YSYuma Suzuki

Yuma Suzuki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuma Suzuki has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rapid ELISA Using a Film-Stack Reaction Field with Micropillar Arrays

    by Yuma Suzuki, Kazuhiro Morioka, Soichiro Ohata, Tetsuhide Shimizu, Hizuru Nakajima, Katsumi Uchiyama, Ming Yang

    A film-stack reaction field with a micropillar array using a motor stirrer was developed for the high sensitivity and rapid enzyme-linked immunosorbent assay (ELISA) reaction. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in ELISAs were investigated using a reaction field with different micropillar array dimensions (5-µm, 10-µm and 50-µm gaps between the micropillars). The difference in fluorescence intensity between the well with the reaction field of 50-µm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between the micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time. The theoretical analysis of the physical parameters related with the biomolecule transport indicated that the reaction efficiency defined in this study was the dominant factor determining the fluorescence intensity for the short incubation time, whereas the volumetric rate of the circulating flow through the space between films and the specific surface area were the dominant factors for the long incubation time.


  • Development and evaluation of film-stack reaction field with a micro-pillars array for micro bio-analysis

    by Yuma Suzuki, Kazuhiro Morioka, Tetsuhide Shimizu, Hizuru Nakajima, Katsumi Uchiyama, Ming Yang

    A film-stack reaction field with a micro-pillars array using a motor stirrer was developed for the high sensitivity and rapid reaction in micro bio-analysis. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in Enzyme-linked immunoassays (ELISAs) were investigated using a reaction field with different micro-pillars array dimensions (5-μm, 10-μm and 50-μm gaps between micro pillars). The difference in fluorescence intensity between the well with the reaction field of 50-μm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time because of different factors related with the biomolecule transport in each incubation times.