S. T. Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. T. Williams has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
G. W. Cannon
Salt Lake City VA Medical Center and University of Utah Division of Rheumatology, Salt Lake City, UT, USA
1 shared publicationJ. L. Crook
University of Utah Division of Epidemiology and Salt Lake City VA Medical Center, Salt Lake City, UT, USA
1 shared publicationJ. LaFleur
University of Utah Department of Pharmacotherapy and Salt Lake City VA Medical Center, Salt Lake City, UT, USA
1 shared publication- Karla L. Miller
VA Office of Rural Health, Veterans Rural Health Resource Center-Salt Lake City (VRHRC-SLC), Salt Lake City, USA
1 shared publication - Phillip Lawrence
Veterans Affairs Salt Lake City Health Care System, Salt Lake City, UT, USA
1 shared publication R. E. Nelson
University of Utah Division of Epidemiology and Salt Lake City VA Medical Center, Salt Lake City, UT, USA
1 shared publication
Latest Publications
- 30 July 2017
- Published by Springer Nature in Osteoporosis International
- Vol. 28 (11) , 3107-3111
A comparison of electronic and manual fracture risk assessment tools in screening elderly male US veterans at risk for osteoporosis
Summary This study compares four screening tools in their ability to predict osteoporosis. We found that there was no significant difference between the tools. These results provide support for the use of automated screening tools which work in conjunction with the electronic medical record and help improve screening rates for osteoporosis. Introduction The purpose of this study is to compare the performance of four fracture risk assessment tools (FRATs) in identifying osteoporosis by bone mineral density (BMD) T-score: Veterans Affairs Fracture Absolute Risk Assessment Tool (VA-FARA), World Health Organization’s Fracture Risk Assessment Tool (FRAX), electronic FRAX (e-FRAX), and Osteoporosis Self-Assessment Screening Tool (OST). Methods We performed a cross-sectional analysis of all patients enrolled in the VA Salt Lake City bone health team (BHT) who had completed a DXA scan between February 1, 2012, and February 1, 2013. DXA scan results were obtained by chart abstraction. For calculation of FRAX, osteoporosis risk factors were obtained from a screening questionnaire completed prior to DXA. For VA-FARA and e-FRAX, risk factors were derived from the electronic medical record (EMR). Clinical risk scores were calculated and compared against the gold standard of DXA-based osteoporosis. Sensitivity, specificity, and predictive values were calculated. Receiver operator characteristic (ROC) curves were plotted, and areas under the curve (AUC) were compared. Results A cohort of 463 patients met eligibility criteria (mean age 80.4 years). One hundred twelve patients (24%) had osteoporosis as defined by DXA T-score ≤−2.5. Sensitivity, specificity, and predictive values were calculated. ROC statistics were compared and did not reach statistical significance difference between FRATs in identifying DXA-based osteoporosis. Conclusions Our study suggests that all FRATs tested perform similarly in identifying osteoporosis among elderly, primarily Caucasian, male veterans. If these electronic screening methods perform similarly for fracture outcomes, they could replace manual FRAX and thus improve efficiency in identifying individuals who should be sent for DXA scan.
- 30 July 2017
- Published by Springer Nature in Osteoporosis International
- Vol. 28 (11) , 3107-3111
A comparison of electronic and manual fracture risk assessment tools in screening elderly male US veterans at risk for osteoporosis
Summary This study compares four screening tools in their ability to predict osteoporosis. We found that there was no significant difference between the tools. These results provide support for the use of automated screening tools which work in conjunction with the electronic medical record and help improve screening rates for osteoporosis. Introduction The purpose of this study is to compare the performance of four fracture risk assessment tools (FRATs) in identifying osteoporosis by bone mineral density (BMD) T-score: Veterans Affairs Fracture Absolute Risk Assessment Tool (VA-FARA), World Health Organization’s Fracture Risk Assessment Tool (FRAX), electronic FRAX (e-FRAX), and Osteoporosis Self-Assessment Screening Tool (OST). Methods We performed a cross-sectional analysis of all patients enrolled in the VA Salt Lake City bone health team (BHT) who had completed a DXA scan between February 1, 2012, and February 1, 2013. DXA scan results were obtained by chart abstraction. For calculation of FRAX, osteoporosis risk factors were obtained from a screening questionnaire completed prior to DXA. For VA-FARA and e-FRAX, risk factors were derived from the electronic medical record (EMR). Clinical risk scores were calculated and compared against the gold standard of DXA-based osteoporosis. Sensitivity, specificity, and predictive values were calculated. Receiver operator characteristic (ROC) curves were plotted, and areas under the curve (AUC) were compared. Results A cohort of 463 patients met eligibility criteria (mean age 80.4 years). One hundred twelve patients (24%) had osteoporosis as defined by DXA T-score ≤−2.5. Sensitivity, specificity, and predictive values were calculated. ROC statistics were compared and did not reach statistical significance difference between FRATs in identifying DXA-based osteoporosis. Conclusions Our study suggests that all FRATs tested perform similarly in identifying osteoporosis among elderly, primarily Caucasian, male veterans. If these electronic screening methods perform similarly for fracture outcomes, they could replace manual FRAX and thus improve efficiency in identifying individuals who should be sent for DXA scan.