RCRobert K. Chin

Robert K. Chin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert K. Chin has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dose-escalated stereotactic body radiotherapy re-irradiation in patients with recurrent head and neck cancer: a prospective phase 2 study using automated non-coplanar volumetric modulated arc therapy

    by John Nikitas, Ting Martin Ma, Kiri Cook, Kaley Woods, Amar U. Kishan, Vishruth K. Reddy, John V. Hegde, Maie St. John, Wanxing Chai-Ho, Deborah Wong, et al.


  • Open Access

    ASSET: Auto-Segmentation of the Seventeen SEgments for Ventricular Tachycardia Ablation in Radiation Therapy

    by Eric Morris, Robert Chin, Trudy Wu, Clayton Smith, Siamak Nejad-Davarani, Minsong Cao

    There has been a recent effort to treat high-risk ventricular tachycardia (VT) patients through radio-ablation. However, manual segmentation of the VT target is complex and time-consuming. This work introduces ASSET, or Auto-segmentation of the Seventeen SEgments for Tachycardia ablation, to aid in radiation therapy (RT) planning. ASSET was retrospectively applied to CTs for 26 thoracic RT patients (13 undergoing VT ablation). The physician-defined parasternal long-axis of the left ventricle (LV) and the axes generated from principal component analysis (PCA) were compared using mean distance to agreement (MDA) and angle of separation. The manually selected right ventricle insertion point and LVs were used to apply the ASSET model to automatically generate the 17 segments of the LV myocardium (LVM). Physician-defined parasternal long-axis differed from PCA by 1.2 ± 0.3 mm MDA and 6.9 ± 0.7 degrees. Segments differed by 0.69 ± 0.29 mm MDA and 0.89 ± 0.03 Dice similarity coefficient. Running ASSET takes 2 h/patient. Agreement between ASSET and expert contours was comparable to inter-observer variability. Qualitative scoring conducted by three experts revealed automatically generated segmentations were clinically useable as-is. ASSET offers efficient and reliable automatic segmentations for the 17 segments of the LVM for target generation in RT planning.


  • High Recurrence for HPV-Positive Oropharyngeal Cancer With Neoadjuvant Radiation Therapy to Gross Disease Plus Immunotherapy: Analysis From a Prospective Phase Ib/II Clinical Trial

    by Ting Martin Ma, Deborah J. Wong, Wanxing Chai-Ho, Abie Mendelsohn, Maie St. John, Elliot Abemayor, Dinesh Chhetri, Dipti Sajed, Audrey Dang, Fang-I Chu, et al.


  • Open Access

    A Prospective Phase II Study of Automated Non-Coplanar VMAT for Recurrent Head and Neck Cancer: Initial Report of Feasibility, Safety, and Patient-Reported Outcomes

    by Kaley E. Woods, Ting Martin Ma, Kiri A. Cook, Eric D. Morris, Yu Gao, Ke Sheng, Amar U. Kishan, John V. Hegde, Carol Felix, Vincent Basehart, et al.

    This study reports the initial results for the first 15 patients on a prospective phase II clinical trial exploring the safety, feasibility, and efficacy of the HyperArc technique for recurrent head and neck cancer treatment. Eligible patients were simulated and planned with both conventional VMAT and HyperArc techniques and the plan with superior dosimetry was selected for treatment. Dosimetry, delivery feasibility and safety, treatment-related toxicity, and patient-reported quality of life (QOL) were all evaluated. HyperArc was chosen over conventional VMAT for all 15 patients and enabled statistically significant increases in dose conformity (R50% reduced by 1.2 ± 2.1, p < 0.05) and mean PTV and GTV doses (by 15.7 ± 4.9 Gy, p < 0.01 and 17.1 ± 6.0 Gy, p < 0.01, respectively). The average HyperArc delivery was 2.8 min longer than conventional VMAT (p < 0.01), and the mean intrafraction motion was ≤ 0.5 ± 0.4 mm and ≤0.3 ± 0.1°. With a median follow-up of 12 months, treatment-related toxicity was minimal (only one grade 3 acute toxicity above baseline) and patient-reported QOL metrics were favorable. HyperArc enabled superior dosimetry and significant target dose escalation compared to conventional VMAT planning, and treatment delivery was feasible, safe, and well-tolerated by patients.


  • Open Access

    Simultaneous radiosurgery for multiple brain metastases: technical overview of the UCLA experience

    by Nzhde Agazaryan, Steve Tenn, Chul Lee, Michael Steinberg, John Hegde, Robert Chin, Nader Pouratian, Isaac Yang, Won Kim, Tania Kaprealian

    Purpose/objective(s): To communicate our institutional experience with single isocenter radiosurgery treatments for multiple brain metastases, including challenges with determining planning target volume (PTV) margins and resulting consequences, image-guidance translational and rotational tolerances, intra-fraction patient motion, and prescription considerations with larger PTV margins. Materials/methods: Eight patient treatments with 51 targets were planned with various margins using Elements Multiple Brain Mets SRS treatment planning software (Brainlab, Munich, Germany). Forty-eight plans with 0 mm, 1 mm and 2 mm margins were created, including plans with variable margins, where targets more than 6 cm away from the isocenter were planned with larger margins. The dosimetric impact of the margins were analyzed with V5Gy, V8Gy, V10Gy, V12Gy values. Additionally, 12 patient motion data were analyzed to determine both the impact of the repositioning threshold and the distributions of the patient translational and rotational movements. Results: The V5Gy, V8Gy, V10Gy, V12Gy volumes approximately doubled when margins change from 0 to 1 mm and tripled when change from 0 to 2 mm. With variable margins, the aggregated results are similar to results from plans using the lower of two margins, since only 12.2% of the targets were more than 6 cm away from the isocenter. With 0.5 mm re-positioning threshold, 57.4% of the time the patients are repositioned. Reducing the threshold to 0.25 mm results in 91.7% repositioning rate, due to limitations of the fusion algorithm and actual patient motion. The 90th percentile of translational movements in all directions is 0.7 mm, while the 90th percentile of rotational movements in all directions is 0.6 degrees. Median translations and rotations are 0.2 mm and 0.2 degrees, respectively. Conclusions: Based on the data presented, we have switched our modus operandi from 2 to 1 mm PTV margins, with an eventual goal of using 0.5 and 1.0 mm variable margins when an automated margin assignment method becomes available. The 0.5 mm and 0.5 degrees repositioning thresholds are clinically appropriate with small residual patient movements.


  • Open Access

    Automated Non-Coplanar VMAT for Dose Escalation in Recurrent Head and Neck Cancer Patients

    by Kaley Woods, Robert K. Chin, Kiri A. Cook, Ke Sheng, Amar U. Kishan, John V. Hegde, Stephen Tenn, Michael L. Steinberg, Minsong Cao

    This study evaluates the potential for tumor dose escalation in recurrent head and neck cancer (rHNC) patients with automated non-coplanar volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) planning (HyperArc). Twenty rHNC patients are planned with conventional VMAT SBRT to 40 Gy while minimizing organ-at-risk (OAR) doses. They are then re-planned with the HyperArc technique to match these minimal OAR doses while escalating the target dose as high as possible. Then, we compare the dosimetry, tumor control probability (TCP), and normal tissue complication probability (NTCP) for the two plan types. Our results show that the HyperArc technique significantly increases the mean planning target volume (PTV) and gross tumor volume (GTV) doses by 10.8 ± 4.4 Gy (25%) and 11.5 ± 5.1 Gy (26%) on average, respectively. There are no clinically significant differences in OAR doses, with maximum dose differences of <2 Gy on average. The average TCP is 23% (± 21%) higher for HyperArc than conventional plans, with no significant differences in NTCP for the brainstem, cord, mandible, or larynx. HyperArc can achieve significant tumor dose escalation while maintaining minimal OAR doses in the head and neck—potentially enabling improved local control for rHNC SBRT patients without increased risk of treatment-related toxicities.


  • Addition of Chemotherapy Is Associated With Decreased Survival in Early-Stage (T1-2N0M0) Glottic Squamous Cell Carcinoma Treated With Definitive Radiotherapy

    by Chenyang Wang, Amar U. Kishan, Ann Raldow, Philip Beron, Deborah J. Wong, Maie St John, Michael L. Steinberg, Robert Chin

    Purpose: The role of chemoradiation (CRT) in treating patients with early-stage glottic squamous cell carcinoma (SCC), especially for T2N0M0 glottic SCC with impaired vocal cord mobility, remains unexplored. We sought to evaluate the impact of CRT on survival in early-stage glottic SCC by using the SEER database. Patients and Methods: We included patients with localized (T1-4N0M0) glottic SCC (N = 4,743) diagnosed between 2004 and 2014 and treated with definitive radiotherapy (RT) alone, CRT, or laryngectomy alone in the SEER database. Disease-specific mortality (DSM) was evaluated via multivariable regression using a competing risk model that accounts for other-cause mortality as a competing risk event for DSM. One-to-one propensity score matching between CRT and RT cohorts was also performed to facilitate comparison of cumulative DSM and other-cause mortality incidences stratified by T stage. Results: After stratification by T stage, CRT was associated with increased DSM in T1-2N0M0 glottic SCC (adjusted hazard ratios [AHRs], 4.222 and 2.260 for T1 and T2 disease, respectively; P < .001 for both). For T2N0M0 glottic SCC with and without impaired vocal cord mobility, CRT resulted in significantly increased DSM compared with RT alone in both cohorts (AHR, 2.084; P = .046 and AHR, 2.412; P < .001, respectively). After propensity score matching, cumulative incidence plots demonstrated a statistically significant increase in DSM associated with CRT compared with RT alone for both T1 and T2 glottic SCC ( P < .001 and P = .003, respectively). Conclusion: CRT for T1-2N0M0 glottic SCC was associated with increased DSM compared with RT alone. This pattern persisted upon further stratification on the basis of vocal cord mobility status for T2N0M0 glottic SCC. This finding warrants careful consideration of chemotherapy in early-stage glottic SCC.


  • Advances in Radiation Oncology

    by John V. Hegde, Allen M. Chen, Robert K. Chin