Mitsutoshi Kimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mitsutoshi Kimura has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Kinoshita
Department of Cardiac Surgery, The University of Tokyo, Tokyo, Japan
6 shared publications Minoru Ono
Department of Cardiac Surgery, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan
4 shared publications- Eisuke Amiya
The University of Tokyo Hospital
3 shared publications Issei Komuro
3 shared publications- Kan Nawata
Department of Cardiac Surgery, Graduate School of Medicine, The University of Tokyo
3 shared publications - Masaru Hatano
Department of Cardiovascular Medicine, The University of Tokyo Hospital
3 shared publications
Latest Publications
- Open Access
- 24 October 2017
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 11 (1) , 1-6
Successful bridge to recovery in fulminant myocarditis using a biventricular assist device: a case report
Fulminant myocarditis is a life-threatening disease, and myocardial damage expands the right ventricle as well as the left ventricle in some cases. There is a mortality rate of over 40% in patients with fulminant myocarditis who need mechanical circulatory support by peripheral venoarterial extracorporeal membrane oxygenation. We report a case of a 27-year-old Japanese woman who was successfully bridged to recovery by using a biventricular assist device. She was diagnosed with fulminant myocarditis, and peripheral venoarterial extracorporeal membrane oxygenation was established on the same day. Her left ventricular ejection fraction rapidly decreased from 40% to 5% in 3 days and weaning from venoarterial extracorporeal membrane oxygenation was deemed difficult. Therefore, we performed a ventricular assist device implantation on day 4. A left ventricular assist device was implanted first. However, adequate blood flow did not circulate to the left side of her heart because of right-sided heart failure. Thus, an additional implant of a right ventricular assist device was performed during the operation. Her left ventricular ejection fraction recovered to 50% on day 10. The biventricular assist device was successfully removed on day 14. She has not experienced worsening of biventricular function during her follow-ups for 4 years. Ventricular assist device therapy should be considered if there is no improvement in cardiac function in patients with fulminant myocarditis regardless of several days of support by venoarterial extracorporeal membrane oxygenation. A right ventricular assist device should always be implemented when necessary because biventricular involvement is not uncommon in fulminant myocarditis.
- 24 October 2017
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 11 (1) , 1-6
Open AccessSuccessful bridge to recovery in fulminant myocarditis using a biventricular assist device: a case report
Fulminant myocarditis is a life-threatening disease, and myocardial damage expands the right ventricle as well as the left ventricle in some cases. There is a mortality rate of over 40% in patients with fulminant myocarditis who need mechanical circulatory support by peripheral venoarterial extracorporeal membrane oxygenation. We report a case of a 27-year-old Japanese woman who was successfully bridged to recovery by using a biventricular assist device. She was diagnosed with fulminant myocarditis, and peripheral venoarterial extracorporeal membrane oxygenation was established on the same day. Her left ventricular ejection fraction rapidly decreased from 40% to 5% in 3 days and weaning from venoarterial extracorporeal membrane oxygenation was deemed difficult. Therefore, we performed a ventricular assist device implantation on day 4. A left ventricular assist device was implanted first. However, adequate blood flow did not circulate to the left side of her heart because of right-sided heart failure. Thus, an additional implant of a right ventricular assist device was performed during the operation. Her left ventricular ejection fraction recovered to 50% on day 10. The biventricular assist device was successfully removed on day 14. She has not experienced worsening of biventricular function during her follow-ups for 4 years. Ventricular assist device therapy should be considered if there is no improvement in cardiac function in patients with fulminant myocarditis regardless of several days of support by venoarterial extracorporeal membrane oxygenation. A right ventricular assist device should always be implemented when necessary because biventricular involvement is not uncommon in fulminant myocarditis.
- 27 July 2017
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (4) , 311-317
Readmissions after continuous flow left ventricular assist device implantation
Continuous flow left ventricular assist device (CF-LVAD) therapy has improved the survival of patients with advanced heart failure. However, the readmission rate of CF-LVAD patients is still relatively high. A total of 90 patients who received CF-LVADs between April 2011 and March 2016 at our institute and were discharged home were analyzed retrospectively. They were followed up through March 2017. Clinical data, including frequency, length and etiology of readmission, were obtained from medical records. The mean observation period after initial discharge was 713 ± 322 days. In total, 73 patients (81%) had 236 readmissions, 214 unplanned and 22 planned. The overall and unplanned readmission rates were 1.34 and 1.22 per patient-year, respectively. The rate of freedom from unplanned first readmission at 1 year after initial discharge was 39%. The median interval between the previous hospital discharge and first and second readmissions was 311 and 213 days, respectively (log-rank test, p = 0.117). The rate of readmission after more than three readmissions was significantly higher than that of first or second readmission (log-rank test, p < 0.001). The most common etiology of readmission was driveline infection (DLI) (36%), followed by stroke (9%). The median length of hospital stay due to DLI was 23 days. The patients with repeated unplanned readmissions had significantly lower EuroQol 5 dimensions questionnaire utility score than those with no or just one readmission. Readmission was common in CF-LVAD patients, and the most common etiology of readmissions was DLI. The interval to the next readmission seemed shorter for patients with repeated readmissions.
- 27 July 2017
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 20 (4) , 311-317
Readmissions after continuous flow left ventricular assist device implantation
Continuous flow left ventricular assist device (CF-LVAD) therapy has improved the survival of patients with advanced heart failure. However, the readmission rate of CF-LVAD patients is still relatively high. A total of 90 patients who received CF-LVADs between April 2011 and March 2016 at our institute and were discharged home were analyzed retrospectively. They were followed up through March 2017. Clinical data, including frequency, length and etiology of readmission, were obtained from medical records. The mean observation period after initial discharge was 713 ± 322 days. In total, 73 patients (81%) had 236 readmissions, 214 unplanned and 22 planned. The overall and unplanned readmission rates were 1.34 and 1.22 per patient-year, respectively. The rate of freedom from unplanned first readmission at 1 year after initial discharge was 39%. The median interval between the previous hospital discharge and first and second readmissions was 311 and 213 days, respectively (log-rank test, p = 0.117). The rate of readmission after more than three readmissions was significantly higher than that of first or second readmission (log-rank test, p < 0.001). The most common etiology of readmission was driveline infection (DLI) (36%), followed by stroke (9%). The median length of hospital stay due to DLI was 23 days. The patients with repeated unplanned readmissions had significantly lower EuroQol 5 dimensions questionnaire utility score than those with no or just one readmission. Readmission was common in CF-LVAD patients, and the most common etiology of readmissions was DLI. The interval to the next readmission seemed shorter for patients with repeated readmissions.
- 1 September 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (9) , S155-S156
How to Come Through the Years' Waiting Period for Heart Transplant Under the Support of Implantable Left Ventricular Assist Device
- 1 September 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (9) , S155-S156
How to Come Through the Years' Waiting Period for Heart Transplant Under the Support of Implantable Left Ventricular Assist Device
- 1 May 2015
- Vol. 68 (5) , 323
[Temporary use of centrifugal pump for pump thrombosis in patients with paracorporeal ventricular assist device].
Nipro paracorporeal ventricular assist device( VAD) is often associated with pump thrombosis which causes severe complications such as brain infarction, often requiring pump change. However, Nipro VAD pump is an expensive device and it is difficult to change pumps frequently at a short interval. We have temporarily used Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs. From January 2012 through December 2013, 19 patients underwent Nipro VADs implantation at our institution, and 9 of them underwent pump change from Nipro pumps to Rotaflow centrifugal pumps. A total of 25 Rotaflow centrifugal pumps were used in these 9 patients, with the total circulatory support duration of 526 days. The median support period was 15 days (range;2-128 days). There were 2 cerebrovascular accidents and 1 Rotaflow pump circuit thrombosis during this period. Change from Rotaflow to Nipro VAD pump resulted in decrease in hematocrit by about 3 point. There was no difference in liver or renal function between before and after the pump change. Our results suggest that temporary use of Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs may be a promising alternative.
- 1 May 2015
- Vol. 68 (5) , 323
[Temporary use of centrifugal pump for pump thrombosis in patients with paracorporeal ventricular assist device].
Nipro paracorporeal ventricular assist device( VAD) is often associated with pump thrombosis which causes severe complications such as brain infarction, often requiring pump change. However, Nipro VAD pump is an expensive device and it is difficult to change pumps frequently at a short interval. We have temporarily used Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs. From January 2012 through December 2013, 19 patients underwent Nipro VADs implantation at our institution, and 9 of them underwent pump change from Nipro pumps to Rotaflow centrifugal pumps. A total of 25 Rotaflow centrifugal pumps were used in these 9 patients, with the total circulatory support duration of 526 days. The median support period was 15 days (range;2-128 days). There were 2 cerebrovascular accidents and 1 Rotaflow pump circuit thrombosis during this period. Change from Rotaflow to Nipro VAD pump resulted in decrease in hematocrit by about 3 point. There was no difference in liver or renal function between before and after the pump change. Our results suggest that temporary use of Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs may be a promising alternative.
- 1 July 2014
- Vol. 67 (8) , 657-62
[Implantable ventricular assist device].
Implantable ventricular assist device( VAD) is the only evidence-based option to treat stage D heart failure patients with significant symptoms at rest in spite of maximum medical therapy, other than heart transplant. Implantable VADs available in Japan include Evaheart, DuraHeart both from Japan, Jarvik 2000 and HeartMate II both from United States. In Japanese settings, implantable VAD is indicated and insured only for patients who are supposed to have an indication for receiving heart transplant, which means "bridge to transplantation" use. And in Japan, implantable VAD can be implanted for patients less than 65 years old if it needs to be insured. In the University of Tokyo Hospital, the mid-term outcomes of 41 implantable VAD patients were acceptable with 2 hospital deaths, 2 remote deaths and one year survival rate at 88%.Considering the present Japanese situation with extreme shortage of organ donation, the extended application of implantable VADs as "Destination Therapy" is awaited, but quality of life of care-givers as well as patients themselves and sustainable follow-up system provided by healthcare professionals need to be warranted.
- 1 July 2014
- Vol. 67 (8) , 657-62
[Implantable ventricular assist device].
Implantable ventricular assist device( VAD) is the only evidence-based option to treat stage D heart failure patients with significant symptoms at rest in spite of maximum medical therapy, other than heart transplant. Implantable VADs available in Japan include Evaheart, DuraHeart both from Japan, Jarvik 2000 and HeartMate II both from United States. In Japanese settings, implantable VAD is indicated and insured only for patients who are supposed to have an indication for receiving heart transplant, which means "bridge to transplantation" use. And in Japan, implantable VAD can be implanted for patients less than 65 years old if it needs to be insured. In the University of Tokyo Hospital, the mid-term outcomes of 41 implantable VAD patients were acceptable with 2 hospital deaths, 2 remote deaths and one year survival rate at 88%.Considering the present Japanese situation with extreme shortage of organ donation, the extended application of implantable VADs as "Destination Therapy" is awaited, but quality of life of care-givers as well as patients themselves and sustainable follow-up system provided by healthcare professionals need to be warranted.
- 1 October 2013
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 19 (10)
How are Implantable and Paracorporeal Ventricular Assist Devices Effectively Used?
- 1 October 2013
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 19 (10)
How are Implantable and Paracorporeal Ventricular Assist Devices Effectively Used?
- 1 January 2013
- Vol. 66 (1) , 51-6
[Mid-long term result of implantable ventricular assist device treatment for end-stage heart failure in the University of Tokyo Hospital].
Two implantable left ventricular assist devices(I-LVADs)were approved in Japan in 2011. I-LVADs were used for end-stage heart failure of 20 patients in our institute until March 2012. We examine the clinical course of these 20 patients who were treated with I-LVADs. End points are transplantation, death, or weaning from I-LVADs. Mean hospital days after I-LVAD implantation were 58.1 days, and all 20 patients could discharge from hospital alive. Until September 2012, mean follow up interval was 515 days. Five patients reached heart transplantation, 2 died, weaning from an I-LVAD could be done in 1 patient, and 12 continued to wait for heart transplantation. Survival rate was 100% at 1 month, 95% at 3 months, and 89% at 1 year, respectively. Mean follow up duration after discharge were 457 days, and 16 patients(80%)needed a total of 41 times of readmission in this period. Freedom from readmission was 75% at 1 month, 60% at 3 months, and 25% at 1 year, respectively. In conclusion, prognosis of I-LVAD treatment was good, but many patients needed readmission after I-LVAD implantation and follow up system for I-LVAD treatment should be improved immediately.
- 1 January 2013
- Vol. 66 (1) , 51-6
[Mid-long term result of implantable ventricular assist device treatment for end-stage heart failure in the University of Tokyo Hospital].
Two implantable left ventricular assist devices(I-LVADs)were approved in Japan in 2011. I-LVADs were used for end-stage heart failure of 20 patients in our institute until March 2012. We examine the clinical course of these 20 patients who were treated with I-LVADs. End points are transplantation, death, or weaning from I-LVADs. Mean hospital days after I-LVAD implantation were 58.1 days, and all 20 patients could discharge from hospital alive. Until September 2012, mean follow up interval was 515 days. Five patients reached heart transplantation, 2 died, weaning from an I-LVAD could be done in 1 patient, and 12 continued to wait for heart transplantation. Survival rate was 100% at 1 month, 95% at 3 months, and 89% at 1 year, respectively. Mean follow up duration after discharge were 457 days, and 16 patients(80%)needed a total of 41 times of readmission in this period. Freedom from readmission was 75% at 1 month, 60% at 3 months, and 25% at 1 year, respectively. In conclusion, prognosis of I-LVAD treatment was good, but many patients needed readmission after I-LVAD implantation and follow up system for I-LVAD treatment should be improved immediately.