Hao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Zhang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Wei Pang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
9 shared publications - Xuexin Duan
State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
8 shared publications - Daihua Zhang
State Key Laboratory of Precision Measurement Technology and Instruments, School of Precision Instruments and Opto-electronics Engineering , Tianjin University , No. 92 Weijin Road , Tianjin 300072 , China
7 shared publications Wei Pang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
5 shared publications- Wenpeng Liu
Harvard Medical School Harvard University Boston MA 02115 USA
4 shared publications - Hemi Qu
State Key Laboratory of Precision Measuring Technology & Instruments , Tianjin University , Tianjin 300072 , China
3 shared publications
Latest Publications
- 11 November 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (46) , 465102
An integrated multi-pass radial-resonant photoacoustic spectroscopy for ppb-level trace gas detection
An integrated microsystem for trace gas detection based on multi-pass radial resonant photoacoustic spectroscopy (MR-PAS) has been proposed. A polished photoacoustic cavity is specifically designed to facilitate incident laser light coupling, enable multi-pass reflection, and resonantly amplify the photoacoustic (PA) pressure. Finite element analysis (FEA) is employed to simulate the acoustic field distribution, frequency response, and ray tracing behavior. Simulation results reveal that the designed cavity achieves 771-fold excitation of the incident laser and amplifies PA pressure by operating in the first-order radial resonant mode. To validate the performance of the MR-PAS, a CO 2 detection system is constructed. Experimental results demonstrate that the MR-PAS achieves an impressive minimum detection limit (MDL) of 12.4 ppb with a 274 s integration time, according to the normalized noise-equivalent absorption coefficient of 1.71 × 10 −8 cm −1 ·W·Hz −1 / 2 . The compact photoacoustic cavity (1.1 ml) enables rapid response, with gas replacement and stabilization within ∼4.4 s at a flow rate of 50 sccm.
- 11 November 2025
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 58 (46) , 465102
An integrated multi-pass radial-resonant photoacoustic spectroscopy for ppb-level trace gas detection
An integrated microsystem for trace gas detection based on multi-pass radial resonant photoacoustic spectroscopy (MR-PAS) has been proposed. A polished photoacoustic cavity is specifically designed to facilitate incident laser light coupling, enable multi-pass reflection, and resonantly amplify the photoacoustic (PA) pressure. Finite element analysis (FEA) is employed to simulate the acoustic field distribution, frequency response, and ray tracing behavior. Simulation results reveal that the designed cavity achieves 771-fold excitation of the incident laser and amplifies PA pressure by operating in the first-order radial resonant mode. To validate the performance of the MR-PAS, a CO 2 detection system is constructed. Experimental results demonstrate that the MR-PAS achieves an impressive minimum detection limit (MDL) of 12.4 ppb with a 274 s integration time, according to the normalized noise-equivalent absorption coefficient of 1.71 × 10 −8 cm −1 ·W·Hz −1 / 2 . The compact photoacoustic cavity (1.1 ml) enables rapid response, with gas replacement and stabilization within ∼4.4 s at a flow rate of 50 sccm.
- Open Access
- 13 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1238
A Sensitivity-Enhanced Electrolyte-Gated Graphene Field-Effect Transistor Biosensor by Acoustic Tweezers
Low-abundance biomolecule detection is very crucial in many biological and medical applications. In this paper, we present a novel electrolyte-gated graphene field-effect transistor (EGFET) biosensor consisting of acoustic tweezers to increase the sensitivity. The acoustic tweezers are based on a high-frequency bulk acoustic resonator with thousands of MHz, which has excellent ability to concentrate nanoparticles. The operating principle of the acoustic tweezers to concentrate biomolecules is analyzed and verified by experiments. After the actuation of acoustic tweezers for 10 min, the IgG molecules are accumulated onto the graphene. The sensitivities of the EGFET biosensor with accumulation and without accumulation are compared. As a result, the sensitivity of the graphene-based biosensor is remarkably increased using SMR as the biomolecule concentrator. Since the device has advantages such as miniaturized size, low reagent consumption, high sensitivity, and rapid detection, we expect it to be readily applied to many biological and medical applications.
- 13 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1238
Open AccessA Sensitivity-Enhanced Electrolyte-Gated Graphene Field-Effect Transistor Biosensor by Acoustic Tweezers
Low-abundance biomolecule detection is very crucial in many biological and medical applications. In this paper, we present a novel electrolyte-gated graphene field-effect transistor (EGFET) biosensor consisting of acoustic tweezers to increase the sensitivity. The acoustic tweezers are based on a high-frequency bulk acoustic resonator with thousands of MHz, which has excellent ability to concentrate nanoparticles. The operating principle of the acoustic tweezers to concentrate biomolecules is analyzed and verified by experiments. After the actuation of acoustic tweezers for 10 min, the IgG molecules are accumulated onto the graphene. The sensitivities of the EGFET biosensor with accumulation and without accumulation are compared. As a result, the sensitivity of the graphene-based biosensor is remarkably increased using SMR as the biomolecule concentrator. Since the device has advantages such as miniaturized size, low reagent consumption, high sensitivity, and rapid detection, we expect it to be readily applied to many biological and medical applications.
- 9 May 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (21) , 10148-10153
Acoustically enhanced photodetection by a black phosphorus–MoS2 van der Waals heterojunction p–n diode
We developed a new way to enhance the photoresponsivity of a van der Waals heterojunction p–n diode using surface acoustic waves (SAWs). The diode was constructed on top of a piezoelectric LiNbO3 substrate and composed of p-type black phosphorus (BP) and n-type molybdenum disulfide (MoS2) flakes that partly overlapped with each other. This layout facilitated the applied SAWs to rapidly drive carriers out of the depletion region. In this structural design, SAWs promoted the separation of photogenerated carriers, and thus greatly increased the photocurrent. The measured photocurrent for the device with SAWs was about 103 times higher than that of the device without SAWs. The device using SAWs showed a photoresponsivity as high as 2.17 A W−1 at the wavelength of 582 nm. This excellent performance was attributed to the SAWs suppressing electron–hole recombination in the device under light illumination. Our device exhibits promise as a high-performance photodetector and reveals new possibilities for acoustic devices in optoelectronics.
- 9 May 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (21) , 10148-10153
Acoustically enhanced photodetection by a black phosphorus–MoS2 van der Waals heterojunction p–n diode
We developed a new way to enhance the photoresponsivity of a van der Waals heterojunction p–n diode using surface acoustic waves (SAWs). The diode was constructed on top of a piezoelectric LiNbO3 substrate and composed of p-type black phosphorus (BP) and n-type molybdenum disulfide (MoS2) flakes that partly overlapped with each other. This layout facilitated the applied SAWs to rapidly drive carriers out of the depletion region. In this structural design, SAWs promoted the separation of photogenerated carriers, and thus greatly increased the photocurrent. The measured photocurrent for the device with SAWs was about 103 times higher than that of the device without SAWs. The device using SAWs showed a photoresponsivity as high as 2.17 A W−1 at the wavelength of 582 nm. This excellent performance was attributed to the SAWs suppressing electron–hole recombination in the device under light illumination. Our device exhibits promise as a high-performance photodetector and reveals new possibilities for acoustic devices in optoelectronics.
- 16 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 17 (3) , 590-595
Anomalous Acoustoelectric Currents in Few-Layer Black Phosphorus Nanocrystals
We report on anomalous acoustoelectric (AE) currents in few-layer black phosphorus (BP) nanocrystals as the result of strong Brag reflections. The device consists of a surface acoustic wave (SAW) delay line and a BP field-effect transistor (FET), which uses a graphene film as its gate electrode with an atomically thin boron nitride gate dielectric layer. It was found that the Brag reflection could give rise to large anomalous AE currents when the hole concentration was sufficiently large. Our experimental results showed that the magnitude and direction of the anomalous AE currents were related to the applied bias and position of the device with respect to the nodes/antinodes of the standing waves. The observations have been explained by our proposed model. Our work provides more insights into the interaction between SAW and 2D materials and highlights the particularity of anomalous AE effect in such systems.
- 16 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanotechnology
- Vol. 17 (3) , 590-595
Anomalous Acoustoelectric Currents in Few-Layer Black Phosphorus Nanocrystals
We report on anomalous acoustoelectric (AE) currents in few-layer black phosphorus (BP) nanocrystals as the result of strong Brag reflections. The device consists of a surface acoustic wave (SAW) delay line and a BP field-effect transistor (FET), which uses a graphene film as its gate electrode with an atomically thin boron nitride gate dielectric layer. It was found that the Brag reflection could give rise to large anomalous AE currents when the hole concentration was sufficiently large. Our experimental results showed that the magnitude and direction of the anomalous AE currents were related to the applied bias and position of the device with respect to the nodes/antinodes of the standing waves. The observations have been explained by our proposed model. Our work provides more insights into the interaction between SAW and 2D materials and highlights the particularity of anomalous AE effect in such systems.
- Open Access
- 7 August 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (8) , 244
Mechanical Vibration Measurement of Solidly Mounted Resonator in Fluid by Atomic Force Microscopy
The very small vibration of a solidly-mounted resonator (SMR) in fluid may trigger a relatively large motion of the covering fluid, which was implied by our protein-related experimental results. Therefore, a series of experimental methods for characterizing the mechanical longitudinal vibration of the SMR and the corresponding out-of-plane dynamic response of the fluid above the SMR surface is described in this paper. A SMR device with theoretical resonance frequency of 2.5 GHz was driven by an amplitude-modulated (AM) signal, in which the amplitude is modulated by a signal of the second resonance frequency of the atomic force microscope (AFM) cantilever. A lock-in amplifier is used to demodulate the vibration response of the AFM cantilever, which is proportional to the amplitude of the sample vibration in contact mode and tapping mode. The amplitude-frequency curve of the SMR surface is obtained in contact mode with a relatively stronger interaction force between the AFM tip and the SMR surface. The amplitude-frequency curve of the motion of the liquid above the SMR device and the peak amplitude of the fluid at different distances above the SMR surface are measured in tapping mode with a relatively weak interaction force between the AFM tip and the fluid sample.
- 7 August 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (8) , 244
Open AccessMechanical Vibration Measurement of Solidly Mounted Resonator in Fluid by Atomic Force Microscopy
The very small vibration of a solidly-mounted resonator (SMR) in fluid may trigger a relatively large motion of the covering fluid, which was implied by our protein-related experimental results. Therefore, a series of experimental methods for characterizing the mechanical longitudinal vibration of the SMR and the corresponding out-of-plane dynamic response of the fluid above the SMR surface is described in this paper. A SMR device with theoretical resonance frequency of 2.5 GHz was driven by an amplitude-modulated (AM) signal, in which the amplitude is modulated by a signal of the second resonance frequency of the atomic force microscope (AFM) cantilever. A lock-in amplifier is used to demodulate the vibration response of the AFM cantilever, which is proportional to the amplitude of the sample vibration in contact mode and tapping mode. The amplitude-frequency curve of the SMR surface is obtained in contact mode with a relatively stronger interaction force between the AFM tip and the SMR surface. The amplitude-frequency curve of the motion of the liquid above the SMR device and the peak amplitude of the fluid at different distances above the SMR surface are measured in tapping mode with a relatively weak interaction force between the AFM tip and the fluid sample.
- Open Access
Novel Gas Sensor Arrays Based on High-Q SAM-Modified Piezotransduced Single-Crystal Silicon Bulk Acoustic Resonators
This paper demonstrates a novel micro-size (120 μm × 200 μm) piezoelectric gas sensor based on a piezotransduced single-crystal silicon bulk acoustic resonator (PSBAR). The PSBARs operate at 102 MHz and possess high Q values (about 2000), ensuring the stability of the measurement. A corresponding gas sensor array is fabricated by integrating three different self-assembled monolayers (SAMs) modified PSBARs. The limit of detection (LOD) for ethanol vapor is demonstrated to be as low as 25 ppm with a sensitivity of about 1.5 Hz/ppm. Two sets of identification code bars based on the sensitivities and the adsorption energy constants are utilized to successfully discriminate isopropanol (IPA), ethanol, hexane and heptane vapors at low and high gas partial pressures, respectively. The proposed sensor array shows the potential to form a portable electronic nose system for volatile organic compound (VOC) differentiation.
Open AccessNovel Gas Sensor Arrays Based on High-Q SAM-Modified Piezotransduced Single-Crystal Silicon Bulk Acoustic Resonators
This paper demonstrates a novel micro-size (120 μm × 200 μm) piezoelectric gas sensor based on a piezotransduced single-crystal silicon bulk acoustic resonator (PSBAR). The PSBARs operate at 102 MHz and possess high Q values (about 2000), ensuring the stability of the measurement. A corresponding gas sensor array is fabricated by integrating three different self-assembled monolayers (SAMs) modified PSBARs. The limit of detection (LOD) for ethanol vapor is demonstrated to be as low as 25 ppm with a sensitivity of about 1.5 Hz/ppm. Two sets of identification code bars based on the sensitivities and the adsorption energy constants are utilized to successfully discriminate isopropanol (IPA), ethanol, hexane and heptane vapors at low and high gas partial pressures, respectively. The proposed sensor array shows the potential to form a portable electronic nose system for volatile organic compound (VOC) differentiation.
- Open Access
- 5 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 178
Correction: Liu, W. et al. A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films. Micromachines, 2017, 8, 116
In the published paper [1], there is an error in Figure 3
- 5 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 178
Open AccessCorrection: Liu, W. et al. A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films. Micromachines, 2017, 8, 116
In the published paper [1], there is an error in Figure 3
- Open Access
- 12 May 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (5) , 155
Enhanced Sensitivity of MoTe2 Chemical Sensor through Light Illumination
Two-dimensional (2D) transition metal dichalcogenides (TMDCs) semiconducting materials have recently attracted wide attention and been regarded as promising building blocks for chemical sensors due to their high surface-to-volume ratio. However, their low response hinders the realization of high-performance 2D TMDCs chemical sensors. Here, we demonstrate the improvement of sensing performance of molybdenum ditelluride (MoTe2) gas sensor through continuous light illumination. The dependence of sensing performance on the energy of photons and light intensity is systematically studied. The response to NH3 is dramatically enhanced by more than 25 times under 254 nm ultraviolet (UV) light illumination with intensity of 2.5 mW/cm2. Moreover, a remarkable low detection limit of 3 ppb is achieved, which is improved by 80 times compared with that in dark condition. The results demonstrate that light illumination is a promising method to improve the sensitivity of 2D TMDCs chemical sensors.
- 12 May 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (5) , 155
Open AccessEnhanced Sensitivity of MoTe2 Chemical Sensor through Light Illumination
Two-dimensional (2D) transition metal dichalcogenides (TMDCs) semiconducting materials have recently attracted wide attention and been regarded as promising building blocks for chemical sensors due to their high surface-to-volume ratio. However, their low response hinders the realization of high-performance 2D TMDCs chemical sensors. Here, we demonstrate the improvement of sensing performance of molybdenum ditelluride (MoTe2) gas sensor through continuous light illumination. The dependence of sensing performance on the energy of photons and light intensity is systematically studied. The response to NH3 is dramatically enhanced by more than 25 times under 254 nm ultraviolet (UV) light illumination with intensity of 2.5 mW/cm2. Moreover, a remarkable low detection limit of 3 ppb is achieved, which is improved by 80 times compared with that in dark condition. The results demonstrate that light illumination is a promising method to improve the sensitivity of 2D TMDCs chemical sensors.
- Open Access
- 5 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 116
A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films
We developed a highly sensitive humidity sensor based on the combination of ultrahigh-frequency film bulk acoustic resonator (FBAR) and nano-assembled polyelectrolyte (PET) thin films. The water molecule absorption efficiency was optimized by forming loosely-packed PET nanostructures. Then, the humidity sensing characteristics were analyzed in terms of sensitivity, linearity, reversibility, stability and detection limit. As a result, PET-coated FBAR exhibits excellent humidity sensitivity of 2202.20 Hz/ppm, which is five orders of magnitude higher than quartz crystal microbalance (QCM). Additionally, temperature dependence was investigated with the result that PET-coated FBAR possessed a higher sensitivity at low temperature. Furthermore, we realized the selective detection of water vapor from volatile organic compounds (VOCs) with respect to the polarity property. Owing to the high sensitivity, miniaturized size and ultrahigh operating frequency, PET-coated FBAR is uniquely favorable as a wireless humidity sensor node to integrate into wireless sensor networks (WSNs).
- 5 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 116
Open AccessA Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films
We developed a highly sensitive humidity sensor based on the combination of ultrahigh-frequency film bulk acoustic resonator (FBAR) and nano-assembled polyelectrolyte (PET) thin films. The water molecule absorption efficiency was optimized by forming loosely-packed PET nanostructures. Then, the humidity sensing characteristics were analyzed in terms of sensitivity, linearity, reversibility, stability and detection limit. As a result, PET-coated FBAR exhibits excellent humidity sensitivity of 2202.20 Hz/ppm, which is five orders of magnitude higher than quartz crystal microbalance (QCM). Additionally, temperature dependence was investigated with the result that PET-coated FBAR possessed a higher sensitivity at low temperature. Furthermore, we realized the selective detection of water vapor from volatile organic compounds (VOCs) with respect to the polarity property. Owing to the high sensitivity, miniaturized size and ultrahigh operating frequency, PET-coated FBAR is uniquely favorable as a wireless humidity sensor node to integrate into wireless sensor networks (WSNs).
- Open Access
- 24 December 2016
- Published by MDPI AG in Micromachines
- Vol. 8 (1) , 2
MEMS Gyroscopes Based on Acoustic Sagnac Effect
This paper reports on the design, fabrication and preliminary test results of a novel microelectromechanical systems (MEMS) device—the acoustic gyroscope. The unique operating mechanism is based on the “acoustic version” of the Sagnac effect in fiber-optic gyros. The device measures the phase difference between two sound waves traveling in opposite directions, and correlates the signal to the angular velocity of the hosting frame. As sound travels significantly slower than light and develops a larger phase change within the same path length, the acoustic gyro can potentially outperform fiber-optic gyros in sensitivity and form factor. It also promises superior stability compared to vibratory MEMS gyros as the design contains no moving parts and is largely insensitive to mechanical stress or temperature. We have carried out systematic simulations and experiments, and developed a series of processes and design rules to implement the device.
- 24 December 2016
- Published by MDPI AG in Micromachines
- Vol. 8 (1) , 2
Open AccessMEMS Gyroscopes Based on Acoustic Sagnac Effect
This paper reports on the design, fabrication and preliminary test results of a novel microelectromechanical systems (MEMS) device—the acoustic gyroscope. The unique operating mechanism is based on the “acoustic version” of the Sagnac effect in fiber-optic gyros. The device measures the phase difference between two sound waves traveling in opposite directions, and correlates the signal to the angular velocity of the hosting frame. As sound travels significantly slower than light and develops a larger phase change within the same path length, the acoustic gyro can potentially outperform fiber-optic gyros in sensitivity and form factor. It also promises superior stability compared to vibratory MEMS gyros as the design contains no moving parts and is largely insensitive to mechanical stress or temperature. We have carried out systematic simulations and experiments, and developed a series of processes and design rules to implement the device.