TSTakuro Shiiba

Takuro Shiiba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takuro Shiiba has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Masanori Watanabe

    Department of Radiology, Fujita Health University Hospital, Toyoake, Japan

    5 shared publications
  • Kazuki Takano

    Department of Molecular Imaging, School of Medical Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-Cho, Toyoake-Shi, Aichi, 470-1192, Japan

    4 shared publications
  • Yasushi Kihara

    Department of Radiology, Koga General Hospital, Miyazaki, Japan

    4 shared publications
  • Yasuyoshi Kuroiwa

    Department of Radiological Technology, Koga General Hospital, Miyazaki, Japan

    4 shared publications
  • Akihiro Takaki

    Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, Fukuoka, Japan

    3 shared publications
  • Kosuke Yamashita

    Department of Medical Imaging Technology, Division of Advanced Biomedical Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto , Japan

    3 shared publications

Latest Publications

  • Characterization of open-source BSREM reconstruction for 123I-FP-CIT SPECT on a conventional Anger-type SPECT/CT system: a phantom study

    by Takuro Shiiba, Shingo Tanahashi, Kohei Takasu, Yutaro Hamajima, Kosuke Yamashita, Masakazu Tsujimoto

    This study characterized the recovery-variability trade-off, count-level dependence, and region-specific behavior of open-source block-sequential regularized expectation maximization (BSREM) reconstruction for 123I-FP-CIT single-photon emission computed tomography acquired on a conventional Anger-type SPECT/CT system. Striatal phantom data with normal and asymmetric reduced-putaminal uptake were reconstructed using literature-based ordered-subsets expectation maximization (OSEM) implemented in the vendor software, PyTomography OSEM, and PyTomography BSREM. A BSREM operating point (β = 0.08, γ = 6.0) was selected using background coefficient of variation (CV) and whole-striatal uptake ratio (SUR). Reduced-count datasets at 75%, 50%, and 25% of the original counts were generated by binomial thinning. Metrics included CV, regional SUR, asymmetry index, caudate-to-putamen ratio (CPR), and full width at half maximum (FWHM). In the normal phantom, BSREM yielded lower CV and higher SUR than both OSEM implementations. In the abnormal phantom, BSREM generally yielded higher regional SURs, whereas mean caudate FWHM was 22.6 mm for vendor-software OSEM and 16.9 mm for PyTomography OSEM, and 17.5 mm for BSREM. However, reduced left-putaminal uptake remained underestimated, and putaminal asymmetry moved further from their theoretical values. At the 25% count level, background CV increased to 30.0 ± 6.1% with BSREM and 28.0 ± 5.9% with PyTomography OSEM. Open-source BSREM therefore showed task-, region-, and count-dependent behavior, supporting task- and count-specific parameter selection before clinical application.

  • Phantom-based optimization of [18F]fluciclovine neuro-oncology imaging on a high-resolution dedicated head PET system: dual-pathway reconstruction protocols

    by Takuro Shiiba, Hiroyuki Azuma, Kento Maeda, Shingo Tanahashi, Masanori Watanabe, Kosuke Yamashita, Masakazu Tsujimoto, Shigeo Ohba, Yoshitaka Inui, Hiroshi Toyama

    Purpose This study aimed to establish and evaluate two evidence-based reconstruction protocols for [18F]fluciclovine PET on a high-resolution dedicated head PET system: a time-efficient protocol for routine clinical use, and a high-quality protocol designed to maximize small-lesion detectability. Methods A brain-tumor phantom (target-to-background ratio, 5:1) was scanned on a dedicated head PET scanner (BresTome, Shimadzu). Using a 60-min list-mode acquisition, parameters were optimized for two visually defined pathways (10-min clinical-efficiency; 30-min high-quality). The optimization sequence involved optimizing the relaxation factor (β) using mean percent contrast (%contrastmean), followed by a comparison of post-reconstruction filters (non-local means [NLM] and Gaussian) by maximizing a local contrast-to-noise ratio (CNR), guided by the Rose criterion. The final protocols were evaluated against Japanese brain-tumor phantom criteria for key performance metrics, including maximum percent contrast (%contrastmax), relative recovery coefficient (RC), quantitative accuracy (SUVTOT), and uniformity (SDΔSUVmean). Results Two distinct protocols were established. The 10-min clinical-efficiency protocol was optimized with β = 60 and an NLM filter (intensity 1.5), which provided the best CNR for the 7.5-mm sphere. The 30-min high-quality protocol was optimized with β = 70 and an NLM filter (intensity 1.0), which yielded the highest CNR for the 5-mm sphere. The 30-min protocol was required for enhanced visibility of the 5-mm sphere. Both protocols met the Japanese criteria for %contrastmax, relative RC, and SUVTOT, whereas SDΔSUVmean did not meet the criterion. Supplementary reconstructions of the full 60-min dataset met the SDΔSUVmean criterion. In two representative clinical cases, application of the optimized protocols yielded clinically interpretable images with clear visualization of tumor uptake. Conclusion This study establishes a dual-pathway framework for [18F]fluciclovine PET. We recommend the 30-min high-quality protocol (β = 70, NLM intensity = 1.0) as the preferred option when feasible to maximize small-lesion detectability. The 10-min clinical-efficiency protocol (β = 60, NLM intensity = 1.5) serves as a practical, time-saving alternative for patients with limited tolerance. This approach provides a foundation for personalizing clinical protocols based on specific imaging needs and highlights the importance of standardizing uniformity assessment using an appropriate longer-duration reference acquisition for modern high-resolution PET systems.

  • Open Access

    Impact of 18F-FDG radioactivity outside the field of view on image quality in a SiPM-based time-of-flight dedicated breast PET scanner: a phantom study

    by Takuro Shiiba, Hana Katakami, Aiko Naito, Maki Takamura, Masanobu Ishiguro, Masanori Watanabe, Masaki Uno

    This study aimed to evaluate the impact of F-fluorodeoxyglucose (18F-FDG) uptake outside the field of view on image quality of a silicon photomultiplier tube (SiPM)–based dedicated breast (db) positron emission tomography scanner using a cylindrical breast phantom and simulated myocardium. The spheres, arranged in a planar circle inside the phantom, had 3, 5, 7.5, and 10 mm diameters. The cylinder and four spheres were filled with an 18F-FDG solution to maintain a sphere-to-background (BG) radioactivity concentration ratio of 8:1. The cylindrical breast phantom was positioned so that the centre position of the detector was aligned with the centre of the hot sphere. To simulate 18F-FDG accumulation in the myocardium, a cylindrical plastic container filled with 18F-FDG was placed on the cylindrical breast phantom. Scans were performed without and with varying levels of myocardial radioactivity concentration. The myocardial radioactivity concentration was set at ratios of 1, 5, 10, and 15 relative to the BG portion of the cylindrical breast phantom. The coefficient of variation of the BG (COVBG), contrast recovery coefficient (CRC), and detectability index (DI) were assessed. The COVBG tended to increase with higher myocardial radioactivity concentrations, but this trend was not entirely consistent. CRC showed a decreasing tendency for smaller hot spheres as myocardial radioactivity concentrations increased, with greater variability observed. DI tended to decrease as myocardial radioactivity concentrations increased. Our findings suggested that the presence of radioactivity outside the field of view increases reduces small-lesion contrast at the centre of the detector ring of the SiPM-based db positron emission tomography scanner.


  • A Pilot Study on Quantitative Accuracy and Radiomic Feature Stability of Deep Progressive Learning Reconstruction in NSCLC PET

    by Takuro Shiiba, Takeru Abe, Masanori Watanabe

    Deep progressive learning reconstruction (DPR) is a novel deep learning-based algorithm for PET imaging, yet its impact on quantitative metrics and radiomic feature stability is not fully characterized. This preliminary study systematically evaluated DPR against conventional ordered-subset expectation maximization (OSEM) in non-small cell lung cancer (NSCLC) PET imaging. In this retrospective study of 24 NSCLC patients, PET data were reconstructed using OSEM and three DPR strength levels. We compared standardized uptake values (SUV), contrast-to-noise ratio (CNR), and background noise. As a secondary objective, the stability of 93 radiomic features was quantified using an intra-patient coefficient of variation (COVRF) across all four reconstruction methods. DPR significantly increased SUV, particularly in smaller tumors, but this came at the expense of image quality, with only the lowest DPR strength improving CNR. The stability analysis revealed a stark stratification of radiomic features. While 31 features (33.3%) were robust against algorithmic changes (median COVRF ≤ 10%), a larger group of 38 features (40.9%), including the commonly used glcm_Contrast, proved highly unstable. In conclusion, DPR presents a critical trade-off between enhanced SUV quantification and image quality, requiring careful parameter optimization. Furthermore, our findings demonstrate that the stability of radiomic features is highly algorithm-dependent. The reliable application of advanced reconstruction techniques like DPR in quantitative and radiomic pipelines is therefore contingent upon a rigorous, evidence-based selection of features verified to be robust.


  • Optimizing LM-DRAMA parameters and non-local means filtering to improve small-lesion detectability in SiPM-based TOF breast PET

    by Takuro Shiiba, Hana Katakami, Aiko Naito, Maki Takamura, Masanobu Ishiguro, Masanori Watanabe, Masaki Uno

    This study aimed to optimize image reconstruction parameters for a dedicated time-of-flight (TOF) breast positron emission tomography (PET) system equipped with silicon photomultipliers (SiPMs) that maximize lesion detectability while minimizing image noise. A cylindrical phantom containing four hot spheres (3–10 mm diameter) was scanned at sphere-to-background ratios of 4:1, 6:1, and 8:1. All data were reconstructed using a 3D list-mode dynamic row-action maximum likelihood algorithm with β values of 10–200, followed by non-local means (NLM) filtering at intensities of 0.5–2.0 or no filtering. Image quality was evaluated using background coefficient of variation (COVBG), contrast recovery coefficient (CRC), and detectability index (DI) for the 3 mm sphere. As β increased, CRC and DI improved, particularly for smaller spheres and higher SBRs; however, background noise also rose. Applying the NLM filter reduced COVBG, especially when increasing the filter intensity from 0.5 to 1.0, although noise reduction gains plateaued at intensities above 1.0. Optimal trade-offs in lesion detectability and noise were observed at moderate β (50–100) with NLM intensities of 1.0–1.5, yielding higher CRC and DI without excessive background noise or blurring effects. A balanced approach to β and NLM filtering substantially enhances small-lesion visibility in SiPM-based TOF-dedicated breast PET imaging. These findings offer a practical framework for parameter selection, supporting better lesion detectability and advancing breast cancer diagnostics through more sensitive PET protocols.


  • Assessment of Age-Related Differences in Lower Leg Muscles Quality Using Radiomic Features of Magnetic Resonance Images

    by Takuro Shiiba, Suzumi Mori, Takuya Shimozono, Shuji Ito, Kazuki Takano

    Sarcopenia, characterised by a decline in muscle mass and strength, affects the health of the elderly, leading to increased falls, hospitalisation, and mortality rates. Muscle quality, reflecting microscopic and macroscopic muscle changes, is a critical determinant of physical function. To utilise radiomic features extracted from magnetic resonance (MR) images to assess age-related changes in muscle quality, a dataset of 24 adults, divided into older (male/female: 6/6, 66-79 years) and younger (male/female: 6/6, 21-31 years) groups, was used to investigate the radiomics features of the dorsiflexor and plantar flexor muscles of the lower leg that are critical for mobility. MR images were processed using MaZda software for feature extraction. Dimensionality reduction was performed using principal component analysis and recursive feature elimination, followed by classification using machine learning models, such as support vector machine, extreme gradient boosting, and naïve Bayes. A leave-one-out validation test was used to train and test the classifiers, and the area under the receiver operating characteristic curve (AUC) was used to evaluate the classification performance. The analysis revealed that significant differences in radiomic feature distributions were found between age groups, with older adults showing higher complexity and variability in muscle texture. The plantar flexors showed similar or higher AUC than the dorsiflexors in all models. When the dorsiflexor muscles were combined with the plantar flexor muscles, they tended to have a higher AUC than when they were used alone. Radiomic features in lower-leg MR images reflect ageing, especially in the plantar flexor muscles. Radiomic analysis can offer a deeper understanding of age-related muscle quality than traditional muscle mass assessments.


  • Radiomics score derived from T1-w/T2-w ratio image can predict motor symptom progression in Parkinson’s disease

    by Takuya Shimozono, Takuro Shiiba, Kazuki Takano

    Objectives To clarify the association between a radiomics score (Rad-score) derived from T1-weighted signal intensity to T2-weighted signal intensity (T1-w/T2-w) ratio images and the progression of motor symptoms in Parkinson’s disease (PD). Materials and methods This retrospective study included patients with PD enrolled in the Parkinson’s Progression Markers Initiative. The Movement Disorders Society-Unified Parkinson’s Disease Rating Scale Part III score ≥ 33 and/or Hoehn and Yahr stage ≥ 3 indicated motor function decline. The Rad-score was constructed using radiomics features extracted from T1-w/T2-w ratio images. The Kaplan-Meier analysis and Cox regression analyses were used to assess the time differences in motor function decline between the high and low Rad-score groups. Results A total of 171 patients with PD were divided into training (n = 101, mean age at baseline, 61.6 ± 9.3 years) and testing (n = 70, mean age at baseline, 61.6 ± 10 years). The patients in the high Rad-score group had a shorter time to motor function decline than those in the low Rad-score group in the training dataset (log-rank test, p < 0.001) and testing dataset (log-rank test, p < 0.001). The multivariate Cox regression using the Rad-score and clinical factors revealed a significant association between the Rad-score and motor function decline in the training dataset (HR = 2.368, 95%CI:1.423–3.943, p < 0.001) and testing dataset (HR = 2.931, 95%CI:1.472–5.837, p = 0.002). Conclusion Rad-scores based on radiomics features derived from T1-w/T2-w ratio images were associated with the progression of motor symptoms in PD. Clinical relevance statement The radiomics score derived from the T1-weighted/T2-weighted ratio images offers a predictive tool for assessing the progression of motor symptom in patients with PD. Key Points Radiomics score derived from T1-weighted/T2-weighted ratio images is correlated with the motor symptoms of Parkinson’s disease. A high radiomics score correlated with faster motor function decline in patients with Parkinson’s disease. The proposed radiomics score offers predictive insight into the progression of motor symptoms of Parkinson’s disease.


  • Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization

    by Takuro Shiiba, Masanori Watanabe

    In this study, we compared the repeatability and reproducibility of radiomic features obtained from positron emission tomography (PET) images according to the reconstruction algorithm used—advanced reconstruction algorithms, such as HYPER iterative (IT), HYPER deep learning reconstruction (DLR), and HYPER deep progressive reconstruction (DPR), or traditional Ordered Subset Expectation Maximization (OSEM)—to understand the potential variations and implications of using advanced reconstruction techniques in PET-based radiomics. We used a heterogeneous phantom with acrylic spherical beads (4- or 8-mm diameter) filled with 18F. PET images were acquired and reconstructed using OSEM, IT, DLR, and DPR. Original and wavelet radiomic features were calculated using SlicerRadiomics. Radiomic feature repeatability was assessed using the Coefficient of Variance (COV) and intraclass correlation coefficient (ICC), and inter-acquisition time reproducibility was assessed using the concordance correlation coefficient (CCC). For the 4- and 8-mm diameter beads phantom, the proportion of radiomic features with a COV < 10% was equivocal or higher for the advanced reconstruction algorithm than for OSEM. ICC indicated that advanced methods generally outperformed OSEM in repeatability, except for the original features of the 8-mm beads phantom. In the inter-acquisition time reproducibility analysis, the combinations of 3 and 5 min exhibited the highest reproducibility in both phantoms, with IT and DPR showing the highest proportion of radiomic features with CCC > 0.8. Advanced reconstruction methods provided enhanced stability of radiomic features compared with OSEM, suggesting their potential for optimal image reconstruction in PET-based radiomics, offering potential benefits in clinical diagnostics and prognostics.