtained from preoperative imaging to determine when to intervene and what type of procedure will be necessary, making it important for the radiologist to understand these issues in order to provide the necessary information. Postoperative imaging after surgical replacement of the aorta is also important, as there are some common findings that occur in this patient population that can impact how they are treated. The purpose of this article is to review the etiology and associated findings of aneurysms of the ascending aorta and arch, with a focus on how computed tomography angiography and magnetic resonance angiography findings are used to determine the appropriate timing for elective replacement and the type of surgical procedure, as well as the role of follow-up imaging. This will include a review of the most commonly performed types of surgical procedures, to provide an understanding of how the findings of preoperative imaging studies impact what the surgeon does in the operating room, as well as the expected findings of postoperative imaging studies.
- 10 January 2011
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 9 (1) , 45-61
Aneurysms of the ascending aorta and arch: the role of imaging in diagnosis and surgical management
Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture occurred. Better imaging techniques and an increase in the use of cross-sectional imaging has led to an increase in the diagnosis of aortic aneurysms, which has allowed for elective treatment prior to the development of a complication. The location, size and etiology of an aneurysm all impact the clinical outcomes and these factors are used to determine the appropriate timing of surgical replacement. Surgeons often rely on the information obtained from preoperative imaging to determine when to intervene and what type of procedure will be necessary, making it important for the radiologist to understand these issues in order to provide the necessary information. Postoperative imaging after surgical replacement of the aorta is also important, as there are some common findings that occur in this patient population that can impact how they are treated. The purpose of this article is to review the etiology and associated findings of aneurysms of the ascending aorta and arch, with a focus on how computed tomography angiography and magnetic resonance angiography findings are used to determine the appropriate timing for elective replacement and the type of surgical procedure, as well as the role of follow-up imaging. This will include a review of the most commonly performed types of surgical procedures, to provide an understanding of how the findings of preoperative imaging studies impact what the surgeon does in the operating room, as well as the expected findings of postoperative imaging studies.