TFThomas A. Foley

Thomas A. Foley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas A. Foley has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photon counting detector CTA for prostate arterial evaluation during the workup for prostate artery embolization

    by Forrest Linch, Prabhakar Rajiah, Michael Jundt, Alison Bashier, Kevin Wymer, Meghan Cooper, Derek Lomas, Andrea Ferrero, Christopher Favazza, Thomas Foley, et al.

    Purpose To evaluate small field of view (FOV) ultra-high spatial resolution pelvic photon-counting detector prostate CT angiograms (UHR PCD CTA) for identifying prostate arterial anatomy and extraprostatic anastomoses in patients undergoing workup for prostate artery embolization (PAE). Methods IRB-approved retrospective imaging and electronic medical record review of men who consecutively underwent UHR PCD CTA for PAE workup at our institution from 8/1/2022 to 12/1/2024. UHR PCD CTAs were evaluated by two vascular and interventional radiologists for main and accessory candidate prostatic arteries (PA/s) and anastomoses to penile, bladder, or rectal arteries. A main PA was defined as supplying the central gland and an accessory PA was defined as supplying the peripheral zone. PAs were categorized using the Carnevale classification. In patients who proceeded to PAE, digital subtraction angiograms (DSA) were retrospectively compared with UHR PCD CTA findings. Results UHR PCD CTA was obtained prior to PAE consultation for 50 men. We evaluated 100 pelvic sides, identifying 180 candidate PAs with a median of 3 candidate PAs per patient (mean, 3.6; range, 2–7). Overall, 56% (101/180) of candidate PAs were main and 44% (79/180) were accessory. Abridged Carnevale classifications: Type 5–21% (38/180). Eight accessory candidate PAs arose from the superior rectal artery. At least one candidate anastomosis arose from 40% (72/180) of candidate PAs. Of 95 total candidate anastomoses, 69 were extraprostatic (30 rectal, 20 bladder, 19 penile) and 26 were intraprostatic collaterals; 56% (53/95) arose from accessory and 44% (42/95) from main candidate PAs. Twenty-eight of 50 (56%) men underwent PAE, during which 72% (74/103) of available candidate PAs were selected, and prostatic supply was confirmed by DSA in 100% (74/74) of selected vessels. Conclusion Small FOV UHR PCD CTA is useful in identifying candidate PA supply, as well as potential extraprostatic anastomoses, providing an arterial roadmap for PAE planning. Candidate PA supply was confirmed by DSA in all selected vessels among patients who proceeded to PAE.

  • CT and MRI Correlations with 3DE in Assessment of Prosthetic Valves Including New Trends

    by Kathleen A. Young, Korosh Sharain, Nandan S. Anavekar, Thomas A. Foley

  • Dynamic computed tomographic assessment of the mitral annulus in patients with and without mitral prolapse

    by Asim Rizvi, Roy P. Marcus, Yugene Guo, Rickey Carter, Ian T. Mark, Thomas A. Foley, Nikkole M. Weber, Emily N. Sheedy, Shuai Leng, Eric E. Williamson


  • The Various Applications of 3D Printing in Cardiovascular Diseases

    by Abdallah El Sabbagh, Mackram F. Eleid, Mohammed Al-Hijji, Nandan S. Anavekar, David R. Holmes, Vuyisile T. Nkomo, Gustavo S. Oderich, Stephen D. Cassivi, Sameh M. Said, Charanjit S. Rihal, et al.

    To highlight the various applications of 3D printing in cardiovascular disease and discuss its limitations and future direction.


  • Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification

    by Abdallah El Sabbagh, Mackram F. Eleid, Jane M. Matsumoto, Nandan S. Anavekar, Mohammed A. Al‐Hijji, Sameh M. Said, Vuyisile T. Nkomo, David R. Holmes, Charanjit S. Rihal, Thomas A. Foley

    Introduction: Three‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).Methods: Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results: 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion: 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.


  • 3D-Printing: Applications in Cardiovascular Imaging

    by Thomas A. Foley, Abdallah El Sabbagh, Nandan S. Anavekar, Eric E. Williamson, Jane M. Matsumoto


  • Aneurysms of the ascending aorta and arch: the role of imaging in diagnosis and surgical management

    by Crystal R Bonnichsen, Thoralf M Sundt Iii, Nandan S Anavekar, Thomas A Foley, Michael F Morris, Matthew W Martinez, Eric E Williamson, James F Glockner, Philip A Araoz

    Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture occurred. Better imaging techniques and an increase in the use of cross-sectional imaging has led to an increase in the diagnosis of aortic aneurysms, which has allowed for elective treatment prior to the development of a complication. The location, size and etiology of an aneurysm all impact the clinical outcomes and these factors are used to determine the appropriate timing of surgical replacement. Surgeons often rely on the information obtained from preoperative imaging to determine when to intervene and what type of procedure will be necessary, making it important for the radiologist to understand these issues in order to provide the necessary information. Postoperative imaging after surgical replacement of the aorta is also important, as there are some common findings that occur in this patient population that can impact how they are treated. The purpose of this article is to review the etiology and associated findings of aneurysms of the ascending aorta and arch, with a focus on how computed tomography angiography and magnetic resonance angiography findings are used to determine the appropriate timing for elective replacement and the type of surgical procedure, as well as the role of follow-up imaging. This will include a review of the most commonly performed types of surgical procedures, to provide an understanding of how the findings of preoperative imaging studies impact what the surgeon does in the operating room, as well as the expected findings of postoperative imaging studies.