Marco Reinhard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marco Reinhard has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Georg Gläser
IMMS Institut fr Mikroelektronik- und Mechatronik-Systeme gemeinntzige GmbH (IMMS GmbH),Ilmenau,Germany
3 shared publications - Alexander Hofmann
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
2 shared publications - Alexander Rolapp
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
2 shared publications - André Richter2 shared publications
Dirk M. Nuernbergk
2 shared publications- Eric Schafer
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH), Ilmenau, Germany
2 shared publications
Latest Publications
- Open Access
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (4) , 535-544
Lock-In Pixel CMOS Image Sensor for Time-Resolved Fluorescence Readout of Lateral-Flow Assays
We present a CMOS image sensor (CIS) based time-resolved fluorescence (TRF) measurement system for filter-less, highly sensitive readout of lateral-flow assay (LFA) test strips. The CIS contains a 256 × 128 lock-in pixel (LIP) sensor array. Each pixel has a size of $10 \ {\mu }\mathrm{m}$ × $10 \ {\mu }\mathrm{m}$ and includes a photodiode acting as signal transducer. The LIP CIS was designed in a standard 0.18 ${\mu }$ $\mathrm{m}$ CMOS technology specifically for TRF applications. The LIP architecture blocks interfering light when fluorophores are excited and accumulates the emitted fluorescence light to be measured over multiple cycles after excitation. This allows to detect even small amounts of fluorescence light over a wide analyte concentration range. The LIP CIS based TRF reader was characterized in terms of reproducible and uniform signal intensities with use of appropriate Europium(III) [Eu 3+] chelate particles as fluorescence standards. We measured different concentrations of Eu-based nanoparticles (NP) on test strips with the TRF reader. The sensor system shows 5.1 orders of magnitude of detection dynamic range (DDR) with a limit of detection (LoD) of $0.1 \ \text{ng/cm}$ . In addition, using human C-reactive protein (hCRP) as a model analyte, we compared the developed TRF reader with a commercial colorimetric LFA reader. For the quantification of CRP, the LIP CIS based TRF reader demonstrates a DDR of 3.6 orders of magnitude with an excellent LoD of $0.05 \ \text{ng/mL}$ , which is 14 times better than the LoD of the commercial LFA reader.
- 21 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (4) , 535-544
Open AccessLock-In Pixel CMOS Image Sensor for Time-Resolved Fluorescence Readout of Lateral-Flow Assays
We present a CMOS image sensor (CIS) based time-resolved fluorescence (TRF) measurement system for filter-less, highly sensitive readout of lateral-flow assay (LFA) test strips. The CIS contains a 256 × 128 lock-in pixel (LIP) sensor array. Each pixel has a size of $10 \ {\mu }\mathrm{m}$ × $10 \ {\mu }\mathrm{m}$ and includes a photodiode acting as signal transducer. The LIP CIS was designed in a standard 0.18 ${\mu }$ $\mathrm{m}$ CMOS technology specifically for TRF applications. The LIP architecture blocks interfering light when fluorophores are excited and accumulates the emitted fluorescence light to be measured over multiple cycles after excitation. This allows to detect even small amounts of fluorescence light over a wide analyte concentration range. The LIP CIS based TRF reader was characterized in terms of reproducible and uniform signal intensities with use of appropriate Europium(III) [Eu 3+] chelate particles as fluorescence standards. We measured different concentrations of Eu-based nanoparticles (NP) on test strips with the TRF reader. The sensor system shows 5.1 orders of magnitude of detection dynamic range (DDR) with a limit of detection (LoD) of $0.1 \ \text{ng/cm}$ . In addition, using human C-reactive protein (hCRP) as a model analyte, we compared the developed TRF reader with a commercial colorimetric LFA reader. For the quantification of CRP, the LIP CIS based TRF reader demonstrates a DDR of 3.6 orders of magnitude with an excellent LoD of $0.05 \ \text{ng/mL}$ , which is 14 times better than the LoD of the commercial LFA reader.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays
In this paper, we present a filterless time-resolved fluorescence (TRF) measurement system with an optoelectronic CMOS sensor for highly sensitive readout of lateral flow assay (LFA) test strips. An application specific integrated circuit (ASIC) was designed in a standard 0.35-µm CMOS technology and includes a 5 × 5 CMOS sensor array. Each sensor pixel contains a 100 µm × 100 µm photodiode acting as signal transducer. For the precise control of the measurement sequence and its timing regime, a microcode engine (MCE) has been realized in a field-programmable gate array (FPGA). An active LED discharge concept was implemented to prevent long afterglow of the light source after it is turned off. To characterize the TRF reader with respect to uniform and reproducible signal intensities, suitable europium (III) [Eu 3+] chelate particles were used as fluorescence standards. Different concentrations of europium based nanoparticles (NP) on test strips were quantified with the TRF reader. Furthermore, we compared the developed TRF reader to a commercial colorimetric LFA reader system using human C-reactive protein (hCRP) as model analyte. The CMOS sensor ASIC based filterless TRF reader showed a detection dynamic range (DDR) of 4 orders of magnitude with a LoD of 0.2 ng/ml for the quantification of CRP, which was 3.5 times better than the LoD of the commercial LFA reader.
- 7 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Filterless TRF Reader with CMOS Sensor ASIC for Lateral Flow Immunoassays
In this paper, we present a filterless time-resolved fluorescence (TRF) measurement system with an optoelectronic CMOS sensor for highly sensitive readout of lateral flow assay (LFA) test strips. An application specific integrated circuit (ASIC) was designed in a standard 0.35-µm CMOS technology and includes a 5 × 5 CMOS sensor array. Each sensor pixel contains a 100 µm × 100 µm photodiode acting as signal transducer. For the precise control of the measurement sequence and its timing regime, a microcode engine (MCE) has been realized in a field-programmable gate array (FPGA). An active LED discharge concept was implemented to prevent long afterglow of the light source after it is turned off. To characterize the TRF reader with respect to uniform and reproducible signal intensities, suitable europium (III) [Eu 3+] chelate particles were used as fluorescence standards. Different concentrations of europium based nanoparticles (NP) on test strips were quantified with the TRF reader. Furthermore, we compared the developed TRF reader to a commercial colorimetric LFA reader system using human C-reactive protein (hCRP) as model analyte. The CMOS sensor ASIC based filterless TRF reader showed a detection dynamic range (DDR) of 4 orders of magnitude with a LoD of 0.2 ng/ml for the quantification of CRP, which was 3.5 times better than the LoD of the commercial LFA reader.
- 1 January 2018
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Journal of Microelectronics and Electronic Packaging
- Vol. 15 (1) , 1-8
High-Precision Mixed-Signal Sensor Interface for a Wide Temperature Range [0–300°C]
Sensor interfacing is a crucial component for today's systems in many application domains. Especially in automotive and manufacturing fields, high temperatures are encountered. For extracting the typically small sensor signals, an interface near the sensor is needed to provide high accuracy and robustness. This results in challenges in circuit design and architecture to avoid temperature-related nonideal effects. In this contribution, we present a novel system architecture for a Wheatstone bridge interfacing system. By encoding the sensor signal in time domain and augmenting the system with additional observations, we present a robust and precise sensor interface operating at up to 300°C without breaking accuracy or functional requirements because of high-temperature effects. We present a realization of this concept proven to be accurate within ±1.3% full scale over the full temperature range.
- 1 January 2018
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Journal of Microelectronics and Electronic Packaging
- Vol. 15 (1) , 1-8
High-Precision Mixed-Signal Sensor Interface for a Wide Temperature Range [0–300°C]
Sensor interfacing is a crucial component for today's systems in many application domains. Especially in automotive and manufacturing fields, high temperatures are encountered. For extracting the typically small sensor signals, an interface near the sensor is needed to provide high accuracy and robustness. This results in challenges in circuit design and architecture to avoid temperature-related nonideal effects. In this contribution, we present a novel system architecture for a Wheatstone bridge interfacing system. By encoding the sensor signal in time domain and augmenting the system with additional observations, we present a robust and precise sensor interface operating at up to 300°C without breaking accuracy or functional requirements because of high-temperature effects. We present a realization of this concept proven to be accurate within ±1.3% full scale over the full temperature range.
- 1 July 2017
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2017 (HiTEN) , 000036-000041
High-Precision Mixed-Signal Sensor Interface for a Wide Temperature Range [0° – 300°C]
Sensor interfacing is a crucial component for today's systems in many application domains. Especially in automotive and manufacturing fields, high temperatures are encountered. For extracting the typically small sensor signals, an interface near the sensor is needed to provide a high-accuracy and robustness. This results in challenges for circuit design and architecture to avoid temperature related non-ideal effects. In this contribution, we present a novel system architecture for a Wheatstone bridge interfacing system. By encoding the sensor signal in time domain and augmenting the system with additional obseravtions, we present a robust and precise sensor interface operating at up to 300°C. We present a realization of this concept proven to be accurate within ±1.3%FS over the full temperature range.
- 1 July 2017
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2017 (HiTEN) , 000036-000041
High-Precision Mixed-Signal Sensor Interface for a Wide Temperature Range [0° – 300°C]
Sensor interfacing is a crucial component for today's systems in many application domains. Especially in automotive and manufacturing fields, high temperatures are encountered. For extracting the typically small sensor signals, an interface near the sensor is needed to provide a high-accuracy and robustness. This results in challenges for circuit design and architecture to avoid temperature related non-ideal effects. In this contribution, we present a novel system architecture for a Wheatstone bridge interfacing system. By encoding the sensor signal in time domain and augmenting the system with additional obseravtions, we present a robust and precise sensor interface operating at up to 300°C. We present a realization of this concept proven to be accurate within ±1.3%FS over the full temperature range.