Masao Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masao Watanabe has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Nojiri
Tohoku University
2 shared publications - Dai Yamazaki
J-PARC Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195, Japan
1 shared publication - Hideshi Yamagishi
Nippon Advanced Technology, Ltd., Tokai, Ibaraki 319-1106, Japan
1 shared publication - Hiroshi Kira
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), 162-1 Shirakata, Ibaraki 319-1106, Japan
1 shared publication - Hirotoshi Hayashida
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), Tokai, Ibaraki 319-1106, Japan
1 shared publication - Jiro Suzuki
Computing Research Center, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 300-3256, Japan
1 shared publication
Latest Publications
- Open Access
- 27 December 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 7 (1) , 1
Automated Pulsed Magnet System for Neutron Diffraction Experiments at the Materials and Life Science Experimental Facility in J-PARC
A pulsed magnet system has been developed as a new user-friendly sample environment equipment at the Materials and Life Science Experimental Facility in Japan Proton Accelerator Research Complex. It comprises a vacuum chamber, a 4 K closed-cycle refrigerator for samples, and a nitrogen bath made of a stainless-steel tube with a miniature solenoidal coil. The coil is cooled by liquid nitrogen supplied by an automatic liquid nitrogen supply system, and the sample is cooled by a refrigerator. This combination facilitates the automatic high magnetic field diffraction measurement for the user’s operation. A relatively large scattering angle 2θ is up to 42°, which is significantly wider than the previous setup. Neutron diffraction experiments were performed on a multiferroic TbMnO3 and the field dependence of the diffraction peaks was clearly observed. The new pulsed magnet system was established for a practical high magnetic field diffraction for the user program.
- 27 December 2022
- Published by MDPI AG in Quantum Beam Science
- Vol. 7 (1) , 1
Open AccessAutomated Pulsed Magnet System for Neutron Diffraction Experiments at the Materials and Life Science Experimental Facility in J-PARC
A pulsed magnet system has been developed as a new user-friendly sample environment equipment at the Materials and Life Science Experimental Facility in Japan Proton Accelerator Research Complex. It comprises a vacuum chamber, a 4 K closed-cycle refrigerator for samples, and a nitrogen bath made of a stainless-steel tube with a miniature solenoidal coil. The coil is cooled by liquid nitrogen supplied by an automatic liquid nitrogen supply system, and the sample is cooled by a refrigerator. This combination facilitates the automatic high magnetic field diffraction measurement for the user’s operation. A relatively large scattering angle 2θ is up to 42°, which is significantly wider than the previous setup. Neutron diffraction experiments were performed on a multiferroic TbMnO3 and the field dependence of the diffraction peaks was clearly observed. The new pulsed magnet system was established for a practical high magnetic field diffraction for the user program.
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 39-45
Pulsed magnet system at MLF in J-PARC
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 39-45
Pulsed magnet system at MLF in J-PARC
- Open Access
- 3 August 2017
- Published by MDPI AG in Quantum Beam Science
- Vol. 1 (2) , 10
Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex III: Neutron Devices and Computational and Sample Environments
Neutron devices such as neutron detectors, optical devices including supermirror devices and 3He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.
- 3 August 2017
- Published by MDPI AG in Quantum Beam Science
- Vol. 1 (2) , 10
Open AccessMaterials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex III: Neutron Devices and Computational and Sample Environments
Neutron devices such as neutron detectors, optical devices including supermirror devices and 3He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.